Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.7 LAccepted-Finance Z 67 OKHLA INDUSTRIAL AREA PHASE II NEW DELHI DELHI 110020 | SOUTH EAST DELHI | DELHI | 110020 | L1 | Accepted-Finance OK | |
| 2 | L2₹37.3 L+₹4.6 L (14.2%)Accepted-Finance | L2 | Accepted-Finance OK |
Tender Value
Refer Docs
EMD Value
₹66,250
Closing Date
21 Sept 2023, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWA
WAZIRABAD WATER WORKS TIMARPUR DELHI
PURCHASE OF BIO SAFETY CABINET CLASS II TYPE A2 WITH CUPBOARD , FUME CANOPY , SONICATOR AND SPOT EXTRACTOR FOR NEWLY BUILT BACTERIOLOGICAL SECTION WAZIRABAD
2023_DJB_247247_3
PRESS NIT NO.03(2023-24)CWA (W and S)-I
Open Tender
Miscellaneous Goods
Works
WAZIRABAD WATER WORKS TIMARPUR DELHI
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Account No SB 06121000095461
₹66,250
4 Oct 2023
6 Sept 2023
21 Sept 2023
6 Sept 2023
21 Sept 2023
6 Sept 2023
6 Sept 2023 - 21 Sept 2023
SpecificationsforBioSafetyCabinetClassIITypeA2 withCupboard Make/Brands: Esco, Nuaire,Thermic, Impact, Thermo• Air Flow : 30% air exhaust 70% air recirculation • HEPA-filtered exhaust air in Type A2 cabinet may be recirculated into the room or exhausted to the outdoors through a canopy exhaust connection.• HEPA-filtered downflow air is a portion of mixed downflow and inflow air from a common plenum• Negative Pressure air surrounding all biological contaminated ducts and plenums.• Negative pressure surrounds the work area with double wall plenums for protection.• Air drawn through pre-filter is made to pass through highly effective HEPA (High Efficiency Particular Air) filters having efficiency rating as high as 99.99% with cold DOP and 99.97% with hot DOP, thus retaining all air-borne particles of size 0.3 micron and large. The highly efficient HEPA filter maintains the optimum cleanliness and purity. Being equipped with the prefilter, it can extend the life of HEPA filter.• Sash is counterbalanced for smooth and light weight operation with standard openingof 200mm ±10 mm for easier access to work zone and enhanced user safety. Complete with Cupboard enable the user to sit & work alongwith one Drawer & Closet Dimensions (in feet): Size:- 3.6x2x2 Material of Construction (MOC): a. Inner Chamber SS 304 grade.,b. Outer Chamber: GALVANIZED PLAIN SHEETS 01 mm, c. Working Table:- SS 304 Grade. d. Cupboard with one Drawer & Closet Pre Filter:- Mounted on aluminium frame, of rating 20 microns HEPA Filter:- HEPA(Efficiency 99.97%@0.3 microns to meet air quality ISO Class 4 equivalent to USFED STD 209E, class 10) Service Fixture:- Supply Port for Gas/ Vacuum/ Air Sash:- Can be lifted & adjusted Manually Virus Burnout:- Virus Burnout System Hepa Filter in Exhaust also Controller: • Touch Screen Controller• Password for Authorized Operation• Built in differential Pressure display• Air Velocity Display• Real Time Clock• UV Timer• Total UV used Time• Total Hepa Filter run time• Hepa Filter Alarm after programmed hours with ON/Off• Hepa Filter life display & alarm• Cabinet Temperature Display• UV Light in work chamber inter locked with door Power Consumption: 220/230V AC± 10%, AC Supply Single Phase 50Hz Duty Cycle: Continuous
Specifications of Fume Canopy Canopy or fixed extraction system is required for local ventilation of fumes in labs. Stainless Steel Canopy hoods Should be constructed of 304 stainless steel and designed to exhaust heat, steam when mounted over equipment. Technical Specifications 1. Size 72” x 24” 2. MOC – 1 MM Stainless Steel 304 Grade 3. Exhaust duct Diameter – 200mm/ 250 mm 4. 12 cm centrifugal blower, 50 mm WC static pressure 1440 RPM, 3 phase 1.5 hp DOL starter motor for cluster of canopy. 5. Ducting: Max. 30 Running feet Installation: Installation will include provisioning, fixing commissioning and testing of complete suction system connection with duct and blower
Specifications for SONICATOR Make/Brands: Fisherbrand, Ultrawave, Antalia, Thermic, Impact, Capacity: 14 Litres (+ 1L), Dimensions (in mm): Inner: 300x240x200 mm Outer: 430x340x400 mm Specification:-• Electric Supply : 230 V AC 1 Phase OR 440 V , A.C, 50 Hz 3 phase.• Ultrasonic Power : 500 Watt • Temp:_ Upto 60 Deg C• Ultrasonic Frequency : 40 K Hz , +/- 3 KHz• Ultrasonic Generator : Micro Controller base Digital Timer .• With latest MOSFET base technology.• With Auto Degassing facility.• Automatic frequency tuning for maximum output• Modular generator for easier modification/servicing.• Timer : Two Digit LED display 0 – 90 minutes Timer with settable & On / Off keys.• Heater : S.S sheathed cartridge type immersion heater Heater can easily be replaced.• Temperature Control : Maximum allowable Temp is 60°C• Digital Temp/ Controller with two Digit LED Display with settable & On / Off• Transducers : PZT Sandwich type, bonded on the base of S.S Tank, Crystal used of PZT4, ofvmatrock Morgon Make. High temp. & good quality wires for connection & epoxy for bonding of transducers are used.• Tank MOQ : S.S 304 grade, 1.6mm thick & buffed form inside• Tank Capacity : 14 Liters• Inlet & Drain Valve : 1/2" Ball Valve is provided for cleaning for the Both tank• Over Flow Tap : ½ “ Tap • Enclosure MOQ : S.S 304 grade.• Float Switch protection : Ultrasonic Cleaner will start when tank solution will fill up to the marking level. This is for protection of crystals• Micro Controller base Digital Timer .• With latest MOSFET base technology.• Automatic frequency tuning for maximum output• Low transducer losses permit maximum cleaning action.• Modular generator for easier modification/servicing.• Rugged and easy to clean stainless steel housing.• Extensively protected electronics circuits for longer and safe operation.• Frequency 40 KHz + 3 KHz fixed frequency• Supply voltage of 230 V AC 1 Phase OR 440 V AC 3 Phase• Inbuilt Digital Timer & Digital Temp. Controller Up to 60 Deg . C• Single Stage : Only One Ultrasonic Chamber• Float Switch protection : Ultrasonic Cleaner will start when tank solution will fill up to the marking level. This is for protection of crystals
Specifications for Spot Extractor Spot extractors required to exhaust out locally generated fumes during laboratory analysis. It shall have 3 Degree of freedom ie; it can be move in any direction as per requirement. Technical Specification • Joint: high grade PP, to be 360° dismantled & assembled easily for cleaning • Joint seal ring: High-density anti-aging rubber • Support spring/ centre bolt: Stainless Steel 304 • Adjustable joint knob: high grade PP with a moulded in brass nut locking with centre bolt • Air flow control valve: adjust the external valve knob manually to control the entering of the gas flow • Dome/cup hood: D375mm/200mm, high grade PP red, grey & transparent available • Rigid Flexible Duct: D75mm PVC/PP • Bracket: High grade PP (ceiling/wall mounted)
MAZELINOV SOLUTIONS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .