Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.5 LAccepted-AOC 204B SENTHAMANGALAM GOTHANDARAMPURAM VILLAGE PERUMANADU POST VAYALOGAM VIA PUDUKKOTTAI DIST TN | PUDUKKOTTAI | TAMIL NADU | 622104 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹22.7 L+₹2.2 L (10.6%)Rejected-Finance 1 181 KAMATCHI AMMAN KOVIL STREET KANNAN COLONY CHINTHAMANI MADURAI 625009 | MADURAI | MADURAI | TAMIL NADU | 625009 | L2 | Rejected-Finance Being Not Lowest Tenderer | |
| 3 | L3₹22.9 L+₹2.4 L (11.6%)Rejected-Finance | L3 | Rejected-Finance Being Not Lowest Tenderer |
Tender Value
₹22 L
EMD Value
₹44,000
Closing Date
29 Nov 2022, 6:00 pmClosed
GE Wellington
Garrison Engineer Wellington Barrack Post Nilgiris Pin code-643231
REPAIRS TO JOINERIES FLOORS INCLUDING SUNKEN FLOOR AND REPLACEMENT OF SANITARY FITTINGS PIPE FITTINGS AND BUMBLING LINES AND REPAIRS TO COMPOUND WALL FENCING GATE AND HARD STANDING PAVER BLOCK AND REPAIRS CLEANING OF SEWER LINES STORM WATER DRAINS AT
2022_MES_560785_1
8742/E8
Open Tender
Civil Works
Item Rate
180 days
Trichy
As per Tender Documents
4 documents required · 4 mandatory
₹500
GE Wellington
₹44,000
Yes
8 Apr 2023
1 Nov 2022
6 Dec 2022
2 Nov 2022
29 Nov 2022
15 Nov 2022
Amount
Taking down chowkat or frame with shutter (without taking of shutters from the frames) area not exceeding 1.5 Sq mtr each all as specified and directed.
Taking down chowkat or frame with shutter (without taking off shutters from the frames) area exceeding 1.5 Sq mtr but not exceeding 4 Sq mtr each all as specified and directed.
Taking down Shutters of any description exceeding. 1 sqm and not exceeding 2 sqm all as specified and directed.
Taking down Shutter of any discription not exceeding 1 sqm each all as specified and directed.
2nd class hard wood wood Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid rounded or chamfered put together with glue, pinned at joint all as specified and as directed.
35mm thick second class hardwood glazed and skeleton door shutters open rebated and prepared to receive glass, gauze etc, (without sash bars), edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass, sizes of members of shutter as specified in SSR Part-I section 8, clause 8.24 (a) supplied and fitted to chowkats complete all as specified and directed. Note: Glazing and gauze will be measured and paid separately.
35mm thick factory made, panelled shutter (two panel) with lock rail and panel of 9mm BWP commercial ply or 12mm veneer particle board with commercial veneering on both faces. The size of the rail and as per IS 1003 (Part -I) Kiln seasoned and chemically pressure treated all as specified and directed.
Solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS Square tube,supplying and fixing in opening as per specification and drawing all as specified and directed.
Factory made solid panel PVC door shutter 30mm (Style) consisting of frame made out of M.S tubes for top and bottom rails M.S frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail, panelling of plain colour PVC sheets to be fitted in the M.S frame welded/sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement, supplying and fixing in the frame all as specified and directed.
30mm thick second class hardwood glazed and skeleton door shutters open rebated and prepared to receive glass, gauze etc, (without sash bars), edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass, sizes of members of shutter as specified in SSR Part-I section 8, clause 8.24 (a) supplied and fitted to chowkats complete all as specified and directed.
35 mm thick flush shutter,solid core construction, with block Board Core and plywood face panels, commercial type on both sides complete all as specified and as directed.
Mild steel Framed work such as grill, grating etc with ends of bars shouldered and /or riveted or forged into spikes, framed guard bars, barred iron door, ladders, framed balusters and simialr work conforming to Fe290 Gde E-165 all as specified and directed.
Butt hinges, 100 mm size medium weight, cold rolled mild steel, and fixed complete all as specified and directed.
Butt hinges extruded Aluminium alloy with galvanized mild steel hinge pin, anodized and fixed, type C-21, with MS hinge pin 100mm size all as specified and directed.
MS Butt hinges medium weight cold rolled mild steel 75mm long complete all as specified and directed.
Aluminium anodized barrel tower bolt of extruded section 150mm length all as specified and directed.
Aluminum anodized barrel tower bolts of extruded section 100 mm long all as specified and directed.
Aluminum anodized barrel tower bolts of extruded section 75 mm long all as specified and directed.
Aluminum handles, fabricated type ,anodised extruded section 150 mm long all as specified and directed.
Aluminum handles, fabricated type ,anodised extruded section 100 mm long all as specified and directed.
300 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed.
Floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel pin fixed to door of 140mm overall length all as specified and directed.
Single action spring hinges mild steel wire spring, stove enamelled, black all as specified and directed.
Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless wire staples complete all as specified and directed.
Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless wire staples as in repairs to steel / wooden joinery complete all as specified and directed.
Ground or frosted 4 mm thick sheet glass ordinary quality and glazing with oil putty in squares not exceeding 0.5 sqm in each pane complete all as specified and directed.
4 mm thick sheet glass ordinary quality and glazing with oil putty in squares not exceeding 0.5 sqm in each pane complete all as specified and directed.
Plain sheet glass 4.0mm thick ordinary quality and glazing with oil putty in square exceeding 0.5 Sq.m in each pane complete all as specified and directed.
Fancy type Steel PVC Coated, drapery rod of size 20-25mm dia, including fixing of Steel powder coated fancy brackets and end stops 2 Nos in each opening etc complete all as specified and directed.
Preparation of new wood surfaces over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer all as specified and directed.
Preparation of new steel surfaces over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer all as specified and directed.
12mm thick prelaminated termite resistant water proofing plywood interior grade, prelaminated one side with decorative choice lamination and other side balancing white lamination, fixed with screws to timber frame work, fixed in repairs all as specified and directed.
18mm thick prelaminated termite resistant water proofing plywood interior grade, prelaminated one side with decorative choice lamination and other side balancing white lamination, fixed with screws to timber frame work, fixed in repairs all as specified and directed.
Anodised aluminium door shutters, aluminium section weighing 0.55 Kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading screws etc complete all as specified and directed. Note: Glazing, particle board and wire mesh shall be measured and paid separeatly.
Plain sheet glass 4.8mm thick ordinary quality and glazing with oil putty in square exceeding 0.5 Sq.m in each pane complete all as specified and directed.
Door closer aluminium (extruded section) body hydraulically regulated designation No.3 universal type suitable for door shutters of 851 to 1000 mm in width and weight between 61 to 80 kg and fixed complete all as specified and as directed.
Double action floor spring hydraulically regulated made up of minium 1.25mm thick alluminium alloy sheet foundation box, main body with stainless steel cover governing pivot made of brass other parts made up of mild steel heavy duty and fixed all as specified and directed.
Health faucet (Jet Spray ) Brass CP, 15mm dia with flexible pipe 1m long and fixing nut etc complete fixed in repairs all as specified and directed.
PVC valveless syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets of 10 litre capacity, fixed in repairs all as specified and directed.
Sinks with drainage board fixed in repairs made of stainless steel 1mm thick, kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm all as specified and directed.
Brass chromium plated shower rose 100 to 125 mm size, with (or) without swivel joints type with arm, including fixing to 15mm dia pipe or union fixed in repairs all as specified and directed.
Vitreous china wash basin, white, flat back, size 550 x 400mm including cutting for and pinning in ends of brackets but exclusicve of fixing of and waste pipe complete fixed in repairs all as specified and directed.
Vitreous china wash basin, white, flat back, size 450 x 300mm including cutting for and pinning in ends of brackets but exclusicve of fixing of and waste pipe complete fixed in repairs all as specified and directed.
Vitreous China, squatting pan, ”ORISSA PATTERN” size 580x 440 mm white with integral foot rest (excluding flushing cistern and flush pipe), P trap / S trap complete, fixed in repairs all as specified and directed.
Vitreous China, wash down water closet pan (Pedestal pattern), white (excluding flushing cistern and flush pipe) complete fixed in repairs all as specified and directed.
Bib taps of cast copper alloy fancy type chromium plated screwed down, screwed for iron pipe or for brass ferrule and fixed 15mm bore, fixed in repairs all as specified and directed.
Pillar taps, fancy type, 15mm dia cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts, screwed for iron pipe all as specified and directed.
Stop / angle valves, 15mm dia, fancy type chromium plated cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed in repairs all as specified and directed.
Stop valves, 15mm dia for shower rose, fancy type, with long shank and cup concealed type, chromium plated cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed in repair all as specified and directed
20mm dia Gunmetal, globe or gate valves with iron wheel head, screwed both ends for iron pipe and fixed in repairs all as specified and directed.
32/40mm dia expandable type PTMT waste pipe for wash hand basin/ kitchen sink including fixed in repairs complete all as specified and directed.
Gunmetal gate valve with iron wheel head screwed both ends for iron pipe of size 25mm dia fixed in repairs all as specified and directed.
PVC connections 15mm size with PTMT nuts of length 450mm and fixed in repairs complete all as specified and directed.
15mm dia chromium plated cast copper alloy fancy type, two in one combination of bib tap and angle valve fixed in repairs all as specified and directed.
Taking up or down steel / PVC tubing and connections, bore of pipe upto 15 mm, all as specified and directed.
15mm bore unplasticised PVC pipes including fittings of pressure rating 10 Kgf/cm² laid and fixed complete to walls and ceilings or laid in floors all as specified and directed.
Taking up or down steel / PVC tubing and connections, bore of pipe upto 20 mm, all as specified and directed.
20mm bore unplasticsed PVC pipes including fittings of pressure rating 10 Kgf/cm² laid and fixed complete to walls and ceilings or laid in floors all as specified and directed.
Taking up or down steel / PVC tubing and connections, bore of pipe upto 40 mm, all as specified and directed.
40mm bore unplasticsed PVC pipes including fittings of pressure rating 10 Kgf/cm² laid and fixed complete to walls and ceilings or laid in floors all as specified and directed.
Dismantling and removing water tanks of capacity exceeding 250 ltrs and not exceeding 500 ltrs all as specified and directed.
Dismantling and removing water tanks of capacity exceeding 500 ltrs and not exceeding 1000 ltrs all as specified and directed.
Rotational moulded polyethylene water storage tanks, ISI marked three layer (cylindrical vertical with closed top) hoisted and fixed in position, 500 ltrs capacity all as specified and directed.
Rotational moulded polyethylene water storage tank, ISI marked three layer (cylindrical vertical with closed top) of capacity 1000 ltrs hoisted and fixed in position all as specified and directed.
PVC (SWR) pipes 110 mm bore single socketed in any length with rubber ring joints laid in trenches or in floors or wall with necessary clamps all as specified and as directed.
PVC (SWR) pipes 75mm bore single socketed, in any length with rubber ring joints, laid in trenches or in floors or wall with necessary clamps all as specified and directed.
Dismantling wall and ceiling board (fibre, pulp, insulation etc) or insulation boards / slabs / blankets, any thickness, including cover fillets including frame work all as specified and directed.
False ceiling using GI snap grid system with roll-formed out of hot-dip galvanised steel capping (powder coated), main runner 38x24mm, cross Tee 29x24mm and wall angle 24x24mm and thickness not less than 1 mm, members suspended with Hangers 4 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long , with 4mm thick designer ceiling board of any texture (Lake & hill, Oceanic, cascade or Electra) as approved by GE, all as per Everest Ceiling grid system "Regular T-2430" or its equivalent make of "Ramco/ Charminar/ Armstrong" all as specified and directed. Note: Suspenders of GI wire 4mm dia shall be provided at 1200mm centre to centre alongwith telescopic adjustable fastening system (nut & bolt) of minimum 6mm dia.
Demolition of Brickwork, stone / boulder masonry built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and directed
Brick work with sub class ‘B’ bricks, burnt clay bricks straight or curved on plan exceeding 6 mtr mean radius built in cement mortar (1:6) all as specified and directed.
Taking down cement or cement lime plaster, any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc, complete all as specified and as directed.
Rendering 15mm thick on fair face of brick wall / concrete surfaces in cement mortar 1:6 finished even and smooth without using extra cement all as specified and directed.
Preparation of newly plastered surfaces of walls and applying three coats of white wash all as specified and directed.
Applying two coats of oil bound distemper on surfaces of walls over and including two coats of wall care putty including removal of existing treatment and applying a coat of priming paint on old wall surfaces all as specified and directed.
Demolition of cement concrete in ground floors (including tiles / floor finishes) and paving not exceeding 15cm thickness (below or above GL) all as specified and directed.
Dismantling of floor, hearth or wall tiling including cement mortar bedding all as specified and directed.
sunken floor treatment by providing injection pressure grouting treatment using cement slurry mixed with grout admixture non shrink additive using 40 PSI pump complete and applying two coats of brush bound acrylic polymer modified cement based coating thickness 1mm or two coat of pidifin 2K acrylic polymer water coating including necessary surfce, preparation, providing 20mm thick water proofing screed bed / plaster in cement mortar 1:4 mixed with conplast x 42IC @ 100ml or pidiproof LW @ 200ml per bag cement. Two coats of Nitro proof 100 bitumen based water proofing over plastered surface complete all as specified of chemical resistant coating complete all as specified and directed. Note: The work shall be executed through authorised applicator of M/s Fosroc/ Pidilite using the amterials supplied by M/s Fosroc chemicals India Pvt Ltd or M/s Pidilite Industrial Ltd and in accordance with their resective manufacturers instructions.
300mm thick lime concrete with lime mortar 1:3 mix and 40mm graded brick aggregate in sub floors.
Screed bed or bedding layer of cement mortar 15mm thick (1:4) for laying floor finishes all as specified and directed.
Non - skid Ceramic tiles, coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed.
Coloured glazed ceramic tiles 300 x 200 x 6-7mm thick as in skirting / dado set and jointed in neat cement slurry and pointed in coloured cement to match colour of the tile complete all as specified and directed.
25mm thick plain cement concrete type B1 1:2:4 using 20mm graded stone aggregate as in sub floor, sub bases, floors and pavings etc complete all as specified and directed.
Backing coat / screed 10mm thick in cement mortar 1:3 on fair faces of brick / stone wall surfaces complete all as specified and directed.
Cast iron floor trap 75mm dia with grating including jointing to waste pipe fixed in cement concrete type B-1, 1:2:4 all as specified and directed.
Cast iron nahani trap 75mm dia with grating including jointing to waste pipe fixed in cement concrete type B-1, 1:2:4 all as specified and directed.
Dismantling Asbestos cement (corrugated, semi corrugated, etc) sheets in roof covering all as specified and directed.
Pre-painted galvalume aluminium zinc coating GI based corrugated sheet 0.50 mm thick of any colour having tensile strength 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws all as specified and directed.
Pre-painted galvalume aluminium zinc coating GI based plain sheet 0.50 mm thick of any colour having tensile strength 550 Mpa as in ridges fixed with self tapping screws all as specified and directed.
Dismantling of Wrought iron or Mild steel work of any description not otherwise provided for such as fencing posts, gates, etc complete all as specified and directed.
Mild steel works in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle) including distance pieces, cleats etc.of grade Fe-410-W (Gde-E-250) quality-A all as specified and directed.
Rolled Mild Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified and directed.
Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment con- forming to Fe.290.Gde-E-165 all as specified and directed.
Framed work as in doors or gates of angle or other section with gussest plates, rails, braces, etc, complete drilled for fixing of steel sheeting or other covering doors etc, to be prepared for hanging and sliding with and including either hooks and hinges or steel hnging door fittings and slidding bolt/ tower bolt (exclusive of steel sheeting or other covering, running rails and guides) and hanging also fastening and fixing complete conferming to gde Fe 410 (Gde E-250) fixed in position all as specified and directed.
Pre-cast cement concrete block masnory with solid block exceeding 10cm in width and setting in cement mortar 1:6 type C1 1:3:6 using 20mm graded stone aggregate complete all as specified and directed
Rendering 15mm thick in cement mortar 1:4 on fair face of brick work or concrete surfaces finished even and smooth without using extra cement all as specified and directed.
100mm thick hard core using broken stone, broken to gauge not exceeding 63mm all as specified and directed.
75mm thick PCC 1:3:6 type C2 (using 40mm graded stone aggregate) as in plinth protection / path, laid and finished in bays not exceeding 3m c/c and filling the joints with mastic bitumen complete all as specified and directed.
100mm thick PCC (1:4:8) type D2 using 40mm graded stone aggregate as in sub base and finished even and fair complete all as specified and directed.
Chequered cement concrete tiles with grey cement and pigments, of size 300x300mm x 25mm thick set, jointed and pointed in neat cement slurry in floor including 15mm thick screed bed in cement mortar 1:4 all as specified and directed.
Machine Pressed precast concrete interlocking paver block rubberised any shape and size conforming to IS- 15658 - 2006 of 60 mm thickness M-35 Grade with grey cement and pigment including finishing the outer edge with cement concrete 1:2:4 using 20mm graded aggregate complete all as specified and directed.
Sand filling under floors or in foundations including watering and consolidation all as specified and directed.
Applying three coats of cement base paint over a coat of primer on newly plastered surfaces of wall including preparation of surfaces all as specified and directed.
Cleaning the existing SGSW/ CI /PVC (SWR) sewage Pipe line of any dia by mechanical means by rodding, jetting and removing all sludge and foreign matters completely and neatly from the pipe line under foul condition (including lines and manholes under blocked/ choked condition) and making the sewage lines serviceable for free flow of sewage including blocking of higher level manholes, washing with fresh water to the cleaned line by means of hydraulic/ pneumatic/ vacuum water jet etc all as specified and directed. These operation shall be carried out strictly in conformity with the provisions of 'Manual scavenging (Prohibition) Act and by following all mandatory safety provisions.
Cleaning of manholes of any size and depth up to 2.00 mtrs under foul condition, by removing MH covers, removing of accumulated liquid, sludge/ sediments by mechanical means, transporting the fluid/ sludge etc in covered containers by mechanical means and disposing of the same in CPCB approved central STP/ ETP facility. Cleaning of the manholes with fresh water and white washing inside MH, including petty repairs of cement mortar/ cement concrete (type B-1 1:2:4 using 20 mm graded aggregate and) patch work on holes if any made by rodents and making good to walls, placing the MH covers back intact in position and setting in cement mortar 1:6 all as specified and directed.
Cleaning and removing individual blockages in IWC/ EWC mechanically and removing all sludge and foreign matters completely, neatly and making serviceable for free flow all as specified and directed.
All as per Item No. 105 hereinbefore, but for Gully trap / nahani trap / floor trap etc including opening the gratings and replacing the covers / gratings in position and making good complete all as specified and directed.
Cleaning of septic tank / sewage sump / soak well by removing of sludge and sediments in dry or mud state by machanical means, transporting the fluids / sludge etc in covered containers machanically and burying the same in pits where directed including necessary excavation, refill and disposal of surplus soil etc, complete, cleaning of septic tank with water, placing the covers intact and removing bush / vegatation near by septic tank to and extent of 3M all round and removing of sewage water from septic tank/ sewage sump/ soak well through septic tank cleaning lorries having pumping arrangement and carrying the sewage water in tanks of lorry having 5000 liters capacity and disposal of the sewage water 15Km away from outside defence area in the places upproved by local municipality / corporation complete all as specified and directed.
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.50M in depth; for foundation, etc. not exceeding 10 sq m on plan and not exceeding 1.5 m in depth and getting out in hard/ dense soil complete all as specified and directed.
Demolition and breaking up drain pipe (salt glazed drain pipes, AC or RCC) set in cement mortar internal dia of pipes 150mm / 110mm including under and haunching of cement concrete all as specified and directed.
160mm (outer dia) PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floors or in walls all as specified and directed.
150mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in drain all as specified and directed.
PVC (SWR) gully traps 125 x 110mm, setting and jointing with solvent cement including concrete pedestal etc complete all as specified and directed.
PVC (SWR) bends any radius, 110mm bore all as specified and directed.
PVC (SWR) bends any radius, 110mm bore with access door all as specified and directed.
110mm dia PVC (SWR) junction single, (Single T) equal or unequal with access door all as specified and directed.
Concrete bed to 150mm/ 160mm bore drain pipes in PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) including packing under and haunching against the side of pipes after they are laid and tested all as specified and directed.
Concrete bed to 110mm bore drain pipes in PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) including packing under and haunching against the side of pipes after they are laid and tested all as specified and directed.
Returning, filling in, including spreading, watering and well ramming in layers not exceeding 25 cm thick using soils all as specified and directed.
Removing excavated material to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point as in soils all as specified and directed.
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for all as specified and as directed.
PCC 1:4:8 type D2 using 40mm graded stone aggregate as in foundations filling and mass concrete all as specified and directed.
PCC 1:3:6 type C2 using 40mm graded stone aggregate as in surface channels and drains all as specified and directed.
Providing plain cement concrete type B1 1:2:4 using 20mm graded stone aggregate as in benching / copings including necessary formwork all as specified and directed.
Mild steel TMT bars 8mm dia and over cut to length, bent to shape required, incl cranking, bending spirally for hooping for columns, hooking ends and binding with and incl mild steel wire (annealed) not less than 0.90mm dia or securing with clips all as specified and directed.
Precast cement concrete, type B1, 1:2:4 using 20mm graded stone aggregate, set in cement mortar 1:4 as in cover slabs all as specified and directed. Note: Reinforcement shall be measured and paid separately.
R K BUILDERS
Narendran Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .