| 1 | L1₹10.7 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹10.8 L+₹14,835.25 (1.39%)Rejected-Finance 27 2387 A CHITTUTHARA SASTRI NAGAR SMARTO ROAD KADAVANTHARA KOCHI 682 020 | ERNAKULAM | KERALA | 682020 | L2 | Rejected-Finance NOT BEING LOWEST TENDERER | |
| 3 | L3₹10.8 L+₹15,155.35 (1.42%)Rejected-Finance D NO CC XX 1487 B1 CC 18 1786 B1 NEAR VVLP SCHOOL KONAM PALLURUTHY P O KOCHI 682006 | ERNAKULAM | KERALA | 682006 | L3 | Rejected-Finance NOT BEING LOWEST TENDERER | |
| 4 | L4₹11.2 L+₹49,466.15 (4.64%)Rejected-Finance KATTUPADATH H AZHEEKAL PO VYPEEN 682508 | KOCHI | ERNAKULAM | KERALA | 682508 | L4 | Rejected-Finance NOT BEING LOWEST TENDERER | |
| 5 | L5₹11.3 L+₹67,243.55 (6.31%)Rejected-Finance 22 1685 ST JACOB CHURCH LANE PAMBAIMOOLA EDACOCHIN ERNAKULAM KERALA 682010 | ERNAKULAM | ERNAKULAM | KERALA | 682010 | L5 | Rejected-Finance NOT BEING LOWEST TENDERER |
Tender Value
₹11.5 L
EMD Value
₹23,000
Closing Date
1 May 2023, 6:00 pmClosed
GE FORT KOCHI
GARRISON ENGINEER MILITARY ENGINEER SERVICES GE FORT KOCHI -682 001
SPECIAL REPAIRS TO FLOORING IN BUILDING NO. P-49 AT SMA RAMESWARAM.
2023_MES_586193_1
8907/E8/GE_FORT_KOCHI
Open Tender
Civil Works
Item Rate
180 days
FORT KOCHI
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE FORT KOCHI
₹23,000
Yes
5 Aug 2023
17 Mar 2023
4 May 2023
17 Mar 2023
1 May 2023
10 Apr 2023
Amount
M & L for moorum/red bajri filling in floors or pavings , laid in layers not exceeding 15 cm thick, spread, levelled and rammed including watering complete all as specified and as directed.
M & L for hardcore filling in floors of guage exceeding 63mm but not exceeding 100 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rolled/rammed to a true surface complete all as specified and as directed.
M & L for plain cement concrete in foundations, filling and mass concrete Type E2 1:5:10 (40mm graded aggregate) complete all as specified and as directed.
M & L for coloured ceramic glazed tiles (600x600mm) 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry over and including 15 mm thick screed bed in CM 1:6 and pointed in white or coloured cement to match,complete all as specified and as directed.
M & L for Non - skid Ceramic tiles (300x300mm) 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry over and including 15mm thick screed bed in CM 1:6 and pointed in white or coloured cement to match complete all as specified and as directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specified and as directed.
M & L for reinforced cement concrete Type B1 1:2:4(20 mm graded aggregate) as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed.
M & L for TMT steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M & L for TMT steel bars 8 mm dia in stirrups, spacers and binders, , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clip complete all as specified and as directed.
M & L for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and as directed.
M&L brickwork with subclass ‘B’ bricks, straight or curved on plan exceeding 6m mean radius built in cement mortar (1:6) complete all as specified and as directed.
Taking down & refixing in other opening of chowkhats or frames not exc. 1.5 sq. m each with shutters (without taking off shutters from the frames) complete all as specified and as directed.
S & F for bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and as directed.
M & L for preparation of old painted wooden surfaces of any description , not otherwise described over 10cm width or girth and applying one coats of synthetic enamel (ordinary tint) paint complete all as specified and as directed.
M & L for Rendering 10mm thick on fair faces of brick work or concrete surfaces using cement plaster of 1:4 complete all as specified and as directed.
M & L for preparing new surface walls, plastered or unplastered, and two coats of distempering walls with oil bound distemper, white or tinted over a coat of primer alkali resistant priming paint complete all as specified and as directed.
M & L for preparing old surface walls, plastered or unplastered, and single coat of distempering walls with oil bound distemper, white or tinted complete all as specified and as directed.
M & L for preparing old surface ceiling, plastered or unplastered, and single coat of distempering walls with oil bound distemper, white or tinted complete all as specified and as directed.
Disconnecting the existing pedestal pan and trap and refixing the same including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe, etc.complete all as specified and as directed.
Disconnecting the existing urinal and refixing Urinal, bowl type or half stall pattern, basin only including connections to flushing pipe and outgoing pipes fixed for complete all as specified and as directed.
S & F of Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and as directed.
M & L of steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified and as directed.
M & L for preparation of new surfaces of any description, over 10cm in width or girth,not otherwise and applying two coat of synthetic enamel paint over a red oxide or zinc chrome primer complete all as specified and as directed.
S & F of framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed.
Aarjay Tech Engineering
COCHIN CHEMICALS
MS BUILDERS
ZOOM ENTERPRISES
REIGN CONSTRUCTIONS
SOORYA ASSOCIATES
M/s.Rejoy Constructions
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .