Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.7 CrAccepted-AOC | ₹1.7 Cr Quoted ₹1.8 Cr | 1 | Accepted-AOC M/s Raj Shyama Construciton Pvt Ltd |
| 2 | 2₹1.8 Cr+₹3.1 L (1.70%)Rejected-Finance 112 RADHEY SHYAM VIHAR PHASE II MURAD NAGAR GHAZIABAD UP | GHAZIABAD | UP | ₹1.8 Cr+₹3.1 L (1.70%) | 2 | Rejected-Finance Bidder are Second |
| 3 | 3₹1.9 Cr+₹12.4 L (6.89%)Rejected-Finance B 163 SWARN JAYANTI PURAM GHAZIABAD GHAZIABAD GHAZIABAD GHAZIABAD UTTAR PRADESH 201001 | GHAZIABAD | UTTAR PRADESH | 201001 | ₹1.9 Cr+₹12.4 L (6.89%) | 3 | Rejected-Finance Bidder are Third |
Tender Value
Refer Docs
EMD Value
₹3.2 L
Closing Date
30 Jan 2023, 11:00 amClosed
Superintending Engineer
Bijli Bhawan Bazpur Road Kashipur
Construction of Single CKT under ground 33 KV 3x400 mm from 33/11 KV Sub Station Mahuwakheraganj to 33/11 KV Sub Station Mahuwakheraganj I under EDD Kashipur on Turnkey Basis
2022_UPCL9_52954_1
E Tender No 39/EDC(K)2022-23
Open Tender
Electrical Works
Turn-key
180 days
Kashipur Rural
As Per Tender NIT and Tender Documents
3 documents required · 3 mandatory
₹11,800
Yes
EE EDD Kashipur
₹3.2 L
Yes
20 Jul 2023
21 Dec 2022
31 Jan 2023
21 Dec 2022
30 Jan 2023
21 Dec 2022
Supply Item
Supply of 33 KV XLPE Cable 3x400 Sq.mm. (As per Specification & Drawing of UPCL)
Supply of 33 KV 3x400 Sq.mm XLPE Outdoor Cable Jointing Kit. (As per Specification & Drawing of UPCL)
Supply of 33 KV 3x400 Sq.mm XLPE Cable Straight Through. (As per Specification & Drawing of UPCL)
Supply of 33 KV Class Polymeric Pin insulator with hardware. (As per Specification & Drawing of UPCL)
Supply of Steel Tubler Pole SP-33 (Galvanized) (As per Specification & Drawing of UPCL)
Supply of M.S Channel (125x65x6) (As per Specification & Drawing of UPCL)
Supply of M.S Channel (100x50x6) (As per Specification & Drawing of UPCL)
Supply of M.S Angel (65x65x6) (As per Specification & Drawing of UPCL)
Supply of M.S Angel (75x75x6) (As per Specification & Drawing of UPCL)
Supply of M.S Angel (50x50x6) (As per Specification & Drawing of UPCL)
Supply of 33 KV Polymer Disc Insulator (B&S) Type (As per Specification & Drawing of UPCL).
Supply of 33 KV Disc Fitting (B&S) Type 90 KN for Panther (As per Specification & Drawing of UPCL).
Supply of Stay Set GI 16x1800 mm (As per Specification & Drawing of UPCL).
Supply of Stay wire 7/3 15 mm 7 SWG (As per Specification & Drawing of UPCL).
Supply of 33 KV VCB 1250 A 24 V (As per Specification & Drawing of UPCL).
Supply of 33 KV CT Outdoor (As per Specification & Drawing of UPCL).
Supply of 33 KV Line Isolator with Earth Switch (As per Specification & Drawing of UPCL).
Supply of 33 KV Bus Isolator (As per Specification & Drawing of UPCL).
Supply of 33 KV L.A (As per Specification & Drawing of UPCL).
Supply of 33 KV Post Insulator (As per Specification & Drawing of UPCL).
Supply of Control Panel FDR Double CKT (As per Specification & Drawing of UPCL).
Supply of ACSR Panther Conductor (As per Specification & Drawing of UPCL).
Supply of Unarmoured Control Cable 2.5 Sq mm 2 Core (As per Specification & Drawing of UPCL).
Supply of Unarmoured Control Cable 2.5 Sq mm 4 Core (As per Specification & Drawing of UPCL).
Unarmoured Control Cable 2.5 Sq mm 10 Core (As per Specification & Drawing of UPCL).
Supply of G.I Earth Strip (35x6 mm) (As per Specification & Drawing of UPCL).
Supply of Earth Rod (20x2500 mm) (As per Specification & Drawing of UPCL).
Supply of Earth wire (GI 7/1.6 mm 16 SWG) (As per Specification & Drawing of UPCL).
Supply of HDPE Pipe PE 100 PN6 & having dia 200 mm conferning to IS 4984/1995 & having thickness 9.1 to 10.3 mm for cable 3x400 sq mm. (As per Specification & Drawing of UPCL)
Supply of G.I pipe 200 mm dia. (As per Specification & Drawing of UPCL).
Supply of PP clamp for ST Pole SP-33 (made of MS flat 75x10 mm) with Nut & Bolt (As per Specification & Drawing of UPCL).
Supply of Bracing clamp for ST Pole SP-33 (made of MS flat 65x6 mm) with Nut & Bolt (As per Specification & Drawing of UPCL).
Supply of E clamp for ST Pole SP-33 (made of MS flat 75x10 mm) with Nut & Bolt (As per Specification & Drawing of UPCL).
Supply of RCC Cable Line Route Marker withwriting, painting and numbering etc. (As per Specification & Drawing of UPCL).
Supply of Stay Clamp with N&B (As per Specification & Drawing of UPCL).
Supply of Red Oxided Paint
Supply of Al. Paint
Supply of PG Clamp for Panther to Panther (As per Specification & Drawing of UPCL).
Supply of Isolator Clamp for Panther (As per Specification & Drawing of UPCL).
Supply of VCB Clamp for Panther (As per Specification & Drawing of UPCL).
Supply of CT Clamp for Panther (As per Specification & Drawing of UPCL).
Supply of Nut & Bolt as per Norms (As per Specification & Drawing of UPCL).
Supply of of Danger Board/ No. Plate with fixing clamps (As per Specification & Drawing of UPCL).
Supply of Barbed wire as per Norms (As per Specification & Drawing of UPCL).
33 KV XLPE Cable under ground Work
Cartage of the S.T. Pole STP-33 by truck from work site dump store approx. including loading into truck and unloading at work site.
Cartage of the 33 KV XLPE Cable 3x400 sq.mm by truck from work site dump store approx. including loading into truck and unloading at work site.
Cartage of the Small Line Material by truck from work site dump store approx. including loading into truck and unloading at work site.
Excavation of Earth for Pole Pit of Size (.9x.6x1/6) of pole length in all type of soil including proper dressing of sides and ramming of bottom including getting out the excavated soil and diposal of surplus soil as directed complete work.
Erection of Duble Pole Structure of S.T. Pole SP-33 pole in proper level and alignment along with fixing of all accessories, like top channels & clamps as per Respo construction manual.
Grouting of ST pole in size (.45x.45x1/9) length of support in CC ratio 1:4:8 (1Cement:4Graded Stone:20mm nomial size:8 coarse sand) Block Including cost of material in all respect.
Muffing of ST pole in size (.45cmx.6cm) radious with CC ratio 1:3:6 (1Cement :3core sand:6 graded stone 10mm nomial size) Block size 45cm height from ground level Including cost of material in all respect.
Fabrication of Channel/angle to Single/Double/Four pole Structure Straight Cross arm T off Top and Dropper, Brecing Channel of M.S. Channel 125x65x6 mm, 100x50x6 & M S Angle 75x75x6, 65x65x6, 50x50x6 mm Cutting and Holling in all respect as per Specification of UPCL.
Fixing of M.S. earthing rod 20×2500 mm for earthing of support as per RESPO drawing No. RES-12 including digging earth rod 0.3 m deep below ground level connected to support with earth wire 16 swg fixing of all accessories in all respect as per Specification of UPCL.
Painting of SP Pole-33 of steel tubular poles with two coats of Aluminum paint Berger Luxol quality over one coat of red oxide primer and P.O. red on top above guarding angle in all respect as per Specification of UPCL.
Providing and Fixing of chemical compound pipe earthing complete with jointing of G.I. Earth strip properly welded by electric arc.
Fixing of R.C.C cable line route marker with writing painting and numbring etc.
Fixing of cable terminal Jointing Kit for 3x400 sq mm XLPE O/D.
Fixing of Straight Through cable jointing kit for 33 KV 3x400 sqmm cable XLPE.
Fixing of G.I pipe 200 mm dia on D/P Structure properly for cable Fixing etc.
Laying of 33 KV Cable in 1.5 mtr depth with suitable trencheless technology including Fixing of HDPE pipe PE 100 PN6 & having dia 200 mm conferming to IS 4984/1995 & having thickness 9.1 to 10.3 mm.
Terminal Gantry Structure work
Fabrication of Structures including welding of angel/channel, Cutting, molding, drilling etc, complete work.
Excavation of Earth soil for making structures plinth.
Providing & Laying cement, sand, concrete (1:4:8) with cement, sand, concrete, aggregate 20 mm nominal size in Foundation.
Erection of Bay/Gantry Structure and making grouting 2x1x1.4 mtr by providing and filling cement, sand, concrete, aggregate 20 mm nominal size in grouting.
Providing 15 mm thick plaster work on the grouting of bay/gantry structure in cement sand ratio 1:5 (Lanth, widhed, top)
Erection of Gantry with filling in all accessories complete in all respact.
Bus/Line Isolator Structure Plinth work
Bolts and nuts of size
Fabrication of Structures including welding of angel/channel, Cutting, molding, drilling etc, complete work.
Excavation of Earth soil for making structures plinth.
Providing & Laying cement, sand, concrete (1:4:8) with cement, sand, concrete, aggregate 20 mm nominal size in Foundation.
Erection of Bay/Gantry Structure and making grouting 1.5x1x1.4 mtr by providing and filling cement, sand, concrete (1:3:6) with cement, sand, concrete aggregate 20 mm nominal size in grouting.
Providing 15 mm thick plaster work on the grouting of bay/gantry structure in cement sand ratio 1:5 (Lanth, widhed, top)
Erection of 33 KV Line/Bus Isolator with filling in all accessories complete in all respact.
CT/Post Insulator Structure Plint work
Fabrication of Structures including welding of angel/channel, Cutting, molding, drilling etc, complete work.
Bolts and nuts of size
Excavation of Earth soil for making structures plinth.
Providing & Laying cement, sand, concrete (1:4:8) with cement, sand, concrete, aggregate 20 mm nominal size in Foundation.
Erection of CT and Post Insulator Structure and making grouting 1.8x4x1.4 mtr by providing and filling cement, sand, concrete (1:3:6) with cement, sand, concrete aggregate 20 mm nominal size in grouting.
Providing 15 mm thick plaster work on the grouting of bay/gantry structure in cement sand ratio 1:5 (Lanth, widhed, top)
Erection of CT and Post Insulator with filling in all accessories complete in all respact.
VCB Erection/Construction work
Cartage of VCB SF-6 with loading & unloading from store center to sub station appr. Distance 35 Km.
Excavation of Earth soil for making structures plinth.
Providing & Laying cement, sand, concrete (1:4:8) with cement, sand, concrete, aggregate 20 mm nominal size in Foundation.
Erection of VCB Structure and making grouting 1.8x4x1.4 mtr by providing and filling cement, sand, concrete (1:3:6) with cement, sand, concrete aggregate 20 mm nominal size in grouting.
Providing 15 mm thick plaster work on the grouting of bay/gantry structure in cement sand ratio 1:5 (Lanth, widhed, top)
Erection of VCB Structure with filling in all accessories complete in all respact.
Earthing of VCB Structure
Making Jumper From Bus Bar and Connection to Isolators, VCB and CT's with Complete work.
Erection of Complete Bus/Line/Isolator Structure/Plinth
Installation of 33 KV LA with complete work.
Earthing of Structures, LA and Metering cubical with 35x6 mm GI Strip with complete work.
Painting of Gantary Structure with one Coat of red oxied and two coat of enamel Al paint.
Laying of Unarmoured 2.5 Sq mm 2 Core Control Cable.
Laying of Unarmoured 2.5 Sq mm 4 Core Control Cable.
Laying of Unarmoured 2.5 Sq mm 10 Core Control Cable.
High Pressure Testing of 33 KV Line.
RP INFRAPOWER PVT LTD
Capital Electech Pvt Ltd
stage.html
html • 0.04 MB
tech_eval.pdf
PDF • 0.29 MB
boq_comp_chart.xlsx
xlsx • 0.02 MB
fin_eval.pdf
PDF • 0.54 MB
aoc.pdf
PDF • 14.08 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .