Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹3.6 CrAdmitted-Finance | -20.56% | ₹3.6 Cr | L1 | Admitted-Finance |
Tender Value
₹4.5 Cr
EMD Value
₹4.5 L
Closing Date
29 Dec 2025, 6:00 pmClosed
EE PWD SIDHI
Old RTO Office Building, Sidhi
Const. of N.H. 39 to N.H. balance work up to Vill. Mohaniya App. Road, L- 1.00 Km, Under Sub. Dn. Churhat, Distt. Sidhi PWD Road and Bridges SOR w.e.f 11-04-25
2025_PWDRB_464341_1
NIT 16 /SIDHI / 2025-26 / 04-12-2025
Open Tender
Civil Works - Roads
180 days
EE PWD SIDHI
Const. of N.H. 39 to N.H. balance work up to Vill. Mohaniya App. Road, L- 1.00 Km, Under Sub. Dn. Churhat, Distt. Sidhi PWD Road and Bridges SOR w.e.f 11-04-25
4 documents required · 4 mandatory
₹15,000
₹4.5 L
24 Mar 2026
10 Dec 2025
31 Dec 2025
10 Dec 2025
29 Dec 2025
10 Dec 2025
Scarifying existing bituminous surface to a depth of 50 mm by mechanical means Scarifying the existing bituminous road surface to a depth of 50 mm and disposal of scarified material with in all lifts and lead up to 1000 meters.
Clearing and Grubbing Road Land Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees having girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material up to a lead of 1000 meters including removal and disposal of top organic soil not exceeding 150 mm in thickness. A In area of light jungle
Embankment/ Sub Grade Construction with Material Obtained from Borrow Pits Construction of embankment with approved material having CBR>7 obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of table 300-1, 300-2 and as per relevant clauses of section300.
Providing and laying reinforced cement concrete pipe NP-4 for service ducts below concrete pavement. a) 300 mm Dia
Providing and laying reinforced cement concrete pipe NP-4 for service ducts below concrete pavement. b) 600 mm Dia
Crusher Run Macadam Sub Base/Base Course Providing crushed stone aggregate, depositing on a prepared surface by hauling vehicles, spreading and mixing with a motor grader, watering and compacting with a vibratory roller as per clause 410 to form a layer of sub-base/Base in accordance to Table No. 400-14, 400-15 and as per clause of section 407 of specifications. (ii) For 37.5 mm maximum size
Dry Lean Cement Concrete Sub- base Construction of dry lean cement concrete Sub- base over a prepared sub-grade or drainage layer with coarse and fine ggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver finisher with electronic sensor, compacting with 8- 10 tonnes vibratory roller, finishing and curing as per clause 601 of specification complete in all respect
Deduct from Item No.6.1 above if paver finisher with electronic sensor is not used and laying, (The acceptance criteria regarding level, thickness, surface regularity, texture finish, strength of concrete and all other quality control measures shall be the same as in case of machine laid work.)
Cement Concrete Pavement Construction of un-reinforced, dowel jointed, plain cement concrete pavement with M-30 grade concrete over a prepared sub base with cement , coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with electronic sensor slip form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, admixtures as approved, curing compound, finishing to lines and grades as per drawing as per IRC-15-2011 and as per relevant clauses of section 602 of specifications complete but excluding cost of steel in dowel bars and tie rods etc. including groove cutting for width of 4 mm- 6mm and 1/3rd depth of PQC within 8-10 hrs of placing/ finishing of PQC including cost of cutting including cleaning of groove and providing approved sealant filling etc. as per clause 602.2.10 and 600.10 and IRC-57-2006 as per drawing and as per specification.
Deduct from Item No.6.3 & 6.4 above if slip form paver with electronic sensor is not used and laying, compaction is done by fix form paver having 60 mm vibratory needle @ 2 Nos. per metre. (The acceptance criteria regarding level, thickness, surface regularity, texture finish, strength of concrete and all other quality control measures shall be the same as in case of machine laid work.)
Providing and fixing Steel in dowel bar and tie rod including craddle, laps etc. complete required as per design. (a) Mild steel confirming to IS: 432:1982
Providing and fixing Steel in dowel bar and tie rod including craddle, laps etc. complete required as per design. (b) Tor steel confirming to IS: 1786:2008
2022 and Table 800-1 of MoRT &H specification and High Intensity Micro Prismatic Grade Sheeting shall conform to Table 6.6 of IRC:67:2022 and Table 800-3 of MoRT &H specification of in the clause 6.8 of the IRC 67-2022 and clause 801.3.7 of MoRT&H message legend numerical letter etc. and borders shall be screen printed on high intensity micro prismatic sheeting shall conform to clause 801.3.7 with digital printing ink or of cutout from transparent durable overlay or cutout from the same type of reflecting sheeting for cautionary/ mandatory/ signs, supported on MS sign post of size 75mm x75mm x 6mm of 3.60 meter over all length and fix to ground by means of properly designed foundation of dimension 450x450x600mm with M20 grade concrete. The ACM sheet shall be fixed to the post with four minimum four number breakaway bolts. & supported with a back-support frame of 25mmx25mmx3mm angle. 7 years warranty for Retro Reflection Sheeting to be provided from the original sheeting manufacture brand like 3M/Avery Dennison/ Orafol Make as per clause 6.9 of IRC: 67:2022 & a certified copy for three years for outdoor exposure report from an independent test lab as per clause 6.7 of IRC: 67:2022 for the product offered shall be submitted by the contractor. Note: - Manufacture name and date of manufacture is to be printed (Embossed) at the backside of the board. 60 cm circular
Kilo Metre Stone Reinforced cement concrete M15grade kilometre stone of standard design as per IRC:8-1980, fixing in position including painting andprinting etc (ii) Ordinary Kilometer stone (Precast)
Kilo Metre Stone Reinforced cement concrete M15grade kilometre stone of standard design as per IRC:8-1980, fixing in position including painting andprinting etc (iii) Hectometer stone (Precast)
Retro- reflectorised Traffic signs Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign board as per IRC 67-2022 made of high intensity Micro-Prismatic Grade Sheeting (Type IV) vide IRC : 67:2022 clause 6.7.3.2 and clause 801.3.3 of MoRT &H fixed over Aluminum composite material sheet with thermoplastic core of Low density polyethylene (LDPE) between two thick skins/sheets of aluminum with overall thickness of 4mm and aluminum skin of thickness 0.3 on both side, the ACM shall conform to Table 6.1 of IRC:67:2022 and Table 800-1 of MoRT &H specification and High Intensity Micro Prismatic Grade Sheeting shall conform to Table 6.6 of IRC:67:2022 and Table 800-3 of MoRT &H specification of in the clause 6.8 of the IRC 67-2022 and clause 801.3.7 of MoRT&H message legend numerical letter etc. and borders shall be screen printed on high intensity micro prismatic sheeting shall conform to clause 801.3.7 with digital printing ink or of cutout from transparent durable overlay or cutout from the same type of reflecting sheeting for cautionary/ mandatory/ signs, supported on MS sign post of size 75mm x75mm x 6mm of 3.60 meter over all length and fix to ground by means of properly designed foundation of dimension 450x450x600mm with M20 grade concrete. The ACM sheet shall be fixed to the post with four minimum four number breakaway bolts. & supported with a back-support frame of 25mmx25mmx3mm angle. 7 years warranty for Retro Reflection Sheeting to be provided from the original sheeting manufacture brand like 3M/Avery Dennison/ Orafol Make as per clause 6.9 of IRC: 67:2022 & a certified copy for three years for outdoor exposure report from an independent test lab as per clause 6.7 of IRC: 67:2022 for the product offered shall be submitted by the contractor. Note: - Manufacture name and date of manufacture is to be printed (Embossed) at the backside of the board. ii) 90 cm equilateral triangle
Retro- reflectorised Traffic signs Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign board as per IRC 67-2022 made of high intensity Micro-Prismatic Grade Sheeting (Type IV) vide IRC : 67:2022 clause 6.7.3.2 and clause 801.3.3 of MoRT &H fixed over Aluminum composite material sheet with thermoplastic core of Low density polyethylene (LDPE) between two thick skins/sheets of aluminum with overall thickness of 4mm and aluminum skin of thickness 0.3 on both side, the ACM shall conform to Table 6.1 of IRC:67:2022 and Table 800-1 of MoRT &H specification and High Intensity Micro Prismatic Grade Sheeting shall conform to Table 6.6 of IRC:67:2022 and Table 800-3 of MoRT &H specification of in the clause 6.8 of the IRC 67-2022 and clause 801.3.7 of MoRT&H message legend numerical letter etc. and borders shall be screen printed on high intensity micro prismatic sheeting shall conform to clause 801.3.7 with digital printing ink or of cutout from transparent durable overlay or cutout from the same type of reflecting sheeting for cautionary/ mandatory/ signs, supported on MS sign post of size 75mm x75mm x 6mm of 3.60 meter over all length and fix to ground by means of properly designed foundation of dimension 450x450x600mm with M20 grade concrete. The ACM sheet shall be fixed to the post with four minimum four number breakaway bolts. & supported with a back-support frame of 25mmx25mmx3mm angle. 7 years warranty for Retro Reflection Sheeting to be provided from the original sheeting manufacture brand like 3M/Avery Dennison/ Orafol Make as per clause 6.9 of IRC: 67:2022 & a certified copy for three years for outdoor exposure report from an independent test lab as per clause 6.7 of IRC: 67:2022 for the product offered shall be submitted by the contractor. Note: - Manufacture name and date of manufacture is to be printed (Embossed) at the backside of the board. iv) 60 cm equilateral triangle
Retro- reflectorised Traffic signs Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign board as per IRC 67-2022 made of high intensity Micro-Prismatic Grade Sheeting (Type IV) vide IRC : 67:2022 clause 6.7.3.2 and clause 801.3.3 of MoRT &H fixed over Aluminum composite material sheet with thermoplastic core of Low density polyethylene (LDPE) between two thick skins/sheets of aluminum with overall thickness of 4mm and aluminum skin of thickness 0.3 on both side, the ACM shall conform to Table 6.1 of IRC:67:
Direction and Place Identification signs more than 0.9 sqm size board. Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign board as per IRC 67-2022 made of high intensity Micro-Prismatic Grade Sheeting (Type IV) vide IRC: 67:2022 clause 6.7.3.2 and clause 801.3.3 of MoRT&H fixed over Aluminum composite material sheet with thermoplastic core of Low density polyethylene (LDPE) between two thick skins/sheets of aluminum with overall thickness of 4mm and aluminum skin of thickness 0.3 on both side, the ACM shall conform to Table 6.1 of IRC:67:2022 and Table 800-1 of MoRT&H specification and High Intensity Micro Prismatic Grade Sheeting shall conform to Table 6.6 of IRC:67:2022 and Table 800-3 of MoRT&H specification of in the clause 6.8 of the IRC 67-2022 and clause 801.3.7 of MoRT&H message legend numerical letter etc. and borders shall be screen printed on high intensity micro prismatic sheeting shall conform to clause 801.3.7 with digital printing ink or of cutout from transparent durable overlay or cutout from the same type of reflecting sheeting for cautionary/ mandatory/ signs, supported on 2 nos. of MS sign post of size 75mm x75mm x 6mm of 3.60 meter over all length and fix to ground by means of properly designed foundation of dimension 450x450x600mm with M20 grade concrete. The ACM sheet shall be fixed to the post with four minimum four number breakaway bolts. & supported with a back-support frame of 25mmx25mmx3mm angle. 7 years warranty for Retro Reflection Sheeting to be provided from the original sheeting manufacture brand like 3M/Avery Dennison/ Orafol Make as per clause 6.9 of IRC: 67:2022 & a certified copy for three years for outdoor exposure report from an independent test lab as per clause 6.7 of IRC: 67:2022 for the product offered shall be submitted by the contractor.
Excavation for Structures Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom as per relevant clauses of section 300 & 2100 in I Ordinary soil ( including back filling with approved material) (i) Depth upto 3 m
Metal Beam Crash Barrier - Type - B, "THRIE" : Metal Beam Crash Barrier (Providing and erecting a "Thrie" metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 85 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, however 5 spaces of 600mm each between vertical post and 5 spaces of 900mm each between vertical post will be kept adjacent to RCC parapet/ concrete crash barrier in accordance to figure 9.14 of the IRC-SP: 73-2018 2 m high with 1.15 m below ground level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a space of channel section 150 x 75 x 5 mm, 546 mm long complete as per clause 811) and treatment for metal beam cresh barrier on approach shall be modified eccentric loader terminal arrangement as shown in figure 9.12 of IRC- SP : 73-2018 End portion of metal beam crash barrier shall be flared outside by 1.25 mtr. Distance in last section of 8 mtr. Length. Departure side it shall be trailing terminal (TT) arrangement as shown in figure 9.13 of the IRC SP-73-2018. End portion of metal beam crash barrier shall be flared outside by 0.35 mtr. Distance in last section of 8 mtr. Length.
PCC M-15 in Foundation Plain cement concrete M-15 mix with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days. as per MORT&H Specification 409.
Providing P.C.C. M-15 Nominal mix for hume pipe culverts in foundation and sub structure etc. as per drawing and as per relevant clauses of section 1500, 1700, 2100 and 2900.
Providing and Laying Reinforced Cement Concrete Pipe NP4/prestrssed concrete pipe on first class bedding in single row. Providing and Laying Reinforced cement concrete pipe NP4/prestrssed concrete pipe for culverts on first class bedding of granular material (cost of bedding included) in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets B 1000 mm dia
Providing and Laying Reinforced Cement Concrete Pipe NP 4 /prestrssed concrete pipe on first class bedding in double row. Providing and Laying Reinforced cement concrete pipe NP4 /prestrssed concrete pipe for culverts on first class bedding of granular aterial (cost of bedding included) in double row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets. B 1000 mm dia
Providing Plain cement concrete M-15 nominal mix in foundation as per relevant clauses of sections 1500, 1700 and 2100.
Providing and laying Plain/Reinforced cement concrete in open foundation including form work shuttering etc. complete as per drawing and technical specifications and as per relevant clauses of sections 1500, 1700 & 2100 with. Concrete with plant (Drum Type) and placing PCC Grade M20
Providing and laying Plain/Reinforced cement concrete in open foundation including form work shuttering etc. complete as per drawing and technical specifications and as per relevant clauses of sections 1500, 1700 & 2100 with. Concrete with plant (Drum Type) and placing C RCC Grade M20
Supplying, fitting and placing HYSD bar reinforcement in sub- structure complete as per drawing and technical specifications and as per relevant clause of section 1600. FE 600
Supplying, fitting and placing HYSD bars reinforcement in superstructure complete as per confirming to IS 1786:2000 drawing and technical specifications as per relevant clauses of section 1600 (i) FE 600
Supplying, fitting and placing un-coated HYSD bar reinforcement in foundation complete as per drawing and technical specifications and as per relevant clauses of section 1600. FE 500
Taking, exploratory boring 100mm dia at the location of piers and abutments or for high embankments in approaches in all types of strata as per IRC-78-1983 and section 2400 of specifications. a) Upto 1.0 m below bed level
Providing weep holes in Brick asonry/Plain/Reinforced concrete abutment, wing wall/ return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical specifications.
hout Taxes in Rs. P
Providing and laying of Filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2 of MoRT&H specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided behind entire surface after abutment, return wall and wing wall to the full height compacted to a firm condition complete as per drawing and technical specification.
Providing and laying Pitching on slopes laid over prepared filter media including boulder apron laid dry in front of toe of embankment complete as per drawing and Technical specifications A Stone/Boulder
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.08 MB
464341Doc.pdf
Tender Documents • 18.21 MB
BOQ_549103.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid