| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹142Accepted-AOC | ₹142 Quoted ₹1.1 Cr | L1 | Accepted-AOC Awarded to lowest bidder |
| 2 | L2₹1.2 Cr+₹12.4 L (11.2%)Rejected-Finance ANAND PURA ROHTAK H NO 521 20 NEAR BAL BHAWAN ROHTAK 124001 | ROHTAK | HARYANA | 124001 | ₹1.2 Cr+₹12.4 L (11.2%) | L2 | Rejected-Finance L2 |
| 3 | L3₹1.3 Cr+₹16.6 L (15.0%)Rejected-Finance | ₹1.3 Cr+₹16.6 L (15.0%) | L3 | Rejected-Finance L3 |
| 4 | Not Admitted-Fee/PreQual/Technical H NO 13 14 NEAR HANUMAN MANDIR NEW NANDWANI NAGAR SONEPAT 131001 | SONIPAT | HARYANA | 131001 | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹1.1 Cr
EMD Value
₹2.2 L
Closing Date
22 Jan 2020, 4:00 pmClosed
SDE Civil, BPSMV
SDE Civil, BPSMV Khanpur Kalan
Renovation of Ayurveda College building and conference Hall at BPSMV, Khanpur Kalan
2019_HRY_114237_1
07
Open Tender
Civil Works
Works
180 days
BPSMV Khanpur Kalan
Please refer Tender documents.
3 documents required · 3 mandatory
₹15,000
BPSMV Khanpur Kalan
₹2.2 L
Yes
4 Mar 2020
31 Dec 2019
23 Jan 2020
31 Dec 2019
22 Jan 2020
31 Dec 2019
Amount
Dismantling brick work tile terracing or tile lining HSR. 8.5 B(in cement)
Removing door and windows (wood and steel) with chowkats by making Recesses in walls when the wall is not to be dismantled:- (HSR-8.18)A) doors
Hsr-8.18 b) window
Dismantling Roofing first class mud roofing HSR 8.8 a+c
Dismantling brick or flagged stone slab flooring without Concrete base.HSR-8.28
Distempering with washable oil bound distemper (of approved manufacture) two coats on old distempered work.( HSR :- 16.60)
Providing two coats of exterior acrylic emulsion paint. (HSR-16.79-b). 1st quality
Painting two coats with synthetic enamel Paint in all shades on old wood-work or metallic or plastered or concrete surfaces to give an even shade including rubbing down old paint. ( HSR 16.5)
scraping (a) White wash and colour wash. HSR 8.32 (a)
Scraping of Cement Plaster (HSR. 8.32 ©
15 mm thick cement plaster 1:6 on the rough side of single or half brick wall (HSR-15.12)
P & applying two coat's of Cement based J.K Birla wall putty of approved make HSR - 16.81
Applying priming coat with cement primer in all shades on newly plastered or concrete exterior surfaces. (HSR-16.25)
Providing and fixing 1st quality ceramic glazed wall tiles confirming to I.S. 15622 (thickness to be specified by the manu-facturer) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steips and dados over 12mm thick bed of cement mortar 1:3 coarse and jointed with grey cement slurry, including pointing in white cement mixed iwth pigment of matching shades complete. HSR. 14.92 (B) Size of ceramic Glazed tiles 300*450
P&F ceramic /antiskid tiles of size 400mmX400mm or above size of approved make in flooring, laid in any pattern as specified over base of 20mm thick cement coarse sand mortar 1:3 and jointed with white cement slurry mixed with pigment to match the shade of tiles Note: Tile shall be premium quality ( firest Qualitry) of reputed manufacturer like NITCPO, KAJA- RAI, SOMANI, ORIENT& JOHNSONS. ( HSR-14.91)
Terracing consisting of tiles 22.86 cm X 11.43 Cm X 3.81 cm laid over 87.50 mm mud filling on a layer of 25 mm mud plaster and on other layer of mud mortar for laying the tiles, including two coats of bitumen laid hot at 1.65 kg per sqm on top of R.C.C slab including grouting with cement sand mortar 1:3 and top surface to be left clean etc. HSR. 13.13
Cement concrete 1:2:4 gola 10 cm X 10 cm quardrant along junction of roof with parapet wall finished smooth, where specially specified.HSR. 13.64
Precast chequered tiles of 20 mm thickness In ordinary grey cement without chips laid on 20 mm thick bed of cement coarse sand mortar 1:3 with neat cement slurry between joints and over the base in floors, treads of steps and landings.HSR-;14.45
Wire gauze fixed on chowkats with 25 mm thick cover moulding of full width of commercial hard wood such as hollock, champ chikrassy and chaplash, etc., (non-coniferous timber, other than team, conforming to I.S specification No. 1003, kiln seasoned) HSR. 17.33
P&F aluminium work for doors &windows , ventiletors & partions with extruded builtup standard tublar section /appropriate make conforming to IS, 733 and IS : 1285. Aluminium snap beading for glazing /panclling C.P. Brass /stainless steel screw , all complete . (HSR :-17.95)
P & F 12 mm thick prelaminated partical board flat pressed three layer or graded wood partical board . (HSR :-17.97 b)
P & F glazing in aluminium door windows , ventilators shutters &partitions etc(HSR :-17.98 b)
Factory manufacture solid flush door and Shutters, with block board core as per I.S. No. 1659-1969 bonded with water poof type phenol formal dehyde synthetic resin, hot-pressed, conforming to I.S. 2202 part I and II, fixed in positon includeing iron hinges, screws, chocks/cleats and stops etc. (excluding the cost of any fittings other than specified above, but including labour for fixing the same in position)-HSR-17.93 (35 MM THICK)
Cost of aluminium fitting complete for doors and windows, such as tower bolts, handles, etc., and screws for these fittings (excluding sliding bolt)- for double lead shutter (HSR-17.72 a)
Providing and fixing sliding bolt with nuts and screws etc. complete-aluminium-size 300 mm x 16 mm (HSR:-17.83 B)
Providing and fixing 150 mm floor brass door stoppers, with rubber cushion, screws, etc, to suit shutter thickness complete-HSR-17.75
Supplying and fixing hydraulic door Closer, I.S.I mark, with necessary Screws, etc., complete-HSR-17.82 C
Providing water proofing treatment on vertical surface in three layers chemical compound nafufill BB2 & Zentiritin (N.S. Items)
Providing & fixing water proofing treatment in bathroom leakage area by injection grouting with coating treatment including making holes in floor & walls of any size wherever dampness of honey combing is noticed, fixing of nozzles with cement mortar duly German Acrylic water proofing chemical MC special DM, filling of RCC gap with cement slurry shall be grouted with grout mix WH & German Acrylic based water proofing Chemical MC special DM with the help of 40 PSI grouting pump of ensure that all the voids, honeycombining are filled with the cement mix properly and cutting the surface nozzles and filling with cement & water proofing chamicaql paste including replacement of floor and wall tiles damaged during above repair, charging of water & electrical cost and guarantee period entire job. (N.S) (DSR-22.3 BASED ON 2012)
Providing & fixing false ceiling without GROOVES with 12mm to 15mm thick 600mm x600mm best quality mineral fiber tiles of approved. HSR. 13.92
Conglomerate floor 40 mm thick cement concrete topping 1:2:4 HSR-14.09
Cold twisted deformed (:ribbed/tor steel) bars for R.C.C. works, where not included in the complete rate of R.C.C including bending, binding and placing in positon complete.HSR-18.22
Cement concrete 1:1.5:3 with stone aggregate 20 mm nominal size for reinforced concrete work in slabs with inclination not exceeding 25 degree with horizontal, excluding steel reinforcement, but including centering and shuttering , laid in position, complete in all respects.HSR 10.82+10.95 a
Providing and fixing HDPE WATER STORAGE TANKS 1000 ltr. Capacity of Sintek, Diplast, O.K. Supreme make with covers/lids marked with IS:12701 on roof top of buildings including cost of hoisting and placing in position, making connections with inlet and outlet pipes, providing overflows and scour provision with suitable plug on scour pipe including cost of nipple washers, flanges for connections in tank complete in all respect to the satisfaction to the Engineer- in –Charge. (HSR. 30.119)
Providing and fixing in position 15 mm i/d C.P brass bib Cocks of best quality (as required by Engineer-in-charge)HSR-30.75 A
Providing and fixing in position C.P brass stop cocks (as Approved by the Engineer-in-charge) (HSR-30.76 Aii)
P&F G.I pipe complete with GI fittings DSR-18.12 15mm dia
20mm dia
PROVIDING AND FIXING IN POSITION BEST INDIAN MAKE FLEXIBLE TUBE CONNECTION.HSR-30.82B iii
PROVIDING AND FIXING IN POSITION INDIAN MAKE (ORDINARY) LAVATORY SUITES Consisting of SIZE 560X450mm HSR-30.41 V White
PROVIDING AND FIXING IN POSITION BEST INDIAN MAKE (to the approval of the Engineer-in-charge) INDIAN TYPE WATER CLOSET SUITE CONSISTING OF:-580MM White Colour HSR-30.1 A i)
PROVIDING AND FIXING IN POSITION BEST INDIAN MAKE (as approved by the Engineer-in-charge) EUROPEAN TYPE WATER CLOSET SUITE, SYPHONIC TYPE, Consisting of-HSR-30.5 A i)
PROVIDING AND FIXING IN POSITION BEST INDIAN MAKE SQUATTING URINALS OF SIZE 600 MM X 350 MM consisting of:-HSR-30.33 i)
p&f Rain water pipe 6kg pressure 100 mm dia complete in all respect as per HSR-13.89
providing & fixing Waster pipe for sink or washbasin including PVC fittings.DSR-17.28
P&F PVC low level flushing cistern with manually controlled device.DSR-17.18
P&F Waste/cutter jali complete in all respect N.S ITEM
( Electriccal Items ) Supply and erection of metal clad switches / B.D.Bs with rag bolts on wall or on existing angle iron board / pedestal including bonding to earth and necessary connections Triple pole switch with neutral link 32 amp. 415 Volts. HSR- 31.12(a) (xiv) Cat-B
Triple pole switch with neutral link 63 amp. 415 Volts. HSR-31.12 (a) (xv) Cat-B
Triple pole switch with neutral link 100 amp. 415 Volts. HSR-31.12 (a) (xvi) Cat-A
Triple pole switch with neutral link 200 amp. 415 Volts. HSR- 31.12(a) (xvii) Cat-A
Supply and erection of sheet steel enclosures distribution boards suitable for MCBs etc. on wall/ existing boards / pedestal with rag bolts including bonding to earth . TPN Distribution board 6-way. HSR-31.12(D ) (v)
Supply and erection of sheet steel enclosure 2 pole / 3 pole with earth plug and socket suitable for incorporating single pole / triple pole MCB on wall / on existing pedestal complete with necessary connections etc. S.P.N. enclosure for single pole MCB 20 amp. HSR- 31.15 (ii)
Supply and erection of miniature circuit breaker / isolator 240 /415 V in the existing distribution board including making necessary connections. SP MCB of 9 KA breaking capacity 6 amp. to 32 amp. HSR- 31.17a) (ii)
TPN MCB of 9 KA breaking capacity 6 amp. to 32 amp. HSR-31.17(a) (ii)
TPN MCB of 9 KA breaking capacity 40 amp. to 63 amp. HSR-31.17(a) (iii)
Switch 5 amp. On existing sheet. HSR-31.18 (xii)
Wall socket 5 amp. On existing sheet. HSR-31.18 (xiii)
Supply and erection of Fittings and Accessories. Bakelite angle / straight button holder large size. HSR- 31.18 (xi)
Ceiling rose flush / surface type . HSR-31.18 (xvii)
Bakelite sheet including fixing with brass screws and washers. 5 mm thick . 10000Sqmm (12no. Sheet of 10" X 13") HSR- 31.18 (xviii) (a)
Erection only of 1x40 watts or 2x40 watts 1220 mm long / 1x20 watts or 2x20 watts ,610 mm long fluorescent tube fitting directly on wall including necessary connections with 0.75 sqmm ( 24 / 0.20 mm ) PVC copper flexible cable for connecting the tube with the adjecent point. HSR-31.18 (xxiv)
Erection of ceiling fan complete with necessary earthing of fan and regulator including carriage from local railway station /goods transport /PWD store to the site of work. HSR-31.20 (i)
Erection of exhaust fan complete with necessary earthing of fan and regulator including carriage from local railway station /goods transport /PWD store to he site of work. HSR-31.20 (iii)
Erection of cabin fan complete with necessary earthing including carriage from local railway station /goods transport /PWD store to the site of work. HSR-31.20 (iv)
Supply and erection of pipe for wiring purposes including bends inspection boxes etc. where necessary and painting as required. Galvanised iron pipe 40 mm dia on surface. HSR-31.21 (v)
Galvanised iron pipe 50 mm dia on surface. HSR- 31.21 (vi)
Heavy guage welded conduit pipe 25 mm dia 1.60 mm thickness flushed. HSR- 31.21(xxii)
Supply and erection of PVC pipe of 6 kg. pressure laid 1 metre below ground level complete including digging refilling of the trench with jointing etc. PVC pipe 120 mm dia. HSR- 31.21(xxx) (a)
PVC pipe 80 mm dia. HSR- 31.21(xxx) (b)
PVC pipe 65 mm dia. HSR- 31.21(xxx) (c)
Earthing) Earthing with GI earth pipe 4.5 m long and 40 mm dia with masonry enclosure on the top etc. as required .HSR- 31.22(i)
Extra for using salt and charcoal / coke for pipe earth electrode as required. HSR- 31.22(ii)
Pdg. and fixing 4.00 mm dia G.I.wire on surface or in recess for loop earthing as required . HSR- 31.22(xvi)
Supply and erection of 20 mm x 3 mm thick G.I. tape fixed with suitable G.I. stapples of same size. HSR- 31.22(xix)
Supply and erection of under ground cable ,loose in existing pipe or trenches complete with necessary connections 6 Sq. mm 2 Core Cable . HSR- 31.26 (iii) Ard.
70 Sq. mm 3.5 Core Cable . HSR-31.26 (xxviii) Ard.
95 Sq. mm 3.5 Core Cable . HSR-31.26 (xxix) Ard.
120 Sq. mm 3.5 Core Cable . HSR-31.26 (xxx) Ard.
25 Sq. mm 4 Core Cable . HSR-31.26 (xIi) Ard
35 Sq. mm 4 Core Cable . HSR-31.26 (xIii) Ard.
50 Sq. mm 4 Core Cable . HSR-31.26 (xIiii) Ard.
Supply and erection of suitable compression type brass cable glands for underground Cable. Up to 6 sqmm Cable 2 to 4 core. HSR-31.28 (i)
25 Sqmm to 50 Sqmm Cable 2 to 4 Core. HSR-31.28 (iii)
70 Sqmm to 95 Sqmm Cable 3 to 3.5 Core . HSR- 31.28(iv)
120 Sqmm to 185 Sqmm Cable 3 to 3.5 Core HSR- 31.28 (v)
Erection of street light fitting on the pole including the cost of petty material required ( irrespective of height / length of bracket ). Pole above 7 metres but upto the height of 8 metres . HSR-31.30 (III) (xiv) (C)
Supply and erection of metal clad bus bar chamber made from 1.6 mm thick M.S.sheet fixed with rag bolts on wall or on existing pedestal / angle iron frame including bonding to earth , detatchable top and bottom painting and necessary connections etc.(Copper bars duly tinned ). 100 amp. 4 bars of 55 cm each (cross section 25 mm x 3 mm) chamber over all size 60 cm x 45 cm x 18 cm . HSR-31.31 (a) (ii)
200 amp. 4 bars of 55 cm each (cross section 25 mm x 5 mm) chamber over all size 60 cm x 45 cm x 18 cm . HSR-31.31 (a) (iv)
Supply and erection of aluminium lugs heavy duty including crimping etc. upto the entire satisfaction of the Engineer-in-charge of the work. 4 sqmm to 6 sqmm. HSR-31.35 (ix) (b)
25 sqmm . HSR-31.35 (ix) (e)
35 sqmm . HSR-31.35 (ix) (f)
50 sqmm . HSR-31.35 (ix) (g)
70 sqmm . HSR-31.35 (ix) (h)
95 sqmm . HSR-31.35 (ix) (I)
120 sqmm . HSR-31.35 (ix) (j)
3 pin15 amp. plug point with 4 sq mm PVC insulated Copper conductor cable- including earthing the 3rd. pin etc. Medium Point HSR-31.36 (VIII) b
Long point. 31.36 (VIII) c
Fan Point Short point HSR-31.38 (I) a
Medium Point HSR- 31.38 (I) b
Long point. 31.38 (I) c
Light Point Short point 31.38 (II) a
Medium Point 31.38 (II) b
Long point. 31.38 (II) c
Supply and erection of PVC unsheathed copper conductor cable single core 1100 volts grade in pipe of suitable size excluding cost and erection of pipe . Size 1.5 sqmm ( 3/0.81 ) HSR-31.40 (i)
Size 4 sqmm ( 7/0.85 ) HSR-31.40 (iii)
Supply and erection of Double door sheet steel enclosure distribution boards suitable for MCB's & ELCB's recessed in wall including bonding to earth complete with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4-way , TP&N ( Horizontal) (8+12) HSR-31.41 (v)
Supply and erection of PVC pipe ISI marked ( Medium ) recessed in wall / ceiling etc. including the cost of PVC bends , inspection boxes , iron hooks and cement concrete etc. complete in all respect upto the entire satisfaction of Engineer-in-charge of work. 20 mm dia. HSR-31.44 (i)
25 mm dia. 31.44 (ii)
Supply and erection of MS Saddle and clamps duly galvanised , on wall / RCC parapit for fixing underground cable at a distance of 0.60 metre center to center fixed by means of rawl plug including the cost of all labour and material required to complete the job in all respect and upto entire satisfaction of the Engineer-in-charge of work. HSR- 31.48
Supply and erection of weather proof MS box size 20cm x 30cm x 10cm of 16G and covered with MS sheet hinged cover having locking arrangement housed in 1:2:4 CC muff of size 40cm dia 55cm high including cost of PVC pipe of suitable size for incoming and outgoing cable, 4 copper bars of size 20mmx3mm, 125mm duly tined, insulated and supported with porcelain insulator, 2 No. 16A 416V kit-kat fixed in the MS box including painting etc. complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work HSR- 31.50
Supply and erection of 50mm diameter 1.5mtr. Long GI bracket (B-Class) making an angle 10 to 15 degree with horizontal plane for mounting street light fitting on GI bracket on wall with 2 Nos. 50mmx3mm thick MS flat including cost of cutting welding of GI pipe complete with cement sand mixture bolts and nuts etc. including making necessary connection with all labour and material required to complete the job in all respect up to the entire satisfaction of Engineer-in-charge of the work. HSR- 31.53
Supply & erection of Socket size rotary step type Electronic regulator for A.C ceiling fan Anchor make Delux model No. 50440 ISI / SSK make PC 561 operater on 120/280 V A.C Supply complete including cutting of existing Bakelite sheet and making necessary connection etc. up to the entire satisfaction of the Engineer -in- Charger of the work. HSR- 31.55
Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connection, complete in all respect. 10 amp. 1 way switch HSR-31.56 (i)
10 amp. 2 way switch HSR-31.56 (ii)
20 amp. Switch HSR-31.56 (iii)
10 amp. Socket HSR-31.56 (iv)
16 amp. Socket HSR-31.56 (v)
Fan Regulator HSR-31.56 (vii)
Blanking plate. HSR-31.56 (ix)
Providing and fixing GI concealed sheet metal boxes with inner and outer faceplate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respect. 4 Modules HSR- 31.57 (iii)
6 Modules HSR- 31.57 (iv)
8 Modules HSR- 31.57 (v)
12 Modules HSR- 31.57 (vi)
Supply of 48" (1200mm) ceiling fans complete with standard down rod, three blades fitted with double ball bearing with regulator Make ISI Orient, Bajaj , Crompton Complete in all respect. NS item
Supply of LED panel 2' X 2' sleek 40W Make ISI Philips , Bajaj , Crompton Complete in all respect. NS item
Supply of LED Tube Light fitting 18W Make ISI Philips , Bajaj , Crompton Complete in all respect. NS item
Supply of LED Street light 60W Make ISI Philips , Bajaj , Crompton Complete in all respect. NS item
Supply of Exhaust Fans 300mm single phase propeller type ventilating fan 6 poles Make ISI Khaitan, Bajaj , Crompton Complete in all respect. NS item
Supply of Louvers for 300mm. Exhaust Fans Make ISI Complete in all respect. NS item
Sh. Vipin Kumar Jain
M/s Parmesh Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .