Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹9.3 CrAdmitted-Finance | -11.88% | ₹9.3 Cr | L1 | Admitted-Finance |
| 2 | L2₹11.5 CrAdmitted-Finance | +9.83% | ₹11.5 Cr | L2 | Admitted-Finance |
| 3 | L3₹11.7 CrAdmitted-Finance | +10.90% | ₹11.7 Cr | L3 | Admitted-Finance |
| 4 | L4₹13.4 CrAdmitted-Finance | +27.91% | ₹13.4 Cr | L4 | Admitted-Finance |
Tender Value
₹10.5 Cr
EMD Value
₹21.0 L
Closing Date
17 Feb 2026, 6:00 pmClosed
Executive Engineer
KDA Kota
Civil Work
2026_UITKo_533581_1
NIT 33/2025-26 (36)
Open Tender
Civil Works
365 days
Kota
Please refer Tender documents.
2 documents required · 2 mandatory
₹7,500
7500 Secretary, KDA ,Kota 2500 MD RISL,Jaipur
₹21.0 L
Yes
17 Mar 2026
30 Jan 2026
18 Feb 2026
30 Jan 2026
17 Feb 2026
30 Jan 2026
Excavation for roadway in hard rock (blasting prohibited) with rock breakers including breaking rock, loading in tippers and disposal with a lift upto 1.5 m and lead upto 1000 metres, trimming bottom and side slopes in accordance with requirements of lines, grades and cross- sections as per MoRTH Specification Clause 301.3.5
Manual Means
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and MoRTH specifications Clause 1702, 1703, 2102 & 2104
P.C.C grade M 10
Nominal mix 1:3:6
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and MoRTH specifications Clause 1702, 1703, 2102 & 2104 R.C.C. grade M 25
Supplying, fitting and placing HYSD bar reinforcement in foundation complete as per drawings and MoRTH specifications Clauses 1009,1600 and 2102
Plain/reinforced cement concrete in substructure complete as per drawings and MoRTH specification Clauses 1700 and 2200
For height upto 5 m
R.C.C. grade M 25
Supplying, fitting and placing HYSD bar reinforcement (Fe 415) in substructrue complete as per drawings and MoRTH specification Clauses 1009,1600 & 2202
Providing and laying reinforced cement concrete in superstructure as per drawing and MoRTH specifications Clauses 1700, 2302 and 2304
Supplying, fitting, and placing HYSD bar reinforcement in superstructure complete as per drawing and MoRTH specifications Clauses 1009,1600 and 2302
Providing and laying Cement concrete for plain/reinforced concrete in open foundation as per drawing and technical specification as per MoRTH Specification : Section 1500, 1700 & 2100 including form work at any level. R.C.C. grade M25
Providing and laying steel reinforcement at any level in foundation/ pile/ pile cap complete as per drawing and clause 1600 of MoRT&H Specification including all material, labour and machinery.
The structural steel to be used should be Primary Steel manufactured and approved by Engineering in charged
TMT Steel reinforcement
Structural Cement concrete for plain concrete/ reinforced concrete for substructure at any level, complete as per drawing and technical specification. Using Batching Plant, Transit Mixture, and Concrete Pump. Design mix concrete - [MoRTH Specification : Clause 1500&1700] R.C.C including formwork R.C.C. grade M25 upto 5 metre height
Supplying, fitting and placing TMT bar reinforcement in sub structure/ superstructure at all level complete as per drawing and clause 1600 & 2200 of MoRT&H Specification including all material, labour, machinary etc.
The structural steel to be used should be Primary Steel manufactured and approved by Engineering in charged
TMT Steel reinforcement
Structural Cement concrete for reinforced concrete in superstructure at any level complete including steel formwork, scaffolding etc. as per drawing and technical specification as per Design mix MoRTH Specification 1500 & 1700.
M 25 grade T-beam and slab superstructure
Providing and laying Steel reinforcement at any level in foundation complete as per drawing and technical Specification as per MoRTH Specification : Section: 1600
The structural steel to be used should be Primary Steel manufactured and approved by Engineering in charged
TMT Steel reinforcement
Stone masonry work in cement mortar in foundation complete as per drawing and MoRTH specifications Clauses 1402, 1405, 2102 & 2104.
Random Rubble Masonry
In 1:3 cement mortar
Plastering with cement mortar (1:4), 20 mm thick on Stone work.
Backfilling behind abutment, wing wall and return wall complete as per drawings & MoRTH specification Clause 304.3.7 & 2204.6
Sandy material
Tubular Steel Railing on Medium Weight Steel Channel (ISMC series) 100 mm x 50 mm
Providing, fixing and erecting 50 mm dia steel pipe railing in 3 rows duly painted on medium weight steel channels (ISMC series) 100 mm x 50 mm, 1.2 m high above ground, 2 m centre-to-centre, complete as per approved drawings ad MoRTH Specification Clause 809
Providing and erecting a "W" metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ ground level, fixed on CRC rolled channel vertical post, 150 x 75 x 5 mm spaced 2 mm centre to centre, 1.8 m high, 1.1 m below ground / road level, all steel parts and fitments to be galvanized by hot dip process, all fittings to conform to IS: 1367 and IS: 1364 , metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per MoRTH specification Clause 811.3.
Excavation for roadway in hard rock (blasting prohibited) with rock breakers including breaking rock, loading in tippers and disposal with a lift upto 1.5 m and lead upto 1000 metres, trimming bottom and side slopes in accordance with requirements of lines, grades and cross- sections as per MoRTH Specification Clause 301.3.5
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and MoRTH specifications Clause 1702, 1703, 2102 & 2104
P.C.C grade M 10
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and MoRTH specifications Clause 1702, 1703, 2102 & 2104
R.C.C. grade M 25
Supplying, fitting and placing HYSD bar reinforcement in foundation complete as per drawings and MoRTH specifications Clauses 1009,1600 and 2102
Plain/reinforced cement concrete in substructure complete as per drawings and MoRTH specification Clauses 1700 and 2200
For height upto 5 m
R.C.C. grade M 25
Supplying, fitting and placing HYSD bar reinforcement (Fe 415) in substructrue complete as per drawings and MoRTH specification Clauses 1009,1600 & 2202
Providing and laying reinforced cement concrete in superstructure as per drawing and MoRTH specifications Clauses 1700, 2302 and 2304
R.C.C. Grade M 30
Supplying, fitting, and placing HYSD bar reinforcement in superstructure complete as per drawing and MoRTH specifications Clauses 1009,1600 and 2302
Reinforced Cement Concrete M 25 grade approach slab including reinforcement and formwork complete as per drawing and MoRTH specifications Clauses 1700 and 2704
Providing and laying cement concrete wearing course M 30 grade including reinforcement complete as per drawing and MoRTH specifications Clauses 1700 and 2702.2
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.49 MB
BOQ_950877.xls
BOQ • 0.34 MB
Bid_Document_33_36.pdf
Tender Documents • 31.56 MB
Corrigendum.pdf
Other Document • 0.19 MB
Download all tender documents and submit your bid