Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.9 LAccepted-AOC | L1 | Accepted-AOC L1 Accepted | |
| 2 | L2₹6.8 L+₹1.3 L (24.2%)Rejected-AOC | L2 | Rejected-AOC Other than L1 | |
| 3 | L3₹8.0 L+₹2.5 L (46.2%)Rejected-AOC VILL PO SERI TEHSIL NOWSHERA DISTT RAJOURI J K | NOWSHERA | RAJOURI | JAMMU AND KASHMIR | 185159 | L3 | Rejected-AOC Other than L1 | |
| 4 | L4₹8.5 L+₹3.0 L (55.7%)Rejected-AOC C O OPPOSITE MH MANDA POONCH ROAD AKHNOOR 181201 J K | JAMMU | JAMMU AND KASHMIR | 181201 | L4 | Rejected-AOC Other than L1 |
Tender Value
₹10.5 L
EMD Value
₹21,000
Closing Date
15 Mar 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (N) Akhnoor
Garrison Engineer (North) Akhnoor- 181201 C/o 56 APO
REPAIR MAINT OF SUMMER COOLING APPLIANCES AT SUNDERBANI UNDER GE (NORTH) AKHNOOR
2025_MES_698141_1
GE(N)/AKH-69/2024-25
Open Tender
Support/Maintenance Service
Item Rate
180 days
Sunderbani
Class E Cat b i
8 documents required · 8 mandatory
₹500
GE (N) Akhnoor
₹21,000
Yes
29 Mar 2025
15 Feb 2025
17 Mar 2025
15 Feb 2025
15 Mar 2025
1 Mar 2025
Amount
AIR CONDITIONER WINDOW TYPE M & L for removing the burnt/defective sealed compressor unit of any make from Window type of air conditioner capacity 1.5Ton by cutting of suction and discharge lines and un-screwing the foundation nuts, supply and fixing of new sealed compressor unit make - Tecumseh Kirloskar, Model RNB 5521 of rotary compressor by tightening the foundation nuts with new fittings and connecting suction and discharge lines with gas welding work complete all as directed.
M & L for removing the burnt/defective sealed compressor unit of any make from Window type of air conditioner capacity 2 Ton by cutting of suction and discharge lines and un-screwing the foundation nuts, supply and fixing of new sealed compressor unit make - Tecumseh Kirloskar, Model RNB 5529 of rotary compressor by tightening the foundation nuts with new fittings and connecting suction and discharge lines with gas welding work complete all as directed.
M & L for testing and repairing leakage in system Air conditioner of 1.5 ton capacity by injecting nitrogen gas upto 300 PSi, repairing leaking spots/joints with gas welding including supply & fixing of filter pencil type copper (in replacement), cleaning & flushing out complete system with gas, making the system leak proof, vaccumising the system and supply & charging refrigerant gas F-22 (approx 1.90 Kg) complete all as specified and directed.
M & L for testing and repairing leakage in system Air conditioner of 2 ton capacity by injecting nitrogen gas upto 300 PSi, repairing leaking spots/joints with gas welding including supply & fixing of filter pencil type copper (in replacement), cleaning & flushing out complete system with gas, making the system leak proof, vaccumising the system and supply & charging refrigerant gas F-22 (approx 2.30 Kg) complete all as specified and directed.
S&F in replacement of electric blower motor capacity 1/7 HP SP 230V, 50Hz, 930/875/825/775 RPM for window type Air conditioner including testing etc complete Make : Gulmarg/GE Motor/Crompton Greaves complete all as specified and directed.
S&F in replacement of electric blower motor capacity 1/5 HP SP 230V, 50Hz, 930 RPM for window type Air conditioner including testing etc complete Make : Gulmarg/GE Motor/Crompton Greaves complete all as specified and directed.
Supply & fixing in replacement thermostat for window type AC, working on SP, 230V,AC Make : Indfos/ Ranutrol, complete all as directed at site.
Supply & fixing in replacement of PCB circuit with remote control for air conditioner of any Make and capacity complete all as specified and direct ed at site. Make : Voltas/Carrier/Ranutrol/LG/Blue star
Supply & fixing in replacement air filter washable of Nilon mesh suitable for window type air conditioner complete all as specified and direct ed at site.
Supply & fixing in replacement starting capacitor 100 to 120 MFD, 440 volts AC ( Suitable for 1.5 TR window type AC) complete all as specified and direct ed at site. Make : Asian/Empire
Supply & fixing in replacement running capacitor 36/45 MFD, 440 volts AC ( Suitable for 1.5 TR window AC) complete all as specified and direct ed at site. Make : Asian /Empire
Supply & fixing in replacement capacitor 6 MFD, 440 volts AC ( Suitable for fan motor) complete all as specified and direct ed at site. Make : Asian /Empire
Supply & fixing in replacement relay box type model-KCH 5230004 Make : Usha/Arvind/Voltas
Supply and fixing of copper filter pencil type to any make and capacity of air conditioner complete Make : Vaishali Metal complete all as specified and directed.
S&F in repair front grill of PVC for window type AC of any make complete all as specified and direct ed at site. all as per existing grill
Supply and fixing in replacement relay over load protector complete set suitable for AC complete all as specified and direct ed at site.
Supply & fixing in replacement relay box type model-AC85004 /AC 85001 operating on SP 230 Volt, AC, Make : Usha/Arvind/Voltas
Supply & fixing in replacement cable PVC flexible copper conductor 3 core heavy duty 4.0 Sqmm complete all as specified and direct ed at site. Make : Plaza/Finolex/ ISI mark
Supply and charging of gas Freon - 22 in AC plant of any capacity Note:- Gas will be accepted in sealed and tested cylender having weight of gas 13.6 Kg in each cylender.
S&F in repairs Sheet metal enclosure with earth plug and socket single pole and neutral with single pole MCB 20 Amps 240 volts complete all as directed. Make:- HAVELL's or equivalent in Legrand/Standard.
S&F in repairs Metal clad plug, 2 pole with earth terminal capacity 20 Amp fixed in existing single pole and neutral enclosure complete.
S&F in repairs Metal clad socket, 2 pole with earth terminal capacity 20 Amp, fixed in existing single pole and neutral enclosure complete.
S&F in repairs MCB SP, 240 volts, 20 Amps, 10KA breaking capacity, 'C' type including connection with suitable size almuminium /copper lugs complete all as directed
M&L for plug top, 3 pin, 15 Amp, SP, 230V, fixed in repairs complete.
DESERT COOLERS Supply & fixing in replacement fan motor assembly of 1/7HP, 230V SP, AC complete clamps=04 Nos and water fan 18" sweep Make GE Motors/ Crompton/ISI Mark complete all as specified and directed.
Supply & fixing in replacement vertical pump/Water mersed pump complete tube operated on SP 230V AC Make : Crompton/cool- Home/GE Motors/ISI Marked complete all as specified and directed.
Supply & fixing in replacement wood-wool pad complete heavy size (set of three pads) Approx wt 400 Gms complete all as specified and directed.
Supply & fixing in replacement capacitor 6 MFD, 440V, Make - Empire/ EPCOS/ Capro/ Asian or ISI Mark complete all as specified and directed.
M&L for Scrapping down the complete existing paint inside and out side of desert cooler cleaning the surface and applying two coat of synthetic enamel paint over and including one coat of red oxide primer with sprayer and writing SM/MES No with white black enamel paint complete all as specified and directed.
WATER COOLERS Supply, fixing & testing of blower motor for water cooler SP 230V 50 Hz AC 1/12 HP 930 RPM with fan of size 12.5" dia complete etc Make : GE Motor/AUE complete all as specified and directed
Supply, fixing & testing of blower motor for water cooler SP 230V 50 Hz AC 1/20 HP 1350 RPM with fan of size 13" dia complete etc Make : GE Motor/AUE complete all as specified and directed
Supply, fixing & testing of blower motor for water cooler SP 230V 50 Hz AC 1/35 HP 1350 RPM with fan of size 10" dia complete etc Make : GE Motor/AUE complete all as specified and directed
Supply, fixing & testing of blower motor for water cooler SP 230V 50 Hz AC 1/83 HP 1350 RPM with fan of size 19" dia complete etc Make : GE Motor/AUE complete all as specified and directed
Supply & fixing in replacement starting capacitor 40 to 60 MFD, 275 volts for water cooler Make- Sharda/Empire/Bhel etc complete all as specified and directed.
Supply & fixing in replacement starting capacitor 60 to 80 MFD, 275 volts for water cooler Make- Sharda/Empire/Bhel etc complete all as specified and directed.
Supply & fixing in repairs running capacitor 10 MFD 440 volts AC for water cooler Make: EPCOS/ Capro /Asian etc complete all as specified and directed.
Supply & fixing in repairs running capacitor 15 MFD 440 volts AC for water cooler Make: EPCOS/ Capro /Asian etc complete all as specified and directed.
Supply & fixing in repairs running capacitor 25 MFD 440 volts AC for water cooler Make: EPCOS/ Capro /Asian etc complete all as specified and directed.
Supply & fixing in replacement thermostat for water cooler up to 150 ltr capacity. Make : Ranutrol/Danfoss/Indfos etc complete all as specified and directed.
Supply & fixing in replacement push cock heavy duty brass Chromium plated 15mm bore (to match with existing defective push cock) Make King or Equivalent ISI marked as approved by GE. complete all as specified and directed.
Supply and fixing in replacement of float valve 15mm bore of PVC rigid type with polythene ball complete all as directed Make : Prayag or Equivalent as approved by GE. complete all as specified and directed.
M&L for scrapping down the existing paint of water cooler of any make & capacity cleaning and preparing the surface with necessary putty work and painting the complete body of Water cooler with foundation frame of compressor, condenser etc with one coat of synthetic enamel paint over and including a coat of red oxide primer with spray painting and writing SM/MES No with white/black paint all as directed.
Supply and fixing starting Relay current type suitable for compressor model= AE 4440M, KCE 443 HAA, CAJ, 34, CAJ 2612M, AE451E, KCE 461 HAE , 513HAE complete, Make-Kirloskar/Tecumseh/ Usha / Arvind
Supply and fixing in repairs of over load protector for compressor of water cooler complete all as specified and directed.
Supply and fixing of copper filter pencil type to any make and capacity of water cooler etc complete Make : Vaishali Metal complete all as specified and directed.
Supply and fixing in replacement of capillary tubing having 0.050/0.055 bore complete Make : Vaishali Metal complete all as specified and directed.
Supply & fixing in replacement rubber hose pipe of 20mm size with clip for outlet tray of water cooler approx 1.5Mtr long complete all as specified and direct ed at site.
M&L for removing the burnt/defective sealed compressor unit of any make from water cooler cap 60 ltr/hr By cutting of suction and discharge lines and un-screwing the foundation nuts supply and fixing of new sealed compressor unit by tightening foundation nuts with new fittings and connecting suction and discharge line with gas welding work etc complete all as specified and directed.
M&L for removing the burnt/defective sealed compressor unit of any make from water cooler cap 80 ltr/hr By cutting of suction and discharge lines and un-screwing the foundation nuts supply and fixing of new sealed compressor unit by tightening foundation nuts with new fittings and connecting suction and discharge line with gas welding work etc complete all as specified and directed.
M&L for removing the burnt/defective sealed compressor unit of any make from water cooler cap 150 ltr/hr By cutting of suction and discharge lines and un-screwing the foundation nuts supply and fixing of new sealed compressor unit by tightening foundation nuts with new fittings and connecting suction and discharge line with gas welding work etc complete all as specified and directed.
Supply & fixing in replacement cable PVC 3 core flexible heavy duty copper 2.5 Sqmm complete Make : Plaza/Finolex or ISI Mark complete all as specified and directed.
M&L for Repairing Testing the leakage in system by charging of Nitrogen Gas up to 300 PSI. Repairing of leakage spots/Joints with gas welding work, cleaning and flushing the complete water cooler with gas, making the system leak proof, vacuuming the complete system, supply and charging of Freon-22 Gas approx 1.6 Kg complete for water cooler cooling capacity 40/60/120 ltr complete all as specified and directed.
M&L for dismantling of water cooler of any capacity and taking out complete internal assembly ie. Inner tank, inlet and out let connection etc and descaling with chemical agent including cleaning and washing and reassembling with same position and making the tank leak proof by necessary brazing/welding work with gasket etc complete all as specified and directed.
M&L Replacement of water cooler inner tank made of stainless steel as per existing capacity 80 Ltrs with necessary gaskets complete set with drilling work fixing with nut,bolts & washer etc complete all as specified and directed.
M&L for replacement of water cooler inner tank made of stainless steel as per existing capacity 150 Ltrs with necessary gaskets complete set with drilling work fixing with nut,bolts & washer etc complete all as specified and directed.
M&L for replacement of glass wool in 40/60/80/120 ltrs capacity water coolers by taking out inner outer tank and reassembling in same position including testing complete all as specified and direct ed at site.
M&L for repairing of bottom base and legs of water cooler by suitable welding work complete all as specified and directed.
DEEP FREEZER M&L Testing the leakage in system by charging Nitrogen Gas up to 300 PSI. Repairing the leakage spots/Joints with welding work including supply and replacement of filter pencil type copper and capillary tube of existing dia & length. Making the system leakproof vacuuming the system and charging of Gas 134a approx 1.0 Kg and testing complete
Supply & fixing in replacement of Relay current type and over load protector complete set suitable for compressor Model KCE 336 & KCE 345/2415 complete all as specified and direct ed at site.
Supply & fixing in replacement of thermostat Auto defrost type complete for Deep freezer of any make & capacity Make : Ranutrol/Indfos etc complete all as specified and directed.
M&L Removing burnt/defective sealed compressor unit from deep freezer of any make by cutting of suction and discharge lines and un-screwing of foundation nuts. Supply and replacing of new sealed compressor unit Make : Kirloskar Model :KCS 410 LAA/KCS 412 LAG/Tecumseh 2415 incl necessary gas welding making the system leak proof, testing and tightening the foundation nuts with new grounts and connecting suction and discharge line with gas welding work etc complete.
M&L Removing burnt/defective sealed compressor unit from deep freezer of any make by cutting of suction and discharge lines and un-screwing of foundation nuts. Supply and replacing of new sealed compressor unit Make : Kirloskar Make-Tecumseh Model TSK-1350 incl necessary gas welding making the system leak proof, testing and tightening the foundation nuts with new grounts and connecting suction and discharge line with gas welding work etc complete.
Supply and fixing relay current type and over load protector complete set suitable for compressor model No KCS 410 LAA or KCS 412 LAG fixed in repairs complete all as specified and directed.
Supply & fixing in replacement of driver filter complete set suitable for deep freezer 215 / 386 ltrs complete all as specified and direct ed at site.
Supply, fixing & testing of blower motor for Deep freezer SP 230V 20 watts complete with fan complete all as specified and directed
REFRIGERATOR S & F relay current type and overload protector complete suitable for compressor model KCE336, KCE345 fixed in repairs complete all as specified and direct ed at site.MAKE : Ranutrol/ Voltas /LG
S&F thermostat auto defrost type, fixed in repairs for refrigerators any make & capacity 165/310 Ltr Rerfrigerator complete all as specified and direct ed at site. MAKE : Danfos/Ind foss/Ranutrol
S & F vegitable tray as per sample and suitable for refrigerator Make Godrej, Voltas or whirlpool , LG of capacity 300 Ltr
S & F evaporator suitable for Voltas/Godrej refrigerators capacity fixed in repairs 286/300 ltr complete all as specified and direct ed at site .
M&L for removing burnt/defective sealed compressor unit of any make from any type/Capacity (165/286/300/310 Ltr) of refrigerator by cutting of suction and discharge lines and un-screwing of foundation nuts and supply & fixing new sealed compressor unit Make Tecumesh, Godrej, Voltas or whirlpool , LG, including necessary gas welding, making the system leak proof, including Repair to leakage in system by charging of nitrogen gas upto 300PSI, in the refrigeration system, testing and tracing the leakage in system, arresting the leakage with gas welding etc and making the complete system leak proof, vaccumising the system and testing, the system for smooth functioning complete and charging of refrigerent gas 134a complete all as specified and directed at site.
Supply and charging of gas Freon- 134-A complete all as specified and directed.
VOLTAGE STABLIZER Taking out of defective / burnt voltage stablizer from various locations of various capacity from 1 KVA to 5 KVA single phase and repair /replacement of the defective parts and testing as following complete all as specified and directed (i) Terminal Strip
Push button switch
Rocker switch
Circuit card from 3 to 5 KVA
Circuit card from 1 to 2 KVA
Relay 24 Volts 250 Ohms for 3 to 5 KVA
Indicator lamp (red/green)
narayan construction (BID ID -3263795)
M/s Mool Raj Ramesh Chander (BID ID -3263635)
Usha Engineering Co. (BID ID -3263738)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .