| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.9 LAccepted-AOC 181 2 KHURBURA MOHHALLA DEHRADUN UTTARAKHAND 248001 | DEHRADUN | UTTARAKHAND | 248001 | L1 | Accepted-AOC Accepted - AOC | |
| 2 | L2₹39.6 L+₹1.7 L (4.45%)Rejected-AOC | L2 | Rejected-AOC Rejected - AOC | |
| 3 | Rejected-Technical 5 DARSHANI GATE DEHRADUN PIN 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | - | Rejected-Technical Ban in WLR |
Tender Value
Refer Docs
EMD Value
₹88,000
Closing Date
16 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE DEHRADUN
GE DEHRADUN, MALL ROAD, GARHI CANTT, TELE - 01352750580
Repair and maint of cooling, heating appliances and allied works under AGE E/M-II of GE Dehradun
2020_MES_378554_1
8238/A/E8
Open Tender
Civil Works
Item Rate
240 days
GE DEHRADUN
Class D Cat b(i)
8 documents required · 8 mandatory
₹500
GE DEHRADUN
₹88,000
Yes
17 Dec 2020
17 Sept 2020
19 Oct 2020
17 Sept 2020
16 Oct 2020
2 Oct 2020
60 days
Amount
Servicing / Preventive maintenance of the following equipments of different capacities by checking of cooling coils, condensers, electric motors of different types and compressors and other parts, cleaning washing with suitable cleaning agent/chemical using vaccum cleaner, replacement of rubber wheels, bolts & nuts, screws check nuts, PVC sleeves and thimbles etc, checking all electrical parts and electrical wiring etc, tightening of electrical connections, greasing of electric motors to ensure serviceability all as specified and as directed.
(a) 1.5/2.0 Ton capacity window type Acs
(b) 1.5/2.0 tons capacity split type ACs
(c) Water coolers of any capacity
(d) Refrigerators capacity 165 to 310 Ltr
(e) Deep Freezers up to 310 Ltr
(f) Walk in cooler cold storage room
(g) Deep freezer vertical type 4 door
Supply & fixing in replacement unservicable starting relay box type (1022/1422/1622) suitable for 1.5/2TR capacity for window type/split type AC, Make:- Amcap/Epcos/Tibcon.
Supply & fixing in replacement unservicable starting capacitor of capacity (40-60/60-80/80-100/100-120) MFD, suitable for 1.5 /2 TR capacity window type/split type AC, Make:- Amcap/Epcos/Tibcon.
Supply & fixing in replacement unservicable 3 pin running capacitor of capacity (50+5)/(50+6)/(50+2) MFD suitable for 1.5/2 TR capacity window type AC, complete all as specified and directed. Make:- Amcap/Epcos/Tibcon.
Supply & fixing in replacement unservicable 220 V SP Auxillary Relay contactor for Split type AC 1.5 Ton/2 Ton of existing make & capacity, complete all as specified and directed. Make:- L&T/Simens /Indofoss /Danfoss /Crompton.
Supply & fixing in replacement of control contactor as per existing make & capacity complete all as specified and directed. Make:-L&T/Siemens/ABB/Indofoss/Danfos .
Supply & fixing in replacement of Plastic filter suitable for split type AC as per existing make & size complete all as specified and directed.
Supply & fixing in replacement of unservicable PVC insulated copper flexiable cable of size 2.5mm,three core multistranded suitable for window/Split AC 1.5/2 Ton capacity, complete all as specified & directed. Make:- Havells/Polycab/KEI
Supply & fixing in replacement thermostat switch suitable for 1.5/2 TR capacity window type/split type AC, complete all as specified and directed. Make:- Indofoss/Danfoss/Godrej/Simens.
Supply & fixing in replacement PVC front grill for window type AC's as per AC make upto 2 TR capacity complete all as specified and directed by Engineer-in-charge.
M&L for disconnecting the electrical and refrigerant connections of defective compressor unit of 1.5 Ton window type/ split type AC and replacing with new compressor connecting the sealed unit both electrical and refrigerant connections including charging refrigerant gas after nitrogen pressure test to find out leakage as required complete all as specified & directed. Make of Compressors : Kirloskar Complan/ Tecumesh/Carrier. Notes :- (a) New compressors shall be of same capacity make and type as of old compressors taken down / removed from the unit. (b) Compressors shall be purchased from OEM manufacturer/ authorised dealer of the manufacturer. (c) Compressors shall be in sealed condition. Supporting documents for replacement from manufacturer / dealer alongwith warranty certificate and paid vouchers shall be furnished by the contractor before installing the same and claiming payment . (d) Gas charging will be measured and paid only once for entire contract period while initial charging of compressor.
All as per ser item No. 12 here in before but for 2 / 2.5 TR AC complete all as specified & directed. Make of compressors:- Kirloskar complan/ Tecumesh/Carrier
Supply & fixing in replacement unservicable Fan motor suitable for 1.5/2TR window type AC as per existing make and testing at full load, complete all as specified and directed. Make:- AUE/GEC.
Supply & fixing in replacement of unservicable condenser fan blade for AC window type/Split type 1.5/2 Ton of any make & capacity, complete all as specified and directed.
Supply & fixing in replacement of unservicable Condenser fan motor for AC Split type outdoor unit 1.5/2 Ton of any capacity/size, complete all as specified and directed. Make:- AUE/GEC.
Supply & fixing in replacement of unservicable Blower fan motor for AC Split type indoor unit 1.5/2 Ton of capacity/size, complete all as specified and directed. Make:- Panasonic/GEC/Hitachi/Voltas/Bluestar .
Supply & fixing in replacement reverse cycle valve for heating system in window/split type AC 1.5/2 Ton capacity including charging of refrigerant gas R-22/R-134a and arresting all leakage and testing on full load, complete all as specified and directed.
Supply & fixing in replacement of Unserviceable split type Air conditioner indoor unit suitable for 1.5/2.0 Ton invertor type (Hot & Cold both mode) as per existing make & size complete all as specified & directed by Engr-in-charge.Make : Panasonic/GEC/Hitachi/Voltas/Bluestar/LG/Lloyd
Supply & fixing in replacement of unservicable Remote sensing unit suitable for 1.5 Ton split type AC fixed in PCB board as per existing make & size complete all as specified & directed.
Supply & fixing in replacement of unservicable Remote sensing unit suitable for 2 Ton split type AC fixed in PCB board as per existing make & size complete all as specified & directed.
Supply & fixing in replacement of unservicable Remote sensing unit suitable for 1.5 Ton window type AC fixed in PCB board replacement as per existing make & size complete all as specified & directed.
Supply & fixing in replacement Remote assembly cord / cordless as per existing make and size complete as specified.
Supply and fixing in replacement of unservicable damaged copper pipe with nitrile insulation of sizes 1/4” (6.35mm) for split/window AC, water cooler, complete all as specified & directed. Make:- Diamond/Star/Brassomatic.
All as per item No 24.00 here in above but of sizes 3/8” (9.52mm).
All as per item No 24.00 here in above but of sizes 5/8” (15.88mm).
All as per item No 24.00 here in above but of sizes 1/2” (12.7mm) .
Shifting of Split type Air Conditioner of any type and make, up to 2 TR from existing location to other location and installing indoor and outdoor units as directed including provision of necessary brackets (L type) clamps, GI nuts, bolts and washers etc for fixing of indoor / outdoor units including topping up of refrigerant gas and Nitrogen pressure test to find out leakage, commissioning and testing and making good disturbed surface complete all as specified & directed. Note : (i) PVC pipe for protection , drain pipe , control cable, extra copper tubing of any size for suction / discharge will be measured and paid separately.
Shifting of Window type Air Conditioner of any type and make, up to 2 TR from existing location to other location and installing as directed, commissioning and testing including making opening of required size in walls or existing windows of any type, provision of necessary brackets, clamps, GI nuts, bolts and washers etc for fixing of AC,and making good disturbed surface of walls and windows complete all as specified & directed. Note : (i) PVC drain pipe , control cable where required will be measured and paid separately.
M&L for disconnecting the electrical and refrigerant connections of defective compressor unit of 'Walk in Cold Room' of 2.5 TR and replacing with new compressor connecting the sealed unit both electrical and refrigerant connections including charging refrigerant gas after nitrogen pressure test to find out leakage as required complete all as specified & directed. Make of Compressors : Kirloskar Complan/ Tecumesh/Carrier. Notes :- (a) New compressors shall be of same capacity make and type as of old compressors taken down / removed from the unit. (b) Compressors shall be purchased from OEM manufacturer/ authorised dealer of the manufacturer. (c) Compressors shall be in sealed condition and shall bear warranty for 12 months from the date of installed. Supporting documents for replacement from manufacturer / dealer alongwith warranty certificate and paid vouchers shall be furnished by the contractor before installing the same and claiming payment . (d) Gas charging will be measured and paid only once for entire contract period while initial charging of compressor.
Disconnecting the electrical and refrigerant connections of walk in cooler cold room and supply and replacing expansion valve making both electrical and refrigerant connections including charging of refrigerant gas as required complete all as specified & directed.
Supply & fixing in replacement of filter drier for walk in cooler complete all as specified and directed by Engineer-in-charge.
M&L for disconnecting the electrical and refrigerant connections of defective compressor unit of storage type water cooler of capacity 40/80 Ltrs and replacing with new compressor, connecting the sealed unit both electrical and refrigerant connections including charging refrigerant gas/nitrogen pressure test to find out leakage as required, rectifying the leakage complete all as specified & directed. Make of Compressors : Kirloskar Complan/Tecumesh/Carrier. Notes :- (a) New compressors shall be of same capacity make and type as of old compressors taken down / removed from the unit. (b) Compressors shall be purchased from OEM manufacturer/ authorised dealer of the manufacturer. (c) Compressors shall be in sealed condition. Supporting documents for replacement from manufacturer / dealer alongwith warranty certificate and paid vouchers shall be furnished by the contractor before installing the same and claiming payment . (d) Gas charging will be measured and paid only once for entire contract period while initial charging of compressor.
All per Item No 33.00 here in above but water cooler of capacity more than 80 ltrs upto150 ltrs
Supply and fixing in replacement of unservicable starting capacitor 80 to 100 MFD for water cooler of any capacity, complete all as specified and directed. Make:- Amcap/Epcos/Tibcon.
All as per item No 35.00 here in above but of capacity 40 to 60 MFD.
Supply and fixing in replacement of unservicable running capacitor 2/3 pin 10 to 36 MFD suitable for water cooler compressors sealed unit of any capacity, complete all as specified and directed. Make:- Amcap/Epcos/Tibcon.
Supply and fixing in replacement of unservicable running capacitor 2 to 10 MFD suitable for blower motor of any capacity, 1/10, 1/12 HP complete all as specified and directed. Make:- Amcap/Epcos/Tibcon.
Supply and fixing in replacement of unservicable thermostat switch of water cooler of any size & make for compressors unit, complete all as specified and directed. Make:- Honey well/Simens/Danfoss.
Supply and fixing in replacement of unservicable over load Relay protector suitable for water cooler compressors unit of any capacity , complete all as specified and directed. Make:- L&T/Simens/Danfoss/ Godrej.
Supply and fixing in replacement of unservicable Package type relay complete for water cooler compressors unit of any capacity, complete all as specified and directed. Make:- L&T/Simens/Danfoss/Godrej.
Supply and fixing in replacement of condenser fan motor of water cooler for 40/80 ltrs or higher capacity duly connected and testing fixed in original positionincl taking down unservicable condensing fan motor complete all as specified and directed. Make:- AE/GEC.
All as per item No 42.00 here in above but 150 ltrs capacity, complete all as specified and directed.
Supply, fixing and testing in replacement of unservicable condensing fan motor blade for water cooler of any make & capacity, complete all as specified and directed.
Supply and fixing in replacement of brass float valve assembly 15mm dia with Nipple & Long screw with washers complete in water cooler, complete all as specified and directed. Make:- Polytuf/Prayag/Symet.
Supply and fixing in replacement of unservicable Push cock, brass chromium plated, self closing push button type, screwed for iron pipes ferrules of size 15 mm bore complete make as approved by GE and all as specified & directed. Make Jaquar/GEM/Prayag
Supply and fixing in replacement of unservicable PVC drain pipe 2m long of size 40mm dia complete alongwith hose clip of suitable sizes complete all as specified and directed. Make:- Polytuf/Prayag/Symet.
M&L for disconnecting the electrical and refrigerant connections of defective compressor unit of deep freezer of capacity upto 320 Ltrs and replacing with new compressor, connecting the sealed unit both electrical and refrigerant connections including charging refrigerant gas after nitrogen pressure test to find out leakage as required complete all as specified & directed. Make of Compressors : Kirloskar Complan/ Tecumesh/Carrier. Notes :- (a) New compressors shall be of same capacity make and type as of old compressors taken down / removed from the unit. (b) Compressors shall be purchased from OEM manufacturer/ authorised dealer of the manufacturer. (c) Compressors shall be in sealed condition. Supporting documents for replacement from manufacturer / dealer alongwith warranty certificate and paid vouchers shall be furnished by the contractor before installing the same and claiming payment . (d) Gas charging will be measured and paid only once for entire contract period while initial charging of compressor.
Supply and fixing in replacement unservicable condenser for 4 door deep freezer of capacity 2 TR as per existing make & capacity, complete all as specified and directed.
M&L for disconnecting the electrical and refrigerant connections of defective compressor unit of refrigerator of capacity upto 195 Ltrs and replacing with new compressor, connecting the sealed unit both electrical and refrigerant connections including charging refrigerant gas/nitrogen pressure test to find out leakage as required, rectifying the leakage complete all as specified & directed. Make of Compressors : Kirloskar Complan/ Tecumesh/Carrier. Notes :- (a) New compressors shall be of same capacity make and type as of old compressors taken down / removed from the unit. (b) Compressors shall be purchased from OEM manufacturer/ authorised dealer of the manufacturer. (c) Compressors shall be in sealed condition. Supporting documents for replacement from manufacturer / dealer alongwith warranty certificate and paid vouchers shall be furnished by the contractor before installing the same and claiming payment . (d) Gas charging will be measured and paid only once for entire contract period while initial charging of compressor.
All as per item No 50.00 here in above but for refrigerator of capacity 210 ltr to 320 Ltrs capacity.
Supply & fixing in replacement of unservicable condenser fan motor box type for Deep freezer of any capacity/size, complete all as specified and directed. Make:- Panasonic/GEC/Hitachi/Voltas/Bluestar .
Supply and fixing in replacement of unservicable thermostat switch suitable for refrigerator upto 320 Ltrs any make and capacity for refrigerator, complete all as specified and directed. Make:- Godrej/Indofoss /Danfoss/ LG/Samsung/Honey well.
Supply and fixing in replacement of unservicable starting relay box type suitable for refrigerator upto 320 ltrs of capacity complete all as specified and directed. Make:- Godrej/Indofoss/Danfoss/LG/Samsung.
Supply and fixing in replacement of unservicable bulb for refrigerator pin/screw type LED/GLS 5 watt, complete all as specified and directed. Make:- Phillips/Crompton/Havells.
Supply and fixing in replacement of ice tray, suitable for refrigerator of existing make, upto 320 litres capacity, complete all as specified & directed.
Supply and fixing in replacement vegetable tray, suitable for Refrigerator of existing make upto 320 litres capacity.
Supply and fixing in replacement of unservicable freezer chamber existing make & size for upto 165 to 195 Ltr capacity refrigerator direct cool complete all as specified & directed.
Supply and fixing in replacement of unservicable freezer chamber existing make & size for refrigerator frost free double door incl heater, blower etc for 285 to 310 litres capacity.
M&L in replacement of unservicable condenser for refrigerator as per existing make & any capacity, complete all as specified and directed.
M&L for charging of refrigerant gas R-134a with required pressure including nitrogen pressure test to find out leakage, arresting the leakage and testing on full load complete all as specified & directed. Note:- Gas charging for a particular machine will be measured and paid only once for entire contract period while first/ initial charging.
All as per item No 61.00 here in above but Refrigerant gas R-410a or equivalent
All as per item No 61.00 here in above but Refrigerant gas R-22 or equivalent
M&L for servicing of Air curtains unit upto 1.5m long each , AC, Single phase 230 volts as in preventive maintenance alongwith blower assembly and components to the entire satisfaction of engineer-in-charge complete all as specified & directed by Engineer-in-charge. Note : Replacement of blower, blower fan motor and rewinding of motor etc if required shall be measured and paid separately under relevant items of this schedule.
Taking down Aquaguard from its position, dismantling whole unit, servicing, cleaning and refixing in original position complete after replacing following parts and testing complete all as specified and directed. Note- Spare/ parts which are required to be replaced shall be measured and paid separetely under respective item of this sch under supply only.
Supply only in replacement of unservicable Pre- filter as per existing Make and size Aquaguard (candle) complete all as specified and directed.
Supply only in replacement of unservicable activated carbon blocks complete all as specified and directed.
Supply only in replacement of unservicable Solenoid valve 12 volts DC complete all as specified and directed.
Supply only in replacement of unservicable wiring circuit complete with suitable size of wire complete all as specified and directed.
Supply only in replacement of unservicable overflow sensor of suitable size , make and capacity complete all as specified and directed.
Supply only in replacement of unservicable PVC pipe as per existing Make and size complete all as specified and directed.
Supply only in replacement of unservicable PLV as per existing Make and size complete all as specified and directed.
S& F in replacement of unservicable overload relay with re-setting arrangments 9-15 Amp Cat No SS9414200BO of L&T or equivalent model as specified makes as approved by GE. Make:- L&T/Simens/ABB/Schneider
S & F in replacement of unservicable Bimetal overload relay 20-32 Amp as per existing size & make complete all as specified and directed. Cat No. SS9414500E0 of L&T or equivalent ABB/Tele mechnic/Simens.
S & F in replacement of unservicable power contactor with Aux contact AC 3 rating, complete all as specified and directed. Cat No. (MNX-9) of L&T or equvilant of Simens/ABB/Schneider
All as per item No 75.00 here in above but of size (MNX-18) of L&T or equvilant of Simens/ABB/Schneider
All as per item No 75.00 here in above but of size (MNX-25) of L&T or equvilant of Simens/ABB/Schneider
Servicing of geyser 25/50 ltr capacity in installed position (taking down from its original position on ground if required) opening up and taking out syphon assembly etc, removing deposited scales from syphon assembly, destoning complete inner tank, inspection against any leakages, serviceability of other parts and reassembling after replacement of unserviceable parts such as heating element, thermostat, indicating lamp, plug top, three core cable, rubber gasket, split plate, apparatus plate, NRV if required (Parts shall be measured and paid for separately under relevant item of the Sch) and installation of the geyser to its original position and connecting all electric and water supply connections complete all as directed by Engineer-in-Charge.
Supply and fixing in replacement water heating element any type (Triangle/cup/box) as per site requirement of capacity upto 2 KW ISI Marked. : Make:- Newton / Jaquar/ Bajaj.
Supply and fixing in replacement thermostat for geyser long type 11" in length as per site requirement temp setting on 60 degree centigrade ISI Marked, long type complete all as specified and directed. Make:- Newton / Jaquar/ Bajaj.
Supply and fixing in replacement thermostat for new version twin sensor short type with control box as per site requirement temp setting 0.75degree centigrade ISI Marked, complete all as specified and directed. Make:- Newton / Jaquar/ Bajaj.
Supply and fixing in replacement split plate for 25 ltrs capacity geyser as per site requirement and made out of 20 guage MS sheet duly painted complete all as specified and directed.
Supply and fixing in replacement geyser inner tank made out of stainless steel sheet conforming to relevant IS for 25 ltrs geyser as per existing model and make, complete all as specifeid and directed. Make:- Crompton/Racold/Venus/Havells/Jaquar
Supply and fixing in replacement syphon assembly with fusible plug, pressure release valve, vent pipe and rubber gasket etc for geyser any type of hole (6/7/9) all complete as per existing make & size as per site requirement all complete all as directed by Engr-in-Charge. Make:- Crompton/Bajaj/Racold/Jaquar.
Supply and fixing in replacement three core PVC insulated flexible and over all PVC round cable of size 40/0.0060 with multi stranded copper conductor complete all as specified and directed. Make : KEI/Poly cab/Havells.
Supply and fixing in replacement of water supply PVC flexible connection Nylon braided with suitable threaded check nut with washer complete suitable for hot and cold water 15mm dia alongwith threaded Brass nuts and washers 45 cm long complete all as specified and directed. Make:- Crompton/Havells/Prayag
Supply and fixing in replacement of unserviceable red/green indicating lamp for geysers
Supply and fixing in replacement solenoid valve 0.5" for dish washer complete all as specified and directed
Supply and fixing in replacement of stak pot burner 5" size, brass for LPG stove complete all as specified and directed by Engineer-in-charge.
Supply and fixing in replacement of Pilot burner brass for LPG stove complete all as specified and directed by Engineer-in-charge.
Supply and fixing in replacement of 5' HP T (Strip burner 5 feet) long complete all as specified and directed by Engineer-in-charge.
Supply and fixing in replacement of 2' HP T (Strip burner 2 feet) long for industrial type LPG stove complete all as specified and directed by Engineer-in-charge.
Supply and fixing in replacement of Copper connection pipe 6mm size 2 feet long for industrial type LPG stove complete all as specified and directed by Engineer-in-charge.
Supply and fixing in replacement of Copper connection pipe 6mm size 5 feet long for LPG stove complete all as specified and directed by Engineer-in-charge.
Supply and fixing in replacement of LPG flexible PVC pipe connection heavy duty 10mm dia, 6' long for LPG stove complete all as specified and directed by Engineer-in-charge.
Supply and fixing in replacement of LPG LPG flexible PVCpipe connection heavy duty 10mm dia 4' long for LPG stove complete all as specified and directed by Engineer-in-charge.
Supply and fixing in replacement of LPG HP Regulator heavy duty industrial type for LPG stove complete all as specified and directed by Engineer-in-charge.
Supply and fixing in replacement of Asbestos rope 20mm size for exhaust system complete all as specified and directed by Engineer-in-charge.
Supply and fixing in replacement of LPG Control valves brass for LPG pipe line complete all as specified and directed by Engineer-in-charge.
Supply and fixing in replacement of LPG Burner nozzel brass for industrial type LPG stove complete all as specified and directed by Engineer-in-charge.
Supply and fixing in replacement of LPG Sub zero control brass for LPG stove complete all as specified and directed by Engineer-in-charge.
Supply and fixing in replacement Hydro extractor spring for drier complete all as specified and directed by Engineer-in-charge.
Supply and fixing in replacement Hydro extractor main base rubber for drier complete all as specified and directed by Engineer-in-charge.
Supply and toping up for toping Gear oil for Atta kneading machine complete. Make : Castrol
Supply and fixing in replacement of bearing 6206 for gear box . Make - NBC/SKF.
Supply and fixing in replacement of Oil seal 60 x 40 x 10mm for Atta kneading machine complete.
Supply and fixing in replacement of Cast iron Pulley 4" Double groove for B Belts for Atta kneading machine complete.
Supply and fixing in replacement fan belt B-102 for Washing machine complete all as specified & directed. Make:- Fenner/Dunlop.
Supply and fixing in replacement unservicable heating element suitable for toaster, bakery oven, dish washing machine as per existing size/make and type complete all as specified & directed. Make: - Newton/Theta/Bajaj
(d) Heating rod 27" long U type 4 KW.
S&F in replacement of 3 phase 9 KW 14" long '' Instant type heating element for dish washing machine complete all as specified and directed. Make: Newton/Theta/ Bajaj
S&F in replacement of unservicable thermostat switch for Toaster, Oven, Dish washing machine 100 to 300 Degree centigrade as per existing size/make and type complete all as specified & directed. Make:- Godrej/Honeywell/ Danfoss.
M&L for repair & servicing to Gear box of dough Kneading machine by replacing required gear including overhauling/servicing/greasing and replacement of unservicable V belts 2 Nos complete all as specified & directed.
Repair/maintenance and servicing of Exhaust system by dismantling and taking out exhaust system impeller, bearings, shaft complete descaling the duct & servicing/ overhauling /cleaning/ heat varnishing of stator and rotar of the fan motor 3 phase 5 HP including replacement of ball bearing if necessary, greasing of ball bearing, shaft assembly, replacement of fan belts, duct canvas as per existing size & refixing the same after replacement of bush, nut, bolts,washers, rivets, blades, painting of rusted surfaces if any complete all as specified & directed by Engineer-in-Charge.
Repair/maintenance and servicing of Washing machine 50 Ltrs by dismantling of cup type bearing cover, greasing the bearings, greasing & oiling the shaft, removing old gland packing, cleaning and filling new gland, allainement of shaft as per existing, checking of fan tension & replace unserviceable belt, bearing if necessary, checking all electric cable connection complete all as specified & directed by Engineer-in-Charge.
Repair/maintenance and servicing of Dish washing machine by checking of all electric connection, rewiring where required complete with suitable size and heat proof insulated sleeves on cable, replacement of power contactor, relays, solenoide switches, heating element, cable connector blocks complete reassembling the same, testing for satisfactory result (Only power contactor, relays, heating element & solenoid switch will masured and paid separately all other items will be included in the quoted rate) complete all as specified & directed by Engineer-in-Charge.
S&F in replacement tamper proof electronic single phase whole currrent energy meter (LCD display) 10 Amp to 60 Amp, 240 volt class 1.00 and AC supply including cable connection, proper sealing with barcode with PVC seal. The meter shall comply with the latest version of IS-13779 with at least 2 anti tamper LED indications of line load reversal and earth loading indication including electrical connection with existing system and sealing properly including push fit type transparent meter box . The meter shall work satisfactory with guaranteed accuracy as per limit of IS: 13779. The meter shall be fixed on existing steel boxes on wall complete all as specified and directed. Make:- Secure saral/L&T/BHEL (Note:- Old unserviceable meter will be deposited to E/M store yard)
Repair/maintenance and servicing of potato peeler machine by dismantling and replacement of emery stone, v belt, greasing to pully, heat varnishing to motor stator, greasing the bearings, checking, greasing & oiling the shaft, refixing the same and made fully functional complete all as specified & directed by Engineer-in-Charge.
Notes for item Nos 1 to 119: (i) The works as described in BOQ against these items shall be executed based on the complaints intimated by Engi-in-Charge from time to time. (ii) Contractor's rep will visit the office of Engr-in- charge daily at 0930 Hrs to collect the complaints. (iii) After servicing and rectification contractor shall submit the complaint slip duly signed by the user to JE concerned other wise the the complaint shall not be treated as rectified and no payment shall be made for the work carried out against that complaint. (iv) The complaint shall be attended and rectified with in 24 hrs failing which a penalty @ Rs 500/- per day per equipment for non rectifying the defect will be charged to contractor and the amount will be deducted from the due payment of contractor.
(v) All units shall be repaired at their respective locations. (vi) Cost of all spares required to be replaced shall be measured and paid seperately under respective items of BOQ. (vii) Gas charging for each equipment shall be measured and paid only once during contract period irrespective of repitetive charging. (viii) Mode change from 'Cool' to 'Hot' or vice versa as per climatic will be made by contractor without any extra cost. (ix) Contractor shall provide his personal as well as official Mail ID, Land line & Mobile No. and local address to communicate the message for any break down. (x) Nut, bolts and hold fastners if required to be replaced shall be deemed to be included in the quoted rates for respective items.
Supply and install Refrigetor, electric driven (Single phase) of capacity 308 Ltrs or near higher size, double door, min 4 star frost free, double door convertible refrigerator complete all as specified and directed by Engineer-in-charge. Make- LG Model No-GL- T 322 RASN or equivalent in Samsung / Whirlpool.
Supply and install Refrigetor, electric driven (Single phase) of capacity 190 Ltrs or near higher size, single door, min 4 star invertor direct cool complete all as specified and directed by Engineer-in-charge. Make- LG Model No-GL- D201 ASCY or equivalent in Samsung / Whirlpool.
Supply , installation, commissioning of Energy efficient water cooler fully stainless steel, electric driven , single phase, having approx storage capacity 80 ltrs and nominal cooling capacity of 40 liters per Hour complete all as specified and directed by Engineer-in-charge. Make- Blue Star Model No- SDLX480 or equivalent in Voltas / Usha.
Supply , install,testing and commissioning of air cooled Split type all weather (Hot/cool) dual invertor Air Conditioners min 3 star rating of capacity 1.5/1.6 ton, electric driven (250 volts , 50 Hz,single phase supply), with energy efficient rotary compressor, working on R-134 (a) or superior envoironment friendly refrigerant, cordless remote operated, comprising of indoor unit, wall mounted, material of construction of indoor unit ABS, nomonal cooling capacity 4500 K Cal/ hour, power consumption(max) 2000 watts, min room discharge air flow 700 Cum /Hr guarenteed cooling capacity (min) 4275 Cal/ Hr, outdoor unit material of cabinet GI sheet 1.0 mm thick, powder coated, copper tubing condensor including bracket, copper tubing and connection cable complete(between indoor and out door unit max distance 10 mtrs) and condensed water drainage pipe complete all as specified. Make- Blue Star/ Daikin/samsung/LG.
Taking down carefully copper/Aluminum point wiring (light, fan socket and power) complete including switches, ceiling rose lamp holder and regulator etc and removing from site and making good disturbed surfaces of walls/floors etc complete all as specified and directed by Eng-in-charge.
M&L for Point wiring with1100 Volts, grade 1.5 Sqmm. (nominal area) ,PVC insulated but unsheathed multistranded copper conductor single core FRLS cable drawn through and including non metallic medium duty rigid PVC concealed conduit (medium duty) 20mm dia or higher size complete with all accessories such as socket, elbow, junction box, bell mouth, bend, reducer etc including pressed steel juction box of thickness1.2mm for mounting of switches, sockets, fan regulators etc with 3 mm thick plastic laminated sheet as top cover, and 1.5 Sqmm. (nominal area) single core FRLS,PVC insulated 1100 Volts, grade multi stranded unsheathed copper conductor cable green colour as earth wire upto common earth and connected to earth dolly including cutting chases for conduits and sinking's for boxes and making good to walls,floors etc complete all as specified and directed by Engr.-in-charge of following. Note : The wiring to be done as per IE rule and maintain colour code accordingly.
One light point / exhaust fan point/bell point ,SP, controlled by one, one way switch.
One ceiling fan point ,SP, controlled by one, one way switch.
One three pin 5 Amp socket on same board with other switches
One three pin 5 Amp socket on indepependent board
All as per Item No 125.00 mentioned here-in- before but one three pin 15 Amps switch socket out let on the independent board with 2.5 sq mm PVC insulated FRLS copper conductor and 2.5 Sqmm FRLS copper conductor for continuous earthing complete.
S & F Switch piano flush ,button type single pole one way 230 Volts 6 Amp complete all as directed. Make- Havells/HPL/Anchor Penta.
S & F Switch piano flush, button type single pole one way 230 Volts 16 Amp complete all as directed. Make- Havells/HPL/Anchor Penta.
S & F Socket outlet 2 in 1,5 pin , 230 Volts 5/6 Amps flush type multipurpose 5 pin complete. Make- Havells/HPL/Anchor Penta.
S & F Socket outlet ,2 in 1,5 pin , 230 Volts 5 Amp & 15/16 Amps flush type multipurpose complete. Make- Havells/HPL/Anchor Penta.
S & F bell push flush type 5 Amps 230 Volts single pole complete. Make- Havells/HPL/Anchor penta.
S&F Bell Ding dong 250V AC complete all as specified & directed. Make : Havells/L&T Raaga/Anchor
Supply and fixing Ceiling rose, Three terminal of size 65x25 mm,ISI marked surface bakelite suitable for batten fitting complete all as specified . Make- Havells/HPL/Anchor .
S & F step type electronic fan regulator,120 watts, 5 step for ceiling fan 1200/1400 mm size 230 volts AC Complete. Make- Havells/HPL/Anchor
S & F Lamp holder polycarbonate insulated body, with back plate with and incl LED lamp retrofit 9/10 watts complete. Make- Havells/HPL/Anchor
S&F in replacement wall mounted tube light fitting 1x20/22 watts extruded aluminium polycarbonate covers PF 0.9 and above operating voltage 140V-270V colour temp 4000K & lumen input output 95 Lumen per watt and connected to ceiling rose with required length of two core flexible copper cable 23/0.0076 fixed on wall/roof complete all as specified and directed. Make:Wipro Cat part No LL20-281-XXX-65AL1/ Philips cat part No BN021C LED20S PSU CWGR S2/Havells Cat No ENDURA LINEARNEOBS20W LED865SPCWH.
S&F in replacement of Decorative wall light fixture made up of Polycarbonate, suitable for 15 Watts LED Lamp incl one LED New Odore 10W E27 WW Ball Lamp Lumen output 835 (lm) 3000K complete all as specified and directed by Engineer-in-charge Make : Havells (City-1) cat part No LHDL02160099 (Fitting) LHLDERHEMD8X010(Lamp) or eqvt in Wipro / Philips / Mepro.
S&F in replacement of energy saving Bulk head luminaire with opal diffuser with and including retrofit LED lamp 10 watts complete all as specified and directed by Engr-in-charge. Make : CG cat LBHP-10-CDL/Philips WT140W LED7S CW PSU S1 PC/Havells ENDURA RUGBYNEO N /Bajaj cat no BIBWP10WLED.
S&F in replacement mirror light decorative compact luminarious with decorative ends caps 9 Watt or higher LED with all accessories and including connecting up with three core flexible copper conductor cable of suitable size . Make - Philips Cat No BN 021 LED 10 S+6500 PSU GR S1 or eqvt in Havells/Wipro.
S&F in replacement surface mounted LED 600x600 mm light fitting made of CRCA powder coated finish with high tranisitivity diffuser,LED used shall be profoled LED & flat diffuser type and cap 32 wattage or higher ,CCTupto 6500 K, CRI>80,PF>0.95 or higher side including driver min internal surge protection 2.5KV complete all as specified and directed by Engineer-in-charge Make : Havells PLUTONE02x2PLR34WLED857S/Philips SM365C LED32- 6500 PSU Od WH / Wipro CRCO10R038HP57GL.
Taking down existing unsv security light fitting and Supply, fixing , connecting and testing of 35 watt LED building security light luminaries with min 10 KV surge protector die cast alluminium housing LDR sensor for automatic operation complete suitable for and incl bracket 32 mm GI pipe bend to shape incl clamp fastner, bolts, nuts & washers of min 1.2 Mtr incl grouting etc and 3 core 1 sqmm PVC insulated cable from ceiling rose to light fitting complete all as specified Make:- Green Star Cat No-DSS40/CG LSTP-45-CDL/ Havells ENDURAPEARLINEOSL40WLED757PASYTOPC/ equivalent in Philips
Supply, fixing and Testing in repairs TPN DB VTPN 4 way 415 Volts, 50 Hz indoor type double door Sheet metal enclosure IP-43 DB's flush mounted with 250 Amp Copper busbar for each phase with two neutral bar & two earthbar and cable ties for cable managenment including mounting arrangement for DPX3 MCCB 125 Amps four pole 415 volts as incomer including connection terminal strip complete pre wired with suitable size copper conductor. The DB's should hold type test certificate (CPRI) as per IEC 61439-3 complete all as specified and directed by Engr-in-charge incl taking out Unserviceable DBs, MCCB and MCBs of any capacity, Make: Legrand Cat No-5077 45or equivalent in L&T/Schneider.
S&F sheet metal enclosures 240 volt with suitable rated bus bar for double door 12 way IP-43 DB's mounting flush on wall/concealed and making good distubed surfaces incl taking out Unserviceable DB any capacity. complete all as specified and directed by Engr-in-charge. Make: Legrand Cat No-5076 12 or equivalent/ L&T/ Indo Asian.
S&F sheet metal enclosures 240 volt with suitable rated bus bar for double door 8 way IP-43 DB's mounting flush on wall/concealed and making good distubed surfaces incl taking out Unserviceable DB any capacity. complete all as specified and directed by Engr-in-charge. Make: Legrand Cat No-5076 11 or equivalent in L&T/Schneider.
Supply and fixing in repairs wall mounted type sheet metal single pole and neutral enclosure with a two pin and earth plug and socket complete with and including MCB SPN 20 Amp 'C' series 10 KA mounted on DIN rail channel and suitable plug complete all as specified and directed by Engr-in-charge. Make: Legrand Cat No 5078 14 or eqvt in L&T / Schneider.
Supply and fixing in repairs wall mounted type sheet metal triple pole, neutral and earth plug enclosure with a four pin and earth plug and socket complete with and including MCB TPN 32 Amp 'C' series 10 KA mounted on DIN rail channel and suitable plug complete all as specified and directed by Engr-in-charge. Make: Legrand Cat No 5078 61 or eqvt in L&T / Schneider.
S&F in replacement of MCCB 125 Amps four pole 415 volts thermal magnetic release ICU=100% ICS having breaking capacity 16 KA including connection terminal strip complete all as specified & directed Make:Legrand cat No-4200 16 or equivalent in L&T/schneider.
S&F MCB SPN 240 Volt 10 KA 40 Amp 'C' series conforming to IS complete all as specified & directed. Make: Legrand Cat No-4086 18 or equivalent in L&T/Schneider.
S&F MCB single pole 240 volt, 10 KA, 40 Amp, 'C' series confirming to IS complete all as specified and directed. Make: Legrand Cat No-4085 96 or equivalent in L&T/Schneider.
M&L for sub main wiring with 2 Single core PVC insulated unsheathed cable 1100 Volts grade heavy duty copper conductor multistranded of size 4 Sqmm (nominal area) drawing in and including 20 mm dia or higher medium duty PVC concealed conduit and conduit accessories and fittings. Including one single core green colour PVC Insulated unsheathed cable copper conductor multistranded of size 4 Sq mm as earth wire upto common earth and connected to earth dolly complete incl taking out old unserviceable submain all as specified & directed. (Note: 3 Run of 4 Sqmm cable and one run of conduit shall be measured as one unit)
M&L for sub main wiring with 2 Single core PVC insulated unsheathed cable 1100 Volts grade heavy duty copper conductor multistranded of size 4 Sqmm (nominal area) drawing through existing steel/PVC conduit etc Including one single core green colour PVC Insulated unsheathed cable copper conductor multistranded of size 4 Sq mm as earth wire upto common earth and connected to earth dolly complete incl taking out old unserviceable submain all as specified & directed. (Note: 3 Run of 4 Sqmm cable shall be measured as one unit)
S & F in repair of u/s OT light bulb 50 Watt 12 V as per existing make & watt suitable for existing OT lights complete all as specified and as directed. Make-Philips.
Supply and fixing of maintenance free lead acid sealed battery 12 Volts 7 Ah complete
Supply and fixing of maintenance free lead acid sealed battery 26 Volts 7 Ah complete
Supply only moveable LED OT light of lux output 160000, deep cavity illumination, aerodynamic shape, light colour adjustment, adjustable light intensity mounted on spring balance arm with touch panel SMPS control box suitable for input voltage 100-240 Volts AC supply consisting of 12 Volt maintenance free battery of min 03 Hrs backup with visual indication of charging ON and battery low with all the standard fittings on and incl heavy base stand complete all as specified at site Engr in charge. Make: Meditech Model No XN4 or equalent in Philips/Luvis/Striker
M&L required for refilling of 25 KG ABC type fire extinguisher of 70-90% MAP complete incl decaning of existing material and refilling with fresh powder with cartridge etc complete incl disposal of existing retrieved material as per CPCB norms complete.
All as per item No 156.00 here in above but 10 KG
All as per item No 156.00 here in above but 5 KG
All as per item No 156.00 here in above but 2 KG
All as per item No 156.00 here in above but 9 KG foam type 3/6
All as per item No 156.00 here in above but 3 KG CO2 type
All as per item No 156.00 here in above but 4.5 KG CO2 type
All as per item No 156.00 here in above but 9 KG CO2 type
M&L comprehensive maintenance and repair of addressable fire alarm system installed at (Make:- Morley IAS 5 e) by service Engineer of Honeywell or its auth channel partner i.e. Godrej security/G4S Security/Honeywell complete including servicing of all fire sensors MCP's, repeater panel, hooters etc, checking of Electric control panel, etc. The work also includes cleaning/replacement of heat or smoke detectors, MCP's, loop cards of panel batteries etc testing on completion upto satisfaction of Engineer-in-Charge.
Notes for item No- 164 :- (i) Spares other than mentioned in this item shall be measured and paid separately as supply only under relevant items of Sch 'A' but the cost of fixing is included in this item. (ii) The tenderer shall submit a copy of MOU with OEM or its authorized service channel partner for AMC to fire alarm system for service of system as and when required. (iii) The quoted rate include material and labour required for cleaning of detectors twice in contract period complete all as specified and directed. (iv) The rates deemed to include for minor items such as lugs, thimbles, fuse etc. (v) The contractor shall keep all spares reqd for routine maintenance and attend the defects immediately. In case of major defects it shall be attended within 3 days failing which penal recovery @ 5000/- per day will be charged the decision of GE will be final & binding.
Supply, only addressable manual call point with working voltage 24 volts DC + 2 volts , push button with one pair of open one pair of closed contacts protection grade IP-44 , operating temperature 0 degree c to painted with red shade complete in all respects. Make-Apollo, System Sensor, Edward, Phillips.
Supply only addressable heat/smoke detectors with operating voltage range of 24 VDC + 2 Volts , protecting grade - IP 32 operating temperature 68 degree C , humidity range < 95% RH itself extinguishing Polycarbonate housing / Flame retardant thermoplastic white color, 1 LEDs for indications complete with base of detector etc. as required UL, MF UPCB approved. Make-Apollo, System Sensor, Edward, Phillips.
Supply only remote response indicators made from 1.6 mm thick CRCA sheet having dual Red LED indications & provision for cable/wire entry from top Make-SAFEZONE, MINIMAX ELECTROQUIP, MATHER & PLATT, VIJAY
Supply only electronic loop card suitable for Morley IAS 5 e make addressable fire alarm panel complete
Supply only fault isolators suitable for fire alarm addressable fire alarm control panel complete.
M&L for servicing to existing solar water heater 300 LPD vacuum tube type incl dismantling of all inlet outlet water connection electric connection incl cleaning descaling hot water storage tank and glass tube, cold water tank complete carefully without damaging any parts of the solar water heater and replacement of unserviceable parts complete, reassembling of complete solar water heater and checking for any leakage to the system incl reconnection of all water supply and electric complete all as specified and directed by Engr in charge. Note:- (i) Item rate incl all minor spare such as Teflon tape or any other pipe fitting wire etc required for making solar water heater functional. Other items such as glass tube, heating element, cable, tank etc shall be measured and paid separately.
S&F rotational moulded polyethylene water storage tanks (Cylindrical, vertical with closed top) double layer confirming to IS:12701-96 complete including provision of all inlet outlet overflow and drain pipe fitting complete, all as specified and directed by Engineer in Charge capacity 300 Ltrs. Make – Patton/ Sintex/ Rounaq Aqua ISI .
Supply only quartz glass tubes suitable for Electrotherm make 300 Ltrs evacuated type solar water heater complete.
Pantech Instruments and Services
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .