Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹51.6 LAccepted-AOC GCC2 9CP ADARSHA NAGAR KOLKATA WEST BENGAL 700107 | KOLKATA | KOLKATA | WEST BENGAL | 700107 | L1 | Accepted-AOC L1 | |
| 2 | L2₹64.7 L+₹13.0 L (25.2%)Rejected-Finance VILL P O P S SAGARDIGHI BLOCK SAGARDIGHI PIN 742226 | SAGARDIGHI | MURSHIDABAD | WEST BENGAL | 742226 | L2 | Rejected-Finance L2 | |
| 3 | L3₹70.6 L+₹19.0 L (36.7%)Rejected-Finance 21 4 21 3 CENTRAL PARK JADAVPUR KOLKATA 700 032 | KOLKATA | KOLKATA | WEST BENGAL | 700032 | L3 | Rejected-Finance L3 | |
| 4 | Rejected-Technical AB 179 SECTOR 1 SALT LAKE LAKE TOWN NORTH 24 PARGANAS WEST BENGAL 700064 | 24 PARAGANAS NORTH | WEST BENGAL | 700064 | - | Rejected-Technical Disqualified |
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
7 Aug 2021, 12:00 pmClosed
MD,WBMSCL
GN-29 Sector-V, Salt Lake, Kolkata, West Bengal 700091
DSIC and Operation and Maintenance of MGPS at Isolation ward/ Covid unit of Sagar RH of West Bengal for 5 years
2021_WBMSC_338174_1
WBMSCL/NIT-270/2021, Dated28/07/2021
Open Tender
MECHANICAL
Item Rate
20 days
Sagar RH at Rudranagar in S 24 Pgs District
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
₹20,000
29 Dec 2021
30 Jul 2021
7 Aug 2021
30 Jul 2021
7 Aug 2021
30 Jul 2021
Amount
OXYGEN SYSTEM
2 x 10 size main manifold complete with middle frame with chain for individual cylinder along with Tail Pipe and Non Return Valve for every cylinder and Isolation Valve, Safety Valve, etc. as required for the complete manifold system
8 cylinder Emergency manifolds complete with middle frame with chain for individual cylinder along with Non Return Valves and tail pipes for every cylinder and with ESAB IOX 14 high flow Oxygen Regulator having non-halogenated polymer at the higher pressure side. In case of reduction of pressure of the main manifold, there should be automatic changeover from main manifold to emergency manifold.
Fully automatic control panel for Oxygen with automatic changeover facilities from running bank to reserve bank of cylinders and vice- versa. Non Return Valve, Isolation Valve, Safety Relief Valve, etc. as required for the complete system
Surface/panel/pendant mounted front loading double lock Oxygen outlets with matching Adapters (BS type) as per standards
Oxygen Flowmeter & Humidifier Bottle with matching Adapter: Back Pressure Compensated Flow meter within a range of 0-15 LPM where 0-5 LPM should be with expanded scale. Humidifier bottle should be made of unbreakable polycarbonate materials and autoclavable at 121 degree Centigrade (to be supplied along with required low pressure tubing and face mask)
Distribution of Copper Pipe
12 mm OD x 0.7 mm thick copper pipe
15 mm OD x 0.9 mm thick copper pipe
22 mm OD x 0.9 mm thick copper pipe
28 mm OD x 0.9 mm thick copper pipe
Isolation Valve
Isolation Valve 15 mm
Isolation Valve 22 mm
Isolation Valve 28 mm
Area Valve Service Unit
1 gas valve box configuration with size 15 O2
Medical Gas Digital Area Alarm System as per standards
1 service alarm configuration for O2
Turnkey - for both Civil & Electrical work wherever necessary
Operation & Comprehensive Maintenance charges
Operation & Comprehensive Maintenance charges for the 1st Year
Operation & Comprehensive Maintenance charges for the 2nd Year
Operation & Comprehensive Maintenance charges for the 3rd Year
Operation & Comprehensive Maintenance charges for the 4th Year
Operation & Comprehensive Maintenance charges for the 5th Year
SAGARDIGHI CONSTRUCTION AND CO
B.S.MEDICAL INTERNATIONAL
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .