Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 4 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 5 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
Refer Docs
Closing Date
15 Jun 2021, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer RNB Electric Division Srinagar
Barbarshah Maisuma Srinagar
Internal Electrification with controlling and protection switch gear devices with fixtures etc for Science Block of Womens Degree College Baramulla
2021_PWDJK_126146_1
E/NIT/32/2021/22dtd04/06/2021
Open Tender
Electrical Works
Item Rate
30 days
Internal Electrification with controlling and prot
as per BOQ
7 documents required · 7 mandatory
₹1,100
Executive Engineer RNB Electric Division Srinagar
Exempted
15 Jun 2021
4 Jun 2021
15 Jun 2021
5 Jun 2021
15 Jun 2021
5 Jun 2021
120 days
Amount
Supply and Fixing of medium grade PVC conduit incl. its allied accessories like bends, j boxes etc. for laying of wires recessed in slab / walls incl. refacing of walls or fitted with necessary cliffs and rowel plugs complete( Approved before installation )
a) 25 mm dia.
b) 40 mm dia.
Point wiring for switch controlled primary light points with 3x1.5 sq. mm (P+N+E) FRLS PVC insulated 660/1100 volt grade flexible stranded copper conductor wires of Finolex /Anchor /Havell’s /Polycab make in recessed or surface Conduit and incl. the cost of supplying and fixing modular grid plate mounted flush mounted 240 volts 6 amp control switch of Legrand make and colour housed in zinc chromate passivity GI boxes with modular cover plate complete as per specification and as required of reputed make ( Excl. cost Of Conduit) ( Approved before installation )
Point wiring for Computer point with 3x2.5 sq. mm (P+N+E) FRLS PVC insulated 660/1100 volt grade flexible stranded copper conductor wires in recessed or surface conduct incl. the cost of supplying and fixing modular grid plate mounted flush mounted 3 no 240 volts 6 amp 3 pin socket out let along with 2 no. 6 Amp control Switch of Legrand make and colour housed in zinc chromate passivity GI boxes with modular cover plate and inter connections and including cost of loop Earthing with 2.5 sq. mm FRLS PVC Insulated 660/1100 circuit wiring( from DB to first switch in the sub circuit) complete as per specification and as required volt grade flexible stranded copper conductor wires complete as per specifications and as required ( Excl. cost of Conduit) ( Approved before installation )
Point wiring for 16 Amp Socket out lets with 3x4 sq. mm (P+N+E) FRLS PVC insulated 660/1100 volt grade flexible stranded copper conductor wires in recessed or surface conduit and incl. the cost of supplying and fixing modular grid plate mounted flush mounted 240 volts 16 amp 6 pin combined shuttered socket out let along with 240 volt 16 Amp control Switch of approved quality and colour housed in zinc chromate passivity GI boxes with inter connection complete as per specifications and as required. ( Excl. cost of Conduit) ( Approved before installation )
Supply and Fixing of Fan dimmer Modular grid plate flush mounted 240V 5 Step Electronic Speed Regulator of Legrand / Havell’s Make to be housed in zinc Chromate passivity G I Boxes with moulded Cover Plate of same make With Necessary Connections Complete Job. ( Approved before installation )
Supply of Integral LED 4 ft luminaire with CRCA housing and PC Glossy cover. The luminaire should have a colour consistency SDCM < 5, CRI > 80 and CCT of 6500K. The luminaire shall be compliant with IP20 classification. Luminaire shall be designed to emit at least 4000 nominal lumens at a system efficacy of at least 115 lumen/watt with maximum system wattage of 34 Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 50k burning hours @ design ambient temp 45 deg. C. The electronic driver used shall have a power factor >0.95 and THD <10% and suitable for an operating voltage range of 140-270V AC. Manufacturer shall have Noinhouse lab approved by NABL or ministry of science of govt. of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters.
Supply of LED indoor surface down lighter suitable for general lighting. Luminaire should have polycarbonate cover with diffused optics. The luminaire should have CRI > 80 and CCT of 6500K. The luminaire shall be compliant with IP20 classification. The fixture should have a minimum system efficacy of 110 lumen/Watt and a minimum system lumen output of 1600 lumens and maximum system wattage of 15 Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 50k burning hours @ design ambient temp 45 deg. C. The electronic driver used shall have a power factor >0.95, THD <10%. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt. of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters.
Supply of LED indoor surface down lighter suitable for general lighting. Luminaire should have polycarbonate cover with diffused optics. The luminaire should have CRI > 80 and CCT of 6500K. The luminaire shall be compliant with IP20 classification. The fixture should have a minimum system efficacy of 110 lumen/Watt and a minimum system lumen output of 2000 lumens and maximum system wattage of 18 Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 50k burning hours @ design ambient temp 45 deg. C. The electronic driver used shall have a power factor >0.95, THD <10%. Manufacturer shall have in house lab approved by NABL or ministry of science of govt. of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters.
Supply, Installation testing and commissioning of Ceiling Fans of Crompton Greaves / Havel's / Usha make (Sample to be got approved) with ceiling rose of SSK make Complete incl. making of necessary connections
1200 mm sweep
1400 mm sweep
Supply, Installation testing and commissioning of 250 mm sweep Shutter type Exhaust Fans of Usha / Crompton Greaves / Havel's with way ceiling rose of SSK make incl. making of necessary connections and making of necessary space in walls / Windows as per site( Approved before installation )
Supply, Installation, Testing and Commissioning of AC/DC Bells of standard make with its batteries. ( Approved before installation )
Supply and fixing modular blanking plates on existing modular switch plates, excluding cost of plates. ( Approved before installation )
wiring for Circuit/sub-main wiring along with earth wire in FRLS PVC insulated 660/1100 volt grade flexible stranded copper conductor wires of standard make (to be got approved before installation) in recessed or surface conducting system excluding cost of conduit of following sizes( Approved before installation )
4 x 4 SQ. mm + 1 x 4 SQ. MM Earth Wire. For lighting Sub main
2 x 6SQ. mm + 1 x 6 SQ. MM Earth Wire for A C points.
4 x 6SQ. mm + 1 x 6 SQ. MM Earth Wire for Computer points.
4 x 10 SQ. mm + 1 x 10 SQ. MM Earth Wire for Heating Sub main wiring.
4 x 16 SQ. mm + 1 x 16 SQ. MM Earth Wire for AC Sub main wiring
Supplying and fixing of following way prewired TP&N MCB distribution Boards of sheet steel of Legrand / Hager / Siemens / L&T make for 415 volts on surface / recess complete with loose wire box, terminal connectors for all incoming and outgoing circuits, dully wired with suitable size, FRLS PVC Insulated copper conductor up to terminal block, tinned copper Bus bar, neutral link, earth bar , din bar, detachable=cable gland plate, interconnections, powder coated painted including Earthing etc. as required, ( but without MCB/RCCB/Isolator) ( Approved before installation )
8 Way (8+24) Ip43 with metal door.
12 Way (12+36) Ip43 with metal door.
Supplying and fixing following rating, four pole, (three phase and neutral), 415 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. ( Approved before installation )
32 Amperes
40 – 63 Amperes
Supplying and fixing of 32 Amp rating TPN 240/415 volts "C" curve MCB`s of Legrand / Hager / Siemens / L&T/ABB make suitable for inductive load of following poles in the existing MCB DB complete with connections testing and commissioning etc. as required( Approved before installation )
Supplying and fixing of 40 - 63 Amp rating TPN 240/415 volts "C" curve MCB`s of Legrand / Hager / Siemens / L&T/ABB make suitable for inductive load of following poles in the existing MCB DB complete with connections testing and commissioning etc. as required. ( Approved before installation )
Supplying and fixing of 32 Amp rating DP 240/415 volts "C" curve MCB of Legrand / Hager / Siemens / L&T / ABB make suitable for inductive load of following poles in the existing MCB DB complete with connections testing and commissioning etc. as required. ( Approved before installation )
Supplying and fixing of 40 - 63 Amp rating DP "C" curve MCB`s of Legrand / Hager / Siemens / L&T/ABB make suitable for inductive load of following poles in the existing MCB DB complete with connections testing and commissioning etc. as required. ( Approved before installation )
Supplying and fixing of 6 Amps to 32 Amp S Pole rating 240/415 volts "C" curve MCB of Legrand / Hager / Siemens / L&T / ABB make suitable for inductive load of following poles in the existing MCB DB complete with connections testing and commissioning etc. as required. ( Approved before installation )
Supply & fixing of 32 Amps Industrial type metal clad socket outlet with inter connections in heavy gauge powder coated G.I box with inter connections and proved and fitted with 40 Amps D P MCB and 220 Volt, 25 Amp 3 plug top complete job of Anchor /SSK/Legrand/Havell’s/ABB / L&T make for A.C points. ( Approved before installation )
Supply and laying of B-Class 100 mm dia. size M S pipe under Road/Floor not less than 1 Mtr below ground level including excavation and refilling. ( Approved before installation )
Supply/ installation/testing and commissioning of floor mounted compartmentalized , 415 volts TPN MCCB Floor distribution panels of sheet steel of 16 gauge dust protected, painted incl. earth terminal with all necessary accessories as required for panel and of adequate size to accommodate all following accessories complete Incoming (1) 250 Amp TPN MCCB of Legrand / Siemens/ Hager/L&T /ABB make with breaking capacity of 35 KA = 1 no 200 Amp TPN Bus bar Al Strips = 1 Set Outgoing 63 Amp TPN MCCB of Legrand / Siemens/ Hager/L&T make = 4 nofor Output 40 Amp TPN MCCB of Legrand / Siemens/ Hager/L&T make = 2 no 32 Amp TPN MCCB of Legrand / Siemens/ Hager/L&T make = 2 no Volt meter = 1 no Ammeter = 1 no CT coils for Ammeter 300 / 5A = 1 set Indicators = 1 sets (3 No's) ( Approved before installation )
Providing of Maintenance Free Earthing System using copper bounded earthing steel rods 2 inches in dia. and 2 Mtr. long placed vertically in a bore well of 4 Inch in dia. dully bored manually with 250 micron copper molecular bonding along with 2 bags ( 11.5 Kg each) of Ground Enhancement Material (GEM) or Equivalent with each rod to reduce the soil resistivity to a considerable value.
Providing and laying of 25x3 mm size Copper Strip in one run for extension of earthing to equipment/controlling.
Supply and laying of 1 No DWC high density poly ethylene pipe having corrugation on outer wall and plain surface inner wall confirming to IS: 14930 complete with accessories for protection of 1.1 Kv grade underground cable excluding cost of cable to be laid underground 50 cm deep including excavation and refilling of same. 160/136 mm.
Supply, laying, Connecting and Commissioning of 185 sq. mm 3.5 core XLPE/PVC insulated and steel armoured 1.1 KV grade Al Cable of Hovels / KEI / Paragon make laid as per site condition( Approved before installation )
Supply, Installation, Testing and Commissioning of 630 Amps By Pass Four Pole Change over switch of Havell’s/Legrand Make, Incl. its sheet steel enclosure with angle iron stand and handle with making of necessary connections complete job. ( Approved before installation )
Providing of ISI marked Dry type Co2 Type fire Extinguisher of 4.5 kg capacity fitted with High Pressure Hose, Squeeze Grip type Control Valve with self-indicating Pressure Gauge . ) ( Approved before install
Supplying & laying of wiring for fire alarm system wiring using ISI marked (IS 694) 1100 Volts grade, PVC insulated, flexible, flame retardant (FR)2 x 1 sq. mm copper conductor, including connections to the detectors, manual call points , hooters, fault isolators, accessories, fire alarm control panel etc. including termination with bottle type copper lugs as required to complete the system. (Anchor/Havell’s/Finolex/Polycab) ( Approved before installation )
Supply, Installation, testing and commissioning of Intelligent Analog Addressable Type High Sensitivity Laser Based Smoke detector having 9 sensitivity levels (from 0.07- 6.56%/m) Complete with Dual LED, Hard Addressable Having rotary decade Address switches from 01-99, complete with Mounting Base Complete as required Conforming to BS 5839 Standards and Duly approved by EN54/LPCB/VDS/UL/BSA including of mounting Base as required. (System Sensor/Safeway/Cooper/Morley/Ases) ( Approved before installation )
Supply, Installation, testing and Commissioning of Intelligent Analog Addressable Type Rate of Rise/Fixed Heat Detector Complete with Dual LED, Hard Addressable Having rotary decade Address switches from 01-99, complete with Mounting Base Complete as required Conforming to BS 5839 Standards and Duly Approved by EN54LPCB/VDS/UL/BSA (System Sensor/Safeway/Cooper/Morley/Ases) ( Approved before installation )
Supply, Installation, testing and commissioning of Intelligent Analog Addressable Type Manual Call Point having Surface or flush mounting Option fully complaint to EN54 having Rotary Decade Switches’ for Addressing from 01-99 complete with Back Box for Mounting Complete as required conforming to BS5839 Standards and Duly Approved by EN54/LPCB/VDS/UL/BSA (System Sensor/Safeway/Cooper/Morley/Ases) ( Approved before installation )
Supply, Installation, testing and commissioning of Strobe type electronic hooters conforming to BS5839 Standards and Duly Approved by EN54/LPCB/VDS/UL/ with mounting base, housed in sheet steel / Polymer housing suitable for wall / ceiling and surface / recess mounting including making connections with wires complete in all respects and as per specifications. (System Sensor/Safeway/Morley/Cooper/Ases) ( Approved before installation )
Supply, Installation, testing and commissioning of Intelligent Analog Addressable Type Monitor Modules having option of RAIL or Surface Mounting with Tri Colour LED status Indicator with Built in Short Circuit Isolators having Visible Rotary Decade Address Switches from 01-99 dully approved to GEA GE1-082 conforming to BS5839 Standards and Duly Approved by EN54/LPCB/VDS/UL/BSA (System Sensor/Safeway/Morley/Cooper/Ases) ( Approved before installation )
Supply, installation, testing and commissioning of Intelligent Analog Addressable Type Control/Output Modules having option of RAIL or Surface Mounting with Tri Colour LED status Indicator with Built in Short Circuit Isolators having Visible Rotary Decade Address Switches from 01-99, for initiating Hooter/Sounder/Strobes etc. dully approved to GEA GE1-082conforming to BS5839 Standards and Duly Approved by EN54/LPCB/VDS/UL/BSA (System Sensor/Safeway/Morley/Cooper/Ases) ( Approved before installation )
Supply, Installation, testing and commissioning of Addressable type Fault Isolator for isolating shorted, de-linked and loose circuits between two successive fault isolators with automatic resetting arrangement to be interconnecting to loop cable complete as required conforming to BS5839 Standards and Duly Approved by EN54/LPCB/VDS/UL/BSA (System Sensor/Safeway/Morley/Cooper/ASES) ( Approved before installation )
Supply, installation, testing & commissioning of 4 Loop Microprocessor based 2 wire fault tolerant loop, required loop networkable type (each loop accessing 99 detectors and 99 modules ) fire alarm/detection control panel. The panel shall be able to give location of all fire/fault conditions of addressable units via the address codes. Further, the panel must be able to automatically switch ON /OFF respective control module whenever any alarm is triggered. The panel shall have rectifier, Loop cards, 80 character L C D unit to indicate Fire/Fault Signal with address and analog output, external/inbuilt printer to log all fire or fault events complete in all respects.The Panel Shallbe Sheet Steel Painted, sealed to IP30. The Panel Shall have 20 Zones with Individual LED Indicators, expandable to 80 LED Indicators. The Panel Shall have 3 Serial Ports. The panel shall have a built in power supply and battery charger along with maintenance free 24 AH, 2 x 12 volt SMF Lead acid batteries capable of running for a minimum of 24 hours with battery charger complete as required and as per specifications. conforming to BS5839 Standards and Duly Approved by EN54/LPCB/VDS/UL/BSA (System Sensor/Safeway/Morley/Cooper/Ases) ( Approved before installation )
Supply, Installation and Commissioning of 15 KVA, 3Phase, 415V LT unbalanced AVR of ALBA/Electric Control/Electric Field/Power Engineer/Muslim Engineer make. The servo voltage stabilizer shall operate from input voltage (L-N) =90-270V (L-L 155- 470V) thereby producing the corresponding output voltage of 415V ±5% (Phase to Phase) the servo stabilizer should further have inbuilt protections of over voltage, under voltage and overloading with TDR. The stabilizer shall be servo controlled automatic, ONAN cooled and provided with first filling of fresh filtered transformer oil having required di electric strength, the stabilizer shall further be capable of smooth operation upto 10% unbalanced in the load currents. The supplier has to give guarantee for any manufacturing defect with three servicing of equipment for 1 year reckoned after commissioning. ( Approved before installation )
Providing and fixing of lightning conductor finial, made of 25 mm dia. 300 mm long, G.I. tube, having single prong at top, with 85 mm dia. 6 mm thick G.I. base plate including holes etc. complete as required.
Providing and Fixing of G I Strip 25mm x 3mm strip.
Supply and fixing of fan junction boxes.
M/S MIR ENGINEERS
M/s JK SECURITY SOLUTIONS
M/s NEW LIGHT ENTERPRISES
M/S MOHD ASHRAF MIR
bhat and brothers co
M/S AFAQ AND CO
stage.html
html • 0.03 MB
finance_247851.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .