Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.9 LAccepted-AOC KUCHHADI VADI VISTAR PORBANDAR GUJARAT 360579 | PORBANDAR | GUJARAT | 360579 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹35.3 L+₹2.7 L (8.27%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹36.4 L+₹3.8 L (11.6%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹37.2 L+₹4.6 L (14.1%)Rejected-Finance JAVERI BUNGALOW AREA KAVERI HOTEL LINE NH PORBANDAR 360 575 | PORBANDAR | GUJARAT | 360575 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹37.7 L+₹5.1 L (15.7%)Rejected-Finance 121 MADHAV SQUAR OPP AVANTIKA COMPLEX LIMDA LANE JAMNAGAR 361001 | JAMNAGAR | GUJARAT | 361001 | L5 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹64,000
Closing Date
25 Jan 2023, 6:00 pmClosed
Maj Yogender Singh
GE Navy Porbandar Tija Mile Porbandar
CERTAIN REPAIRS TO JOINERY, FLOORING, SANITARY FITTINGS, SUNKAN FLOOR, WALL, ROOF TREATEMENT AND MISC B/R WORKS AT INS SARDAR PATEL, NAE, MES COMPLEX, NAUSENA BAGH AND NOFRA AND TAXI TRACK LIGHT, HIGH MAST LIGHT AND HANGER LIGHT AT NAE PORBANDAR
2023_MES_573079_1
9137/PBR/E8
Open Tender
Civil Works
Item Rate
180 days
Porbandar
Please refer Tender Documents
7 documents required · 7 mandatory
₹500
Yes
Garrison Engineer Navy
₹64,000
Yes
1 Feb 2023
4 Jan 2023
27 Jan 2023
5 Jan 2023
25 Jan 2023
19 Jan 2023
5 Jan 2023 - 18 Jan 2023
Amount
Taking down chowkats or frames exc 1.5 sqm and n.exc 4 Sqm each with shutter (without taking off Shutters from the frame) and desposing off complete all as specified.
Plain solid, straight chowkats and frames of second class hard wood Wrought Framed rabatted on the solid rounded or chamfered, put together with glue pinned at joints Complete all as specified and directed.
Factory made 35mm thick, flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides of covered with decorative face veneer and lipping / with teak wood beading 6mm thick complete all as specified and as directed.
Factory made 35 mm thick, 2nd class hard wood (Hollock), glazed and skeleton shutters open rebated and prepared to receive glass/ gauge etc (without sash bars), edges of framing plain chamfered or rounded, fitted with cut and mitered beads for securing glass etc for doors, size of members as specified in clause 8.24 (a) of MES Schedule Part-I Section-8, complete all as specified.
12mm thick toughened glass for door, partition etc. of any size and side portions of toughened glass fixed to wall / floor, joints sealed with clear silicon silicate gel to make water tight, edges with diamond cut including taper drilling to flush the screws / all fitting as required, floor hinges, patch fitting top, bottom and sides, lock and handles, spider joint etc. and concealed floor door spring as per requirement all as specified, required at site by manufacturer instructions and complete all as specified and directed.
Taking down shutters of any descriptions, area exceeding 1.00 Sqm but not exceeding 2.00 Sqm complete all as specified and directed by Engineer-In-Charge.
Fiber Glass Reinforced plastic (FRP) Door Frames of cross section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminte shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame complete as specified by the manufacturer and as per directions of Engineer-in-charge.
30mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames, complete as specified by the manufacturer and as per directions of Engineer- in-charge.
300mm long (Length of Bolt in mm) Aluminium alloy, anodised,sliding door bolt with hasp,staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed in repairs complete all as specified.
200mm long (Length of Bolt in mm) Aluminium anodised,barrel tower bolts of extruded section and fixed in repairs complete all as specified and directed.
150mm (Size of Handle in mm) Extruded aluminium alloy handles, fabricated type, anodised and fixed in repairs complete all as specified.
100mm Butt hinges (Size of hinges in mm), medium weight, cold rolled, stainless steel, and fixed in repairs complete all as specified.
140mm long Floor door stopper of aluminium alloy body & tongue, anodised, with hard drawn steel spring and fixed in repairs complete all as specified.
Taking down Shutters of any description exc 2 sq. m each and removing to store complete all as specified.
Powder coated Anodised aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading, screws fixed in repairs complete all as specified.
Plain colour PVC sheet 2mm thick fixed or laid on aluminium doors by using rubber based adhesive complete all specified and directed by Engineer-in-Charge.
Powder coated Anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc complete all as specified.
Aluminium anodized Deco grills 6.50 mm of Design No DG 104 with suitable size F & H sections as required to aluminium/wooden windows fixed in repairs / replacement complete all as specified and directed.
Aluminium Alloy wire cloth. 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples fixed in repairs / replacement complete all as specified.
Preparation of new wooden surfaces of any description over 10 cm width or girth not otherwise described and applying two coats of synthetic enamel paint complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise described for of any description complete all as specified.
Mild steel work in Gates , Grating drilled and countersunk for balusters running bars, for doors, balusters, wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed by Engineer in Charge.
Rolled mild steel Framed work (rolled mild steel Fe - 410-W (Gde-E-250) quality "A") as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging also fastening and fixing complete all as specified and as directed.
Preparation of old steel surfaces of any description over 10 cm width or girth not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed.
Hacking out old broken glass (any thickness, size, quality or description) from wooden/aluminum frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and directed.
4.8 mm thick Sheet glass,ordinary quality pin headed type and glazing with Aluminium snap beading with rubber Neoprene packing in square exc 0.5 sq. m in each pane complete all as specified and as directed.
Solar control film 25 micron reflective type sticked to glass panes as per instructions of manufacturers exc 1.5 sqm complete all as specified and as directed.
Taking down aluminium decogrills and refixing in the same opening including cutting of decogrills if required complete all as directed.
Repair to steel gate of garrage of size exc 3sqm to 5 Sqm by taking down of required and necessary welding work including welding of Hinges, Cleats, MS Plate, MS Sheets etc and refixing to same or other opening as directed complete all as specified and as directed by Engineer-In-Charge. Note: Welding work will be done at site by arrangement of welding set without any extra cost to the Government. The cost of Hinges, MS Plate / angle, MS Sheet etc will be paid seperately under relevent item.
Taking down carefully steel shutters of any description exc 1 sqm and n exc 2 sqm each including replacement of rusted and broken hinges and incl all fittings including necessary welding work and fixing in same opening after making good complete all as specified and directed by Engineer in Charge.
Dismantling of floor hearth and wall tiling including mortar beding removing tiles and rubbish off the premises complete as directed by the Engr-in-Charge.
Non skid Ceramic coloured Joint free tiles of size 300x300x7-8mm thick (area of each tile exceeding 0.6 Sqm but n.exc. 0.11 Sqm) as in floor set and jointed in neat cement slurry and pointed in white cement with pigment to match the colour of tiles over and including 15mm thick bedding layering cement mortar (1:6) complete as specified and directed.
Glazed ceramic tiles, coloured (light colour as approved) of size 300x600x7to8mm / 350x250x7to8mm / 450x300x7to8mm / 300x200x7to8mm thick on vertical surfaces such as in skirting/dado etc set and jointed in cement slurry over 15mm thick rendering in cement mortar (1:4) and pointed in white cement with pigment to match the colour of tiles complete as specified and directed.
Vitrified Ceramic tiles 9-10 mm thick, Light shade coloured (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, as in floors set and jointed in neat cement slurry and pointed in white or coloured cement to match, over and including screed bed or bedding layer 20mm thick in cement mortar 1:6 complete all as specified and as directed.
Vitrified Ceramic tiles 9-10 mm thick (square / rectangular) area of each tiles not exceeding 0.36 sqm, as in skirting set and jointed in neat cement slurry and pointed in white or coloured cement to match, over and including rendering 10 mm thick in cement mortar 1:4 complete all as specified and as directed.
Taking down shaft RCC jali and refixing the same position with CM 1:4 including necessary scafolding and painting complete all as specified and directed.
35 mm thick Providing precast cement concrete louvres and jallies,(measured solid), (1:2:4 type B0 using 12.5mm graded stone aggregate) set and jointed in cm 1:4 including necessary scafolding and painting complete all as specified and as directeded. Note : this item is measured in respect of high rise building/shaft/duct area and pipe line repair work.all mouldings but excluding frame (Pre cast frame shall be measured separately and paid for under item
Demolition of brickwork or stone/boulders/block masonry, built in cement mortar including all quoins, arches, pillars, ashlar facing, dressed stonework, precast concrete artilcles and precast concrete block walling etc complete all as specified and directed.
Stone masonry walling or squred walling in cm 1:6, brought upto courses using dressed same size Porbandar stone of superior quality complete all as specified and directed.
Stone masonry walling or squred walling in cm 1:6, brought upto courses but except stone complete all as specified and directed (Serviceable stones retrieved from item No. 40 will be reused).
20 to 25 mm thick Kota stone slab of 40mm width for strip at doors cills in single pieces fixing with polymer modified tile adhesive of approved make complete all as specified and directed.
Repair to door, window, ventilator by spot welding in repairs exceeding 2.50 cm but not exceeding 5.0 cm in length thickness of metal to be welded not exceeding 6.0mm thick, complete all as specified and as directed by Engr in charge. Note : Welding work wil be carried at site by arrangement of welding machine without any extra cost to the Govt.
Dismantling wall and ceiling boards (fiber, pulp, insulation) or insulation boards / slabs / blankets, any thickness including cover fillet complete all as specified and directed.
Hollow PVC wall lining/pannelling consisting of 5mm thick of single side prelam PVC sheet instead of plain colour sheet inclusive of solvent cement, beading etc and fixing on PVC frame as in repair as specified in MES schedule Part I and II complete all as specified and directed.
18-19mm thick pre-laminated particle board (incl dismantling), flat pressed single layer type or three layer type with BWR type adhesive, medium density interior grade having one side decorative lamination and other side balancing white lamination as in cup board shutter , shelves etc including 6 mm thick teak wood leaping on three sides and 20mm thich on hanging side & French polishing to edging complete all as specified.
Continuous (piano) hinges mild steel bright finish or electro galvanised 30 mm width of flaps complete all as specified and directed.
Repair and refixing of aluminium window shutter to make it openable/slide smoothly, including cutting, repair/change of all necessary fittings/fixtures for window like cleates , locking arrangements glazing cleats and cadmium plated stainless steel screws including rubber gaskets beadings etc complete all as specified and as directed by Engr in charge
Sink with drain board made of stainless steel 1 mm thick kitchen with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 1040mm x 510mm bowl size 460mm x 410mm x 200mm glossy finish, including waste pipe, brass coupling fixed in repair / replacement complete all as specified.
40mm dia cupboard knobs fixed with nut, screw and washer of mild steel bright finished fixed in repair / replacement complete all as specified.
Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples fixed in repair / replacement complete all as specified.
Safety chain in Entrance door fixed with complete fixtures fixed in repair complete all as specified.
Magic eye in Entrance door including filling gaps in door with putty work fixed in repair complete all as specified.
20mm thick Granite of Ist quality, table rubbed and polished as in steps, jambs, pillars, window-cill, cooking platform, working table and like set in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, over and including rendering 10 mm thick in cement mortar 1:3 complete all as specified and as directed.
Marble tiles (Baroda / Udaipur green) 18 to 20mm thick machine cut as in flooring, including 20mm thick screed bed in CM 1:4, jointed and pointed with grey cement slurry and pointing with white cement (1:3) using marble dust with admixture of pigment to match with shade cutting and polishing complete all as specified and directed.
Vitreous China wash down water closet white with concealed S-Trap/P-trap, 360mm wide, 390mm high and 415 to 445mm long at top including fixing bolt Plastic water closet seat cover white closed pattern with flat bottom and cover and mild steel chromium plated hinging device including connection to drain (or outgoing pipe) and to flushing pipe antisyphonage pipe fixed in repairs / replacement complete all as specified and directed.
Vitreous china semi-pedestal pattern (Anglo-Indian type) white with P or S trap, connection to trap, and to flushing pipe, antisyphonage pipe, etc. including making good to floor, water closet seat cover, with flat bottom, and mild steel chromium plated or aluminised hinging divice fixed in repair / replacement complete all as specified and directed.
Vitreous china wash Hand basin size 550 x 400 mm including waste pipe and waste coupling chromium plated, brackets and cutting for and pinning in ends of brackets or errecting stand but excluding taps, chain and plug fixed in repair / replacement complete all as specified and directed.
Pillar tap brass 15mm bore, with capstan head chromium plated fancy type screwed down high pressure with long screwed shanks and fly nuts, screwed for iron pipe fixed in repairs complete all as specified and directed.
PVC connection 450 mm long 15mm size with PTMT nuts complete fixed in repairs complete all as specified and directed.
Demolition of reinforced cement concrete in ground floor and paving in any position below or above ground level complete all as specified and as directed.
RCC Nominal mix type A1 1:1.5:3 (using 20 mm graded crushed stone aggregate) as in Chajjas complete all as specified and directed.
Use and waste of Form work to Chajjas, chullah hoods, troughs and similar items including edges and rough finished surfaces complete all as specified and directed.
Mild steel CRS bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
Mild steel CRS bars 6mm to 8mm dia in stirrups and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
Taking down cement plaster of any description incl raking out joints, hacking for key, scrubbing down with water complete all as specified and directed.
Rendering 15 mm thick on fair faces of brick work or concrete surfaces as on fair face of brick work or concrete surfaces, in CM 1:6 finished even and smooth without using extra cement complete all as specified and directed.
Rendering 15 mm thick on fair faces of stone masonry surfaces or concrete surfaces on wall in CM 1:4 finished even and smooth without using extra cement including mixing Integral Water proofing treatment (where ever required as directed by Engineer in charge) complete all as specified and as directed. Note : Water proofing compound will be measured and paid separately).
Preparation of newly plastered surfaces of walls and applying one coat of white putty 2mm thick and further applying two coats of oil emulsion distemper over a coat of wall primer complete all as specified and directed.
Preparation of New plastered surfaces and applying two coat of first quality weather proof acrylic paint exterior grade on external surfaces complete and complete all as per manufactures and directed by Engr-in-charge.
Preparation of plastered wall surfaces incl necessary racking with wire brush the surface of wall to remove all the loose laitence & wash with clean water and crack filling with acrylic putty as directed on site wet the wall prior to over coating brush apply 1 primer coat of Dr fixit Primeseal incl crack filling with Dr Fixit Crack 'X' Paste & allow to dry for 4 hours, for internal walls, apply damp proof coating and Blend a mixture & water in the ratio 1:1:1(Base: Hardner: Water) & brush apply 2 coat over the plastered surface in a span of 4 hrs and applying matching decorative finish complete all as specified and directed.
Preparation of plastered wall surfaces incl necessary racking with wire brush the surface of wall to remove all the loose laitence & wash with clean water and crack filling with acrylic putty as directed on site wet the wall prior to over coating brush apply 1 primer coat of Dr fixit Primeseal incl crack filling with Dr Fixit Crack 'X' Paste & allow to dry for 4 hours, for external walls, apply damp proof coating and Blend a mixture & water in the ratio 1:1:1(Base: Hardner: Water) & brush apply 2 coats of weather proof Acrylic paint over a coat of primer in a span of 4 hrs and applying matching decorative finish complete all as specified and directed.
Preparation of plastered wall surfaces incl necessary racking with wire brush the surface of wall to remove all the loose laitence & wash with clean water and crack filling with acrylic putty as directed on site wet the wall prior to over coating brush apply 1 primer coat of Dr fixit Primeseal incl crack filling with Dr Fixit Crack 'X' Paste & allow to dry for 4 hours, for ceiling surfaces, apply damp proof coating and Blend a mixture & water in the ratio 1:1:1(Base: Hardner: Water) & brush apply 2 coat over the plastered surface in a span of 4 hrs and applying matching decorative finish complete all as specified and directed.
Preparation of plastered wall surfaces incl necessary racking with wire brush the surface of wall to remove all the loose laitence & wash with clean water and crack filling with acrylic putty as directed on site wet the wall prior to over coating brush apply 1 primer coat of Dr fixit Primeseal incl crack filling with Dr Fixit Crack 'X' Paste & allow to dry for 4 hours, for on flat and slooping roof, apply damp proof coating and Blend a mixture & water in the ratio 1:1:1(Base: Hardner: Water) & brush apply 2 coat over the plastered surface in a span of 4 hrs and applying matching decorative finish complete all as specified and directed.
Special treatment of sunken portion of WCs and Bath room as per following stages upto depth 50cm depth : Stage 1: Demolition of WC including lime concrete and cement concrete coba etc and preparing the surfaces of existing sunken portion of WCs or bath etc with wire brush to remove all loose dirt, oil grease etc . Stage 2:- Providing 10mm thick plaster in CM 1:4 with chemical of plaster seal. Stage 3:- Applying Dr Fixit Primseal primer or STP Ltd(and allow to dry for 8 hours) under touch dry condition Stage 4:- Applying two coats of water proofing of Dr Fixit Pidicrete for the sunken portion of toilets/bathrooms (The surface after painting one coats shall be allowed to dry of 6 hours before next coats) all as per manufactutrer instruction Stage 5:-Again rendering 10mm thick in CM 1:4 mixed with Dr Fixit Pidicrete URP or plaster seal of STP Ltd. Stage 6. All CI joints shall filled with mixture of cement fine sand and plaster seal of STP Ltd or Dr Fixit pidicrete URP Stage 7. Applying bituminous primer @ 0.40 litre per Sqm over plastered surfaces of roof and layer of APP based polymeric membrane of approved manufacturer, 3 mm thick, weight not less than 3.0 Kgs per Sqm, reinforced with non wovwn polyster fabric or weight not less 160 gms per sqm. Polymeric membrane shall be taken to a height of 60 cm minimum) and then inserted insde the groove of parapet wall and shall be finished by a membrane flashing. Stage 8:- Making holes in wall and fixing 600mm long 25mm dia GI spout for draining the surplus water if any. Make : Dr Fixit, Krishna, Sika, Chemistik or Equivalent make approved by GE
PCC 1:5:10 type E2 using 40 mm graded crushed stone aggregate as in sunken floor filling and mass concrete or as in sub base complete all as specified and directed.
Vitreous china white squatting pan Orissa pattern of size 580mm x 440 mm with integral foot rests including necessary lime concrete and 100 mm bore cast iron ‘P’ trap with 550 to 600 mm long neck for connecting WC to branch piece with cement joints, fixed in repair, complete all as specified and as directed.
10litres capacity PVC flushing tank, syphonic action type, high / low level, valveless, with PVC inlet ball valve, PVC flush pipe, float, including taking down / dismantling old unserviceable flush tank (any type) and disposing off fixed in repair / replacement complete all as specified and directed.
Dismantling U/s CI Pipe/PVC along with fitting of 50/75/100 mm dia or any size, below or above ground level, jointed in cement mortar and taking out complete all as specified.
PVC (SWR) pipes, 110mm bore, single socketed, 4.00 Kgf per Sqcm pressure, in any length with rubber ring joints complete all as specified and as directed.
110mm bore PVC (SWR) bends, single / double 'Y' or 'T', with access doors, any radius including fixing clips complete all as specified and as directed.
PVC (SWR) pipes, 75mm bore, single socketed, 2.50 Kgf per Sqcm pressure, in any length with rubber ring joints complete all as specified and as directed.
75mm bore PVC (SWR) bends, single / double 'Y' or 'T', with access doors, any radius including fixing clips complete all as specified and as directed.
PVC (SWR) vent cowl of size 110mm complete all as specified and as directed.
PVC (SWR) vent cowl of size 75mm complete all as specified and as directed.
75mm PVC (SWR) floor trap, plain including jointing with solvent cement and white cement complete all as specified and as directed.
PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement fixed in repair / replacement complete all as specified and as directed.
Stainless steel Grating square 150 mm size openable type (Minimum weight 100gms) fixed in repair/replacement complete all as specified and directed.
Taking up or down existing steel water tubing of any size alongwith connections fixed/laid in any situation complete all as specified
CPVC tubing, 16mm bore including fittings such as bends, tees, elbows, short pieces, connectors, back nuts and connections fixed in new or old position (walls, ceiling, floors) complete all as specified and directed.
Bib tap ,brass 15mm bore, concealed type with capstan head chromium plated, with wall flange, fancy type screwed down high pressure with long screwed shanks and fly nuts, screwed for iron pipe fixed in repair complete all as specified and directed.
CP brass wall mixer for mixing hot & cold water screwed down for iron pipe fixed in repair / replacement complete all as specified and directed.
15mm bore fancy type CP brass Stop cock / Angle valve with wall flange fixed in repair / replacement complete all as specified.
Dismantling Plain or corrugated steel sheeting, any type / gauge, thickness and any patten of roof coverings, hanger door, hanger roof complete all as specified.
High tensile galvalume sheets colour coated single skin plain Galvalume sheeting in ridge and cladding having 1000-1020 mm width manufactured out of 0.50 mm TCT (total coated thickness) cold rolled steel, having yield strength 550MPa minimum and wall coated with 25 micron modified polyester paint system applied on Zincalume on top and with back coating on sheet shall be 7-10 micron epoxy paint. The sheet shall be supplied in length maximum upto 6-12 meters long to suit with structural dimensions and fixed with self tapping screws with built in gasket (with bitumen washer) of suitable size machine fixed as per manufacturer instructions and applying adhesive compound to joint overlap of sheets complete all as specified and directed by Engineer-in-Charge.
Bituminious sheet pieces of size 100mm x 100mm on J/L hooks fixed with nut & washers on the roof of existing hangers including filling with water profing sealent complete all as directed by Engineer in Charge.
GI Sheet Rubberized Adhesive Repair Tape with Strong Silicone Sealant,Seal Leaks & Patch Roofs , repair 152.3 cm Gorilla Tape Roof sealing joint compound material to obtained gap & holes surface of Galvalume GI based Corrugated roof surfaces and filling complete gap etc complete all as specified and as directed by Engineer In Charge. Note:This work will be carried at site by own arrangement of contractor in hanger roof without any extra cost to the Government.
Hydraulically pressed burnt clay tile plain of size 200x200x19/20mm machine made laid over & including cement mortar screed 15mm thick in CM 1:6 mixed with water proofing compound and jointed pointed in CM 1:3 mixed with 5% crude oil by weight of cement complete all as specified and as directed by Engineer In Charge.
Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc. laid dry bedded in any mortar complete all as specified.
20mm thick Granite machine cut, in skirting/dado door window sill, jambs etc laid over cement screed (1:3) and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade ofgranite stone including grinding and polishing complete all as specified.
Demolition of unreinforced cement concrete in ground floor and paving n.exc 15 cm thick below or above ground level complete all as specified and directed.
Water proofing treatment to RCC roof slab including parapet comprising with the following course of treatment / specification from bottom to top:- (a) Applying bituminous primer @ 0.40 litre per Sqm over plastered surfaces of roof including parapet surfaces. (b) one layer of APP based polymeric membrane of approved manufacturer, 3 mm thick, weight not less than 3.6 Kgs per Sqm, reinforced with non woven polyester fabric or weight not less 150 gms per sqm. Polymeric membrane shall be taken to a height of 60 cm 9 minimum) and then inserted inside the groove of parapet wall and shall be finished by a membrane flashing. Note:- (i) Laying of APP based membrane shall be done by torch on method and as per manufacturer's instructions. (ii) A minimum overlap of 150 mm and 100 mm should be made in the end and sides of the polymeric membrane respectively and all overlaps and joints are properly sealed as per manufacturer's instructions. (iii) Applying two coats of Bituminous aluminium paint on top of APP membrane.
10 mm thick (average) plastering on concrete surfaces in cement mortar 1:4, in order to maintain proper slope and base over existing roof surfaces for laying of APP based polymeric membrane, add WPC @3% of cement weight incl WPC , finished even and smooth without using extra cement complete all as specified and as directed. (Note:- Polymeric membrane will be measured and paid separately)
Plain Cement concrete (1:2:4), type B-0 using 12.5mm graded crushed stone aggregate min radius of 75mm as in covet fillet in roof and parapet wall junction, roof benching, kerbs, mud stop, coping, rounded or chamfered on edges, filling rails embedded sec, surface/channels and benching for manhole and haunching around manhole frame, sloping on roof top surfaces including necessary form work, finishing even and smooth without using extra cement, complete all as specified and as directed.
Providing and applying of silicon sealent in construction joint, window glass,polycarbonate sheets and required places to make joints water tights, after racking out of joints/cracks wherever necessary & throughtout cleaning at different level complete all as specified and as directed by Engineer-In-Charge.
Cutting out trees with roots in brick / slab roof surfaces (accessible & in accessible roofs) with necessary chemical treatments incl filling with PCC B0 (1:2:4) 12mm grated stone aggregates with water proofing chemicals complete all as specified.
Disconnecting existing tanks exc 500 and n.exc 1000 ltr cap, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position with Cleaning, repairing, incl complete connection with inlet and outlet with GI / CPVC pipe fitting, Float valve etc Complete all as spd and as directed by Engineer in Charge.
Dismantling of existing tank exc 500 and n.exc 1000 litres capacity complete all as specified and directed.
Rotational moulded polyethylene water storage tanks 500 ltr capacity (cylindrical vertical with closed top) hoisted and fixed in position with inlet outlet with suitable PVC Float Valve etc connections all as specified in SSR Part I including dismantling of existing tank of any description, capacity complete all as specified and directed.
Rotational moulded polyethylene water storage tanks 1000 ltr capacity (cylindrical vertical with closed top) hoisted and fixed in position with inlet outlet with suitable PVC Float Valve etc connections all as specified in SSR Part I including dismantling of existing tank of any description, capacity complete all as specified and directed.
Pre-cast RCC 1:2:4 type B1 (using 20mm graded stone aggregate) as in cover slab for drain and set in cement mortar 1:6 including dismantling of damaged RCC covers slab complete all as specified and as directed. NOTE : Reinforcement will be measured and paid for separately under relevant Item(s).
Annual maintenance of Complete checking of electronic circuits of CCR (Constant Current Regulator) 4KW Thyristor type NASU Make CCR: (NS/CCR/10/2015/04) repairing of defective CCR by identifying the fault, repairing of defective PCB's and other components and service the same, i/c calibration of CCR and complete checking, servicing on quarterly basis etc. as required & as under specified herein after as directed by Engineer-in-Charge. a) Cleaning of the system like moving parts, contactor, switch gear switches relays, by CTC contact cleaner/ cleaning the unit by blower. b) Checking, Cleaning out all cards i.e. printed circuit assembly like control cards & power supply card with CTC contact cleaner. c) Testing Power Supply service point i.e. unregulated Positive & Negative Supply and regulated power supply. d) Checking of control cards primary / secondary voltage of the Transformer and setting right as required. e) Checking servicing pulses with fuse silicon control rectifiers and setting and calibration etc complete. f) Checking the system by switching on the unit and test electrical parameter, input / output voltage & current levels actual connected load and testing for each current level and setting the same 1 Amp to 6 Amp complete. g) Observe IP & OP condition parameters and runway light fitting intensity as per requirement, and testing the unit operation from remote panel at ATC, charging the unit on load condition for two hours for satisfactory working.
Note:- 1) The above Item Includes following a) Labour Charges tools/gauges for Major and Minor repairs including Overhauls b) Labour charges for all unlimited Breakdown Complaints related to CCR for a period of one year c) Preventive Maintenanace 4 visit in a year (qtrly based ) to carry out Inspection /Checking /Maintenanace of CCR As per standard testing procedure of CCR & submission of Test Report duly signed by Engr-In-Charge, Authorised CCR Service Partner & Contractor for every qtrly Visit. Note:- 2) The above Item excludes following a) Cost of consumables and spares parts require for preventive or breakdown Visits.
S& F of following mentioned parts of CCR including disconnecting and taking down exiting unserviceable defective parts & testing on fixed in repair / replacement completion all as specified and directed.
Main Control Card including RMS to DC converter Card.
Power Supply + Driver Card.
Insulation Monitor Card.
Over Current Trip
Relay Card
TTM Card ( 1set consisting of 2 cards)
Plug in type Relays 24 VDC
Plug in type Relays 48 VDC suitable for 11 pin socket
Plug in type Relays 240 VAC
TI 300 Trip indication fuses
High speed Semi- conductor Protection Fuses :GSB 50
Thyristor : 65 RK 160
HRC Fuse Link 32 Amps
HRC Fuse Link 20 Amps
HRC Fuse Link 4 Amps
Digital TRUE RMS METERS : 10 Amp/ 1 Amp
100 Micro Amp DC coil moving meter (96 x96)
Lighting Arrestors 4. 5 KV grade
2 Pole 8 Way Brilliancy Switch (Rotary wafer, MBB type
Power Transistors MJ11016
Supply of Contactors suitable for NASU make 4 KW CCRs.
Supply of following LED Indicating Lamp Green /Yellow/Red suitable for existing Nasu Make CCR.
Bi-pin lamp holder for 45 Watt halogen lamp of Runway / Taxiway light fittings fixed in repair / replacement complete all as specified and directed. Make - AMA or equivalent make as approved by GE.
Isolating transformer 45 Watt, 6.6 Amp, 5 KV Grade of runway light fittings fixed in repair / replacement complete all as specified and directed. Make - BILDAL INDIA /AMA or equivalent make as approved by GE.
Halogen lamp 45 Watt, 6.6 Amps for runway light fitting including taking down & removing unserviceable lamp fixed in repair / replacement complete all as specified and directed. Make - AMA or equivalent make as approved by GE.
Connector kit male/female suitable for runway copper cable 6 Sqmm or 16 Sq mm including breaking coupling for AMA AVN runway light fitting male/female type fixed in repair / replacement complete all as specified and directed
Cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric power cable (Heavy duly) with stranded copper conductor cross sectional area 6 sqmm 1 core suitable for working on 5000 Volts earthed system, laid in tranches, in floor, in ducts, through pipe or along pole complete all as specified and directed. Note :- Excavation, earthwork, sand cushioning, PCC protection cover, GI pipe and protection clamps shall be measured and paid for separately.
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, pipe line, cable, etc. n exc 10 sq m on plan and getting out in hard/ dense soil complete all as specified and directed.
Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exc. 25 cm deep as in soil complete as specified.
Removing excavated material (soil/rock) to outside MD land and depositing where directed at a level not exc 1.5m above the starting point, complete all as specified and directed.
Double Walled Corrugated (DWC) HDPE pipe of size 63 mm outer dia and 50 mm inner dia conforming to IS 16205 Part - 24 Including necessary bends, coupling, tees, reducers, spacers, end caps, rubber rings etc having pressure rating not less than 450 N through trenches/wall/floor/on pole in any type of soil for protection of electric cable fixed in repair / replacement complete all as directed by Engr-In-Charge.
Jef Ecosafe Maintenance free and Environment Friendly Earth Electrode set comprising of 17.2mm dia 3 mtrs long rod of Low carbon steel, molecular Copper Bonded for a thickness of 250 microns, highly conductive ANSI NSF STD 60 Certified, with 1Bags(50P) of environment friendly carbon based backfill compound, according to BS 7430 & IEEE 80 and with suitable Clamp in 100mm dia GI pipe bore hole including Suitable FRP Chamber Copper earth stip of size 32 x 6 mm including installation 7.5 Mtr testing complete all as specified
Air termination, single pointed copper rod 12mm dia and 300mm long fixed in repair / replacement complete all as specified and as directed by Engr-in-charge.
Earthing continuity galvanised iron strip 32 x 6 mm or main earthing lead fixed to wall with clamps or recess or croses or buried in ground or drawn in conduits/pipe or fixed to poles or any other indicated situation for loop earthing etc as required fixed in repair / replacement complete all as specified and directed by Engr-in-Charge.
Aluminium strip 25 x 3.15 mm buried in ground for earthing fixed in repair / replacement complete all as specified and directed by Engr-in-Charge.
Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw fixed in repair / replacement complete all as specified and directed by Engr-in-Charge
Flood light of minimum 70W luminaire grey powder coated dire-cast aluminium housing, built in control gear faceted anodised aluminium reflector heat resistant toughened clear glass cover fixed in repair / replacement complete all as specified and directed.
SHREEJI ENTERPRISE
BABUBHAI BHIMABHAI PANDAVADRA
OM ENTERPRISE
SURESH ELECTRICALS
shree chamunda enterprise
SURAJ ENTERPRISE
AADESH CONSTRUCTION
J J ENTERPRISES
Bidder Name
J J ENTERPRISES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .