| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.2 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹14.5 L+₹29,703.80 (2.09%)Rejected-Finance | L2 | Rejected-Finance L2 |
Tender Value
₹14.7 L
EMD Value
₹22,030
Closing Date
22 Nov 2021, 2:30 pmClosed
REGISTRAR
REGISTRAR Kerala University of Health sciences MEDICAL COOLEGE PO THRISSUR
construction of toilet block near academic block
2021_KUHS_449365_1
18631/2021/A1/15/Works/KUHS
Open Tender
Civil Works - Buildings
Item Wise
120 days
Kerala University of Health sciences
Please refer Tender documents.
11 documents required · 11 mandatory
₹3,095
₹22,030
Yes
6 May 2024
30 Oct 2021
24 Nov 2021
30 Oct 2021
22 Nov 2021
30 Oct 2021
30 Oct 2021 - 22 Nov 2021
Amount
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas(exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds ofsoil
Random rubble masonry with hard stone in foundation and plinth including levelling up with cementconcrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinthlevel with:Cement mortar 1:6 (1 cement 6 coarse sand)
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
Providing and fixing up to floor five level precast cement concrete solid block, including hoisting andsetting in position with cement mortar 1:3( 1 cement : 3 coarse sand), cost of required centering, shuttering complete:1:1.5:3 ( 1 cement : 1.5 coarse sand (Zone III): 3 graded stone aggregate 20 mmnominal size)
Providing and laying in position cement concrete of specified grade excluding the cost of centering andshuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
Providing and laying in position cement concrete of specified grade excluding the cost of centering andshuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40nominal size)
Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 150 landings,balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floorfive level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement :1.5 coarse sand (Zone III) : 3 graded stone aggregate 20 mm nominal size).
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position andbinding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more
Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases ofcolumns, etc for mass concrete
Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs,landings, balconies and access platform
Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams,
12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)
Applying one coat of water thinnable cement primer of approved brand and manufacture on wallsurface:Water thinnable cement primer
Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied@ 1.67 ltr/10 sqm over and includingpriming coat of exterior primer applied @ 2.20 kg/10 sqm)
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work
Providing and fixing I st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to bespecified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green,black of any size as approved by Engineer -in-Charge, in skirting, risers of steps and dados, over 12 mmthick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kgper sqm, including pointing in white cement mixed with pigment of matching shade complete.
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by themanufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours such as White, Ivory,Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), includingpointing the joints with white cement and matching pigment etc., complete
Providing and laying PVC pipes including all PVC<br> fittings This includes jointing of pipes & fittings withone step PVC solvent cement ,trenching ,refilling & testing of joints complete as per direction of Engineerin Charge. 63 mm(10kg/cm2) nominal outer dia Pipes
Providing and laying PVC pipes including all PVC<br> fittings This includes jointing of pipes & fittings withone step PVC solvent cement ,trenching ,refilling & testing of joints complete as per direction of Engineerin Charge. 110 mm(10kg/cm2) nominal outer dia Pipes
Providing and fixing PVC pipes including all PVC plain fittings, i/c fixing the pipe with clamps at 1.00 mspacing. This includes jointing of pipes & fittings with one step PVC solvent cement and the cost ofcutting chases and making good the same including testing of joints complete as per direction ofEngineer in Charge. Concealed work, including cutting chases and making good thewalls etc 20mm(10kg/cm2) nominal outer dia Pipes
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seatand lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlleddevice (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting andmaking good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seatand lid
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass wasteof standard pattern, including painting of fittings and brackets, cutting and making good the wallswherever require:White Vitreous China Flat back wash basin size 550x400mmwith single 15 mmC.P.brasspillar taps
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) completewith 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washerscomplete
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screwswith concealed fitting arrangement of approved quality and colour450 mm long towel rail with total lengthof 495 mm, 78 mm wide and effective height of 88 mm. weighing not less than 170 gms
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards andweighing not less than 690 gms.15 mm nominal bore
Providing and fixing PTMT Soap Dish Holder having length of 138 mm, breadth 102 mm, height of 75 mmwith concealed fittings arrangements, weighing not less than 106 gms.
Providing and fixing floor trap of pvc,110mm outer dia including cp grating as directed by Engineer-in-Charge
Providing and fixing approved make Health faucet with flexible pipe and wall hook, 1no. CP brass anglevalve of approved make with CP cup as directed by Engineer-in-charge
supplying and fixing large flat back urinal basin(440x360x270mm)size with 15mm cp angler cock, cpspreder with cp connection pipe,cp gratings,TW plugs,screws etc including all labour cutting & makinggood wall etc.complete as directed by the engineer in charge
Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc.,including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting thesame with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessaryaccessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of thefloor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (forpayment purpose only weight of stainless steel members shall be considered excluding fixingaccessories such as nuts, bolts, fasteners etc.)
Providing and fixing ISI marked oxidised M S door latches conforming to IS : 5930 with screwsetc.300x20x6 mm
Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC10 as per : 1868), transparent or dyed to required colour or shade, with necessary screwscomplete:200x10 mm
Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mmhaving single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall bemoulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminateshall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall becovered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame
Providing and fixing to existing door frames.30 mm thick Fiberglass Reinforced Plastic (F.R.P) flush doorshutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin,moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places forfixing of fittings and polyurethane foam (PUF) / Polystyrene foam to be used all filler material throughoutthe hollow panel, casted monoolithically with testing parameters of F.R.P. laminate conforming to table -3 of IS : 14856, complete as per direction of Engineer-in-charge
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built upstandard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS :733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up thegaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc.Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically whereverrequired including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steelscrews, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing,paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium(minimum thickness of powder coating 50 micron)
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded woodparticle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windowsshutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architecturaldrawings and directions of Engineer - in- Charge.Pre-laminated particle board with decorative laminationon one side and balancing lamination on other side
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDMrubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer -in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0mm thickness
Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M - 30 grademade by block making machine with strong vibratory compaction, of approved size, design & shape, laidin required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling thejoints with fine sand etc. all complete as per the direction of Engineer-in-charge.
AKHIL KRISHNA K
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_641373.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .