Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹43.0 LAccepted-AOC | 1 | Accepted-AOC L1 Bidder | |
| 2 | 2₹44.4 L+₹48,340 (1.10%)Rejected-Finance | 2 | Rejected-Finance Not L1 Bidder | |
| 3 | 3₹45.8 L+₹1.9 L (4.42%)Rejected-Finance | 3 | Rejected-Finance Not L1 Bidder | |
| 4 | 4₹45.8 L+₹1.9 L (4.42%)Rejected-Finance | 4 | Rejected-Finance Not L1 Bidder | |
| 5 | 5₹46.2 L+₹2.2 L (5.11%)Rejected-Finance 1 12F GOPAL CHANDRA BOSE LANE KOLKATA 700 050 | KOLKATA | KOLKATA | WEST BENGAL | 700050 | 5 | Rejected-Finance Not L1 Bidder |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
8 Sept 2023, 4:00 pmClosed
GE NORTH KOLKATA
GE NORTH KOLKATA 46 BT ROAD KOLKATA 50
COMPREHENSIVE MAINT OF MINOR STRUCTURAL REPAIRS ROOF TREATMENT PLASTERING FALSE CEILING JOINERIES ALUMINIUM FRAME AND DOORS SANITARY FITTINGS TRUSSES GIRDERS VALLEY GUTTERS RIDGES VERTICAL SHEETING WALL DAMAGES RUSTED ANGLES CHAJJA FINS FACIA PARAPE
2023_MES_613150_1
8289/23-24/GE(N)/KOL/E8 OF 2023-24
Open Tender
Miscellaneous Works
Item Rate
210 days
507 ABW
AS PER TENDERDOCUMENT
8 documents required · 8 mandatory
₹500
GE NORTH KOLKATA
₹80,000
Yes
12 Oct 2023
10 Aug 2023
9 Sept 2023
11 Aug 2023
8 Sept 2023
25 Aug 2023
Amount
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing and rubbish off the premises complete all as specified and as directed.
Material and labour for Non-skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tiles exceeding 0.11 sqm but not exc 0.18 sqm as in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over and including 15mm thick screed bed or bedding layer in CM(1:6) complete all as specified and directed.
Material and labour for glazed ceramic coloured tiles (300x200) x7mm thick in skirting/ dados etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour tiles over and including 10mm thick rendering in CM(1:4) complete all as specified and directed.
Material and labour for light shade vitrified tiles 10mm thick (square/rectangular) polished, area of each tiles n.exc. 0.36 of each tile in floor set and jointed in neat cement slurry & pointed in white cement and pigment to match the colour of tiles over and including 15mm thick screed bed in cement mortar (1:6) complete as specified and directed.
Material and labour for light shade vitrified tiles 10mm thick (square/rectangular) polished, area of each tiles n.exc. 0.36 sqm in skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour tiles over and including 10mm thick rendering in CM(1:4) complete all as specified and as directed.
Supply and fix in repairs stainless steel sink with drainage board made out of 1 mm thick sheet for kitchen with plug washers, waste pipe including bedding in cement mortar on dwarf wall or including cast iron cantiliver brackets connecting union overall size 915 X 460 mm with bowl size 405x355x178mm or 410x357x178mm complete all as specified and as directed.
Supply and fix in repairs stainless steel sink without drainage board made out of 1 mm thick sheet for kitchen with plug washers, waste pipe including bedding in cement mortar on dwarf wall or including cast iron cantiliver brackets connecting union overall size 495 X 420 mm with bowl size 410x330x160mm or 410x357x178mm complete all as specified and as directed.
Supply and fix in repair stainless steel kitchen Plate Rack of size 24''x36''x10'' complete all as specified and as directed.
Material and labour for machine cut cudappah stone slab 20-25mm thick over cement screed base, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing, rounding edge and polishing complete all as specified and directed.
Supply and fix in repair vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests including 'P'or 'S' trap (excluding flushing cistern and flush pipe) including provision of lime concrete bedding complete all as specified and as directed.
Supply and fix in repair vitreous china wash down water closet pan, semi pedestal pattern (Anglo Indian Type), white including plastic water closet seat, white closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device suitable for Anglo Indian Type pedestal pan (excluding flushing cistern and flush pipe) complete all as specified and as directed.
Supply and fix in repairs vitreous china wash hand basin white flat back, size 630 x 400 mm including PTMT waste coupling 32mm dia (min wt 45 gm), chain, plug and porcelain stopper etc. complete all as specified and as directed.
Supply and fix in repair brass chromium plated tubular towel rail , 20mm dia, D type, 600mm long between flange fixed with chromium plated brass screws complete all as specified & directed.
Supply and fix in repair soap dish, vitreous china white approximate size 160x160x90mm and fixed in position complete all as specified & directed.
Taking down/dismantling loose/damage concrete including plaster of any description and in any position from RCC structures like chajja, fins, roof ceiling,louvers, parapet, column, beam, and lintel by hammering with wooden mallets carefully chipping off the old concrete surface with necessary scaffolding including cutting of rusted reinforcement if so required and disposal of old debris to outside the premises complete all as specified and as directed.
Demolition of reinforced concrete as in roofs, floors (other than ground floors), beams, staircases, landing, and similar suspended work (reinforcement cut as required to facilitate demolition) with necessary scaffolding and protection as required complete all as specified and as directed.
M & L for cleaning the existing surface of concrete and reinforcements as obtained after execution of item No. 15 & 16 here in before by wire brush including scrapping & cleaning with emery paper and washing down with water as required and applying “Solvent free epoxy concrete bonding agent” as per manufacturer’s instructions on old concrete surfaces for bonding with new concrete complete all as specified and as directed.
M & L for applying two coats of “Epoxy zinc rich primer” as protective coat to expose surface of old and new reinforcement over 10 mm dia as per manufacturer's instructions complete all as specified and as directed.
All as per item No.18 above but reinforcement upto 10mm dia complete all as specified & directed. Note for item No 17 to 19 : (i) Cost of chemical i.e. Solvant free epoxy, Epoxy zinc rich primer and cement shall be measured and paid separately under appropriate item here in below. (ii) The work shall be carried out by the trained person as per manufacturer's instructions i.e. FOSROC/SIKA/ PIDILITE
Supply only epoxy zinc rich primer complete all as specified & directed. Make : Nitozinc primer of FOSROC/Friazinc R of SIKA/ or equivalent in PIDILITE
Supply only Solvent free Epoxy concrete bonding agent complete all as specified & directed. Make : Nitobond EP of FOSROC/Hybond of SIKA/ or equivalent in PIDILITE.
Material and labour for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending lapping etc as required and welding with existing bar complete all as specified and as directed.
Material and labour for TMT bars 6 to 8mm dia, cut to length, bent to shape required, including cranking, bending, lapping etc as required and welding with existing bar complete all as specified and as directed.
Material and labour for TMT upto 10mm dia as in stirrups cut to length bent to shape required including cranking ,bending etc and lapping ,welding as directed to the existing one complete all as specified and as directed.
Material and labour for providing reinforced cement concrete (1:1½: 3) type A1 (using 20mm graded stone aggregate) as in chajja, facia, railing and parapet complete all as specified and as directed.
Material and labour for providing reinforced cement concrete (1:1½: 3) type A0 (using 12.5mm graded stone aggregate) mixed with integral water proofing liquid admixture as per manufactures instructions as in columns, pillars, piers, posts and struts complete all as specified and as directed.
All as per item No. 26 above but in beams, lintel, cantilevers complete all as specified & directed.
All as per item No. 26 above but in suspended slab, landing, balcony and similar items complete all as specified & directed.
All as per item No. 26 above but in chajja, facia, railing and parapet complete all as specified & directed.
M & L for use and waste of formwork to the sides of pillars, posts, struts, piers, columns and stanchions for rough finished concrete surfaces complete all as specified and as directed.
M & L for use and waste of formwork to sides and soffits of beams, lintels, floors etc. for rough finished concrete surfaces complete all as specified and as directed.
M & L for use and waste of formwork to parapet, RCC wardrobe and similar items for rough finished concrete surfaces complete all as specified and as directed.
M & L for use and waste of formwork to sides and soffits of chajja, troughs etc for rough finished concrete surfaces complete all as specified and as directed.
Material and labour for 5 mm thick plastering in CM (1:3) on concrete surfaces as in sides of column, lintel, beam, chajja, facia, railing, RCC wardrobe etc including finish the surface even and fair without using extra cement complete all as specified and as directed.
All as per item No.34 above but in ceiling complete all as specified & directed..
M & L for preparation of new plastered surfaces of wall and applying two coats of cement base paint complete all as specified and as directed.
M & L for preparation of new plastered surfaces of wall and applying two coats of oil bound distemper over a coat of alkali resistant primer complete all as specified and as directed.
M & L for preparation of new plastered surfaces of wall and applying three coats of white wash complete all as specified and as directed.
All as per item No. 38 above but in ceiling complete all as specified & directed.
Taking down chowkats/frames (wooden, steel, Aluminium) with single or double shutter (without taking off shutter from the frame) exc 1.50 and not exc. 4.00 Sqm in each complete all as specified and directed.
Taking down chowkats/frames (wooden, steel, Aluminium) with single or double shutter (without taking off shutter from the frame) n. exc 1.50 Sqm in each complete all as specified and directed.
Taking down shutters only of any description exe 1.0 sqm and n exe 2.0 Sqm each opening complete all as specified & directed.
Material and labour for 2nd class hardwood in plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed complete all as specified and as directed .
Material and labour for Pressed steel frames 105mm x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc and fixed complete all as specified and as directed .
Material and labour for Pressed steel frames 125mm x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc and fixed complete all as specified and as directed .
Material and labour for cement concrete type B0, (1:2:4) (using 12.5 mm graded aggregate) in door and windows frames, any size, single or double rebated, including arrangement for fixing of hinges and fixtures as required complete all as specified and as directed .
Material and Labour for PCC (1:3:6) type C-1 using 20 mm graded stone aggregates as in block for fixing of hold fast and similar items complete all as specified and as directed.
Supply and fix 35mm thick 2nd class hard wood factory made plain framed panelled door shutters, (single panel) without lock rail and panel of 12mm veneered particle board with commercial veneered on both faces and rail and stiles as per IS 1003(Pt-I), kiln seasoned and chemically pressure treated etc. complete all as specified and as directed.
Supply and fix 35 mm thick, glazed/skeleton shutters with second class hard wood,open rebated and prepared to receive glass, gauze, etc (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut mitred beads for securing glass, etc complete as specified and directed . Sizes of members of shutters as specified in SSR Part I, Section -8, clause 8.24 (a) complete all as specified and directed.
Supply & fix 100 mm long MS Butt hinge , medium weight , cold rolled complete all as specified and as directed .
Supply and fix 2nd class HW Small fittings such as door stop of n.exc 200 cucm each complete all as specified and as directed .
Supply and fix 150mm size extruded aluminum alloy handle fabricated type anodized complete all as specified and as directed.
Supply and fix 150 mm long aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and as directed.
Supply and fix 100mm long aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and as directed.
Supply and fix 250 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and as directed.
Supply and fix Stainless steel wire cloth of 0.36 mm nominal dia of wire and average width of aperature 1.40 mm fixed with stainless steel wire staples complete all as specified and as directed.
Material and Labour for applying two coats of Synthetic enamel paint over a coat of pink primer on new wooden surface exc 10 cm width or girth including preparation of the surface complete all as specified and as directed.
Supply and fix MS holdfast made up of FI 25 X 3mm conforming to Fe-410-0 or Fe-310-0 complete all as specified and directed.
Supply and fix Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. square tube, fixing in opening as per specification & drawing complete all as specified & directed.
S&F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing complete all as specified & directed.
Supply and fix anodised aluminium frame for doors,windows,ventilators(including 2/3 track) with one or more rebated including jointing cleat for fixing etc.complete all as specified and as directed.
Supply and fix sliding aluminium anodized glazed shutter for sliding window/ ventilator with aluminium channel section weighning not less than 0.55 Kg per sqm including aluminium cleat,roller rubber neoprene packing/gasket etc complete all as specified and as directed.
Supply and fix sliding aluminium anodized wiremesh shutter for sliding window/ventilator with aluminium channel section weighning not less than 0.55 Kg per sqm including aluminium cleat,roller rubber neoprene packing/gasket etc complete all as specified and as directed.
Supply and fix aluminium designed grill for windows including jointing cleat for fixing etc complete all as specified and as directed.
Supply and fix 4.0 mm thick sheet glass ordinary quality and glazing with oil putty in square n. exc 0.50 sqm in each pane, complete as specified and as directed.
Supply and fix 4.0 mm thick sheet glass ordinary quality and glazing with oil putty in square exc 0.50 sqm in each pane, complete as specified and as directed.
Supply and fix in repairs 4.0 mm thick sheet glass ordinary quality and glazing with oil putty in square n. exc 0.50 sqm in each pane, complete as specified and as directed.
Supply and fix in repairs 4.0 mm thick sheet glass ordinary quality and glazing with oil putty in square exc 0.50 sqm in each pane, complete as specified and as directed.
Supply and fix in repair Stainless steel wire cloth of 0.36 mm nominal dia of wire and average width of aperature 1.40 mm fixed with stainless steel wire staples complete all as specified and as directed.
Supply and fix factory made PVC Cup board frame of size 75 mmX40 mm with a wall thickness of 5 mm , made out of extruded 5 mm thick plain colour PVC Sheet reinforced with 15mm X15mm MS square tube of 19 gauge thickness throughout the frame and mitred cut at two corners and jointed with 2 Nos of 150 mm long brackets of 10mmX10mm MS square tubes . The door frame shall be fixed to the wall using 65/100 mm long MS screws through the frame by using PVC fastners . A minimum of 4 Nos of screws to be provided for each vertical member and minimum of 2 Nos of screws to be provided to horizontal member , prelam colour complete all as specified and as directed.
Supply and fix factory made PVC Cup board shutter of 25 mm thick consisting of frame madeout of MS tubes of 19 gauge thicknessof size 15 mmX15 mm covered with 5 mm thick PVC 'C' channel of size 25 mm X 50 mm forming stiles , top and bottom rails . Panelling of 5 mm thick plain colour PVC sheet fitted in the MS frame welded / sealed to the stiles and rails with 25 mm wide X 5 mm thick PVC sheet beading on either side and joined togather with solvent cement adhesive . An additional 5 mm thick PVC Strip of 20 mm width is to be stuck on the interior side of the 'C' channel using PVC solvent cement adhesive etc . prelam colour complete all as specified and directed.
Supply and fix in repairs factory made PVC centre partition and shelf of 15 mm thick consisting 15 mm (5 mm X 3) 19 mm square tube, plain in colour complete all as manufacturers instructions complete all as specified and directed.
Supply and fix in repair fancy type drapery curtain rod bracket as specified and as directed.
Supply and fix in repair brass chromium plated curtain rods of 20mm dia complete all as specified and directed.
Supply and fix in repairs 15mm bore bib tap fancy type chromium plated cast copper alloy with crutch or butter fly handle complete all as specified and as directed.
Supply and fix in repairs 15mm bore bib tap standard of PTMT any colour high pressure for iron pipe and fixed (minimum weight 15 mm - 105 gm) complete all as specified and as directed.
Supply and fix in repair stop cock 15mm bore fancy type, PTMT any colour high pressure with long shank and cup, concealed type (minimum weight 15 mm- 110 gm) with long shank and cup concealed type complete all as specified and as directed.
Supply and fix in repair shower rose 125 mm size brass chromium plated, with or without swivel joints, any size including fixing to steel pipe or union complete all as specified and as directed.
Supply and fix in repair stop cock 15mm bore fancy type, chromium plated with long shank and cup concealed type cast copper alloy, screwed down, high pressure, with crutch handle, screwed both ends for brass ferrule complete all as specified and as directed.
Supply and fix in repair pillar tap of 15mm bore, cast copper alloy with capstan heads fancy type, chromium plated screwed down, high pressure, with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and as directed.
Material and labour for preparation of newly plastered surfaces of wall by Vacume based sanding machine and applying, two coats of Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance, Alkali & fungal resistance paint white or coloured by Auto Roller, including necessary scaffoldings complete all as specified and as directed.
Supply and fix in repair UPVC pipes 110 mm bore type 'A'single socketed in any length with rubber ring joint fixed to walls with and including PVC brackets complete all as specified & directed.
Supply and fix in repair UPVC bend/shoe 110mm bore complete all as specified and as directed.
Supply and fix health faucet (ABS body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 meter long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and directed.
Supply and fix steel tubes, galvanised 15 mm bore, medium grade with all fittings & fixed complete to wall and ceiling or laid in floors etc after taking up or down 15mm dia old steel tubing & connection complete as specified and directed.
Supply and fix steel tubes, galvanised 20 mm bore, medium grade with all fittings & fixed complete to wall and ceiling or laid in floors etc after taking up or down 20mm dia old steel tubing & connection complete as specified and directed.
Supply and fix 500 litres capacity rotational moulded polythene water storage tanks multilayer (cylindrical vertical, with closed top), hoisted and fixed in position as specified in SSR Part I including dismantling of unserviceable water tanks and removing from site complete all as specified and directed.
Supply and fix 1000 litres capacity rotational moulded polythene water storage tanks multilayer (cylindrical vertical, with closed top), hoisted and fixed in position as specified in SSR Part I including dismantling of unserviceable water tanks and removing from site complete all as specified and directed.
Materials and labour for 75mm thick PCC (1:3:6) type C2 (using 40 mm graded stone aggregate) as in pavement/plinth protection , laid in bays and joints shall be filled up with bituminous gola with 80/25 bitumen (1 part of bitumen to be mixed with 3 part of sand) and finished the surface fair and even complete all as specified & directed.
Demolition of cement concrete (un-reinforced) in ground floors and pavings nexc 15 cm thick (below or above ground level) complete all as specified and directed.
Material and Labour for preparation of old steel surface and applying one coat of synthetic enamel paint exc 10 cm width or girth complete all as specified and as directed.
Taking down/demolition of existing roof treatment, scale dirt etc. including racking out, hacking, scrubbing down with water, etc and removing the rubbish from the premises complete all the specified and as directed.
M&L for providing 40mm thick cement concrete 1 :2:4, type B-1 (20 mm graded stone aggregate) with and includig WPC (200 ml/Bag of cement) laid in roof and finished the surface even & smooth without using extra cement including demolition old pcc complete all as specified and as directed.
M&L for water proofing treatment with APP based standard membrane in non accessible roof with the following courses of treatment, firstly applying bituminous primer @ 0.40 kg per Sqm to the surface area including cleaning the surface and applying APP plastomeric bitumen based mineral finished water proofing membrane polyester reinforced (3 kg /sqm) with minimum 3 mm thick with 10 cm overlaps and torched bonded at joints including surface preparation before and after application of treatment as per manufactures instruction complete all as specified and as directed. Make of APP membrane : SIKA/STP/TIKITAR.
Material and labour for cleaning and removing all scale, dirt and fungus etc. from tanks and mouth of circulating pipes, with suitable cleaning chemical and brushing the wall and bottom of tanks, washing with clean water, writing letter i.e. "TANK CLEANED ON ......................(Date)" not exc. 100mm height with synthetic enamel paint for tanks of capacity 500 ltrs to 1000 ltrs complete all as specified and as directed.
Dismantling plain or corrugated steel sheeting/Galvalume sheeting any gauge , thickness , including roof covering / wall etc for the building structures complete all as specified and as directed .
Supply and fix Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.45 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified & directed.
Supply and fix Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.45mm thick of any colour having tensile strength of 550 Mpa as in Ridge, fixed with self tapping screwscomplete all as specified & directed.
Materials and Labour for hollow steel sections for structural use, designation CF, in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Circular,Square, Rectangular Hollow Sections), including distance pieces, cleats, angle iron,plate etc welding as required,including dismantling old unserviceable structural works complete all as specified and directed.
M & L for preparation of new steel surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
Material and labour for complete removal of existing treatment from old decorated plastered surfaces of wall by Vacuum based sanding machine, removal of nail etc & filling cracks/hole with putty,applying wall care putty upto 1mm thick as required (Multipurpose mixer shall be used for uniform and proper mixing of putty) and applying two coats of emulsion distemper white or coloured by Auto Roller complete all as specified and as directed.
Material and labour for complete removal of existing treatment from old decorated plastered surfaces of wall by Vacuum based sanding machine, removal of nail etc & filling cracks/hole with putty,and applying two coats of emulsion distemper white or coloured by Auto Roller complete all as specified and as directed.
Supply and fix in repair grating doom 100mm dia of SS (Minimum weight 25 gms) complete all as specified and as directed.
M & L for 75mm thick plain cement concrete (1:2:4) type B-2 (using 40 mm graded stone aggregate) and finished the surface even and fair including demolition of old PCC complete all as specified and directed.
M&L for Chequered cement concrete tiles 30cm x 30cm x 25mm thick, laid over 20 mm thick screed bed or bedding layer of mortar in CM (1:6) for laying floor finishes set, jointed with grey cement and pigment and pointed in neat cement slurry in floors including demolition of old unserviceable tiles complete all as specified and directed.
Demolition of Brickwork or stone/boulder masonry, built in cement mortar complete all as specified and directed.
Material and labour for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and as directed.
Material and Labour Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar (1:4) complete all as specified and as directed .
Taking down cement plaster on brick or stone wals, etc. including raking out joints, hacking for keys, scrubbing down with water, etc. complete all as specified and as directed .
Material and labour for rendering 15mm thick in cement mortar (1:6) on fair faces of brickwork or concrete surfaces, finished the surface even and smooth without using extra cement complete all as specified and directed.
Material and labour for preparation of newly plastered surfaces of wall by Vacuum based sanding machine , applying wall care putty 1 mm thick (Multipurpose mixer shall be used for uniform and proper mixing of putty) and applying two coat of emulsion distemper white or coloured by Auto Roller complete all as specified and as directed.
Materials and labour for rendering 20 mm thick cement plaster in cement mortar (1:4) in two layers, each 10mm thick, top layer mixed with integral water proofing liquid admixture as per manufacturers instruction on brick or concrete surfaces of wall, finished the surface fair and even complete all as specified and as directed. Note: (WPC shall be measured and paid separately).
Supply only integral water proofing liquid admixture for concrete and mortar complete all as specified and directed.
Material and labour for applying three coats of white wash on new plastered surface of wall including preperation of newly plastered surface complete all as specified and directed.
Material and labour for complete removal of existing treatment from old decorated plastered surfaces of wall by Vacuum based sanding machine, removal of nail etc & filling cracks/hole with putty, and applying two coats of Anti Fungal paint white or coloured by Auto Roller, including necessary scaffoldings complete all as specified and as directed as per manufacturers instruction.
Supply and fix in repair 10 litre capacity PVC valve less, symphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets and flush pipe of polyethylene of low or high density or PVC. 32 mm dia, for low level cistern including PVC connections 15mm size with brass nuts and washer both side of length 450mm complete all as specified and as directed.
Taking down copper / aluminium point wiring any type complete, including fixture and fittings any type removing materials for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc.surfaces, complete all as specified and directed.
Material and labour for concealed point wiring with FRLS PVC insulated 1100 volts grade unsheathed single core multi-stranded copper conductors 1.5 sqmm for phase,1.5 sqmm for neutral and 1.5 sqmm for earth continuty conductor drawn through and including PVC conduit medium grade with accessories of suitable size but not less than 20 mm and including suitable size of pressed steel sunken terminal box duly painted MS sheet and covered with suitable size thick insulated hylum sheet cover for fixing of switches, sockets etc. for one light point controlled by one switch complete all as specified as directed. Note :(i) Cost of cutting of wall, if any, for housing of GI box, ceiling rose,and pvc conduit for wiring etc and also making good the disturbed surfaces are deemed to be included in unit rate
All as per Item No. 119 above but for one ceiling fan/ exhaust fan point controlled by one switch and one regulator complete all as specified as directed.
All as per Item No. 119 above but for one 3/5pin 6 Amp Socket outlet on the independent board complete all as specified as directed.
All as per Item No. 119 above but for one 3/5pin 6 Amp Socket outlet on the same board complete all as specified as directed.
All as per Item No. 119 above but for one call bell point controlled by one switch complete all as specified as directed.
All as per item no 119 above but for FRLS PVC insulated 1100 volts grade unsheathed single core multistranded copper conductors 2.5 sqmm for fixing of 16 A switches, sockets, etc complete all as specified as directed.
Material and labour for surface point wiring with FRLS PVC insulated 1100 volts grade unsheathed single core multi-stranded copper conductors 1.5 sqmm for phase,1.5 sqmm for neutral and 1.5 sqmm for earth continuty conductor drawn through and including PVC casing caping with accessories of suitable size but not less than 20 mm and including suitable size of pressed steel sunken terminal box duly painted MS sheet and covered with suitable size thick insulated hylum sheet cover for fixing of switches, sockets etc. for one light point controlled by one switch complete all as specified as directed.
All as per Item No. 125 above but for one ceiling fan/ exaust fan point controlled by one switch and one regulator complete all as specified as directed.
All as per Item No. 125 above but for one 3/5pin 6 Amp Socket outlet on the independent board complete all as specified as directed.
All as per Item No. 125 above but for one 3/5pin 6 Amp Socket outlet on the same board .
All as per Item No. 125 above but for one call bell point controlled by one switch complete all as specified as directed.
All as per item no 125 above but for surface type point wiring FRLS PVC insulated 1100 volts grade unsheathed single core multistranded copper conductors 2.5 sqmm for fixing of 16 amp switches, sockets, etc complete all as specified as directed.
Supply and fix switch piano flush button 5 Amp single pole one way 240 volt complete all as specified as directed.
Supply and fix socket out let 3/5 pin 5 Amp 240 volt complete all as specified as directed.
Supply and fix switch socket combination 3/5 pin 5 Amp 240 volt complete all as specified as directed.
Supply and fix switch socket combination 3/6 pin 15 Amp flush type 240 volt complete all as specified as directed.
Supply and fix celling fan regulator (step regulator) switch type AC 230 volt suitable for ceilling fan any sweep complete all as specified as directed.
Supply and fix bell push 6 amps complete all as specified as directed.
S&F call bell ding dong type AC 230 volt single pole complete all as specified as directed.
S&F lamp holder PVC/Polycarbonate type with backplate suitable for batten fittings complete all as specified as directed.
Supply and fix celling rose surface, 3 terminal and ISI marked complete all as specified and directed.
Supply and fix box type luminiare, pre coated in white and pre-wired for single LED tube light 4 ft capacity suitable for single T8 LED tube rod 4ft 20 watt complete with LED tube rod T8, 20 W, 4ft long with extruded aluminium body, PC diffuser and inbuilt driver, holder, prewired fitted and connecting up with three core twisted flexible copper conductor cable of suitable size from ceiling rose to connector of tube light fitting including taking down old unserviceable fitting any type complete all as specified and as directed. Make: Century LED Ltd cat part no TWPP020C For rod and KCCF200 for Fitting battten/Surya Cat No SLETLDS18PALEXT for rod & SUB118T8LED for batten/ Wipro Cat No LL13-181-SESL for rod & W10921208 for batten or equivalent Model of Makes specified in PS here-in-after.
Supply and fixing LED batten mirror light 10 Watt extruded aluminium body, PC diffuser and inbuilt driver, prewired with electronic driver and diffuser and all accessories fitted on wall / ceiling including connecting up with three core twisted flexible copper conductor cable of suitable size including taking down the old light fitting any type complete all as specified and as directed. (Make : Century/Surya/Philips/Wipro/Havells)
Supply and fix LED bulk head light fitting 12 Watt IP 65 protection with inbuilt driver prewired to be fixed on wall/ ceiling complete with all accessories and including connecting up with twin core twisted flexible copper conductor cable of suitable size including taking out old unserviceable fitting any type complete all as specified and directed. (Make : Century/Surya/Philips/Wipro/Havells)
Supply and fix LED STREET light/Building security light 45 Watt die cast aluminium housing with IP-65 protection and surface mounting device LED 45 Watt with lens with inbuilt driver prewired and SPD 5 KV building security luminaire including all fixing arrangement required to fixed on pole/ wall with suitable size of GI bracket including suitable size of fixing items such as clamps, nut bolts and washer of suitable size with connection complete including taking down old light fitting any type complete all as specified and directed. Make - Century LED Ltd Cat part No. - SPSP045C / Wipro Cat no LR13611xxx57xx / Philips/Surya cat no SLE UL 45WLXN or equivalent Model of Makes specified in PS here-in-after.
Material and labour for sub-main wiring with two run of FRLS PVC insulated unshethed single core multi-stranded copper conductor of size 1.5 sqmm and one run of 1.5 sqmm copper conductor as continuity earth wire drawn in and including PVC casing caping / PVC conduit medium duty of suitable size but not less than 20 mm dia on wall / floor etc, including PVC fittings such as bends Tee and boxes including taking down old unserviceable sub main wiring all as specified and directed (Note : (i) Three run of 1.5 sqmm wire one run of PVC conduit shall be measured and paid as one unit. (ii) Cost of wall cutting if any for laying of wire and also making good surfaces are deemed to be included in unit rate).
Material and labour for sub-main wiring with two run of FRLS PVC insulated unshethed single core multi-stranded copper conductor of size 2.5 sqmm and one run of 2.5 sqmm copper conductor as continuity earth wire drawn in and including PVC casing caping / PVC conduit medium duty of suitable size but not less than 20 mm dia on wall / floor etc, including PVC fittings such as bends Tee and boxes including taking down old unserviceable sub main wiring all as specified and directed (Note : (i) Three run of 2.5 sqmm wire one run of PVC conduit shall be measured and paid as one unit. (ii) Cost of wall cutting if any for laying of wire and also making good surfaces are deemed to be included in unit rate).
Matetial and labour for sub-main wiring with two run of FRLS PVC insulated unshethed single core multi-stranded copper conductor of size 4 sqmm and one run of 4 sqmm copper conductor as continuity earth wire drawn in and including PVC casing caping / PVC conduit medium duty of suitable size but not less than 20 mm dia on wall / floor etc, including PVC fittings such as bends Tee and boxes including taking down old unserviceable sub main wiring of any size in steel/ PVC rigid conduit complete all as specified and directed (Note : (i) Three run of 4 sqmm wire one run of PVC conduit shall be measured and paid as one unit. (ii) Cost of wall cutting if any for laying of wire and also making good surfaces are deemed to be included in unit rate).
Supply and fixing TPN DB 4 way double door horizontal type 415 volts suitable for four pole MCB TPN as incomer including make good of damaged surface/wall including re-connection with existing earth wire to DB incuding taking out the old unserviceable one complete all as specified and as directed. (Make : C&S/Indoasian/Havells/L&T/Legrand)
Supply and fix powder coated sheet steel enclosure fitted with busbar, DIN channel, neutral link & earth link superline SPN DB (Double door) 8 way, 240 volts including taking down the old unserviceable DB complete all as specified as directed. (Make : C&S/Indoasian/Havells/L&T/Legrand)
Supply and fix powder coated sheet steel enclosure fitted with busbar, DIN channel, neutral link & earth link superline SPN DB (Double door) 4 way, 240 volts including taking down the old unserviceable DB complete all as specified as directed. (Make : C&S/Indoasian/Havells/L&T/Legrand)
Supply and fix metal DP enclosure with DIN rail channel suitable for mounting MCB SPN 240 volts including taking down the old enclosure and connection complete all as specified as directed. (Make : C&S/Indoasian/Havells/L&T/Legrand)
Supply and fix metal FP enclosure with DIN rail channel suitable for mounting MCB TPN 240 volts including taking down the old enlcosure and connection complete all as specified as directed. (Make : C&S/Indoasian/Havells/L&T/Legrand)
Supply and fix MCB TPN 63 amps, 415 volts, 'C' series with all incoming / outgoing connections with proper size of lugs complete all as specified as directed. (Make : C&S/Indoasian/Havells/L&T/Legrand)
Supply and fix MCB TPN 40 Amps, 415 volts, 'C' series with all incoming / outgoing connections with proper size of lugs complete all as specified as directed. (Make : C&S/Indoasian/Havells/L&T/Legrand)
Supply and fix MCB TPN 32 Amps, 415 volts, 'C' series with all incoming / outgoing connections with proper size of lugs complete all as specified as directed. (Make : C&S/Indoasian/Havells/L&T/Legrand)
Supply and fix MCB single pole & neutral 40 to 63 Amps, 240 volts, 'C' series with all incoming / outgoing connections with proper size of lugs complete all as specified as directed. (Make : C&S/Indoasian/Havells/L&T/Legrand)
Supply and fix MCB single pole & neutral 32 amps, 240 volts, 'C' series with all incoming / outgoing connections with proper size of lugs complete all as specified as directed. (Make : C&S/Indoasian/Havells/L&T/Legrand)
Supply and fix MCB single pole 6 to 32 amps, 240 volts, 10 KA, 'C' series with all incoming / outgoing connections with proper size of aluminium lugs complete all as specified as directed. (Make : C&S/Indoasian/Havells/L&T/Legrand)
Supply and fix Blanking plate for MCB DB complete all as specified as directed.
Supply and fix 3 pin plug top 16 Amps for geyser 25/35/50 Ltrs complete all as specified and directed. (Make : C&S/Indoasian/Havells/L&T/Legrand)
Supply and fix 3 pin plug top 6 Amps for air circulator wall mounted fan/ floor mounted pedestal fans complete all as specified and directed. (Make : C&S/Indoasian/Havells/L&T/Legrand)
Supplying, laying, commissioning and testing XLPE insulated PVC sheathed armoured heavy duty electric cable of size 16 Sqmm 2 core with aluminium conductor for working voltage upto and including 1100 volts, ISI marked to be laid on wall, fixed to pole, wall/roof complete with cable end, lugs including required size of aluminium thimble for making connection including taking down old unserviceable cable of any type and size completed all as specified and directed.
Supplying, laying, commissioning and testing XLPE insulated PVC sheathed armoured heavy duty electric cable of size 16 Sqmm 4 core with aluminium conductor for working voltage upto and including 1100 volts, ISI marked to be laid on wall, fixed to pole, wall/roof complete with cable end, lugs including required size of aluminium thimble for making connection including taking down old unserviceable cable of any type and size completed all as specified and directed.
Materials and labour for earthing complete with galvanized earth plate electrode 600 x 600 x 6.0 mm thick, buried directly in ground (earth pit not less than 2.25 m deep below normal ground level ) with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanized iron earth lead wire 4.0 mm dia length upto 7.5 mtr by means of bolts, nuts, check nuts and washers of galvanized iron or steel, earth lead wire protected by and including 15mm dia GI pipe (light grade) not exc 7.5 mtr, alternate layers of charcoal and salt, including 20 mm bore GI tubing for watering to earth electrode, earth lead connected to test point/ distribution panel /feeder pillar etc as directed including necessary earth work, concrete pit with PCC (1:3:6) type C1, pre cast RCC(1:1:5:3) type A1 cover slab duly reinforced with 8 mm dia TMT bar 150mm c/c both way and two numbers lifting handle made of TMT bar and set in cement mortar (1:4), funnel, wire mesh, all as shown in electrical plate No 3 of SSR part-1 and testing on completion including taking out old earthing complete all as specified and directed.
S&F Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire including taking out old wire complete all as specified and directed.
S&F GI pipe 15 mm bore 'light grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors including taking out old pipe complete all as specified and directed.
Taking down carefully storage type water heater (Geyser ) of any make of capacity 25/35/50 Ltrs after removing all electrical and water connection from installed position at different locations,dismantling the geyser into parts for inspection.Checking /testing of all parts/accessories like appratus plate,heating element,thermostat switch,neon lamp, water tank,safety valve, spacer ring, rubber gasket,nut-bolts,inspection plate, bottom& top cover etc and complete,de-scaling of water tank and brazing the same to make it leak proof complete inclduing replacement of unserviceable spare parts and re-installation, making electric and water connections and testing complete all as specified and directed. Note : (a) Old unserviceable parts required for replacement shall be measured & paid separately all as specified and directed. (b) Painting if required shall be measured and paid separately all as specified and directed.
Supply and fixing Apparatus assembly plate (8/9 hole) with geyser coil for Geyser of 25 /35 /50 Ltrs capacity, as per existing type and model complete all as specified and directed.
Supply and fixing thermostat straight stem type as per existing model complete all as specified and directed.
Supply and fixing heating element 1500 watt suitable for Geyser of 25 Litres capacity as per existing type and model complete all as specified and directed.
Supply and fixing heating element 2000 watt Gyser of 25/35/50 Ltrs capacity as per existing type and model complete all as specified and directed.
Supply and fixing Indicating lamp LED type,as per existing model (Red/Green) (square/round) batten type for Geyser of 25/50 Litres capacity complete all as specified and directed.
Supply and fixing 15 mm dia 450 mm long PVC flexible cold water inlet pipe nut type complete all as directed. Make: Prayag /suprimo or equivalent as approved GE.
Supply and fixing 15 mm dia 450 mm long hot water pipe (inlet wire mess and nut type) water inlet pipe complete all as specified and directed.
Supply & fixing 15mm bore stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed fancy type, chromium plated after taking down old one complete all as specified & directed.
Supply & connecting PVC insulated and overall PVC sheathed and flexible multistranded copper conductor cable 3 core of size 2.5 sqmm for 25/35/50 Ltrs capacity Geyser after taking down old one complete all as specified and directed.
S&F Electronic constant current Driver for LED fitting of size 18-20 watt, 240 volts,, 50 Hz of any type as per existing fitting complete all as specified and directed.
S&F Electronic constant current Driver for LED fitting of size 36-45 watt, 240 volts, 50 Hz, of any type as per existing fittings complete all as specified and directed.
Taking down carefully the ceiling fans 1200 / 1400 mm /exhaust fans/ air circulators/wall mounted fans/pedestal fans of any make/model any type and size from existing position of high rise shed/ bldg from their existing position after disconnecting blades including other accessories / components, cleaning / greasing including rewinding burnout/worn-out winding and reassembling all components by provision of new and old serviceable components and fixing / hanging in existing position after repair/painting work complete all as specified and directed. Note: (i) The spares shall be measured and paid separately under supply only items. The labour element involved for replacing the spares shall be deemed to be included in the unit rate quoted. (ii) Painting shall be measured & paid separately. (iii) Rewinding burnout/worn-out winding shall be measured & paid separately
All as per item No. 178 above but for Exhaust Fan metal body of size 230/ 300 mm complete all as specified and directed.
All as per item No. 178 above but for Exhaust Fan metal body of size 450/600 mm complete all as specified and directed.
All as per item No. 178 above but for Padestal Fan heavy duty metal body of size 450/600 mm complete all as specified and directed.
Supply only GM Bush for ceiling/ exhaust/ wall mounted/ pedestal fan complete all as specified & directed.
Supply only ball bearing for ceiling/ exhaust/ wall mounted/ pedestal fan (Bearing No. 6201) complete all as specified & directed. Make TATA/SKF/NBC
Supply only ball bearing for ceiling/ exhaust/ wall mounted/ pedestal fan (Bearing No. 6202) complete all as specified & directed. Make TATA/SKF/NBC
Supply only ball bearing for ceiling/ exhaust/ wall mounted/ pedestal fan (Bearing No. 6203) complete all as specified & directed. Make TATA/SKF/NBC
Supply only capacitor of 2.0 mfd capacitance complete all as specified & directed.
Supply only capacitor of 2.50 mfd capacitance complete all as specified & directed.
Supply only capacitor of 3.15 mfd capacitance complete all as specified & directed.
Supply only capacitor of 4.0 mfd capacitance complete all as specified & directed.
Supply & fixing MS sheet folded type louver for 230/300 mm sweep exhaust taking down old louver complete all as specified & directed.
Supply & fixing MS sheet folded type louver for 450 mm sweep exhaust taking down old louver complete all as specified & directed.
Material & labour for painting of ceiling fans 1200 / 1400 mm including blades/down rods/ canopy/stand, casing/ cage and all accessories after thoroughly rubbing /cleaning old rusted spot and paint by soft wire brush with one coats of synthetic enamel paint of existing tint and marking MES No. complete all as specified and directed.
All as per item No. 192 above but for Exhaust Fan metal body of size 230/ 300 mm complete all as specified and directed.
All as per item No. 192 above but for Exhaust Fan metal body of size 450/600 mm complete all as specified and directed.
Material and labour for rewinding of ceiling fans armature of 1200 mm/1400 mm sweep any make/ model with new super enamelled high grade copper wire of existing gauge with number of turns including provision of proper insulating materials and heat varnishing and testing complete after replacement of burnout winding complete all as specified and directed.
Material and labour for rewinding of exhaust fan 230mm/ 300mm sweep any make/ model, single phase, 230 volts with new super enamelled high grade copper wire of existing gauge with number of turns including provision of proper insulating materials and heat varnishing and testing complete after replacement of burnout winding complete all as specified and directed.
Material and labour for rewinding of exhaust fan 450/600mm sweep any make/ model, single phase, 230 volts with new super enamelled high grade copper wire of existing gauge with number of turns including provision of proper insulating materials and heat varnishing and testing complete after replacement of burnout winding complete all as specified and directed.
Supply and fixing in replacement of fan blades for exhaust fan 230/ 300 mm sweep any make/model (as per existing sample) complete all as specified and directed.
Supply and fix exhaust fan made of sturdy engineering plastic complete with louvers shutters 250 mm sweep, 230V, AC 50 Hz, copper winding and mounting accessories complete all as specified and directed.
Supply and fix sheet steel enclosure fitted with plug & socket metal clad AC box with MCB SP 20A including insulated neutral link, adjustable DIN rail channel and connecting links complete after taking down the old socket board and connection complete all as specified as directed.
CHOWDHURY SMALL INDUSTRIES
B G Trading Co.
Odessa Engineering Corporation
MASTER BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .