Loading…
Loading…
Tender Value
₹50 L
EMD Value
₹40,000
Closing Date
29 Jul 2026, 6:00 pm
SURAT IND DIVISION
A R C work for laying, testing and commissioning of 11/22 KV underground XLPE cable under various scheme i n Pramukhpark Ind S/dn under jurisdiction of Pandesara Division. Wire Free Network and if required any other Scheme.
320907
T-10 /DGVCLSDPND/0157/06/2026 Approved Date: 04-07-2026 05:52
Open
Electrical
Surat
6 documents required · 6 mandatory
₹1,180
SURAT IND DIVISION
₹40,000
4 Jul 2026
4 Jul 2026
4 Jul 2026
29 Jul 2026
4 Jul 2026
3 Estimated Cost Rs.
Tender Fees (Non Refundable) with Rs. 1180 .00 (As per Clause mentioned
18% GST in Instruction to Bidders Clause No. 9)
Rs. 40,000.00 (As per Clause mentioned
5 Earnest Money Deposit in Instruction to Bidders Clause No.
10) Exemption in EMD will not allow.
Date & Place of Pre-Bid Meeting (If
Date : 29.07.2026 on
Last Date of On Line (E-Tendering)
submission of Tender
Time : Up to 18.00 Hrs.
Date : 29.07.2026 on
Last Date of submission of Tender
Fee & EMD (Through online Mode)
Time : Up to 18.00 Hrs.
Date : 30.07.2026 on
Date of opening of Preliminary Stage
(Tender Fee & EMD Online )
Time : Up to 10.30 Hrs.
Date : 30.07.2026 on
Tentative Date of opening of
Time : Up to 11.00 Hrs.
Date : 31.07.2026 on
Tentative Date of On line Opening of
Time : Up to 16.00 Hrs.
12 Validity of Tender Maximum period of 180 Days
13 Work Completion Period / Time Limit 24 Months (As per quantum of work)
DGVCL GSTIN No. is 24AABCD8912C1Z3.
Every Bidder has to inform their GSTIN No. at the time of payment of applicable fees..
a. Interested Bidders can view these tender documents online. The bidders who are interested in bidding in these tenders can
download tender documents from website https://tender.nprocure.com and www.DGVCL.com
Bidders, who wish to participate in this tender, will have to register on https://tender.nprocure.com Further, Bidders who wish to
participate in online tenders will have to procure Digital Certificate as per Information Technology Act-2000 using which they can
sign, their electronic bids. Bidders can procure the same from GNFC, Ahmedabad, who are licensed certifying authority by
Government of India and they will assist them in procuring the same as below mentioned address. Bidders who already have a valid
Digital Certificate need not procure a new Digital Certificate.
File No: DGVCLSDPND/OTH/e-file/4516/2026/1418/Billing
Approved By: Executive Engineer,Technical,DGVCLDSRTI
Letter No: DGVCLSDPND/0157/06/2026 Approved Date: 04-07-2026 05:52
n) Code solutions-A PANDESARA IND DIVISION of GNFC Ltd.,
301, GNFC Info tower, S.G. Road, Bodakdev.
Ahmedabad – 380054 (Gujarat)
Email: [email protected]
b. However, no physical documents required if payment of tender Fee and EMD made through, RTGS & NEFT(upload
receipt online on https://tender.nprocure.com ).
c. Further bidders are requested to submit price bid (Schedule: B) on-line only and not to submit the price bid in physical form.
This is mandatory. If price bid is submitted in physical form, such offer shall be out rightly rejected.
d. It is mandatory for all the bidders to submit their tender documents with all relevant documents as desired in participation of
this bidthrough on-line (e-tendering) in schedule time. If tender documents with all relevant documents submitted in physical
form, in that case the online submitted documents shall be considered.
e. Bidders should be in touch with websites https://nprocure.com&www.dgvcl.com for intimation regarding
revision/corrigendum/Amendment in tender till due date of online submission and thereafter. No separate information
shall be sent in this regards and also not publish in newspaper. The directives and amendments issued
by DGVCL will have superseding effect to relevant section and specifications.
f. Any technical questions, information & clarification that may be required pertaining to this inquiry should be referred to
Executive Engineer PANDESARA DIVISION Office, “Dakshin Gujarat Vij Company Limited”
g. DGVCL reserves the right to reject any OR all tenders without assigning any reasons thereof.
h. Bank Details:
Bank Name: Bank of Baroda
Account Name: DGVCL IND DIV PANDESARA
Account Number:
IFSC Code: BARB0INDPAN
[Note-It is compulsory to mention Tender ID and Bidder name in reference for transaction confirmation
purpose of Tender Fee & EMD. Received online]
If payment make through RTGS/NEFT to the above account then share your UTR No. To the E-Mail ID:
[email protected] Also quote your name & amount paid.
You have to compulsory inform to detail regarding Online payment of tender fee and EMD at This office on E-Mail ID:([email protected])
Executive Engineer (O&M)
File No: DGVCLSDPND/OTH/e-file/4516/2026/1418/Billing
Approved By: Executive Engineer,Technical,DGVCLDSRTI
Letter No: DGVCLSDPND/0157/06/2026 Approved Date: 04-07-2026 05:52
DGVCL, PANDESARA DIVISION
Download Tender Documents in (PDF Format) which consists of:
Instructions to Bidder
General Conditions of Contract
Schedule “B” indicating the quantities, rates & items, drawing if any.
Appendix and Annexure
Technical Specifications & GTP’s
To view the PDF file please use “Acrobat Reader” software which can be downloaded from “Adobe
Schedule B ( Annexure-A)
CAPITAL WORK LABOUR RATES FOR FY 2024-25 (WITHOUT GST)
Sub:- Supply, laying, testing and commissioning of 11KV /22 KV UG cable (XLPE cable will be supplied by
DGVCL) with cable termination and straight through joints kits (to be supplied by contractor) for laying
Underground Cable in all Schemes at Pramukh Park Ind. Sub Division under Pandesara Division. Wire Free
Network and if required any other Scheme.
Item Code Item Unit QTY FY 2024-25
Labour charge for excavation of cable trench of 400mm width x
1200mm depth, in any type of soil for laying of cable of size up to
mm2 (For additional cable 200 mm additional width shall be
considered i.e. half trench length is to be considered)
Labour charge for excavation of cable trench of 600mm width x
1200mm depth, in any type of soil for laying of cable of size up to
mm2 (For additional cable 200 mm additional width shall be
considered i.e. half trench length is to be considered)
Labour charge for excavation of cable trench of 400mm width x
1500mm depth, in any type of soil for laying of cable of size up to
3 9925000003 mm2 (For additional cable 200 mm additional width shall be Meter
considered i.e. half trench length is to be considered)
Labour charge for laying of 11kV / 22 kV XLPE Cable of size up to
mm2 & preparation of sand layer 100mm thick, in the cable trench &
covering the cable with 150 mm dia (Inner), thickness 25 mm,
meter long RCC half round muffs and providing and fixing of 4inch
width yellow colour polyethylene tape with printing "CAUTION
ELECTRIC CABLE BELOW" at 0.75 m depth from ground surface
after laying cable in trench. This will provide indication that electric
cable is passing underground so as to protect cable from mechnical
injuries, refilling the same, as per Instruction of Engineer in Charge
File No: DGVCLSDPND/OTH/e-file/4516/2026/1418/Billing
Approved By: Executive Engineer,Technical,DGVCLDSRTI
Letter No: DGVCLSDPND/0157/06/2026 Approved Date: 04-07-2026 05:52
Labour charge for horizontal drilling using Auger machine without
damage to surface road at max 2.0 mtrs depth & putting of
kg/cm2 , class-4,Green color, 110mm O.D. , 8.5mm thickness
H.D.P.E. pipe confirms to IS 4984-1987(3rd revision) and BIS
certification and laying of 11KV/22KV XLPE cable of size up to
5 9925000005 mm2 in HDPE pipe, as per Site Condition (excluding cost of pipe). The Meter
detail map obtained from HDD machine and excell sheet(hard and soft
copy) indicating the respective depth and distance from adjacent
landmark for each segment for HDD is must required to be submitted.
HDD to be carried out at depth 1.5 mtrs to 2.0 mtrs as per site
conditions and as per instruction of EIC.
Labour charge for horizontal drilling manually without damage to
surface road at max 2.0 mtrs depth & putting of 6.11 kg/cm2 , class-
4,Green color, 110mm O.D. , 8.5mm thickness H.D.P.E. pipe confirms
to IS 4984-1987(3rd revision) and BIS certification and laying of
11KV/22KV XLPE cable of size up to 240 mm2 size, as per Site
Condition (excluding cost of pipe). The detail map and excell
sheet(hard and soft copy) indicating the respective depth and distance
from adjacent landmark for each segment of cable to be submitted.
Drilling to be carried out at depth Minimum 1.2 mtrs to 2.0 mtrs as per
site conditions as per instruction of EIC.
Supply of 6.11kg/cm2 , class-4,Green color, 110mm O.D. , 8.5 mm
thickness H.D.P.E. pipe confirms to IS 4984 and BIS certification
for laying of underground 11KV / 22KV XLPE cable up to 240 mm2
Labour work for RCC concreting on disputed location and repairing of
damage portion of road crossing for the work carried out for roads
crossing as well as concreting & muffing of ploes including all
materials (1:2:4)
Providing & fixing concrete stone route marker of 300 mm width x
mm thick x 650 mm height embedded in earth at least 300 mm below
& 350 mm above ground level respectively at distance approx
meters along the length of cable. The RCC concreting (1:2:4)(all
necessary maeterials will be in bidder's scope) of route marker is to be
carried out 300 mm width x 150 mm thick x 300 mm below ground
level as per instruction of EIC. The route marker should be with name
of company with approved yellow colour-DGVCL. The distance from
marker to cable and cable depth with feeder name etc., marked with
arrow sign is to be painted on it.The route marker is to be fixed at
location near to any fixed permanent location (not necessary to fix
exact on top of cable) as per instruction of EIC.
Erection of D.P. (double pole) structure using 9 / 11 Mtr. RSJ pole with
cable connection arrangement along with fitting of necessary
fabrication for 11KV cable including excavation of pit & refilling of earth
as per instruction of EIC. (Exclusive of concreting & muffing of poles)
Erection of Single pole structure using 9 / 11 Mtr RSJ pole with cable
connection arrangement along with fitting ofnecessary fabrication for
11KV/22 KV cable including excavation of pit & refilling of earth as per
instruction of EIC. (Exclusive of concreting & muffing of poles)
Erection of D.P. (double pole) structure using 8.0 Mtr. PSC pole with
cable connection arrangement along with fitting of necessary
fabrication for 11KV cable including excavation of pit & refilling of earth
as per instruction of EIC. (Exclusive of concreting & muffing of poles)
Erection of Single pole structure using 8.0 Mtr PSC pole with cable
connection arrangement along with fitting ofnecessary fabrication for
11KV/22 KV cable including excavation of pit & refilling of earth as per
instruction of EIC. (Exclusive of concreting & muffing of poles)
Labour charge for erecting of 11kV / 22 kV XLPE cable of size up to
240 mm2 on DP Structure with fixing of 02 Nos polymer cleats on top
and middle part.Polymer cleats, nut bolts etc. fixing material to be
provided by contractor.
File No: DGVCLSDPND/OTH/e-file/4516/2026/1418/Billing
Approved By: Executive Engineer,Technical,DGVCLDSRTI
Letter No: DGVCLSDPND/0157/06/2026 Approved Date: 04-07-2026 05:52
Providing & fixing of 6.11kg/cm2 , class-4,Green color, 110mm O.D.
8.5mm thickness H.D.P.E. pipe confirms to IS 4984 and BIS
certification on the erected DP structure for the mechanical protection
of cable by inserting the cable inside HDPE pipe. The HDPE pipe shall
be erected in such a way that 300mm shall be below the ground level
and the rest 2700 mm shall be supported on the DP Structure with
No Polymer cleat.All materials including polymer cleat and Nut bolt to
be provided by contractor.
Providing and fixing of pipe type earthing from 80 mm dia class-B GI
pipe with pit to be filled with salt & coke and construction of chamber
16 9925000016 as per DGVCL Drg. No. dg /100 for DP and cable. The earthing pit No.
should be joined with cable by G.I. strip of size 1” width & 2 mm thick.
All material GI pipe, Coke, Salt etc will be supplied by bidder.
Supply & fixing of heat shrink type end terminations (outdoor) for
17 9925000017 upto 11kV 3C x 185 mm2 size XLPE cable as per DGVCL technical No.
Supply & fixing of heat & shrinkable end terminations (outdoor) for
18 9925000018 upto 22 kV 3C x 185 mm2 size XLPE cable as per DGVCL technical No.
Supply & fixing of heat shrink type end terminations (indoor) for upto
19 9925000019 11kV 3C x 185 mm2 size XLPE cable as per DGVCL technical No.
Supply & fixing of heat & shrinkable end terminations (indoor) for upto
20 9925000020 22 kV 3C x 185 mm2 size XLPE cable as per DGVCL technical No.
21 9925000021 Supply & fixing of heat shrinkable straight through joint for upto 11kV No.
3C x 185 mm2 size XLPE cableas per DGVCL technical specification.
Supply & fixing of heat shrinkable straight through joint type for upto
22 9925000022 22kV 3C x 185 mm2 size XLPE cable as per DGVCL technical No.
Labour charge for excavation of 2100mm long x 1200mm wide x
mm deep joint pits for installation of 11kV / 22kV Straight through
23 9925000023 joints as per instruction of engineer-in-charge & covering the cable No.
with 150 mm dia (Outer), thickness 25 mm, 1.0 meter long RCC half
round muffs & refilling same as per instruction of EIC .
Providing and fixing of insulating bus bar, made from 11KV/22KV
XLPE cable after removal of semi conducting layer and applying of
PVC heat shrinkable anti-tracking core insulating tubing (1.1KV), on
both end terminal using Aluminium long barrel heavy duty up to 240 sq
24 9925000024 mm lugs, Aluminium bus connector. Taping with PG- clamp for bus No.
conductor as per drawing and as per instruction of EIC. The
Alluminium lugs and PG clamp shall be covered with 11KV/22KV HT
insulating tapes.(11KV/22KV XLPE cable will be in scope of DGVCL
while all other materials will be in bidder's scope)
Testing of cable at various points and commissioning the feeder
25 9925000025 as per instruction of engineer-in-charge.Test result shall be No.
submitted by contractor with bill.
Preparation and submission of 6 (six) copies, of complete layout
26 9925000026 drawings with GIS mapping as per actual cable routing showing road Set
crossing, HDPE pipe sleeving, jointing locations, markers etc.
File No: DGVCLSDPND/OTH/e-file/4516/2026/1418/Billing
Approved By: Executive Engineer,Technical,DGVCLDSRTI
Letter No: DGVCLSDPND/0157/06/2026 Approved Date: 04-07-2026 05:52
Providing and fixing of Sign Board at junction point Made out of 2 mm
aluminium sheet size 750x300 mm (2.5 x 1ft) rectangle, as per design,
pre treated with phosphate process and acid etching coated with one
coat of epoxy primer and two coats of best quality paints, refloctrorised
with Hi-Intensity retro – reflective sheeting as per the latest and frame
27 9925000027 fabricated from suitable size iron angle. The Sign Board is to be fixed No.
on the base prepared from channel and bracing angles which is
grouted by means of cement concreting of 1:2:4 for size of 300 mm dia
x 800 mm height (500 mm to be grouted in ground). The details to be
displayed on sign board will be given by In-charge Engineer.
(a) Hi intensity Micro prismatic Grade
Providing and fixing of Sign Board (Danger Board) on Distribution
Transformer Centers
Made out of 2mm aluminium sheet size 300x300mm (1x1ft) as per
design, pre treated with phosphate process and acid etching coated
with one coat of epoxy primer and two coats of best quality paints,
refloctrorised with Hi-Intensity retro-reflective sheeting as per the latest
and frame fabricated from suitable size iron angle. The Sign Board
(Danger Board is to be fixed at the location as per instruction of In-
charge Engineer.
(a) Hi intensity Micro prismatic Grade
Providing & fixing of aluminium tag of size 250 mm (L) x 75 mm (W)
from 3 mm aluminium sheet along with 1.0 mm dia aluminium binding
wire for fixing of aluminium tag near end termination joint at DP
structure for identifyng the cable. The details of feeder i.e. 11 / 22 KV
with feeder name shound be punched on the tag by letter punch of
size 16 mm as per instruction of In-charge Engineer.
Supply & fixing of heat shrink type end terminations (outdoor) for 11kV
3C x 240 mm2 size XLPE cable as per DGVCL technical specification
Supply & fixing of heat & shrinkable end terminations (outdoor) for
31 9925000031 kV 3C x 240 mm2 size XLPE cable as per DGVCL technical No.
Supply & fixing of heat shrink type end terminations (indoor) for 11kV
3C x 240 mm2 size XLPE cable as per DGVCL technical specification)
Supply & fixing of heat & shrinkable end terminations (indoor) for 22 kV
3C x 240 mm2 size XLPE cable as per DGVCL technical specification
Supply & fixing of heat shrinkable straight through joint for 11kV 3C x
240 mm2 size XLPE cableas per DGVCL technical specification.
Supply & fixing of heat shrinkable straight through joint type for 22kV
3C x 240 mm2 size XLPE cable as per DGVCL technical specification
Installation, Testing and commissioning of 11 KV,630 A SCADA
Compatible, RRL type- 3 Way RMU including Two numbers of
earthings as per Drawing (material is in bidder's scope) and as per
DGVCL Technical specification.
Installation, Testing and commissioning of 11 KV,630 A SCADA
Compatible, RRLL type- 4 Way RMU including Two numbers of
earthings as per Drawing (material is in bidder's scope) and as per
DGVCL Technical specification.
Installation, Testing and commissioning of 22KV,630 A SCADA
Compatible, RRL type-3 Way, RMU including Two numbers of
earthings as per Drawing (material is in bidder's scope) and as per
DGVCL Technical specification.
Installation, Testing and commissioning of 22KV,630 A SCADA
Compatible, RRLL type-4 Way, RMU including Two numbers of
earthings as per Drawing (material is in bidder's scope) and as per
DGVCL Technical specification.
File No: DGVCLSDPND/OTH/e-file/4516/2026/1418/Billing
Approved By: Executive Engineer,Technical,DGVCLDSRTI
Letter No: DGVCLSDPND/0157/06/2026 Approved Date: 04-07-2026 05:52
Construction of plinth for 11KV, RRL type- 3 Way (i.e Two
numbers of Isolator & One number of Breaker) Ring Main Unit as
per DGVCL's technical specification mentioned in drawing no:
Drg. 11kv-01. All required material will be supplied by contractor.
Construction of plinth for 11KV, RRLL type- 4 Way (i.e Two
numbers of Isolator & Two number of Breaker)Ring Main Unit as
41 9925000043 per DGVCL's technical specification mentioned in drawing No.
no:Drg. 11kv-02.All required material will be supplied by
Construction of plinth for 22KV, RRL type- 3 Way (i.e Two
numbers of Isolator & One number of Breaker) Ring Main Unit as
per DGVCL's technical specification mentioned in drawing no:
Drg. 22kv-01. All required material will be supplied by contractor.
Construction of plinth for 22KV, RRLL type- 4 Way (i.e Two
numbers of Isolator & Two number of Breaker)Ring Main Unit as
43 9925000045 per DGVCL's technical specification mentioned in drawing No.
no:Drg. 22kv-02.All required material will be supplied by
Modifications e.g.Providing and fixing of Terminal protectors i.e. Re-
use able boot (HT Side 11/22KV, LT Side 1.1KV) including 11/22 KV
insulating taps and L.T.(1.1 KV) insulating taps ,Busbar, Tapping from
Bus Bar (11/22 KV XLPE cable) through P.G. Clamp for H.T. Jumper
to D.O. Fuse to bushings of Transformer Center, providing & Fixing of
jumper and providing & fixing of Heat Shrinkable Anti Tracking Core
Insulating Tubing (Insulation Level 11/22 KV) in H.T. jumper
Clamping arrangement of cable support frame on both side of existing
Over Head type Distribution Transformer to utilize in Under Ground
cable network as per drawing & as per instruction of Engineer
incharge. All live parts i.e. PG-Clamp, connections of D.O.fuses, HT
bushings etc . shall be covered with fixinng of 11/22 KV HT insulating
tapes. ( 11/22 KV XLPE cable will be in scope of DGVCL while all
other materials will be in bidder's scope ) .
Laying of any size of 11/ 22 KV XLPE /PILC Cable in redaymade
trench or in open space
46 9925000060 Labour charges for Lying of O/H XLPE cable pole to pole KM
Supply of 150 mm dia (Inner), thickness 25 mm, 1.0 meter long RCC
half round pipe
Rs Fifty Lacks Only TOTAL
File No: DGVCLSDPND/OTH/e-file/4516/2026/1418/Billing
Approved By: Executive Engineer,Technical,DGVCLDSRTI
Letter No: DGVCLSDPND/0157/06/2026 Approved Date: 04-07-2026 05:52
Note: 1.DGVCL will provide key material like M.S. materials,ABC/Bare
conductors,PSC/RSJ Poles,Insulators,Fabricated
materials etc. to the contractor.
2.All fabricated items shall be fabricated as per DGVCL approved
drawing and by welding rods confirming to the relevent ISI
specification and as directed by Engineer in charge.
3.Necessary electricity connection for fabrication items shall be
provided by DGVCL on payment of required charge for connection &
electricity bill of the same shall be paid by the agency.
4.All the rates are inclusive of PF & Exclusive of GST applicable time
5.All steel material are to be painted as below:
(a) Scrubbing of rusted surface properly before applying the paints on
to the RSJ poles & steel fabricated materials of RSJ/PSC poles is
(b) Two coats of approved ISI mark red oxide (primer) is to be properly
painted for the RSJ poles & steel fabricated materials of RSJ/PSC
(c) Two coats of approved ISI mark silver paint (i.e. triple mangoes or
equivalent quality silver paint) is to be properly painted on to the RSJ
poles & steel fabricated materials of RSJ/PSC poles.
EXECUTIVE ENGINEER
DGVCL, PANDESARA
DIVISION, SURAT
File No: DGVCLSDPND/OTH/e-file/4516/2026/1418/Billing
Approved By: Executive Engineer,Technical,DGVCLDSRTI
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
T-10 FINAL Bid Document.pdf
T-10 Annexure 2 and 3.pdf
T-10 Annexure1 PIC earthing.png
PNG
T-10 Detail Technical Specification.pdf
NOTICE AND SCHB.pdf
Download all tender documents and submit your bid