Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.8 CrAccepted-AOC | ₹36.8 Cr | L1 | Accepted-AOC ACCEPTED BEING LOWEST AND QUOTED AMOUNT FOUND REASONABLE |
| 2 | L2₹38.7 CrRejected-Finance | ₹38.7 Cr | L2 | Rejected-Finance Rejected being not lowest. |
| 3 | L3₹43.6 CrRejected-Finance 4 195 38 PARAMESHWARA NILAYA MARAKADA KUNJATHBAIL DAKSHINA KANNADA KARNATAKA 575014 UDYAM KR 11 0021217 | DAKSHINA KANNADA | KARNATAKA | 575014 | ₹43.6 Cr | L3 | Rejected-Finance Rejected being not lowest. |
| 4 | L4₹43.8 CrRejected-Finance | ₹43.8 Cr | L4 | Rejected-Finance Rejected being not lowest. |
Tender Value
₹35 Cr
EMD Value
₹15 L
Closing Date
27 Mar 2023, 6:00 pmClosed
CE NW Kochi
CHIEF ENGINEER NAVAL WORKS KOCHI MILITARY ENGINEER SERVICE NAVAL BASE POST KATARIBAGH KOCHI 682 004
SETTING UP OF MARRIED ACCN FOR SAILORS AS PART OF INFRASTRUCTURE AUGMENTATION AT INA EZHIMALA
2022_MES_562296_1
891003
Open Tender
Civil Works
900 days
EZHIMALA
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹3,000
Yes
GE (P) EZHIMALA
₹15 L
Yes
28 Apr 2023
10 Nov 2022
29 Mar 2023
11 Nov 2022
27 Mar 2023
13 Mar 2023
Amount
Total amount of Sch 'A' Part-I : (Buildings/ Structures )
Total amount of Sch 'A' Part-II : Excavation, earthwork, site clearance and site development)
Total amount of Sch 'A' Part-III : (Internal water supply)
Total amount of Sch 'A' Part-IV : (Internal Electric Supply)
Total amount of Sch 'A' Part- V : (External Water Supply )
Total amount of Sch 'A' Part-VI : (External Electric Supply)
Total amount of Sch 'A' Part-VII : (Hot Water Supply)
Total amount of Sch 'A' Part-VIII : (Lightning Protection)
Total amount of Sch 'A' Part-IX : Fire Fighting and Fire Detection System
Total amount of Sch 'A' Part-X : (Area Drainage)
Total amount of Sch 'A' Part-XI : (Sewage Disposal)
Total amount of Sch 'A' Part-XII (Road/ Path/ Culvert )
Total amount of Sch 'A' Part-XIII : (Retaining Wall)
Total amount of Sch 'A' Part-XIV (DG Set)
Sch 'A' Part- XV : (Miscellaneous B/R & E/M Items (BOQ) (Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.)
Internal Electric Supply
Supply, fixing testing and commissioning of 4 feet 20 W LED surface mounted batten type luminaire, luminaire lumen output of 2000 lumens, luminaire efficacy>120 Im/W with an operating voltage range from 140 V – 270 V. The luminaire shall have a white CRCA housing with a poly carbonate diffuser to provide uniform light and a sleek design. The luminaire shall have a CCT of 6500 K, CRI>80, power factor>0.95, SDCM<5, THD<10% and 50,000 burning hours as per L70B50 criteria. The luminaire shall have flicker content <5% and shall have high and low cut off with auto restart feature. The luminaire shall be EMI/EMC compliant and shall have internal surge protection of 4 Kv. The luminaire shall have class – 1 Electrical Insulation, Class – B serviceability (The driver can be replaced at site level). The luminaire and driver shall be BIS approved with “R” number mentioned and test certificates of LM79 and LM80 reports from NABL accredited labs. Make Philips catalogue No. BN308C LED20S-6500 L120 PSU WH or equivalent in other makes as specified in the list of manufactures.
Supply, Fixing, Testing and commissioning of square type surface mounted light fitting 12 W LED, with extruded Aluminium heat sink, environmentally friendly, energy efficient prewired with lamp, AC, 230V, ISI marked, complete all as specified. Make: Philips Catalogue No. SM200C LED11S 6500 PSU OD WH or equivalent in other makes as specified in the list of manufactures complete all as specified manufactures.
Supply, fixing, testing and commissioning of 40 W, 4 feet LED fitting suitable for surface/ wall & conduit mounting with luminaire lumen output of 4000 lumens, luminaire efficiency >120Im/W with an operating voltage range from 140 V -270V. The luminaire shall have a white CRCA housing with a poly carbonate diffuser to provide uniform light and a sleek design. The luminaire shall have a CCT of 6500 K, CRI>80, power factor>0.95, SDCM<5, THD<10% and 50,000 burning hour as per L70B50 criteria. The luminaire shall have flicker content <5% and shall have high and low cut off with auto restart feature. The luminaire shall be EMI/EMC compliant and shall have a integral surge protection of 4 KV, The luminaire shall have Class-1 Electrical Insulation, Class-B serviceability (the driver can be replaced at site level). The luminaire driver shall be BIS approved with “R” number mentioned and test certificates of LM79 and LM80 reports from NABL accredited labs, ISI marked complete all as specified. Make : Philips catalogue No. BN308C LED40S-6500 L120 PSU WH or equivalent in ,other makes as specified in the list of manufactures
Supply, installation, testing and commissioning of 10W LED Wall mounted mirror light fitting, environmental friendly energy efficient prewired with amp, AC, 230V, ISI marked, complete all as specified. Make Philips Catalogue No. BN 021 LED12S 6500 PSU GR or equivalent in other makes as specified in the list of manufactures
Supply and fixing of light fittings 1x10W, 220V, AC decorative box type with driver, holder including LED light connecting up with three core flexible copper conductor cable of suitable size complete.
Supply and fixing modular foot light with LED 3W warm light, concealed in wall complete all as specified
Supply and fixing LED fitting 1 x 5W, 220V, AC , ceiling fitting with driver, holder including LED light connecting up with three core flexible copper conductor cable of suitable size complete.
Supply of LED street light luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with injection moulded polycarbonate material, delivering superior light output. Rated life burning Hrs 50000 hrs @ Lumen maintenance of 70 % maximum light intensity should be between 60 degrees to 70 degrees. CCT>5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire >IK08. Power Factor> 0.9 with mains, surge protection – Min 5KV along with over voltage /Over load, short circuit /miss wiring protection. Compatible for pole mounting with outer dia of 40 mm to 50mm. Universal voltage driver to operate wide voltage range from 100 V 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED light fixtures with W System power consumption. LED efficiency>130Im/w nominal CRI>75. Luminaire manufacturer should have in house facility accredited by NABL/CPRI & any government certified agency & design & development facility certified by ISO 9001:2008 . Housing with supplier word mark/name shall be engraved/embossing on the die cast housing/ Body part. Warranty of 2 years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/Lumileds/Osram make LED Source: - LED Street Light 25 Watts (Building External Light)
Supply and Fixing of 40mm dia class A G pipe bracket up to 1 Mtrs long bent at suitable angle and fixing to this bracket 25 watts LED street light fitting of all capacities to GI or CI or rail or RCC pole/ wall using suitable clamps, bolts and nuts and wiring using suitable capacity wires with all necessary accessories as required to complete.
Supply and Fixing of LED light fitting 1x10W, 220V,AC with driver, holder including LED light connecting up with three core flexible copper conductor cable of suitable size complete.
Supply and fixing of LED light fitting 1x10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete.
Supply installation, testing and commissioning of 1200 mm sweep, BEE 5 star rated ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 Nos blades, 30 cm long down rod, 2 Nos canopies shackle kit, safety rope copper winding power factor not less than 0.9, service Value (CMM/W)minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS: 374-2019), THD less than 10 %, without remote/ with electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts washers temperature rise=75 degree C(max), insulation resistance more than 2 mega ohm, suitable for 230 V, 50Hz, single phase AC supply, earthing etc. complete as required.
Supply, installation, testing and commissioning of heavy duty exhaust fan, electric single phase AC 230 Volts, Copper wound, 450 mm Sweep, 1400 RPM air delivery not less than 6120 cu.mtr/min connect to ceiling rose all as directed , complete all as specified Make: Almonard 18” or equivalent in other makes as specified in the list of manufacturers
Supply, Installation testing and commissioning of exhaust fan, electric single phase AC 230 Volts copper wound, self opening louvers complete 300 mm sweep, air delivery not less than 720 cu.mtrs/min connect to ceiling rose all as directed, complete all as specified. Make Crompton Greaves model Brisk Air 10” or equivalent in other makes as specified in the list of manufacturers
External Water Supply
Cutting Existing CI tubing 80mm Dia and inserting CI Tee 80X80X80mm , collar etc for taping including necessary Jointing and excavation / earth work and make good the surface all as specified and as directed (Each cut measured)
Supply and lay in trenches or as directed, centrifugally cast (spun) Ductile Iron pressure pipe with flanged ends of 80 mm bore and of any length of class K-9 of pressure class PN-1.6 suitable for double flanged joints with rubber gaskets etc all as specified and directed
Supply and fix cast iron foot valve of size 100 mm (4'') dia complete all as specified and directed
M & L for provision of masonry valve chamber of 0.6 x 0.6 x 0.6 m internal size including 100 mm thick PCC (1:5:10) type E2 foundation, brick working CM (1:6) plastering internal surfaces completely and external surfaces upto 150 mm belowground level, 15 mm thick in CM (1:4) 100MM THICK (1:3:6) TYPE C1 coping 80x50x6 mm angle iron, 6 mm thick MS plate cover comp;lete with'handle'locking arrangement inclouding painting steel and iron surfaces with two coats of synthetic enamel paint of tint as directed by Engineer-in-Charge over a coat red oxide complete all as shown on drawing No CE DD /TD/119 sheet 1/ 1. Note: The qouted rate inclusive of MS cover and locking arrrangements as per the drawings, necessary excavation and earth work, PCC, etc
M & L for provision of masonry valve chamber of 0.9 x 0.9 x 0.9 m internal size including 100 mm thick PCC (1:5:10) type E2 foundation, brick working CM (1:6) plastering internal suffaces completely and external surfaces upto 150 mm belowground level, 15 mm thick in CM (1:4) 100MM THICK (1:3:6) TYPE C1 coping 80x50x6 mm angle iron, 6 mm thick MS plate cover complete with'handle'locking arrangement inclouding painting steel and iron surfaces with two coats of synthetic enamel paint of tint as directed by Engineer-in-Charge over a coat red oxide complete all as shown on drawing No CE DD /TD/119 sheet 1/1. Note: The qouted rate inclusive of MS cover and locking arrrangements as per the drawings, necessary excavation and earth work, PCC, etc
Supply, installing, testing and commissioning Pumping sets, centrifugal monoblock pump having effieiency not less than 75, cast iron body, electric driven,415 volt suitable for 15.8 LPS at 36 Mtr head inclusive of PCC foundation as per Manufacturer's instruction complete all as specified and directed (1 W + 1S)
External Electric Supply
Supply & install GOD for triple pole, Horizontal or vertical type mechanical operated mounted on insulated and steel frame with 09 Nos Insulators, with operating mechanism from ground level operating through and including 25mm dia light grade GI pipe including connecting with aluminium jumpers, testing and commissioning complete for current rating upto 200 AMP, 11000 Volts complete all as specified
M&L Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-55 (11 metres long) to make a 4 pole arrangement by adding 2 Nos poles to existing 2 pole structure completed all as specified and directed
Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as specified
Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as specified
Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified
Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified
Supply, lay and testing cable XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 11000 volts(E) grade with stranded aluminium conductor of size 3 core 185 sqmm complete all as specified
Supply, lay and testing cable XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 11000 volts grade with stranded aluminium conductor of size 3 core 95 sqmm complete all as specified (Note : Cable shall be used for shifting of existing cable from proposed site.)
M & L for earthing complete with galvanised steel earth plate electrode of size 600mm x600mmx6.0 mm thick burried directly under ground vertically to a depth not less than 2.25 meter below ground level with top edge of the plate at a depth not less than 1.5 m below ground level connected to and including galvanised strip 32 x 6mm, by means of bolts, nuts, check nuts and washeres made out of GI including protection pipe GI light grade 40 mm size and watering pipe 20 mm dia GI medium grade all as shown on plate No 3 of SSR Part-I, connecting to earthing test point, including necessary earth work in any type of soil, PCC earth chamber made in PCC 1:3:6 type C1 (using 20mm graded aggregate), common salt, charcoal, CI funnel, earth pit cover in RCC 1:2:4 type B1 (using 20mm graded aggregates), with 8mm CTD bars @ 140mm c/c in both ways, including necessary form work complete including necessry test on completion all as specified and as directed. (for CSS, LT panel, APFC panel, 4 pole structure,Lift,Fire Fighting pumps and Water Supply pump sets)
All as per item No.48 here-in-before but with 4 mm dia earth lead including GI pipe light grade 15mm dia for earth lead protection complete all as specified and as directed.
Cutting of hardstanding/ road for laying protection pipe of cable of required width and depth including connecting, laying of pipe and finishing the disturbed surface to match with the existing surface complete all as directed. Note : GI pipe shall be measured and paid separately.
Supply and fix aviation obstruction light LED type comprising of aluminium housing with polycarbonate enclosure of Make - Bajaj, Cat No BGAV 302 LED or equivalent in other approved makes as specified and directed
Supply, lay and testing cable XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 4 core 25 sqmm
All asper item No. 52 here-in-before but for cable size 3.5 core 35 Sqmm
All asper item No. 52 here-in-before but for cable size 3.5 core 70 Sqmm
All asper item No. 52 here-in-before but for cable size 3.5 core 120 Sqmm
All asper item No. 52 here-in-before but for cable size 3.5 core 240 Sqmm
All asper item No. 52 here-in-before but for cable size 2 core 6 Sqmm
Metering Panel 1,2,3 : Supply, installation, testing and commissioning of LT metre panel board (Indoor type) with 2mm thick CRCA Sheet steel cubical type comparmentalised, having busbar capacity 315A, ammeter with CT's, voltmeter, indicating lamps with and following breakers as incoming and Outgoings. Incoming : 4 pole MCCB 200A, 415V, 50Hz with breaking capacity 25 KA, O/C and E/F protection - 01 No, Outgoing : 4 Pole MCCB 63 Amp, 50 Hz, 415 V with rupturing capacity 16 KA - 01 No (Spare) (Common DB), DP, MCB, 6 - 32A,240V,16 kA - 15 Nos (13 for DUs and 02 - spare) single phase Energy meter : AC single phase Smart meter with prepayment mode all as per IS 16444: 2015 (reaffirmed 2020) and as amended from time to time of accuracy class 1.0 ,240 V, rating 5-60 Amps, 50Hz with Backlit LCD display (measures and displays KWH ,V, Current I, KW, pf last month history of KWH, MD in KW) with special features like TOD, temper logging, optical communication port display in absence of power with transparent hinge type box. - 13 Nos (for PO's block 13 Qtrs + Common DB) NOTE : Detailed functions of KWH meters are given in particular specifications.
Metering Panel 1a, 2a, 3a: Supply, installation, testing and commissioning of LT metre panel board (Indoor type) with 2 mm thick CRCA Sheet steel cubical type comparmentalised, having busbar capacity 315A, ammeter with CT's, voltmeter, indicating lamps with and following breakers as incoming and Outgoings. Incoming : 4 pole MCCB 200A, 415V, 50Hz with breaking capacity 25KA, O/C and E/F protection - 01 No, Outgoing : 4 Pole MCCB 63 Amp, 50 Hz, 415 V with rupturing capacity 16 KA - 01 No (Spare), DP, MCB, 6 - 32A, 240V,10 kA - 15 Nos (13 for DUs and 02 - spare)., 1 phase Energy meter : AC single phase Smart meter with prepayment mode all as per IS 16444: 2015 (reaffirmed 2020) and as amended from time to time of accuracy class 1.0 ,240 V, 5-60 Amps, 50Hz with Backlit LCD display (measures and displays KWH ,V, Current I, KW, pf last month history of KWH, MD in KW) with special features like TOD, temper logging, optical communication port display in absence of power with transparent hinge type box., - 13 Nos.(for PO's block 13 Qtrs) NOTE : Detailed functions of KWH meters are given in particular specifications.
Metering Panel 4: Supply, installation, testing and commissioning of LT metre panel board (Indoor type) with 2 mm thick CRCA Sheet steel cubical type comparmentalised, having busbar capacity 315A, ammeter with CT's, voltmeter, indicating lamps with and following breakers as incoming and Outgoings. Incoming : 4 pole MCCB 250A, 415V, 50Hz with breaking capacity 25KA, O/C and E/F protection - 01 No, Outgoing : 4 Pole MCCB 63 Amp, 50 Hz, 415 V with rupturing capacity 16 KA - 01No (Spare) (Common DB), DP, MCB, 6 - 32A,240V,10 kA - 18 Nos (16 for DUs and 02 - spare)., 1 phase Energy meter : AC single phase Smart meter with prepayment mode all as per IS 16444: 2015 (reaffirmed 2020) and as amended from time to time of accuracy class 1.0 ,240 V, 5-60 Amps, 50Hz with Backlit LCD display (measures and displays KWH ,V, Current I, KW, pf last month history of KWH, MD in KW) with special features like TOD, temper logging, optical communication port display in absence of power with transparent hinge type box. - 16 Nos.(for MCPO block 16 Qtrs) NOTE : Detailed functions of KWH meters are given in particular specifications.
DG Panel : Supply, installation, testing and commissioning of LT metre panel board (Outdoor type) with 3 mm thick CRCA Sheet steel cubical type comparmentalised, having busbar capacity 400A, ammeter with CT's, voltmeter, indicating lamps with and following breakers as incoming and Outgoings. Incoming : 4 pole MCCB 400A, 415V, 50Hz with breaking capacity 25KA, O/C and E/F protection - 01 No, Outgoing : 4 Pole MCCB 12 to 63 Amp, 50 Hz, 415 V with rupturing capacity 16 KA - 12 nos.,
Supply and fix 45 W LED street light made up of pressure die cast housing with with toughened glass and high power LEDs with option of secondary optic with IP 65 protection
M & L junction box made out of polycarbonate for loop in / out with all fixing arrangement on pole with one MCB SP 6A for LED light including 10 metre 1.5 sqmm 2 core fixible cables
Supply and fixing of solar all in one 45W LED street lighting - smart integrated solar street light with build in Poly Crystalline Panel, lithium ferro phospate (LiFePO 4) battery, MPPT charge controller and PIR sensor and 6mtr height pole. Philips catalogue no. BRP710 LED45 CW MR S1 12V LFP Solar IN or equivalent of other approved makes
Supply errection, testing and commissioning 11kV Outdoor Package Sub-Station (CSS) complete with the of following :-
HT SWITCHGEAR 11kV 630A 21kA/3s SF6 Insulated Non-Extensible Compact switchgear consisting of 1 NoFixed Type Manual Load Break switch and 1 No. Fixed Type Manual Operated Vacuum Circuit Breakers in SF6 insulated stainless steel enclosure of thickness 2.5mm with series trip, self powered microprocessor based numerical over current relay (IDMTL + Inst.) protection. (Type CV- NE) (a) Interconnection between HT switchgear and transformer shall be using 1Cx3x95 sq.mm Aluminium unarmorured XLPE Cable. (b) Self powered over current and earth fault protection Relay ( 50,50N,51,51N) with RS 485 communication port . (Make: Ashida/C&S) - 1 No (c) CT - 40/1A, 2.5 VA, CL - 5P10 for Protection. (d) Fault passage Indicator for incoming LBS - 1 No (e) Manometer - 01 No (f) Voltage Presence Indiactor - 3 Nos (g) Operating Handle - 01 Nos (h) Incoming module of the RMU shall be suitable for cable termination upto 3C X 400 sq.mm Al cable.
TRANSFORMER - 01 No 500 KVA, 11KV/433V DYn11 Dry resin type fully hermatically sealed transformer with corrugated wall design & Top Bushings for LT with Off load tap switch of rating +5% to -10% in steps of 2.5%. Temp rise over amb temp 50 Deg C: 40/45 for Oil/Winding respectively. Insulation Class A; (Losses as per IS 1180 Energy Efficiency level-2 ) (a) Oil Temperature Indicator with Alarm and Trip Contact - 01 Nos (b) Winding Temperature Indicator with Alarm and Trip Contact - 01 set (c) Pressure Relief Device - 1 No (d) Surge arrester (e) Door interlock with the breaker - 1 No (f) Buchholz relay - 1 No
LT Panel 433V with Aluminium busbars suitable for 1000A, Fabrication using 1.5/2 MM CRCA sheet steel , Ingress protection IP2X , complete with internal wiring consisting of following :- (a) INCOMER FROM TRANSFORMER (i) 630 - 1000 Amps 433V 4P 50Hz 50KA Manually Fixed Type Air Circuit breaker (ACB) with Microprocessor based release for over current, short circuit and earth fault protection - 1 set (ii) Metering CT - 1000/5A 5VA Class 1.0 Accuracy (iii) Digital Multifunction Meter of Class 1.0 Accuracy 1 No (iv) RYB,ON,OFF,TRIP LED Indication Lamps - 1 Set (b) Outgoing : (i) 350 Amps 433V TPN 36KA Manually Fixed type Molded Case Circuit Breaker (MCCB) with Thermal Magnetic Based over current & short circuit fault Release. - 02 Nos (ii) 200 Amps 433V TPN 36KA Manually Fixed type Molded Case Circuit Breaker (MCCB) with Thermal Magnetic Based over current & short circuit fault Release. - 04 Nos (iii) 100 Amps 433V TPN 25KA Manually Fixed type Molded Case Circuit Breaker (MCCB) with Thermal Magnetic Based over current & short circuit fault Release. - 04 Nos
Outdoor type enclosure having modular construction of CRCA sheet of thickness minimum 2mm with 4mm HRCA baseframe. The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP23 degree of protection for Transformer compartment. The enclosure exterior shall be powder coated ( colour Light Gray & D.A.Gray ). Each compartment will be provided with the door and pad locking arrangement. The Compartment illumination lamp with door operated switch shall be provided for MV & LV compartment. Seperate Switch operated bulket lamp + Hooter in Transformer compartment - 1 set Interlock between Transformer Door and HT Breaker , if door opens it trips the main breaker.
Interconnection & Earthing : Interconnection Between HT switchgear & Transformer using 1Cx3x95Sq.mm XLPE Aluminium Single core cable & Interconnection between Transformer & LT switchgear using Aluminium Busbars. Internal earthing connections by using 32x6 mm Aluminium including Transformer Neutral. - 6 Nos NOTE: 1. CSS shall be with 2 mm thick CRCA sheet for load bearing member and 1.5mm for non-load bearing members. 2.CSS shall be mounted directly on installation plinth and no base channels are envisaged. 3.Package Sub-station will be complete with the internal interconnections & earthing. Accessories required for the external connections of HT & LT cables like termination kits , lugs , glands etc & extending of earth bar to earth pits is not included in the our scope of offer. 4. Transformer- Transformer shall be as per IS 1180 Energy Efficiency Level 2 only as per new guidelines of Ministry of Power.
5.Cable termination arrangement shall be from Bottom for HT & LT side. 6.Interconnection cable between HT side V ( Breaker ) Module to transformer shall be Aluminium - 1Rx3Cx95 sqmm 7.The enclosure exterior shall be powder coated ( colour Light Gray & D.A.Gray ) instead of polyurhethene paint 8.Door of Transf shall be fitted with Arc reflectors from the inside of providing better safety - It cannot be provided on Transformer door
Supply and fix Steel tubular swaged poles, swan neck complete with cast iron base plate, finial tape plug, bolts, nuts and screws as specified type 410 SP-22 (8.5 metres long)
Street light feeder pillar: Supply, installation, testing and commissioning of LT metre panel board (Outdoor type) with 3 mm thick CRCA Sheet steel cubical type comparmentalised, having busbar capacity 60A, ammeter with CT's, voltmeter, indicating lamps with and following breakers as incoming and Outgoings. Incoming : TPN MCB 32A, 415V, 50 Hz with breaking capacity 10 kA - 01 No, Outgoing : DP MCB 32 Amp, 50 Hz, 230 V with rupturing capacity 10 KA - 2 Nos ( 01 - street lights, 01 - spare), Astronomical Time switch and contractor 16A, single phase - 1 No
Riddled soil as earth cushioning to UG cable by using IS sieve to separate the composite particle/roots etc and refilling/spread in trenches as cushioning and rammed down to form a solid bed all as specified and as directed. Note :- 1. Punned thickness shall be measured and paid separately. 2. Excavated approved soil shall be riddled by using sieve to separate composite particles etc as per IS.
LIGHTNING PROTECTION
Earthing complete with galvanised steel earth plate electrode of size 600mm x600mmx6.0 mm thick burried directly under ground vertically to a depth not less than 2.25 meter below ground level with top edge of the plate at a depth not less than 1.5 m below ground level connected to and including galvanised strip 32 x 6mm, by means of bolts, nuts, check nuts and washeres made out of GI including protection pipe GI light grade 40 mm size and watering pipe 20 mm dia GI medium grade all as shown on plate No 3 of SSR Part-I, connecting to earthing test point, including necessary earth work in any type of soil, PCC earth chamber made in PCC 1:3:6 type C1 (using 20mm graded aggregate), common salt, charcoal, CI funnel, earth pit cover in RCC 1:2:4 type B1 (using 20mm graded aggregates), with 8mm CTD bars @ 140mm c/c in both ways, including necessary form work complete including necessry test on completion all as specified and as directed.
FIRE FIGHTING & FIRE DETECTION SYSTEM
Supply and fix Automatic air release valve 50mm dia suitable for domestic water with 50mm gun metal stop valve complete
Supply, installation, testing and commissioning of Sounder cum Strobe rated at 75 dBA 32 built in tones CPD Approved Low power requirements High power LED beacon Optional IP65 rating Optional built-in isolator The sounder shall be UL lsitedamd LPCB Approved to EN 54 complete all as specified and as directed make :NOTIFIER - NOTIFIER / SIEMENS /HONEYWELL (MORLEY IAS)
Supply, installation, testing and commissioning of Addressable Manual Call Point (Pull down / Break Glass Type) including control module. Fire Alarm Call Points shall use a key operated test without the need to break the glass,The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device, provided with necessary fittings and accessories. The module shall be UL lsited and FM approved complete all as specified and as directed make :MAKE: NOTIFIER / SIEMENS /HONEYWELL (MORLEY IAS)
Supply, installation, testing and commissioning of Fire Alarm Repeater/Annunciator Panel shall display fire/fault messages simultaneously with the FACP. It shall be capable of interfacing with the FACP on a single RS 485 Bus. The panel shall have a 2 x 40 character backlit alphanumeric LCD display, which shall display date, time & description of alarm/trouble events that are displayed in the FACP with an inbuilt buzzer to indicate fault/fire alarm.The repeater panel shall have the following LED‘s indications Supply,Fault, Mute, Silent,Disabled and Fire. The panel shall be capable of operating on 24 V DC supply. EN 54 approved complete all specified and as directed.( Make : Honeywell- Morley IAS)
supply and fix wall mounted LED emergency Exit sgnage luminaire lit up using regular mains supply comes with a unique rechargeable Ni-cd battery capable of emergency back up upto 05 hours ( Cat No LSSR5W Make CG or equivalent to Bajaj/Havells)
Supply, installation, testing and commissioning of Intelligent Addressable 1 Loop Main Fire Alarm Panel The control panel shall be capable of expansion using 2 plug-in loop driver modules shall be available. The control panel shall support up to 2 analogue addressable loops with the capability to control 200 analogue sensors and 200 addressable modules, giving the maximum capacity of 400 addresses,The panel shall have 14 general panel status LED’s. An alphanumeric liquid crystal display shall give 80 characters of information on a 2-line display. Four separate pushbuttons shall provide control of Sound Alarms (Evacuate), Silence/Resound, Mute/Accept and Reset, and shall be located adjacent to the main LED indication.The panel shall have two serial communication ports. An optional ‘plug-in’ RS 485 or RS232 card will support panel network connection. An RS 485 peripheral bus shall support a further, Peripheral devices shall include; display only and active repeater panels, remote printers, Built in auto programme features. simple and straight forward user inerface. The power supply shall operate on 230 Volts AC , 50Hz and shall provide all necessary power for the control panel in the event of Mains electrical failure the fire alrm control panel shall be fitted with an integral 0.7 Amp battery charger , curent limited with DDP for 24 Volt maintenance free batteries. EN 54 approve comlete all as specified nd as directed. :MAKE: NOTIFIER / SIEMENS /HONEYWELL (MORLEY IAS) .Designed to meet UL listed and NFPA 72 approved make complete all as specified and as directed MAKE: NOTIFIER / SIEMENS /HONEYWELL (MORLEY IAS)
Supply, installation, testing and commissioning of Intelligent Addressable 1 Loop Main Fire Alarm Panel The control panel shall be capable of expansion. capacity of upto 2 analog addressible detection loops, using 5 plug-in loop driver modules shall be available. The control panel shall support up to 5 analogue addressable loops with the capability to control 99 analogue sensors and 99 addressable modules, giving the maximum capacity of 200 addresses,The panel shall have 14 general panel status LED’s. An alphanumeric liquid crystal display shall give 80 characters of information on a 2-line display. Four separate pushbuttons shall provide control of Sound Alarms (Evacuate), Silence/Resound, Mute/Accept and Reset, and shall be located adjacent to the main LED indication.The panel shall have two serial communication ports. An optional ‘plug-in’ RS 485 or RS 232 card will support panel network connection. The panel shall have 2 serial communication ports. An optional "Plug-in" Rs 485 for RS 232 card will support panel network connection . An RS 485 peripheral bus shall support a further, Peripheral devices shall include; display only and active repeater panels, remote printers, Built in auto programme features. simple and straight forward user inerface.
The power supply shall operate on 230 Volts AC , 50Hz and shall provide all necessary power for the control panel in the event of Mains electrical failure the fire alrm control panel shall be fitted with an integral 0.7 Amp battery charger , curent limited with DDP for 24 Volt maintenance free batteries as required and as as directed. :MAKE: NOTIFIER / SIEMENS /HONEYWELL (MORLEY IAS) NOTE : (i) The Master panel which is located in PO-3 Block and all other panels are to be networkable with this panels , from there Repeater panel will be connected at Fire Station as per the Schematic digram. (ii) Cable for inter connection of FACP & Repeater panel shall be measured and paid separately.
Supply and lay High Density Polythelene Pipes (HDPE pipes) of size 50 mm dia IS 4984 PE 80 SDR-17/PN -6 laid in trenches all as specified and directed.
Supply,draw, connecting, testing and ommissioning, testing and commsioning 2 Core 1.5 Sqmm stranded copper conductor , PVC insulated, PVC sheathed , GI steel strip FRLS armoured cable fitted on surface/trenches by providing necessary saddles, sockets , glands and boxes etc... complete all as specified and as directed .
Cutting the existing bituminous road/PCC hard standing/tile walk way/hard rock n.exc 1.5 m wide n.exc 1.5 m deep
Supply, lay, testing and commissioning of flexible 2 core 1.5 Sqmm copper conductor, pvc insulated, Cross laid up, Overall Aluminum Mylar tape shielded along with ATC drain wire PVC Outer Sheated Cable laid in existing complete as required and as directed .
SEWAGE DISPOSAL
Supply and laying of DWC PE Pipe (SN8) 180 (OD)/163 (ID) mm dia laid and jointed including all fittings and fixtures complete all as specified
Supply and laying of DWC PE Pipe (SN8) 200 (OD)/183 (ID) mm dia laid and jointed including all fittings and fixtures complete all as specified
direction section in start operation requiring no human intervention ,rescues during power/system failure with latest IGBT power devises, 3D infra red sensor in full length of doors and built in floor announcing system with 4 Nos hand set one each in car, machine room and near ground floor landing door and over load indicator with suitable for three phase,415 Volts,50 Hz AC Supply for passenger lift including all connected civil works and provisions as mentioned in particular specification all as specified and as directed ( MCPOs block. Note:(i) Item Earthing and LT cable, MCCB shall be measured and paid under external Elect supply schedule. (ii) contractor shall submit GA drg for approval of accepting officer
All as per item Sl No 87 here-in-before but suitable for to serve Ground floor plus Six upper floors(G+6) complete (1 No each per PO's block)
direction section in start operation requiring no human intervention ,rescues during power/system failure with latest IGBT power devises, 3D infra red sensor in full length of doors and built in floor announcing system with 4 Nos hand set one each in car, machine room and near ground floor landing door and over load indicator with suitable for three phase,415 Volts,50 Hz AC Supply for passenger lift including all connected civil works including provisions as mentioned in particular specification all as specified and as directed (1 No lift per POs block). Note:(i) Item Earthing and LT cable, MCCB shall be measured and paid under external Elect supply schedule. (ii) contractor shall submit GA drg for approval of accepting officer
DG SET
Supply and install , testing and commissioning of diesel engine driven generating set with AMF PANEL panel 160 KVA/128KW with water cooled engine @ RPM 1500, brushless frame with silencer and Canopy for sound less mode (sound level not exceeding level specified by central pollution control board) and all engine accessories such as self starter, alternator/dynamo and 160 KVA/128KW electric alternator, 415 volts, 3 phase, 4 wire,50 Hz, Voltage Regulation ± 15, Insulation class H coupled to engine with suitable coupling and base frame on foundation as recommended by the manufacturer and consisting of other electrical components, fuel tank of capacity not lesss than 12 hrs run with level indicator installed on suitable steel frame with PCC foundation as per manufacturers instructions, Power Command genset Controller, fuel pipes, Dual spin on fuel filter, Dry resin type Aircleaner, Shutt off coil with safeties for LLOP/HWT , fuel pipes , bar metre, hour meter , oil temperature gauges, ammeter, ignition switch, radiator with cooling fan, maintanance free battery, including suitable size of copper cable leads with terminals, all mountings ,accessories and necessary foundation and AVM pads complete as per manufacurers recommendations and to the satisfaction of Engr in charge. NOTE : The emission from DG Set shall not exceed the limit set by CPCB norms and the environment protection third amendment rule 2013, issued by Ministry of Environment and Forest, GoI, amended upto date.
A) PRIME MOVER :- Suitable for driving 160 KVA/128KW alternator water cooled battery start diesel Engine of adequate suitable capacity of BHP confirming of BSS 649 and fuel tank suitable for 12 hrs running capacity mounted on MS frame pedestal supported with anti-vibration mounting rated for continuous running capable of taking 10% over load for one hr in any 12 hrs operaton complete with the following standard accessories :- (a)Fly wheel to match with the flexible coupling (b)Flexible coupling wih guard (c)Air cleaner oil bath type / dry type (d)Lubricating oil filter, fuel filter paper element type (e)Blower type fan and radiator (f)Governor for class "A" Goverming as per IS-1601 of DS 649/1958 (g) Starter. Motor for electric start complete with dynamo altermator , lead acid batteries heavy duty of capacity as recommended by OEM & capacity as required with copper conductor leads of adequate size and length not less than 2 M including battery box all as directed. (h) Hour meter and RPM indicator (j) Exhaust pipe brough outside the building and lagging of entire length of exhaust pipe with 12 mm dia.
k) Instrument panel duly wired comprising the following including protection for low lub oils high temperature :- (i) Lube oil pressure gauge (ii) Battery charge indicator meter (iii) Starting switch with key (iv) Lub oil temperature (v) Water temperature
(iv) Rate quoted by the contractor including the rate of first filling of lubricating oil, Coolent and duct with wooden cover from DG set to AMF Panel. AMF panel must be out side the canopy. (v) Drawings/cataloge for DG Set and AMF panel got approved from GE before ordering to the manufaturer (vi) The emission from DG set shall not exceed the limits set by CPCB norms and the envoronment protection third amendment rules 2013, issued by Ministry of Environment and Forest, Govt of India, amended upto date
Earthing complete with galvanised steel earth plate electrode of size 600mm x600mmx6.0 mm thick burried directly under ground vertically to a depth not less than 2.25 meter below ground level with top edge of the plate at a depth not less than 1.5 m below ground level connected to and including galvanised strip 32 x 6mm, by means of bolts, nuts, check nuts and washeres made out of GI including protection pipe GI light grade 40 mm size and watering pipe 20 mm dia GI medium grade all as shown on plate No 3 of SSR Part-I, connecting to earthing test point, including necessary earth work in any type of soil, PCC earth chamber made in PCC 1:3:6 type C1 (using 20mm graded aggregate), common salt, charcoal, CI funnel, earth pit cover in RCC 1:2:4 type B1 (using 20mm graded aggregates), with 8mm CTD bars @ 140mm c/c in both ways, including necessary form work complete including necessry test on completion all as specified and as directed.
HOT WATER SUPPLY
Supply and fix electric water heater, storage type, steel body with stainless steel inner tank, and heating element upto 2KW capacity, 25 litres, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc. NOTE : 1. Outlet of water heater shall be connected to both bathrooms. Pipeline and fittings given at Ser No 95 & 96 shall be measured and paid separately. 3. Bib cock of hot water supply shall be deemed to be included in the lumpsum quoted againt Buildings mentioned at Ser Nos 1 & 2 of Schedule 'A' Part I.
Angular stop cock, chromium plated, screwed for 20mm bore CPVC pipe complete all as specified. Make Jaquar, Code No CON-059KN or equivalent of other approved makes.
Low density polythene pipe 16mm dia (outer), metallic baided, 450mm long suitable for cold/ hot water application complete with brass union on both sides complete all as specified
MISCELLANEOUS
Rigid non-metallic PVC conduit exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. of dia 20 mm
S&F TV socket one module including metal flush box and modular frame and cover
S&F RJ 11 telephone socket with transperent shutter one module including metal flush box and modular frame and cover
COMPREHENSIVE MAINTENANCE OF LIFTS AFTER DEFECT LIABILITY PERIOD
Comprehensive maintenance and servicing of passenger elevator 03 Nos Lifts of capacity (G+06) 08 persons, Speed 1.5 meter per second, 1380 RPM, 415 V, 50 Hz consisting of examining carrying capacity with ARD facility, adjusting, lubricating, greasing the parts and servicing as required of machine motor, gear box and electrical and mechanical controller parts of machine renewal of governer, renewal of hoist ropes and also servicing of gear box oil, alarm bells, fire switches, indicators, emergency light, lift lights, low voltage protection relay, including servicing/ rewinding of motors and cabin fans etc for smooth functioning of lift complete all as specified and directed for lifts as mentioned at BoQ Item Sl No 89 here-in-before for the first year after completion of defect laibility period. Location : PO's Block
Comprehensive maintenance and servicing of passenger elevator 01 No Lift of capacity (G+04) 13 persons, Speed 1.5 meter per second, 1380 RPM, 415 V, 50 Hz consisting of examining carrying capacity with ARD facility, adjusting, lubricating, greasing the parts and servicing as required of machine motor, gear box and electrical and mechanical controller parts of machine renewal of governer, renewal of hoist ropes and also servicing of gear box oil, alarm bells, fire switches, indicators, emergency light, lift lights, low voltage protection relay, including servicing/ rewinding of motors and cabin fans etc for smooth functioning of lift complete all as specified and directed for lifts as mentioned at BoQ Item Sl No 87 here-in-before for the first year after completion of defect laibility period. Location : MCPO's Block
Comprehensive maintenance and servicing of passenger elevator 03 Nos Lifts of capacity (G+06) 13 persons, Speed 1.5 meter per second, 1380 RPM, 415 V, 50 Hz consisting of examining carrying capacity with ARD facility, adjusting, lubricating, greasing the parts and servicing as required of machine motor, gear box and electrical and mechanical controller parts of machine renewal of governer, renewal of hoist ropes and also servicing of gear box oil, alarm bells, fire switches, indicators, emergency light, lift lights, low voltage protection relay, including servicing/ rewinding of motors and cabin fans etc for smooth functioning of lift complete all as specified and directed for lifts as mentioned at BoQ Item Sl No 88here-in-before for the first year after completion of defect laibility period. Location : PO's Block
Comprehensive maintenance and servicing of passenger elevator 03 Nos Lifts of capacity (G+06) 08 persons, Speed 1.5 meter per second, 1380 RPM, 415 V, 50 Hz consisting of examining carrying capacity with ARD facility, adjusting, lubricating, greasing the parts and servicing as required of machine motor, gear box and electrical and mechanical controller parts of machine renewal of governer, renewal of hoist ropes and also servicing of gear box oil, alarm bells, fire switches, indicators, emergency light, lift lights, low voltage protection relay, including servicing/ rewinding of motors and cabin fans etc for smooth functioning of lift complete all as specified and directed for lifts as mentioned at BoQ Item Sl No 89 here-in-before for the second year after completion of defect laibility period. Location : PO's Block
Comprehensive maintenance and servicing of passenger elevator 01 No Lift of capacity (G+04) 13 persons, Speed 1.5 meter per second, 1380 RPM, 415 V, 50 Hz consisting of examining carrying capacity with ARD facility, adjusting, lubricating, greasing the parts and servicing as required of machine motor, gear box and electrical and mechanical controller parts of machine renewal of governer, renewal of hoist ropes and also servicing of gear box oil, alarm bells, fire switches, indicators, emergency light, lift lights, low voltage protection relay, including servicing/ rewinding of motors and cabin fans etc for smooth functioning of lift complete all as specified and directed for lifts as mentioned at BoQ Item Sl No 87 here-in-before for the second year after completion of defect laibility period. Location : MCPO's Block
Comprehensive maintenance and servicing of passenger elevator 03 Nos Lifts of capacity (G+06) 13 persons, Speed 1.5 meter per second, 1380 RPM, 415 V, 50 Hz consisting of examining carrying capacity with ARD facility, adjusting, lubricating, greasing the parts and servicing as required of machine motor, gear box and electrical and mechanical controller parts of machine renewal of governer, renewal of hoist ropes and also servicing of gear box oil, alarm bells, fire switches, indicators, emergency light, lift lights, low voltage protection relay, including servicing/ rewinding of motors and cabin fans etc for smooth functioning of lift complete all as specified and directed for lifts as mentioned at BoQ Item Sl No 88 here-in-before for the second year after completion of defect laibility period. Location : PO's Block
Comprehensive maintenance and servicing of passenger elevator 03 Nos Lifts of capacity (G+06) 08 persons, Speed 1.5 meter per second, 1380 RPM, 415 V, 50 Hz consisting of examining carrying capacity with ARD facility, adjusting, lubricating, greasing the parts and servicing as required of machine motor, gear box and electrical and mechanical controller parts of machine renewal of governer, renewal of hoist ropes and also servicing of gear box oil, alarm bells, fire switches, indicators, emergency light, lift lights, low voltage protection relay, including servicing/ rewinding of motors and cabin fans etc for smooth functioning of lift complete all as specified and directed for lifts as mentioned at BoQ Item Sl No 89 here-in-before for the third year after completion of defect laibility period. Location : PO's Block
Comprehensive maintenance and servicing of passenger elevator 01 No Lift of capacity (G+04) 13 persons, Speed 1.5 meter per second, 1380 RPM, 415 V, 50 Hz consisting of examining carrying capacity with ARD facility, adjusting, lubricating, greasing the parts and servicing as required of machine motor, gear box and electrical and mechanical controller parts of machine renewal of governer, renewal of hoist ropes and also servicing of gear box oil, alarm bells, fire switches, indicators, emergency light, lift lights, low voltage protection relay, including servicing/ rewinding of motors and cabin fans etc for smooth functioning of lift complete all as specified and directed for lifts as mentioned at BoQ Item Sl No 87 here-in-before for the third year after completion of defect laibility period. Location : MCPO's Block
Comprehensive maintenance and servicing of passenger elevator 03 Nos Lifts of capacity (G+06) 13 persons, Speed 1.5 meter per second, 1380 RPM, 415 V, 50 Hz consisting of examining carrying capacity with ARD facility, adjusting, lubricating, greasing the parts and servicing as required of machine motor, gear box and electrical and mechanical controller parts of machine renewal of governer, renewal of hoist ropes and also servicing of gear box oil, alarm bells, fire switches, indicators, emergency light, lift lights, low voltage protection relay, including servicing/ rewinding of motors and cabin fans etc for smooth functioning of lift complete all as specified and directed for lifts as mentioned at BoQ Item Sl No 88 here-in-before for the third year after completion of defect laibility period. Location : PO's Block
Agarwal Jagdish Construction Company Pvt. Ltd.
GOVARDHAN AND COMPANY
Kurian And Varghese
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid