Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.7 LAccepted-AOC 0 BADRI ELECTRICALS NEAR SHRIGOR FALI NEAR ANADABAWA CHAKLO JAMNAGAR GUJARAT 361001 UDYAM GJ 10 0001822 | JAMNAGAR | GUJARAT | 361001 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹19.9 L+₹3.7 L (22.9%)Rejected-AOC | L2 | Rejected-AOC Being not L1 |
Tender Value
Refer Docs
EMD Value
₹34,000
Closing Date
23 Jul 2024, 6:00 pmClosed
Sachin Singhal EE GE Army Baroda
Opp Akashwani, Makarpura road PO-ONGC Baroda-390009
As per BOQ
2024_MES_661165_1
8804
Open Tender
Civil Works
Item Rate
330 days
GE ARMY BARODA
As per tender documents
5 documents required · 5 mandatory
₹500
Yes
GE ARMY BARODA
₹34,000
Yes
19 Oct 2024
21 Jun 2024
29 Jul 2024
21 Jun 2024
23 Jul 2024
5 Jul 2024
21 Jun 2024 - 4 Jul 2024
Amount
Excavation in trenches n.exc 1.5 mtr wide and n exc 1.5m in depth, for, foundation, taking out/ laying cable / pipe line or for shafts, wells, cesspits,manholes, pier holes, etc n.exc 10 sq mtr on plan and n.exc 1.5 mtr depth and getting out in soft/loose soil.
Returning filling in trenches excavated soil including spreading levelling watering and well ramming in layers n.exc 25 cm.
Removing excavated materials n.exc 50 mtr depositing where directed at a level n.exc 1.5 m above the starting point.
M & L for sand cushioning to PVC cable with using clean dry and natural river sand gently punning below/around cable all as specified. Note:- Punned thickness shall be measured for payment.
M & L for well burnt bricks sub class 'B' as in protection of cable, laid dry, flat abutting each other width wise all as directed
Taking out existing LT under ground cable 1100 volts grade from trenches/ducts/pipe, on wall, poles of following size :-
16 sq mm 4 core
Supply and Laying including jointing and testing electric under ground LT cable PVC/XLPE insulated armoured aluminium conductor cable 1100 volts grade in trenches ducts, pipe on walls, poles of following sizes Make Polycab/Havells/Gloster
16 sq mm 4 core
M&L for GI tubing light grade fixed on wall/pole laid in trenches/under road of the following sizes :-
50 mm dia bore
M&L for KAPITRODE Earthing with Cast Iron pipe electrode, 75mm bore, 3.15mm wall thickness , 2.9 metres length,with GI pipe & funnel, buried directly and preferably vertically in ground with top edge not less than 2.9 metres below ground level connected with earthing lead of 25x5mm dia galvanised iron strip including the following, : - (a) Excavation and earth work for drilling hole for electrode in any type of Soil. (b) PCC pit in cement concrete 1:2:4 type B-1 of size 450x450x450mm with Cast iron cover with suitable handle. (c) 40 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead. (d) Requisite quantity of BFC Compound (bentonide powder) and black cotton soil. (e) Testing of earthing. NOTE :- On testing after completion of earthing, if the desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk and cost.
Taking out cable loop after dismantling cable ends from panels, cutting/removing heated cable ends with burnt lugs and inserting new lugs after cutting opening of fresh cable end complete including earth work and relaying cable neatly around loop for cable size 50 to 120 Sqmm.
S & F in replacement steel tubular swaged pole with cast iron base plate , finial plug, bolts, nuts and screws as specified type 410 SP-31 of length 9 mtr including earth work, PCC 1:3:6 type C2 for foundation, PCC 1:3:6 type C1 copping all around the pole duly painted with aluminium paint over a red oxide primer as per SSR specification and directed.
Dismantling/taking out old defective cable form street light poles (Junction box to fitting/overhead line to fitting) and supply and fix aluminium conductor multistranded/solid on poles or passing through steel or PVC conduit pipe 1100 volts grade with suitable cable lugs, clamps, nut bolts etc complete as per specification as required of following sizes :-
4 Sqmm two core conductor.
6 Sqmm two core conductor
S & F bracket with clamp for fixing street light fitting made out of GI pipe light grade of followinb bore, including bending to shape, of length 1.5 m complete :-
25 mm bore
40 mm bore
Supply and fix in repair LED Post top lantern with die cast aluminium spigot ,spun aluminium powder coated top cover aluminium PDC heat sink opal PC diffuser and clear acrylic IP 65 of 45 watt Make CG / Halonix / Orient /Philips
Supply and fix in repair Pillar / Post Garden light fitting Acrylic white Doom water proof with black metal base outdoor type.Make CG /Halonix/Orient/Philips
Taking down old defective Street Light and Supply & Fix in replacement of 90 Watt LED Street Light fitting New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP OPENING seperate driver compartment with IP66 protection and impact resistance of IK07 with 10KV Built-in Surge Protection Device .Make: Halonixs,Polycab, Orient, Crompton.
Taking down old defective Street Light and Supply & Fix in replacement of 35 Watt LED Street Light fitting New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP OPENING seperate driver compartment with IP66 protection and impact resistance of IK07 with 10KV Built-in Surge Protection Device Make: Halonixs,Polycab, Orient, Crompton.
S&F in replacement street light box of PVC (make: sintex or equivalent) consisting of 01 No MCB 10 Amps, 10 KA capacity (Single phase) including aluminium strip
M & L for preparation of existing old painted surface of any description such as LT/HT steel tubular electric pole/struts of any height and painted completed including cross arms bracing clamps etc with one coats of aluminium paint and in white/blue alternative strips of 30 cm width each all around the poles up to 1.5 M height form the ground level/top of PCC copping including writing MES, LT/HT feeder No. and Pole No. (in capital letters) stencil cut decorative manner on pole using fluorescent paint as directed.
Taking down unseviceable fitting and supply and fixing LED Flood Light , 250 W Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium non integral IP66 flood light, suitable for high mast application, highlighting architectural facade and general purpose lighting. Make- Havells, Model-Phillips/Wipro/CG, Halonix
Supply, installing, testing and commissioning factory made LT feeder pillar box (KIOSK) outdoor type platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system all as specified and directed having bus bar installed on DMC/Epoxy insulators. The panel shall be dust and vermin proof, IP-65 class protection and made of 2.0 mm Stainless steel SS-316 grade sheet with double door shutter and locking arrangement, front and back opening, using stainless steel hinges, bolts and nuts & washer etc. The panel is including platform with PCC 1:4:8 type D-2 with 40mm crushed stone aggregate 20cm in thick in foundation and of height 0.9 mtr above the nearest road level. The TPN aluminium bus bar of rating not less than the 1.5 times the rated capacity of the incomer MCCB (a) MCCB 4 pole 16 kA 63 Amps with tinned copper link 01 No (Incommer) (b) MCB 4 pole 10 kA 32 Amp - 03 Nos (c) Phase indicator lamps(R-Y-B) -01 set of three (d) Automatic street light switch of rating 8 KW in three phase using nature sensor for automatic switching "ON/OFF" of steel lighting based on lux level of natural light along with 40 Amps Four pole contactor, MCB 40 Amps four pole with support terminals prewired with PVC insulated 25 sqmm multi strand copper wire enclosed/housed in pole wall mounted enclosure made of rust proof, shock proof, termite proof & dust proof FR grade moulded compound Junction Box complete all as specifed Model-SWADEEP -02EC 8KW 3P, Make - Nature switch/Kaktiya Energy systems Pvt Ltd/HEALER/BAJAJ2. Contactor :BCH/L&T/Schneider 3. MCB: Hager/Schneider/Legrand 4. Circuit wiring : Finolex/Polycab - 02 Nos (Timers two Nos for each panel for different ciruits)
Repair/Replacement of LED Driver 230 Volt 50 Hz for existing street light fitting of 40/70/72 watt of Make Bajaj ,CG/Wipro/Philips/Havells/shakti .
Repair/Replacement of LED Driver 230 Volt 50 Hz for existing street light fitting of 90/100 watt of Make Bajaj /CG/Wipro/Philips/Havells/shakti
P K SHETH (BID ID -3063805)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .