| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹67.9 LAccepted-AOC 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | L1 | Accepted-AOC Lowest and reasonable bidder | |
| 2 | L2₹72.6 L+₹4.7 L (6.94%)Rejected-Finance GURDASPUR ROAD NEAR SAINIK MANDIR PATHANKOT 145001 PB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L2 | Rejected-Finance Not lowest | |
| 3 | L3₹75.0 L+₹7.1 L (10.5%)Rejected-Finance 13 29 3RD FLOOR EAST PATEL NAGAR NEW DELHI 110 008 | WEST | DELHI | 110008 | L3 | Rejected-Finance Not lowest | |
| 4 | L4₹81.2 L+₹13.4 L (19.7%)Rejected-Finance V P O SAROTARI TEHSIL BAROH DISTRICT KANGRA PIN 176037 HP | KANGRA | HIMACHAL PRADESH | 176037 | L4 | Rejected-Finance Not lowest | |
| 5 | L5₹81.9 L+₹14.0 L (20.6%)Rejected-Finance BOOTH NO 119 SECTOR 9 PANCHKULA 134109 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134109 | L5 | Rejected-Finance Not lowest |
Tender Value
₹76 L
EMD Value
₹1.4 L
Closing Date
26 Sept 2023, 6:00 pmClosed
CWE (AF) AMBALA
HQ CWE (AF) Ambala Ambala Cantt-133001
PROVN OF TRANSFORMER AND SUB-STATION FOR HT SUPPLY AT IOCL PREMISES AT AF STN AMBALA UNDER GE (AF) AMBALA
2023_MES_603293_1
CWE/AF AMB/AMB-07/2023-24
Open Tender
Miscellaneous Works
Item Rate
180 days
AMBALA CANTT
For MES enlisted contractor Class C Category b ii and for un-enlisted contractor refer NIT
7 documents required · 7 mandatory
₹1,000
GE (AF) AMBALA
₹1.4 L
Yes
6 Nov 2023
14 Jun 2023
28 Sept 2023
30 Jun 2023
26 Sept 2023
12 Sept 2023
20 Jun 2023 - 30 Jun 2023
Amount
Surface excavation not exceeding 30cm deep and averaging 15cm deep and getting out in soft/loose type soil complete all as specified & directed.
Add or deduct from item 1 here-in-above for every 3 cm or part thereof above or below 15 cm average depth in soft/loose type of soil, complete all as specified & directed.
Excavating over areas, not exceeding 1.5 mtr deep and getting out in soft/ loose type soil complete all as specified & directed.
Returning, filling in including spreading leveling watering and well ramming in layers not exceeding 25 cm thick each in soft/loose type soil complete all as specified & directed.
Removal of excavated soil to a distance not exceeding 50 mtr & depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified & directed.
Spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick each complete all as specified & directed Note :- Soil obtained from excavation under respective items shall be used for filling under this item.
M&L consolidated hardcore of broken stone or boulders, gauge not exceeding 63mm, deposited, spread and leveled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified & directed
M&L formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished flat surfaces of concrete complete all as specified & directed.
M&L formwork to sides of pillars, posts, struts, piers, columns & stanchions; square, circular rectangular on plan or polygonal in shape for rough finished flat surfaces of concrete complete all as specified & directed.
M&L formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for rough finished flat surfaces of concrete complete all as specified & directed.
M&L formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) for rough finished flat surfaces of concrete complete all as specified & directed.
M&L formwork to chullah hoods, chajjas, troughs and similar items including edges for rough finished flat surfaces of concrete complete all as specified & directed
M&L brick work with flyash burnt bricks (IS-13757), old size, Designation 75, straight or curved on plan exceeding 6mtr mean radius, built in cement mortar 1:6 complete all as specified & directed. Note: The work shall be executed above and/or below the ground level without any extra cost.
M&L reinforced cement concrete (RCC) M-25, design mix, using 20mm graded mechanically crushed stone aggregate as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified & directed.
M&L reinforced cement concrete (RCC) M-25, design mix, using 20mm graded mechanically crushed stone aggregate as in columns, pillars, piers, posts and struts complete all as specified & directed.
M&L reinforced cement concrete (RCC) M-25, design mix, using 20mm graded mechanically crushed stone aggregate as in beams, cantilevers, bressummers, lintels over 1.5mtr span complete all as specified & directed.
M&L reinforced cement concrete (RCC) M-25, design mix, using 20mm graded mechanically crushed stone aggregate as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified & directed.
M&L reinforced cement concrete (RCC) M-25, design mix, using 20mm graded mechanically crushed stone aggregate as in chajjas etc. & similar items complete all as specified & directed.
M&L mild steel TMT bars 10mm dia and over, Fe500/Fe500D grade confirming to IS-1786, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified & directed.
M&L mild steel TMT bars 6mm to 8mm dia, Fe500/Fe500D grade confirming to IS-1786, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified & directed.
M&L mild steel TMT bars 6mm dia and over upto & inculding 10mm dia, Fe500/Fe500D grade confirming to IS-1786, cut to length cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips as in stirrups, spacer & binders complete all as specified & directed.
M&L plain cement concrete(PCC) 1:4:8, type D2, using 40mm graded mechanically crushed stone aggregate as in foundation, filling and mass concrete complete all as specified & directed.
M&L 100 mm thick plain cement concrete(PCC) 1:2:4, type-B2 using 40 mm graded mechanically crushed stone aggregate as in ramp including finishing the concrete surface even and fair without using extra cement with chequered finish complete all as specified & directed. Note: Necessary formwork if required included in quoted rates.
M&L 100 mm thick PCC (1:4:8) type D2, using 40 mm graded mechanically crushed stone aggregate as in sub base to receive the topping layer complete all as specified & directed.
M&L rendering 15mm thick in cement mortar 1:6 on fair faces of brick masonry or concrete surfaces of walls, finished even and smooth without using extra cement complete all as specified & directed.
M&L rendering 15mm thick in cement mortar 1:4 on stone masonry or surface other than fair face of brick work masonry of wall, finished even and smooth without using extra cement complete all as specified & directed.
M&L machine cut kota stone tile of size 550mm x 550mm, 20mm to 22mm thick as in flooring, laid over & including 20 mm thick screed bed in cement mortar 1:4, and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified & directed.
M&L rendering 5mm thick in cement mortar 1:3 on concrete surfaces of ceiling/soffits, finishing the surface even and smooth without using extra cement complete all as specified & directed
M&L preparation of newly plastered surfaces of walls and applying three coats of white lime wash complete all as specified & directed
M&L preparation of newly plastered surfaces of ceiling / soffits and applying two coats of white lime wash complete all as specified & directed.
M&L preparation of newly plastered surfaces of wall and applying two coat exterior acrylic emulsion paint over & including one coat of alkali resistant primer complete all as specified & directed. Note: The finishing shall be executed in Camouflaging Pattern as decided by Engineer-in-charge without any extra cost to department.
M&L Atactic Polypropylene Polymeric(APP) water proofing treatement to roof, at any height, using membrane minimum 3 mm thick and weighting not less than 3.0 kg per sqm, black finish reinforced with non-woven polyster matt (Weight not less than 150 gram per Sqm), with properties of high penetration and centre core consisting of 90 micron, high molecular high density polyethylene (HMHDPE) film consisting of five layers with thermo fusible finish laid by force application after applying compatible bitumen primer at the rate of 0.40 litre per Sqm, torching over laps with a propane or butane gas torch with a over lap of 100 mm at the side on transverse direction and 150 mm at the ends on longitudinal direction and sealing including a tack coat of hot blown bitumen 85/25 @ 1.2 Kg per Sqm below APP complete all as specified & directed .
S&F factory made Box type steel window, double shutter(inside & outside), glazed and wire gauzed with side hung shutters including box type hinges, steel handles fabricated type for each leaf duly welded, mild steel barrel tower bolts 150mm size (02 Nos for each leaf) duly welded, complete with glazing bars dovetailed or welded including MS fillets, including supply & fixing of 4mm thick sheet glass, GI wire cloth 0.56mm nominal dia of wire and average width of aperture 1.00mm & MS grill of 8mm squre bar complete all as specified & directed. Notes: - (i) Windows shall be fabricated as per drawing No. TD-219 Sh 1/3 to 3/3 and these drgs may be referred from GE office or from the office of CWE (AF) Ambala. The window having nomenclature "XFW3" in drawing shall be executed at site. In case of any dispute direction of GE shall be final & binding. (ii) Glazing, Wire cloth, MS grill, Painting etc. are included in quoted rates and nothing extra shall be paid for window, apart from this item. (iii) Window shall be painted with two coats of synthetic enamel paint over & including one shop coat red oxide primer. (iv) Double shutter meant for providing glazed shutter as well as wire gauged shutter on outside & inside of the frame respectively. Both the shutters shall be measured as one unit. (v)Steel window shall comply with IS 1038-1983 &. Rolled steel sections for fabrication shall conform to IS 7452-1990
S&F gear operated type steel rolling shutters 1.25 mm thick lath confirming to IS 6248 upto date, with bevel gear box and crank handle including ball bearing & satety lever lock 4 lever as specified including top cover, anchoring rod, pipe shaft, hood cover 1mm thick, curtain, hold fast stopper, square bar guide channel, bracket plate, lock plate, handle, sliding lock, pulling hook, hasp and staple including one shop coat of primer; erected in position as indicated complete all as specified & directed.
M&L 75mm thick PCC 1:3:6, type C-1, using 20mm graded mechanically crushed stone aggregate as in plinth protection finished even and smooth without using extra cement with & including 10mm wide, 30mm deep joints at the rate of 3.00 mtr centre to centre and at every turning & filling the joints with bitumen & sand mixture complete all as specified & directed. Notes :- (i) The unit rate quoted shall be deemed to include for providing the concrete in alternate bays not exceeding 3 Mtrs length. (ii) 30 mm deep joints between the bays shall be provided which shall be filled with mastic filling with hot bitumen 85/25 grade and 1:2 mix volume. (iii) Plinth protection shall be of width as directed and shall be laid to slope of 1:3
M&L for laying of polythene film, 50 micron thick laid over & including one coat of bitumen primer @ 0.30 to 0.50 Kg per sqm complete all as specified & directed.
Excavation in trenches, not exceeding 1.5mtr wide and not exceeding 1.5mtr in depth; for foundation, laying pipes/cables etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10sqm on plan & not exceeding 1.5mtr in depth and getting out, in soft/loose type soil complete all as specified & directed. Note: Wherever the work executed for pipe lines, the bottom surface shall formed to required level & slope without any extra cost to department.
Removal of excavated soil to a distance exceeding 250 mtr but not exceeding 500 mtr & depositing where directed complete all as specified & directed.
M&L plain Cement concrete(PCC) 1:3:6 type C2 (using 40mm graded mechanically crushed stone aggregate) as in foundations, filling and mass concrete complete all as specified & directed
M&L plain cement concrete(PCC) 1:2:4 type B1 using 20 mm graded mechanically crushed stone aggregate as in surface channels and drains complete all as specified & directed. Note: Any necessary formwork wherever required shall deemed to be included in quoted rates.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement including forms, moulds, mitred/stopped ends etc., complete all as specified & directed.
Add or deduct in quoted rates of item 41 here-in-above for each 25 mm girth or part thereof over or under 30 cm inner girth in cement concrete, using extra cement including forms, moulds, mitred/stopped ends etc., complete all as specified and directed.
M&L Brick work with sub class B, burnt clay bricks of old size, designation 75, straight or curved on plan to any radius in half brick thick wall, built in cement mortar 1:4 complete all as specified & directed.
M&L Brick work with sub class B, burnt clay bricks of old size, designation 75, straight or curved on plan exceeding 6 mtr mean radius, built in cement mortar 1:6 complete all as specified & directed.
M&L plain cement concrete(PCC) 1:2:4, type B-0, using 12.5 mm graded mechanically crushed stone aggregates as in lintels upto 1.5mtr clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating including necessary formwork to complete all as specified & directed.
M&L flush pointing to brick walls in cement mortar 1:3 including racking out the joints complete all as specified & directed.
Supply, installation, commissioning & testing of transformer step down, 11 KV/433 volt as per IS-1180 Part 1 2014 including amendment No. 1,2,3 & 4, energy efficient level -II, Oil Natural Air Natural (ONAN) Immersed. Indoor type, copper wound, suitable for AC, three phase, 4 wire, 50 Hz system of capacity 800 KVA, oil immersed having Vector group DYN-11, naturally cooled type, complete with and including first filling of transformer oil, delta connection on HT side, star connection on LT side, manually operated, off-load tap changer on HT side to vary secondary voltage to (+)(-) 7.5% in seven steps of 2.5% each in each step, including control wiring to VCB with suitable size cable, cable end box at HT & LT side, LT side cable box shall also be fitted with suitable size of cable glands for making connections with all accessories and under mentioned fittings complete all as specified & directed:- (a) Rating plate and terminal marking plate. (b) Two earthing terminals for body earthing and two additional for neutral brought out on a bushing (c ) Lifting lugs (d) OIL DRAIN VALVE WITH PLUG & OIL FILTER VALVE WITH PLUG (e) CONSERVATOR WITH OIL FILLING HOLE WITH CAP, Silica gel breather (f) Oil level indicator with minimum and maximum marking (g) Cooling Radiator (h) Thermometer pocket (i) Air release plug (j) Explosion vent
(k) Oil temperature Indicator –6” Dial type (Having Contacts for Alarm & Trip) (l) Winding temperature Indicator (Having Contacts for Alarm & Trip) (m) BUCHHOLZ RELAY (Double Float Type) (Having Contacts for Alarm & Trip) (n) Any other fittings as recommended by the manufacturer of effecient functioning of the transformer. Notes:- (i) The transformer shall be tested as per IS for all routine tests in the factory premises in the presence of rep of Accepting Officer on the receipt of request from the contractor through GE in addition to routine tests . The Transformer shall be tested by SEI/EI/AEI beore commissing as & when requested by contractor. All necessary arrangements i.e. co-ordination with the manufacturer & testing officer, arranging equipments and material to facilitate testing at the manufacturer’s premises etc. shall be borne by the contractor.
Supply, fixing, commisioning & testing Servo Motor Operated Line Voltage Correctors (SVC)/servo controlled voltage stablizers indoor type suitable for both balanced & unbalanced supply & load of capacity 750 KVA copper bound - Oil Cooled (first filling of oil is included) Input Voltage Range 1 Φ = 175 volt - 280 volt, 3 Φ = 300 volt - 480 volt, Output Voltage Range 1 Φ = 240 volt + 1% volt , 3 Φ = 415 volt + 1% volt, efficiency more than 98 %, response time less than 10 milisecond with under mentioned features complete all as specified & directed:- a) Electronic control circuit b) Low Voltage Cutoff c) High Voltage Cutoff d) Single Phase Preventor e) Over Load & Short Circuit Trip Facility f) Servo By Pass Switch Notes:- (i) The Voltage corrector/stablizer shall be tested in the factory premises in the presence of rep of Accepting Officer on the receipt of request from the contractor through GE . (ii) The Voltage corrector/stablizer shall be tested by SEI/EI/AEI before commissing as & when requested by contractor. (iii) All necessary arrangements i.e. co-ordination with the manufacturer & testing officer, arranging equipments and material to facilitate testing at the manufacturer’s premises etc. shall be borne by the contractor.
Notes for BOQ item No. 49 & 50 :- (i) The drawings in respect of VCB shall be approved by Accepting Officer through GE and as & when requested by contractor before placing order to manufacturer (ii) VCB shall be tested by representative of Accepting Officer at factory premises before dispatch as & when requested by contractor. (iii) The testing & commissing of the VCB shall be carried out in presence of Electrical Inspector as & when requested by contractor. (iv) The cost of all above factors deemed to be included in quoted rates.
M&L earthing complete with using GI strip 50mm x 6mm as earth lead and GI pipe earth electrode 80mm bore medium grade, 3.8 mtr in long with threaded cap on top. Pipe shall be welded with 50mm x 10mm flat iron 'L' shape of size 114mm in length from pipe at depth of 150mm from top of the pipe. Pipe electrode shall be cut tapered at the bottom and provided with 12mm holes on two faces at 75mm interval on centre to centre. The first hole shall be at 700mm below the welded flat and last hole shall be at the bottom end of the pipe. The excavation for earthing to be made with size 1100mm x 1100mm and 925mm in depth from ground level(GL). Further excavation in depth shall be 300mm x 300mm and depth 3.125 mtr below 925mm from GL (total depth in earthing shall be 4.05 mtr). The electrode shall be burried in the ground vertically with its top not less than 100mm below GL and its bottom at depth of 3.9 mtr. The layer of 150mm thick PCC 1:2:4 shall be laid at depth 830mm from GL. The earthing shall be filled with alternate layers of coke 450mm and common salt 150mm. The 50mm x 10mm GI Bracket (in 'C' shape used as earth busbar for interconnection) shall be grouted in brick walls with rag nuts and bolts at depth 80mm GL. The GI bracket shall minimum 8 holes for M14 bolts for interconnection with GI strip. The Earthing Pit chamber of internal size 600mm x 600mm shall be made with bricks work 1:4 from PCC layer of 75mm above GL. The earth pit chmaber shall have grooves for placing covers. The earth pit chamber shall have 6 mm thick MS chequered plate cover including 12mm round bar for handle with SS nut, bolts/washer etc as per drawing of IOCL and as per specification & direction of Engineer-in-charge in charge. Note : (i) The earth result should be less than 1.0 ohm and will be checked in the presence of Engineer-in-charge. (ii) The rate for GI strip 50mm x 6mm of Two Runs upto 7.5 mtr in length is incuded in quoted rate. (iii) Necessary Earth work, PCC, formwork, Brick work etc. shall included in quoted rates.
M&L earthing GI strip 50mm x 6mm on FRP insulator fixed on wall/MS sheet/floors/in trenches including connecting to earthing/test point, strip should be brazed/welded at each joint complete all as specified & directed.
Supply, laying, jointing & testing LT cable 1100 volts grade, stranded copper XLPE insulated PVC inner sheathed strip armoured confirming to IS 7098(part-I) upto date, heavy duty Aluminum conductor cross sectional area 150 Sqmm 1 core laid in trenches, ducts, through pipes, floor, or fixed on poles/wall complete all as specified & directed.
Supply, laying, jointing, testing & commissioning of HT XLPE cable(heavy duty), 11000 volts (earthed), insulated, screened, sound compacted aluminium conductor, screening with extruded semi conducting layers, insulation screening with copper tape covers laid up with PVC (ST-2), extruded inner sheathed GI strip armoured PVC (ST-2) out sheathed, ISI marked with IS-7098 Part II upto date, cross sectional area 120 Sqmm, 3 core, laid in trenches/ducts or fixed with along poles/ wall etc complete all as specified & directed. Notes: (i) Cable shall be of manufacturing date not earlier than Jun 2023. All the cable shall be embossed with year of manufacturing, meterage at every metre, in addition to its own standard markings as per IS i.e. Size, voltage etc. (ii) Excavation & earth work, sand cushioning, protection pipes, end termination joints & protection covers shall be measured and paid separately. (iii) No straight through joint shall be permitted in less than single drum length.
S&F cable jointing kit for 11 KV earthed grade cable, indoor type, end termination heat shrinkable type joints with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120sqmm to 185Sqmm complete all as specified & directed.
M&L Sand cushioning to cable with a layer of sand 8 cm deep before laying the cable and 15 cm deep after laying the cable (punned down to 18 cm depth after laying and stretching of cable ) complete all as specified & directed.
Supply & laying un-reinforced precast concrete cable cover , Class HV type-1, flat, size 300mmx180mmx40mm, laid flat for protection of cable , adjacent to each other, perpendicular to central axis of cable complete all as specified & directed.
M&L boring of holes under road, pavement, hardstanding for passing/crossing pipes/cables upto size 100mm dia/bore at suitable depth (not below than 1mtr) by trenchless technology using ultra sounding technique & Horizontal directional drilling (HDD) machine complete without damaging the surface and removing excavated soil to a distance not exceeding 50mtr complete all as specified & directed. Notes : Location of boring holes shall be decided by the Engineer-in-charge as per requirement, nothing extra shall be payable on account of variation in length of crossing of road etc. During boring soil strata may be changed, hence nothing extra shall be paid to the contractor for boring of holes through different strata/different type of soil. Pipe/Cable shall be measured & paid seperately.
M&L galvanized steel tubing 100 mm bore light garde (ISI marked) for protection of cable fixed to pole/walls or laid in floors/trenches, road crossing ducts with all necessary fittings and fixed with clamps, bolts, nuts and washers etc complete all as specified & directed.
Supply, laying, jointing & testing LT cable 1100 volts grade, stranded copper XLPE insulated PVC inner sheathed strip armoured confirming to IS 7098(part-I) upto date, heavy duty Aluminum conductor cross sectional area 300 Sqmm 1 core laid in trenches, ducts, through pipes, floor, or fixed on poles/wall complete all as specified & directed.
S&F LT panel weather proof Indoor type double door fabricated out of 2.00 mm thick CRCA sheet with epoxy powder coating of RAL-7035 (Siemens grey) shade with matt finish with seven tank pre treatment process.The panel shall be fabricated by CPRI approved manufacturer only.The panel shall be compartmentized designed totally enclosed , dust & vermin proof, confirming to degree of protection IP-55, gasket between all adjacent units and beneath all covers shall be provided to render the joint dust proof. All doors and covers shall be provided with cyllendrical panel locked and shall be fully gasketed with neoprene rubber and shall be lockable.The panel shall be provided with Copper bus bars of 1600 amp rating .The bus bars and interconnecting links shall be insulated with heat shrinkable PVC sleeve with RYB and black colour coding.The bus bar shall be supported on unbreakable,non hygroscopic, SMC insulated supports at sufficiently close interval to prevent bus bars sag and shall be housed in a dedicated compartment.The panel shall be prewired with FRLS PVC insulated coper conductors cables of suitable size properly tagged and secured. All joints and connection shall be done with galvanised or cadium plated high tensile nuts bolts and washers . The panel shall be provided with digital multifunction meter with cast resign CTs & RYB LED indicating lamps at incoming. The panel shall be provided with heavy duty steel cable glands of adequate size for incoming & all outgoing cables.The single line circuit diagram showing the arrangement of circuit inside the distribution board shall be provided inside the panel door and covered with transparent laminated plastic sheet. The panel shall be provided with manufacturer name plate, skull & bone danger notice board etc. The panel shall be provided with 04 numbers 50mm x 50mm x 6mm angle iron supports of not less than each 01 mtr height duly painted with anti corrosive black paint and grouted in PCC 1:3:6 at suitable depth at per site requirement. The overall size of the panel shall not be less than 1500mm x 450mm x 1500mm (LxDxH). The panel shall be provided with and including the following accessories complete all as specified & directed :
(A) Incomming (i) ACB 1250 Amps, 50kA, FP, 415 volts, adjustable type, manual draw out type - 01 No. (ii) Digital ampere meter three phase 0 Amps to 1250 Amps square type - 01 No. (iii) Digital volt meter three phase 0 volts to 500 volts square type - 01 No. (iv) Copper bus bar capacity 1600 Amps mounted on suitable insulators - 04 Nos. (v) Indicator lamp LED type RYB ( set of three) - 01 Set (B) Outgoing (i) ACB 1250 Amps, 50kA, FP, 415 volts, adjustable type, manual draw out type - 02 Nos. (One standby) (ii) Microprocessor based three phase electroninc tamper proof CT operated energy meter for LT supply with optical communication port , accuracy class 0.5 voltage 3 X 240 volt -/5 A with CT of suitable ratio 1200/5 Notes: (i) The cost of Earthwork in any type of soil, fair finished formwork (if any) & PCC blocks/foundation of size as directed by Engineer-in-charge deemed to be included in quoted rates. (ii) Layout diagram of LT panel shall be produced by contractor for approval of Accepting Officer through GE before placing order to manufacturer and panel shall be brought at site as per approved drawing. The cost of same is deemed to be included quoted rates.
M&L concealed point wiring with Flame retardant low smoke(FRLS), PVC insulated unsheathed cable 1.5 sqmm with multistranded copper conductor, 1100 volt, drawn through in and including non metallic rigid PVC conduit not less than 20mm bore medium grade, with conduit fittings including all tees, bell mouth tube ends and fixing accessories such as couplers, saddles, pipe hooks etc concealed in wall/ceiling/roof etc with provision of new sunken type pressed steel/welded MS terminal boxes of not less than 1.6mm wall thickness(duly painted with two coat of anticorrosive paint outside & aluminium paint inside) with decorative laminated sheet top cover 3mm thick including Flame retardant low smoke(FRLS), PVC insulated, unsheathed, multistranded copper earth conductor 1.5 sqmm connected to common earth and earth dolly for one light point, ceiling fan/exhaust fan point controlled by one way switch 5/6 amp complete all as specified & directed.
Description all as per BOQ item No. 62.00 here-in-above but for one socket outlet point 5/6 amp controlled by one way switch on the independent board.
M&L concealed point wiring with Flame retardant low smoke(FRLS), PVC insulated unsheathed cable 2.5 sqmm with multistranded copper conductor, 1100 volt, drawn through in and including non metallic rigid PVC conduit not less than 25mm bore medium grade, with conduit fittings including all tees, bell mouth tube ends and fixing accessories such as couplers, saddles, pipe hooks etc concealed in wall/ceiling/roof etc with provision of new sunken type pressed steel/welded MS terminal boxes of not less than 1.6mm wall thickness(duly painted with two coat of anticorrosive paint outside & aluminium paint inside) with decorative laminated sheet top cover 3mm thick including Flame retardant low smoke(FRLS), PVC insulated, unsheathed, multistranded copper earth conductor 2.5 sqmm connected to common earth and earth dolly for one socket outlet point 15/16 amp controlled by one way switch on the independent board complete all as specified & directed. Notes for BOQ item No. 62 to 64.00 :- (i) S&F of Switches, socket outlets, bell pushes and fan regulators etc. shall be measured and paid for separately. (ii) Rate quoted shall be inclusive of cutting chases in wall and making good in cement mortar 1:3 & finishing the disturbed surfaces to match with the existing surfaces.
S&F switch piano, flush type, 5/6 amp, single pole, one way complete all as specified & directed.
S&F switch piano, flush type, 15/16 amp, single pole, one way complete all as specified & directed.
S&F socket outlet, flush type, 2 in 1, 3 pin, 5/6 Amp, complete all as specified & directed.
S&F socket outlet, flush type, 2 in 1, 3 pin 5/6 Amp and 15/16 Amp, complete all as specified & directed.
S&F ceiling rose, surface bakelite 3 terminals, isolated body complete all as specified & directed.
S&F LED lights fitting 1 x 18 watt, 220 volt, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified & directed.
S&F new generation energy saving LED light fitting 1x 9 watt/10 watt bulkhead luminaires made of plastic housing with opal diffuser including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified & directed.
S&F heavy duty, exhaust fan, single phase, 230/240 volt, 380mm sweep, steel body, 1400 RPM, totally enclosed heavy duty motor with copper winding including mounting brackets fixing on frame including S&F MS sheet 1.00mm thick as louver shutter for exhaust fan with all accessories fixed on wall and making connetions with twisted copper flexible wire 23/0.0076mm complete all as specified & directed.
S&F sheet metal enclosure distribution board, 230 volt, single pole and neutral, IP 43 protection, with 200 Amps rated copper busbar and neutral link, 4 way, double door type flushed inside the wall including making good the disturbed surfaces complete all as specified & directed.
S&F MCB, single pole & neutral, 40 Amp, C curve, 10 kA capacity, 240 volts complete all as specified & directed.
S&F MCB, single pole, 5 to 32 Amp, C curve, 10 kA capacity, 240 volts complete all as specified & directed.
M&L concealed sub main wiring with two single core FRLS, PVC insulated, unsheathed cable,1100 volts grade, 4 sqmm nominal cross sectional area stranded copper conductor and one single core green FRLS, PVC insulated, unsheathed 4 sqmm stranded copper conductor as earth continuity cable drawn through in & including non metallic rigid PVC conduit heavy grade not less than 25mm bore including accessories concealed in wall/floors/roof etc including cutting chases in wall/ceiling and making good the disturbed surfaces to match with existing surface complete all as specified & directed. Note :- Two runs of 4 sqmm cable alongwith one run of 4 sqmm cable as earth wire alongwith conduit shall be measured as one unit. The cost of cutting of chases wherever required shall deemed to included in quoted rates.
M&L earthing complete with galvanized steel earth plate electrode 60cm X 60cm, 6mm thick buried directly vertically in ground to depth not less than 2.25 mtr below ground level, with top edge of earth plate not less than 1.5 mtr below ground level surrounded from all sides by 15cm thick packed layer of Charcoal dust & common salt filled in alternate layers and electrode connected to GI earth lead wire 4.00mm dia upto 7.5mtr long by means of bolts, nuts, check nuts and washers of galvanized iron and connection to earthing test point & earth dolly and including watering pipe medium grade GI 20mm bore 1.5 mtr long & protection pipe light grade GI 15mm bore upto 7.5 mtr long, including wire mesh, funnel, lugs, salt, charcoal dust, excavation in soft/losse soil, returning filling & removal of surplus soil upto 50mtr, pit chamber shall be of PCC 1:3:6 type C1 using 20 mm graded mechnically crushed stone aggregates and pit cover slab 50mm thick shall be of Precast RCC 1:2:4 type B-1 using 20 mm graded mechnically crushed stone aggregates reinforced with XPM weighing not less than 4Kg/sqm including necessary form work complete all as shown in electrical plate No 3 of SSR part-I, including testing on completion at site complete all as specified & directed. Notes :- Any variation in length of earth lead and protection pipe of earth lead shall be adjusted through Deviation order. On testing if the earth resistance is not obtained, earthing will be generated at no extra cost ,till the desired earth resistance is obtained. The chamber shall be constructed atleast 1.5 mtr away from the earth electrode.
SAINI AND SAINI BUILDERS
Leo Air and Power Solution pvt Ltd.
Electromech Engineers
SHARMA ELECTRICAL ENGINEERS
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .