Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.8 LAccepted-AOC V P O SAROTARI TEHSIL BAROH DISTRICT KANGRA PIN 176037 HP | KANGRA | HIMACHAL PRADESH | 176037 | L1 | Accepted-AOC Accepted being lowest quoted rate | |
| 2 | L2₹21.6 L+₹3.5 L (19.0%)Rejected-AOC 74 AJANTA COMMERCIAL CENTRE ASHRAM ROAD AHMEDABAD 380014 | AHMEDABAD | AHMEDABAD | GUJARAT | 380014 | L2 | Rejected-AOC Not accepted since higher quoted rate | |
| 3 | L3₹21.9 L+₹3.7 L (20.4%)Rejected-AOC 274 210 DAFNALA ROAD SHAHIBAUG AHMEDABAD GUJARAT 380009 | AHMADABAD | GUJARAT | 380009 | L3 | Rejected-AOC Not accepted since higher quoted rate | |
| 4 | L4₹22.0 L+₹3.8 L (21.1%)Rejected-AOC 200 NAVAGAM NAVAGAM TA SAYLA SURENDRA NAGAR GUJARAT 363430 | SURENDRANAGAR | GUJARAT | 363430 | L4 | Rejected-AOC Not accepted since higher quoted rate |
Tender Value
₹21.9 L
EMD Value
₹43,800
Closing Date
22 Jun 2020, 6:00 pmClosed
GE ARMY GANDHINAGAR
GE GANDHINAGAR PO BSF CAMPUS GANDHINAGAR 382045
REPAIR MAINTENANCE REPLACEMENT OF STREET LIGHT EXTERNAL LIGHTS WITH UG CABLE ELECTRIC WIRING WITH FITTINGS AND FIXTURES SUB MAIN WIRING DBS WITH EARTHING IN MD ACCN AT MIL STN GANDHINAGAR
2020_MES_344004_2
GE(A)/GNR/TOKEN/08 of 2020-21
Open Tender
Civil Works - Others
Item Rate
180 days
MIL STN GANDHINAGAR
AS PER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
Yes
GE ARMY GANDHINAGAR
₹43,800
Yes
8 Sept 2020
3 Jun 2020
24 Jun 2020
3 Jun 2020
22 Jun 2020
9 Jun 2020
3 Jun 2020 - 8 Jun 2020
Amount
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc or for shaft, wells, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layer not exc 25 cm with soil obtained from excavation all as specified and as directed.
M&L, for providing dry river sand as in sand cushioning to UG cable including punning gently all as directed. Note: Depth after punning shall be measured and paid.
Removing excavated material (Soil) not exc 50 mtr and depositing where directed at a level not exc. 1.5 m above the starting point all as specified and as directed.
Supply and laying, sub class old 'B' burnt bricks, size of brick 230x115x75mm, laid as cable protection cover complete all as specified and directed.
Supplying & laying, 10 Sqmm, 4 core cable, XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire heavy duty underground cable with aluminium multi stranded conductor, 1100 volt grade, laid in trenches/duct, passing through pipe/duct or fixed on pole and connecting and testing complete including taking down old unserviceable cable complete all as specified and directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed.
M&L for wiring with and including multistranded copper conductor 1.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLS cable 1100 Volts grade, ISI marked with valied CML number drawn in and including medium grade PVC casing and capping double lock type 32mm in size, fire resistant, ISI marked including with its fittings and fixtures such as tees, bends, elbows, junction boxes, etc. including multistranded copper conductor 1.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLS cable 1100 Volts grade, ISI marked with valied CML number as continuity earth wire and including pressed steel sunken concealed terminal box with 3mm thick industrial laminated sheet cover for mounting switches, sockets and fan regulators etc. complete all as specified and directed for the following :-
(a) One light/fan point controlled by one switch
(b) One light point controlled by two, 2- way switches.
(c) One 3 pin, 5 Amps, socket outlet on the same board controlled by another switch.
(d) One multi pin 5 Amps, socket outlet on Independent board.
(e) One bell/ buzzer point controlled by one push buttons independent
M&L for wiring with and including multistranded copper conductor 2.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLS cable 1100 Volts grade, ISI marked with valied CML number drawn in and including medium grade PVC casing and capping double lock type 32mm in size, fire resistant, ISI marked including with its fittings and fixtures such as tees, bends, elbows, junction boxes, etc. including multistranded copper conductor 1.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLS cable 1100 Volts grade, ISI marked with valied CML number as continuity earth wire and including pressed steel sunken concealed terminal box with 3mm thick industrial laminated sheet cover for mounting switches, sockets and fan regulators etc. for one 3 pin, 15 Amps socket outlet point on independent board complete all as specified and directed.
S&F, in repair, lamp holder, PVC/Polycarbonate, with back plate suitable for batten fittings complete all as specified and directed
S&F, switch piano, flush button, single pole, one way, 5 Amps complete all as specified and directed as per make of Anchor/Vinay /Havells..
S&F, switch piano, flush button, single pole, one way 15 Amps complete all as specified and directed as per make of Anchor/Vinay /Havells.
S&F, switch flush type 5 Amps, single pole, two ways complete all as specified and directed as per make of Anchor/Vinay /Havells.
S&F, bell push, flush type 5 Amps complete all as specified and directed as per make of Anchor/Vinay /Havells.
S&F, bell, A.C. 230 Volts, single pole, Ding doll, complete all as specified and directed as per make of Anchor/Havells/Bajaj.
S&F, socket outlet, 2 in 1, 3 pin, 15 Amps and 5 Amps flush type complete all as specified and directed as per make of Anchor/Vinay /Havells.
S&F, socket outlet, 2 in 1, 3 pin, 5 Amps flush type complete all as specified and directed as per make of Anchor/Vinay /Havells.
S&F, in repair, MCB single pole, 6 to 32 Amp 240 volts with 'B' curve, fixed in sheet metal board including connecting complete all as specified and directed. Makes of Havells/Legrand/Schneider.
S&F, in repair, MCB single pole and neutral, 40 Amps, 240 volts with 'B' curve, fixed in sheet metal board including connecting complete all as specified and directed. Makes of Havells/Legrand/Schneider.
S&F, in repair, MCCB, triple pole and neutral, 25 KA, 63 Amps, 415 Volts including connecting complete all as specified and directed. Makes of Havells/Legrand/Schneider.
S&F, in repair, MCCB 125 Amps TP, 415 volts of breaking Capicity 25 KA including connecting complete all as specified and directed. Makes of Standard/Schneider/Havells.
S&F, in repair, MCCB 100 Amps TP, 415 volts of breaking Capicity 25 KA including connecting complete all as specified and directed. Makes of Standard/Schneider/Havells.
S&F, in repairs, sheet metal distribution board, SPN, 8 way 240 Volt, double door factory made and tested complete, protection class IP-42 suitable for mounting MCBs, isolator with 200 A tinned copper bus bar complete all as specified and directed
S&F, ceiling rose, 3 terminal , any shade, of PVC/Polycarbonate, isolated body complete all as specified and directed
S&F, in replacement, ceiling fan regulators, Electronic type, AC, 230 Volts complete all as specified and directed.
S&F, in repairs, sub-main wiring with 2 single core, 4 Sqmm PVC insulated, unsheathed, 1100 Volts grade, FRLS, copper multi stranded conductor drawn in and including PVC concealed conduit including drawing one run of PVC insulated, unsheathed, 1100 Volts grade, FRLS, copper conductor multi stranded, 4 Sqmm size as continuous earth wire drawn through and connected to main switch/DB and testing on completion complete all as specified and directed. Note: (i) 2 runs of main conductor, one run of earth conductor and one run of PVC casing and caping shall be measured as one unit length. (ii) Rates quoted shall be inclusive of cutting wall for concelling conduit and making good the same in cement mortal 1:3.
S&F, in repair, LED light fitting, batten type, housed in extruded from powder coated aluminium, 20 watt connecting with flexible three core copper conductor cable of suitable size and testing complete all as specified and directed as per Make of Wipro/Havells/Bajaj.
S&F, in repair, LED light fitting, batten type, 10 watt connecting with flexible three core copper conductor cable of suitable size and testing complete all as specified and directed as per Make of Wipro/Havells/Bajaj.
S&F, in repair, LED bulk head, 10 watt connecting with flexible three core copper conductor cable of suitable size and testing complete all as specified and directed as per Make of Havells/Bajaj/Crompton.
S&F, in repair, LED type, building security light fittings, IP-66 protection, 25W, Pressure die cast aluminium housing with toughned glass & individual LED's with secondary optics including taking out old unsv fitting of any type complete all as specified and directed as per Make of Havells/Bajaj/Eveready.
S&F, in repair, LED type street light fittings, IP-66, 60 Watt, Pressure die cast aluminium housing with toughned glass & individual LEDs with secondary optics complete including connecting and testing complete all as specified and directed. Make as per Wipro/Havells/Eveready.
S&F, in repair, LED type street light fittings, IP-66, 45 Watt, Pressure die cast aluminium housing with toughned glass & individual LEDs with secondary optics complete including connecting and testing complete all as specified and directed. Make as per Wipro/Havells/Eveready.
S&F, in repair, LED type street light fittings, IP-66, 30 Watt, Pressure die cast aluminium housing with toughned glass & individual LEDs with secondary optics complete including connecting and testing complete all as specified and directed. Make as per Wipro/Havells/Eveready.
S&F, in repairs, bracket made out of light grade, Galvanised steel tube, 40mm bore, 1.2 Mtr length, bent to 120 degree for fixing street light fitting at the top, fixed to pole with necessary clamps made out of FI 40mm x 4mm with nuts & bolts including preparation of steel surfaces & apply two coat of synthetic enamel paint over red oxide primer complete all as specified and directed.
S&F, in repair, PVC insulated and PVC sheathed copper conductor cable of size 1.5 Sqmm, 3 core, 1100 volts grade, multistranded, passing throuth existing pipe, fixed on pole/wall from juntion box to street light fitting complete all as specified and directed. Make of Havells/Polycab/Finolex.
S&F, in repair, Digital time switch, Electro mechnical type with programming using captive segments with 24 hrs timing setting, AC 230 V, AC contactor, (relay) 230V, 40 Amps including 4 module wether proof cabinet IP-65 protection complete with electrical internal connection complete all as specified and directedas per make Legand/Schenider/Standard.
M&L, in repairs, earthing complete with galvanized steel earth plate electrode of 60 cm x 60 cm x 6mm thick buried directly in ground [earth pit not less than 2.25 metre deep below normal ground level] with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanized earth wire of 4mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No. 3 of MES SSR Part I all as specified and testing on completion including provision of earth lead protected by 15 mm dia light grade GI pipe & watering pipe shall be 20 mm bore medium grade GI pipe including all excavation and earth work in any type of soil, PCC pit with RCC cover, char coal, salt, funnel etc complete. Note : Rate quoted by tenderers shall be deemed to include for following provisions;-[i]. Excavation & earth work in any type of soil including removing of surplus material upto 50 M.[ii]. PCC 1:3:6 type C1 using 20mm graded stone aggregate in pit & 40mm thick precast RCC 1:2:4 type B1 cover 50x50 cm with 8mm TMT bars @ 10 cm C/C both ways with handles.[iii]. Main earthing lead from earth electrode to test point upto 7.5 mtr.[iv]. Funnel with watering pipe [GI pipe] 20mm bore [ISI marked] medium grade & copper lugs, charcoal & salt as reqd.[v]. GI protection pipe of size 15 mm bore light grade 7.5m.
S & F, in repair, Distribution Board Power line VTPN, 4 way, 415 volts, factory made powder coated, double door with neutral and earth link, including 4 pole MCCB 63 Amps rating for incoming supply and including 12 Nos single pole MCBs 6 Amp to 32 Amp for outgoing supply complete all as specified and directed as per make of Havells/Legrand/Schneider.
M&L for insulation resistance test report, as per performa given by the department, all equipment and worker (Electrician) for the said test will be provided by the contractor. After completion of the test reports will be submitted to the MES office complete all as specified and directed.
Electricals India
ALBA AC AND REF SERVICES
ARTI CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .