Loading…
Loading…
Tender Value
₹1.6 Cr
EMD Value
₹1.6 L
Closing Date
5 Aug 2026, 6:00 pm
Additional City Engineer (Ele. And Mech)
CONSTRUCTION OF BRTS BUS SHELTER ON UDHANA TEEN RASTA TO DINDOLI-KHARVASA (MADHURAM CIRCLE) IN SURAT CITY.(3RD ATTEMPT) (WORK-3)
324836
ACE (Ele./Mech) / TRAFFIC- BRTS PROJECT CELL /04/2026-27(Work No.03)
Open
Civil Works
Works
Surat
3 documents required · 3 mandatory
₹4,248
Commissioner, Surat Municipal Corporation
₹1.6 L
16 Jul 2026
16 Jul 2026
16 Jul 2026
5 Aug 2026
16 Jul 2026
e-Tender Notice No.:ACE(Ele./Mech.)/Traffic BRTS Pro. Cell/04/2026-27, Work No.3
NAME OF WORK :- CONSTRUCTION OF BRTS BUS SHELTER ON UDHANA TEEN RASTA TO DINDOLI-KHARVASA
(MADHURAM CIRCLE) IN SURAT CITY. (3rd Attempt)
Item Quantity Rate Unit
1 Providing and installing barricades including supplying, paiting
with flourscent paint/white paint and fixing CGI sheet 24 SWG of
required height as per site condition and M.S. angle of required
size to restain at 2.5 mt. c/c and dismantalling the same after
completion of work and allowing for movement of traffic as per 540.00 124.72 S.M.
drawing and as per instruction from engineer in charge
2 Reuse of the above barricades in item 1 for traffic safety purpose
without procuring new barricades. 540.00 28.32 S.M.
3 Provision of Solar Blinkers For barricading for limited period at
suitable locations as per requirement during the construction in
construction zone comprising of warning zone, approach
transition zone, working zone and terminal transition zone Etc. 10.00 248.00 Nos.
4 Demolition including stacking of serviceable materials with all
lead and lift. (i) RCC Work 10.00 1110.75 C.M.
5 Demolition and disposal of unserviceable materials with all lead
and lift (ii) Unreinforced cement concrete
6 Demolition and disposal of unserviceable materials with all lead
and lift (i) Paver Block
7 Excavation for foundation includ.sorting out & stacking of useful
materials & disposing of the excavated stuff upto 50 mt. Lead &
all lift, watering etc. Comp. (A) Loose or Soft soil Executed With
8 Boring holes 3.5 mt.deep in ordinary soil ( for cast in situ piles) &
disposal of the surplus excavated soil as directed within a lead of
50 M. For following diameter of piles.
9 Providing & laying C.C 1:3:6 (1cement : 3 coarse sand : 6 Crushed
stone agg 20m.m Nominal size) &curing comp. excl. cost of form 56.00 3095.25 C.M.
work in :(a) foundation & Plinth
10 Providing & laying cement concrete 1:1.5:3 (1 cement:1.5 sand:3
graded stone agg. 20 mm nominal size)& curing comp.
Includ.cost of form work but exclu. Cost of reinforcement for
reinforced concrete work in : (A) Foundation, footing, Base of
columns and Mass concrete.
Item Quantity Rate Unit
11 Providing & laying ordinary cement con. 1:1.5:3
(1cement:1.5sand: 3 graded stone agg. 20 mm nominal size)
finishing smooth curing etc. comp. Incld. Cost of form work but
excl. Cost of reinforcement for R.C.C. Work in : Up to G.L./P.L. (B)
(1)Having c/s area up to 0.08s.mt 0.00 9102.61 C.M. -
(2) Having c/s area more than 0.08 sq. mt. & upto 0.12 sq.mt
(3) Having cross sectional area more than 0.12 sq. mt. 0.00 7086.88 C.M. -
12 Providing & fixing IS Mark TMT Bar FE 500D reinforcement for
R.C.C. work incl. bending, binding & placing in position etc. comp. 16550.00 77.29 Kg.
13 Filling available excavated earth (excluding rock) in trenches.
plinth, sides of foundations etc. in layers not exceeding 20 cm. in
depth consolidating each disposited layer by ramming and
14 Half brick masonry in common brunt clay building bricks having
crushing strength not less than 35 Kg/Sq.Cm. in Cement mortar
1:4 (1- Cement : 4 -coarse sand ) in foundation and plinth (C)Fly
15 Providing 20 mm thick double coat mala cement plaster on brick
/ concrete work for plastering comprising of base coat 12 mm
thick cement plaster in cement mortar (1 Cement : 4 coarse sand)
in rough finishing and 8 mm thick top coat of cement mortar 1:2 592.00 286.10 S.M.
(1 Cement : 2 Coarse sand) finished with trovel including
scaffolding curing etc. complete.
16 Providing and laying polished Kota stone slab flooring over 20mm
(Average) thick base of cement mortar 1:6 (1-cement : 6-coarse
sand) or L.M. 1.1.5 (1-Lime putty :1.5 - coarse sand) laid over and
jointed with grey cement slurry mixed with pigment to match the
shade of slab including rubbing and polishing etc. complete. (A)
17 Providing and laying chequered precast concrete tiles 22mm
thick with aggregate of sizes upto 6mm in floors treads of steps
and landing on 20mm thick bed of C.M. 1:6 (1 cement : 6 sand) or
L.M. 1:1.5 (1 Lime putty : 1.5 sand) jointed with neat cement
slurry with pigments to match the shade of the tiles.
18 Providing and fixing 40 mm thick polished granite stone slab of
approved colour and make for platform in ticket cabin area,
machine cut to required size with edges machine polished and
chamfered as directed. The granite slab shall be laid over cement
mortar bed (1:4) of average 20 mm thickness over prepared base,
properly aligned, levelled and jointed with matching shade
epoxy/cement slurry. The joints shall be neatly finished and the 20.00 6190.80 S.M.
top surface shall be properly cleaned and made ready for use.
The item shall include cutting, handling, laying, curing, polishing,
labour, materials and all incidental charges complete in all
respects as per directions of the Engineer-in-charge.
19 Steel work welded in built up sections, framed work including
cutting, hoisting, fixing in position and applying a priming coat of
red lead paint (A) in beams & joists channels angles, tees, flats
with connection plates or angle cleats as in main & cross
beams,hip & trussed purlins connected to common raffers & the
Item Quantity Rate Unit
20 Providing and Fixing Hollow steel Sections Framed Work including
Cutting, Hoisting, Welding & Fixing in position Purlin, Main Chord
etc. as per Engineer- in-charge.TATA / JINDAL / ASIAN Make.
21 Fabricating, supplying, cutting, bending, fixing and assembling
frames etc using aluminium sections of JINDAL/HINDALCO make
or equivalent of thickness and fixed to MS framing, concrete
members etc with S.S.screws in counter sunk/ S.S. rivets, S.S
washers, SS anchor bolts, cleats, hangers etc and other necessary
accessories and hardware complete as per detailed drawing and
design. (Only finished measurements will be paid for, M.S.
framing shall not be part of this item.) The rate shall include
micron annodising of approved shade. The sheet type will be 918.00 535.00 Kg.
finalised by the consultant. The rates shall be inclusive of rubber
gaskets and all other hardware. Cutting and making of framing
etc shall be done by experts. The rates shall be inclusive of all
mechanized tools, cutters, bending machine work, grinders etc.
22 Providing and fixing stainless steel ( Grade 304) railing made of
Hollow tubes, channels, plates etc., including welding, grinding,
buffing, polishing and making curvature (wherever required) and
fitting the same with necessary stainless steel nuts and bolts
complete, i/c fixing the railing with necessary accessories &
stainless steel dash fasteners , stainless steel bolts etc., of
required size, on the top of the floor or the side of waist slab with
suitable arrangement as per approval of Engineer-incharge, (for 450.00
payment purpose only weight of stainless steel members shall be
considered excluding fixing accessories such as nuts, bolts,
fasteners etc.).
23 Providing & fixing Aluminium Composite panel of alum decor,
Indobond & Flexibond make to all Sufaces 4mm thick in required
colours of exterior consisting of two layers of aluminium skins of
0.25mm thick sandwiching a thermo plastic core in continuous
lamination process with PVDF coating of exterior grades ensuring
long life colour and fungal resistance. Base frame work with
aluminium sections shall be fixed over the all surfaces, ACP shall 944.00 1310.98 S.M.
be fixed to the frame work as cladding it includes cost of labour
,Materials, accessories, adhesive, scaffolding, wastages,
transport, taxes, fixing into a neat finish in aesthetic point of
view, without any undulations in facias all complete as per
drawing and instruction of engineeer in-charge.
Item Quantity Rate Unit
24 Providing and fixing in position as per designs 10mm thick
toughened glass of required size with diamond polished edges of
Asahi, Modiguard make or equivalent. The glass shall be firmly
fixed to the base surface using structural silicon of Dow Corning
or Wacker make. The contractor shall ensure that the base
surface is thoroughly cleaned prior to fixing of glass and the 35.00 4082.44 S.M.
assembly shall be made completely water tight. The contractor
shall check for water tightness and provide a certificate for the
same. The work shall be executed to the complete satisfaction of
the Engineer in charge and the work area shall be made totally
clean on completion of the work.
25 Providing and fixing factory manufactured PUF (Polyurethane
Foam) insulated sandwich roof panels of 50 mm thickness having
pre-painted colour coated GI sheet of minimum 0.45 mm
thickness on both sides with injected rigid polyurethane foam
core of density not less than 40 ± 2 kg/m³, suitable for roofing
application. The panels shall be laid over MS purlins with proper
alignment and slope, fixed using self-drilling screws with EPDM
washers to ensure complete water tightness. The joints shall be
interlocked and sealed with approved sealant to prevent leakage.
The work shall include cutting to required size, lifting, placing,
fixing, finishing edges, ridge/side flashing where required and
making the entire roof assembly fully weatherproof. The
contractor shall ensure proper slope for drainage and provide
water tightness certificate after completion. The work shall be
executed to the complete satisfaction of the Engineer-in-charge.
26 Providing and fixing terracotta blocks of size 8" × 8" × 2.5" in
approved pattern using polymer modified adhesive / chemical
mortar system, properly aligned and levelled to form ventilated
screen wall of required height. The item shall include cutting, 3525.15 S.M.
alignment, temporary bracing, adhesive application, curing,
scaffolding and all labour, materials and incidental works
complete as per approved drawings and directions of the
Engineer-in-charge.
27 Providing and installing in position HDPE synthetic Fiber carry
rollers of 100mm dia as per the design drawings of the
Consultant. The rollers shall have seals which are with labyrinth
seal components, non-rubbing polymer seal and attached with
dust and water deflectors. The rollers shall be such that they shall
have good rolling during impact and shall not damage the body of
the bus nor shall get damaged during impact and shall act as a
protecting mechanism for the bus and the surface of the bus
shelter. The installation of the rollers shall be as per the 140.00 929.00 Nos.
instructions of the manufacturers. Samples shall be approved
prior to installation. Roller shafts shall be made of stainless steel
and multi labyrinth seals shall be filled with high grade lubricants.
Item Quantity Rate Unit
28 Providing & applying two coats of weather shield max paint (3
coats may be required in case of darker colours.)of ICI Dulux or
Apex Ultima of Asian Paint including applying exterior acrylic
primer coat as per manufacturers specification and directions in
shade and colour approved by architects, on exterior surfaces of
the building including scaffolding, preparing the surface,
watering, curing etc. complete and as directed by the architects
and manufacturers.
Surface Preparation :
surface is thoroughly clean, dry and free from all loose dirt, chalk,
grease, fungi, algae and flaking paint. This can be achieved by brushing
with a wire/ stiff coir brush, followed by water jetting if required. Fill
up all minor cracks and defects with white cement and sand mixture in
the ratio 1:3. For application on previously painted wall, previous
coatings of paint must be thoroughly scraped off and Clean the surface
thoroughly using wire brushes.
Apply a liberal coat of exterior acrylic primer and allow it to dry for 4-5
hours. Application of putty is not recommended.
Minimum 4-6 hours duration is required between each coat of weather
shield max paint
29 Applying Priming coat over new steel and other metal surface
after over and including preparing the surface by throughly
cleaning oil, grease dirt and other foreign matter and scoured 732.00 36.74 S.M.
with brushed fine steel wool, scrapers and sand paper with ready
mixed priming paint brushing red lead.
30 Painting two coat (excluding priming coat) on new steel and
other metal surface with synthetic enemal paint, burshing to give
an even shade including cleaning the surface of all dirt, dust and
other foreign matters.
Total Civil Work
ELECTRIFICATION WORK
Internal Wiring & Light Fixture
31 Point wiring for Light / Bell with 2-1.5 sq.mm & earth wire of
sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC
insulated multi strand copper wires up to 10 mtr length , in below
type of pipe erected with 6A Modular type switch / bell push &
accessories and earth continuity of following type, erected on
PVC / Metallic/Wooden box, single mounting base frame
covered with textured/metallic/white front plate modules erected
on / in wall / ceiling as per pipe erected, with necessary Lamp
holder/ceiling rose / H.D.Connector as directed. (f) with medium
class Rigid PVC pipe and accessories erected concealed in
wall/ceiling complete Cat. III
Item Quantity Rate Unit
32 Point wiring for Individual Plug with & earth wire of 1.5 sq.mm
(Green) both are of ISI marked 1.1 KV grade FRLS PVC
insulated multi strand copper wires up to 10 mtr length, in below
type of pipe erected complete with Modular type switch & 5 pin
Plug erected on PVC / Metallic/Wooden box covered with
appropriate front plate modules erected on / in wall / ceiling as per
pipe erected with following type of accessories.[I] For 6A Plug
and 6 a switch with 2-1.5 sq.mm Cu. Wire from nearby 20.00 510.05 Pt.
switchboard/mcb db board.(f) with medium class Rigid PVC
pipe and accessories erected concealed in wall/ceiling
complete Cat. III
33 Point wiring for Individual Plug with & earth wire of 1.5 sq.mm
(Green) both are of ISI marked 1.1 KV grade FRLS PVC
insulated multi strand copper wires up to 10 mtr length, in below
type of pipe erected complete with Modular type switch & 5 pin
Plug erected on PVC / Metallic/Wooden box covered with
appropriate front plate modules erected on / in wall / ceiling as per 10.00 745.38 Pt.
pipe erected with following type of accessories.[II] For 16A Plug
and 16 amp switch with 2-2.5 sq.mm Cu. Wire from mcb db
board.(f) with medium class Rigid PVC pipe and accessories
erected concealed in wall/ceiling complete Cat. III
34 Wiring for the UPS / Comp. / Raw Power outlet with 2 nos. of
250 volts single phase and neutral 16 amps switched socket
outlet with 4 sq mm x 3 core FRLS Round flexible copper
conductor 1100 volts grade wires of approved make in
concealed or surface mounted Prelaid 25 mm dia medium guage
PVC Conduit / Race ways including providing and fixing of 2 no.s
of 16 amps 5 pin switch socket outlet of approved quality colour 20.00 1333.20 Nos
make & design in 2 mm thick GI box and earthing of fixtures
and the outlet box . ( Maximum 2 nos. of Plugs can be looped in
35 Providing following type of Modular Type Accessories mounted
with PVC / metallic/Wooden box, single mounting base frame
covered with textured / metallic/white front plate , modules
erected with necessary connections as per site situation directed
by Engineer In charge. (4) TV Co-axial Socket outlet Cat. III
36 Providing & erecting Switch board for Computer or electric
apparatus consisting of following modular type accessories
mounted with PVC / Metallic concealed/open box with single
mounting base frame covered with textured/metallic /white front
plate,modules erected with necessary connections as directed.
1 no. 6A/16A universal plug-switch combined. 10.00 1133.22 Each
3 nos. 6A Switch
3 nos. 6A 5 pin Plug Cat.III
37 Supplying & erecting approved make LAN cable of following size
in existing pipe as per direction [C] CAT -
38 Providing and fixing 350 x 350 x 40 mm deep 2 mm thick GI
sheet junction box including providing 3 mm thick stainless steel 30.00 914.05 Nos
cover as per specification.
Item Quantity Rate Unit
39 Supplying and erecting LED street light / Flood light fittings with
High power White LEDs wattage of 3 Watt and above assembled
on single MCPCB, efficiency more than 130 lm/w and corrosion
free High pressure die cast aluminum housing with smooth finish
powder coated and heat sink extruded aluminium with diffuser
and Polycarbonate optics/ lenses, with toughened glass with
company mark/name engraved or embossed 160 to 270 V,Power
Factor more than 0.95, THD < 10 %, CCT 3000 K to
5700K,Uniformity ratio >0.45, Luminaire efficacy>
lumens/watt . LED driver efficiency > 85 %.( fittings required LM-
79 & LM-80 certificates)(NOTE: Below description have shown 20.00 3345.12 Each
ranges of Wattage capacity of LED fittings.The Engineer incharge
may select any wattage capacity between the ranges shown.) (A)
Street Light (IP-65), Surge protection -4KV integral and ,Light
must have 440VAC line supply with over-voltage protection.
(i) above 36 to 48 watts Cat-lll
40 Supplying and erecting Street light pole bracket comprising main
B Class GI pipe of 4.2 cm/require outside dia. complete with
suitable B Class G.I. sleeve tubing of approx. 45cms.length and
suitable for 76.5mm/80mm/require size of pole top having nuts
and bolts for fixing the brackets and having spread of 0.5 mtr.
Length with 110 deg.with vertical plane and suitable welded
stiffener reducer and nipple with check nut complete painted with 20.00 491.87 Each
one coat.of Red oxide / PU base primer and two coats of
Aluminium / PU paint. paint with following nos of arms. [A] Single
Arm bracket 0.5 Mtr
41 Supplying and erecting approved make Bracket fan of 230 volt,
A.C. 50 Cy/s., 400/450 mm sweep complete erected on wall or
with lead Cores and connections complete. Cat.II
42 Supplying and erecting LED indoor fittings with LEDs of wattage
0.2 Watt to 0.5 Watt assembled on single MCPCB, with housing
used as a heat sink shall be made of thick sheet Steel conforming
to IS: 513/CRCA/aluminium pressure die cast powder coated
and high U.V. & corrosion resistance with diffuser housed in
aluminium casted body with company mark/name
160V to 270V,Power Factor more than 0.9, THD < 15 %, CCT
3000 K to 6500K, Luminaire efficacy> 85 lumens/watt , LED
driver efficiency > 85 % ( fitting required LM-79 & LM-80
Certificates)(NOTE: Below description have shown ranges of
Wattage capacity of LED fittings.The Engineer incharge may 80.00 758.51 Ea.
select any wattage capacity between the ranges shown.) (A)
Square/ Circular shaped Surface/Recessed Mount Downlight
with provision for spring loaded mounting clips
complete.IP65 (iv) 22-24 watts, Surge-2 KV Cat-III
Item Quantity Rate Unit
43 Supplying and erecting LED indoor fittings with LEDs of wattage
0.2 Watt to 0.5 Watt assembled on single MCPCB, with housing
used as a heat sink shall be made of thick sheet Steel conforming
to IS: 513/CRCA/ aluminium die cast powder coated and high
U.V. & corrosion resistance with diffuser with company
mark/name 120 to 300 V,Power Factor more than 0.9, THD <
%, CCT 3000 K to 6500K, Luminaire efficacy> 85 lumens/watt
,LED efficiency110 lumens/watt LED driver efficiency > 85 %
CREE / OSRAM / PHILIPS Lumileds / NICHIA / 80.00 112.11 Each
SEOUL/Bridgelux make LED used for luminaire. ( fitting required
LM-79 & LM-80 Certificates)(NOTE: Below description have
shown ranges of Wattage capacity of LED fittings.The Engineer
incharge may select any wattage capacity between the ranges
shown.) (A) LED Lamps integral type,cool white with PC
diffuser suitable for B22 LAMP holder (b) 5 to 8 watts cat-III
LT Switchgear, Distribution Boards & LT Panel
44 Providing and erecting Miniature circuit breaker single pole 6A to
25A suitable to operate on 240 V A.C. system and having
breaking capacity 10 KA to be erected in existing box. confirming 30.00 112.11 Each
to IS 8828/1996 with ISI Mark Cat.III (for lighs + fans + Tv)
45 providing and erecting Approved make RCCBs conforming
to IS: 12640 and having sensitivity of 30 mA and Short
Circuit withstand capacity of 10 KA and suitable for
operation on single phase 240 V,50Hz. having
characteristic of quick action & tripping with all advance
feature & do not incorporate any electronic component. for 10.00 1969.50 Each
following Max. rating erected as directed (i) 25 Amps.DP
46 Providing & erecting 240 V MCB double pole switch for motor &
inductive load (C Curve) having 10 KA breaking capacity &
confirms to IS : 8828 in existing box having following capacity (A)
6 to 32 Amp. Cat.III (for AFSC)
47 Providing and erecting Sheet Steel powder coated MCB
distribution board - flush / surface mounted fitted with busbar,
neutral link, earth bar and DIN rail, Conforms to IS 8623-1 &
IEC 61439-1 & 3 without MCB to house appropriate nos. of
MCBs.(The DBs should be used of same company of MCB to be
used) suitable for
(A) single phase incoming and horizontal single phase outgoing
(a) single door (IP-30)
48 Providing & erecting 240 V MCB double pole switch for motor &
inductive load (C Curve) having 10 KA breaking capacity &
confirms to IS : 8828 in existing box having following capacity
49 25 A / 100 mA DP ELMCB 20.00 2323.00 Each
Cables and Wires
Item Quantity Rate Unit
50 Providing and erecting Mains with 1.1 KV grade FRLS PVC
insulated ISI marked stranded Copper conductor wire in following
type of pipe to be erected concealed in /flushed on wall/ceiling,
with 1.5 sq. mm copper conductor FRLS PVC insulated stranded
wire of green colour for earth continuity of following size.(A) with 300.00 82.82 Mtr
medium class Rigid PVC pipe and accessories.(b) 2 wire
51 Providing and erecting Mains with 1.1 KV grade FRLS PVC
insulated ISI marked stranded Copper conductor wire in following
type of pipe to be erected concealed in /flushed on wall/ceiling,
with 1.5 sq. mm copper conductor FRLS PVC insulated stranded
wire of green colour for earth continuity of following size 600.00 46.46 Mtr
(E) in existing pipe
(a) 2 wire 1.5 sq. mm
52 Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable
multistrand Copper conductor for 1.1 KV. to be laid on wall
with necessary clamps or in existing trench / pipe at road 300.00 676.70 Mtr
crossing or floor of following size of cables. (A) 4 core 10 Sq.
53 Providing and, fixing heavy duty flange type brass cable gland
with rubber ring for PVC insulated armoured cable complete with
out going tails, insulating tape etc for following size of cables. (C)
2 to 4 core 10 Sq. mm
54 Solder less crimping type Aluminium lugs conforming to IS
suitable for cable of following size evenly crimped with high
pressure tool & connected to switchgear terminals with 40.00 13.13 Each
brass/cadmium plated nut bolts in an approved manner. (B)
55 Making trench in soft soil of suitable width of 90 cm deep for
laying cable or locating the fault all over the run and back filling
the same and making the surface as normal ground.
56 Providing & laying approved make Double walled corrugated
pipes (DWC) of polyethylene(conforming to IS 14930 II )with
necessary connecting accessories of same material at required
depth in existing trench for laying of cable. below ground / road
surface for enclosing cable (A)50 mm outer dia
Earthing and Automatic sliding Doors & MISC
57 Providing and erecting HOT deep Galvanized iron strip wire 8 to
Item Quantity Rate Unit
58 Supplying & erecting earth pit of minimum bore dia.150mm size
approved make Earthing Electrode consisting Pipe-in-Pipe
Technology as per IS 3043-1987 made of corrosion free hot
dipped G.I.Pipes having Outer pipe dia of 50mm having 80-200
Micron galvanising, Inner pipe dia of 25 mm having 200-250
Micron galvanising, connection terminal dia of 12mm with
constant ohmic value surrounded by highly conductive compound
with high charge dissipation suitable for following type of
applications with chamber and heavy duty cover. (A)(approved
make OEM has to submit test certificate including value of earth
resistance of installation duly stamped and signed by agency and
officer Incharge has to ensure the value of earthing resistane
mentioned in test Certificate) & having back filling compound of
(B) Inner chemical (CCM Compound)- Resistivity:- 0.2 ohm /
meter testing as per IEC 62561-2017, Voltage drop:- < 1 volt at
no load & dry form, Sulphar content:- <2%(C) Back fill Compound
:- Earthing compound should be capable to retain moisture for
long time Necessary test report must be submitted by Agency.
(b)For Electrical installation up to 11 KV in normal
soil.Length of Pipe : 2.00 mtrs Back filling Compound :1 no.
59 Providing and fixing 01 units Automatic sliding Doors (2 leafs) of
size as per drawing for items to be fitted onto the Bus Station
excluding any other RF component.) with Four Door RF Controller
with 3 RFID Reader with weatherproof Stainless-Steel enclosure
to be fitted near the bus door with Emergency Door operations
Switche in Ticket office (inclusive of two-year warranty period) +
Four Door RF Controller (inclusive of two-year warranty period) +
RFID Reader with weatherproof Stainless-Steel enclosure to be
fitted near the bus door (inclusive of two-year warranty period) +
Emergency Door operations Switche in Ticket office (inclusive of
two-year warranty period) ( SD unit Per Station .Each Unit
comprise two leafs)
Total Electric Work
SIGNATURE OF THE CONTRACTOR.
EXECUTIVE ENGINEER
TRAFFIC BRTS PROJECT CELL
SURAT MUNICIPAL CORPORATION
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
Tech Bid Final 3rd Attempt.pdf
SCHEDULE-B 3rd Attempt.pdf
Conceptual Design Detail Drawing.pdf
Download all tender documents and submit your bid