Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹38.2 LAccepted-AOC ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | VISAKHAPATANAM | ANDHRA PRADESH | 530001 | 1 | Accepted-AOC AWARDED BEING THE LOWEST TENDERER | |
| 2 | 2₹39.8 L+₹65,192 (1.67%)Rejected-Finance | 2 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER | |
| 3 | 3₹41.3 L+₹2.2 L (5.59%)Rejected-Finance 66 6 410 1 MULAGANDA HOUSING COLONY GAJUWAKA DEPOT VISAKHAPATNAM 530026 | VISAKHAPATANAM | ANDHRA PRADESH | 530026 | 3 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER | |
| 4 | 4₹42.2 L+₹3.1 L (7.98%)Rejected-Finance | 4 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER | |
| 5 | 5₹43.4 L+₹4.3 L (10.9%)Rejected-Finance NO 24 54 21 5 LIG 408 VUDA COLONY VINAYAKA NAGAR GAJUWAKA VISAKHAPATNAM 530026 | VISAKHAPATNAM | VISAKHAPATANAM | ANDHRA PRADESH | 530026 | 5 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER |
Tender Value
₹48.2 L
EMD Value
₹96,400
Closing Date
3 Mar 2022, 6:00 pmClosed
GE NAVAL BASE VISAKHAPATNAM
Garrison Engineer (Naval Base) Nausenabaugh Gandhigram PO Visakhapatnam 530 005
SPECIAL REPAIRS TO BLDG NO P-35 AT INS SATAVAHANA SPECIAL REPAIRS TOM STATIC WATER TANK AT CERTAIN UNIT AND AS AND AS TO DRAIN COVER AT NAVAL PARK FROM OUTSIDE BOUNDARY WALL TO FOOT OVER BRIDGE AT NORA UNDER GE (NB) VISAKHAPATNAM
2022_MES_503903_2
C/8998/E8 / Token 92 of 2021-22
Open Tender
Civil Works
Item Rate
180 days
VISAKHAPATNAM
Pl refer Tender Document
8 documents required · 8 mandatory
₹500
Yes
GE NAVAL BASE VISAKHAPATNAM
₹96,400
Yes
31 Mar 2022
15 Feb 2022
5 Mar 2022
15 Feb 2022
3 Mar 2022
23 Feb 2022
Amount
Taking down cement plaster on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water and removing rubbish to outside MD land complete all as specified and directed
M & L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished the surfaces even and fair without using extra cement complete all as specified and directed.
M & L for rendering 15 mm thick in two coats (10mm+5mm each) on fair faces of brick work or concrete surfaces in cement mortar 1:4, mixed with integral water proofing compound with weight of cement in top layer as per manufacturer's instructions and finished the surface even and fair without using extra cement complete all as specified and directed. (Note : WPC shall be measured and paid separately against respective item).
Supply only integral water proofing compound (ISI marked) complete all as specified and directed.
M & L for preparing newly plastered surfaces of internal walls, etc and applying two coats of distemper oil emulsion over a coat of alkali resistant primer and over one or more coats of wall care putty to a smooth surface complete all as specified and directed.
M & L for preparing old plastered surfaces of walls by complete removal of existing treatment and applying two coats of distemper-oil-emulsion over a coat of alkali resistant priming coat over one or more coat of wall care putty complete all as specified and directed.
M & L for preparation new external surfaces of wall etc and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces over one or more coats of wall care putty to a smooth finished surface complete all as specified and directed.
M & L for preparation old decorated external surfaces of wall, chajja, facia etc by complete removing old paints by mechanical scrubber without disturbing the plastered surfaces and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces over one or more coats of wall care putty to a smooth finished surface complete all as specified and directed.
M & L for Preparation of old painted wood and wood based surfaces of any description, over 10 cm in width or girth, not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed.
M & L for Preparation of old painted steel surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coat of Synthetic enamel paint complete all as specified and directed.
M & L for post construction Antitermite treatment Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron.complete all as specified and directed.
M & L for post construction Antitermite treatment Treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete all as specified and directed.
Taking down chowkats or frame, n.exc 1.5 Sqm each with shutters (without taking off shutter from the frame) complete all as specified and directed.
S & F Aluminium powder coated windows frame with shutters sliding pattern consisting of three tracked frame and 03 shutters (2 shutters glazed and 01 shutter gauge) using standard medium weight section of weight not less than 0.55 Kg/RM including glazing with 5 mm thick tinted sheet glass fixed with suitable EPDM rubber beading and one shutter with nylon mesh duly fixed with U clamp for mosquito proof and 10mm dia aluminium grill (Deco, DG-104) with aperture of size 60x40mm suitable for F & E section fixed to window frame and necessary handles/locking arrangements for shutter of Jindal (or equivelant) sections Window Frame ( Top & Sides) : 21137, Bottom L 20977, Window shutters : Top & Bottom : 20567, Sides : 20738 complete all as specified and as directed.
M & L for Making good under cills (or over arches, lintels and bressummers) including all pinning as necessary in cement mortar 1:4 complete all as specified and directed.
M & L for Forming jambs, etc. to openings (to foregoing item), including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work in cement mortar 1:6 complete all as specified and directed.
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, in roof covering including ridges and keeping serviceable sheets in safe custody for reuse in the work complete as directed.
Dismantling structural steel work including doors, gates but excluding framed truss etc. complete all as specified and directed.
S & F Pre-Painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as per manufacturer's instruction complete all as specified and directed.
S & F Pre-Painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridges/vally gutter, fixed with self tapping screws as per manufacturer's instruction complete all as specified and directed.
M & L for Rolled mild steel fo grade Fe 410-W (Gde-E- 250) quality-A as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat section) including distance pices, cleat etc complete all as specified and directed.
M & L for plain cement concrete (1:2:4), type B1 (using 20mm graded stone aggregate) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including necessary formwork complete all as specified and as directed.
Dismantling of wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
M & L for Mild steel framed work such as grills, gratings, gates etc., with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bar, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe-410-0 Gde E-250 complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and disposal of debris and rubbish to outside MD land complete all as specified and directed.
M & L for 25 mm thick, plain cement concrete 1:2:4, type B-0 (using 12.5 mm graded stone aggregate) as in sub-base of flooring, etc and finished the surface even and rough complete all as specified and directed.
M & L for non-skid, ceramic, coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.18 sqm but n.exc 0.38 sqm, in floors etc, including 15 mm thick screed bed in cement mortor 1:6 and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed.
M & L for non-skid, ceramic, coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.18 sqm but n.exc 0.38 sqm, as in vertical surfaces as in skirting, dado etc, including 10 mm thick screed bed in cement mortor 1:4 and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation etc.) any thickness including cover fillets/snap grid etc complete all as specified and directed.
S & F GI frame work for seamless ceiling comprising of GI perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to cerntre / intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre complete including Hangers 6 mm dia GI (upto 1200 mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of GI flat 40 x 3 mm size 60 mm long and expansion hold fasteners 12.5 mm dia, 40 mm long complete all as specified and directed.
M & L for Providing and fixing Gypsum Board, 12mm thick in ceiling fixed with screw as per manufacturers instructions complete all as specified and directed.
M & L for Preparation of new plastered surfaces of ceiling of any description over 10 cm width or girth not otherwise described and applying two coats of plastic emulsion paint over a coat of primer over one or more coats of wall care putty to a smooth surface complete all as specified and directed.
Taking down eaves gutters and rainwater/soil/waste pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed
S & F 0.71mm thick Plain, Aluminium sheeting, Alloy 31000 H4 in ridges, hips, valley gutter, drip and straight flashing (length and girth as fixed) complete all as specified and directed.
S & F 110 mm bore, PVC (SWR), Soil waste and vent pipes in any length with or without ears, with cement joints fixed to wall, etc with all necessary fixing arrangement complete all as specified and directed.
Taking down chowkats or frames, exc 1.5 but n.exc. 4 Sqm in each with shutter (without taking off shutter from the frame) complete all as specified and directed.
S & F aluminium anodised door, single shutter type, side hung, fabricated with anodised aluminium extruded sections consisting of frame top and side member of size 63.5x38.10x2.0mm thick and door shutter consist of vertical styles of size 85x44.45x2.00mm, top and bottom rail of size 95.25x44.45x2.00mm and middle rail of size 100x44.45x2.0mm thick; top half of shutter shall be provided with 5mm thick tinted glass and bottom half shall be provided with 12mm thick prelaminated particle, medium density, interior grade, both side ldecorative including aluminium beading and rubber gaskets of suitable size including supply and fixing of 02 Nos aluminium handle of size 230mm, 01 No Hydraulic floor spring, 02 Nos aluminium tower bolt of size 200mm, one brass lock, 5 livers with two keys and necesary hinges complete all as specified and directed.
S & F Well seasoned 2nd class hard wood plain, solid, straight chowkat and frames, wrought, framed, rebated on the solid rounded or chamfered, put together with glue pinned at joints complete all as specified and as directed.
S & F 40 mm thick, factory made Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed.
S & F 35 mm thick, 2nd class hardwood, factory made, Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed.
S & F PVC ventilators with frame work shall be made of multi chamber hollow PVC section (40X46mm), the glass (3mm thick pin headed) is fixed to the frame in the lower section using extruded PVC section having a dimension of 9mm X 14.5mm with EPDM gasket for both the PVC sections centre mullion shall be made up of multi chamber hollow PVC section (63.5mmX40mm) with EPDM gasket fixed to the 3 sides of section (40X46mm) and to one side of section (63.5X40mm) above the centre mullion. Glass panels with aluminium lower set is fixed to the frame section (40X46mm) on the top of the ventilator for the glass.Corners shall be mitred cut and welded, jointed with and including 12 mm MS rods (guard bars) and necessary fixtures complete all as specified and as directed.
S & F 200 mm long, Aluminium, anodised, barrel tower bolts of extruded section complete all as specified and directed.
S & F Aluminium alloy anodised sliding door bolt with hasp & staple (bolt type) and fixing clipes of sheet, cast or extruded sections and fixing bolts of extruded sections or cast aluminium alloy, length of bolt of 300 mm complete all as specified and directed.
S & F 125 mm size, butt hinges, medium weight, cold rolled mild steel complete all as specified and directed.
S & F 150 mm size, extruded Aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
M & L for plain cement concrete 1:3:6, type C-1 (using 20mm graded stone aggregate) for embedding holdfast, in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating as directed complete all as specified and directed.
S & F mild steel bands, straps, supports or stays of rain water, ventilating pipes including bolts, hooks (stay) for large gates, hook and pintel hinges, clamps, hold fasts, wall ties, flat iron fillets for securing wire mesh, wind tie, fan hook and similar work including necessary drilling bolting or riveting etc conforming to Fe – 290 Gde E – 165 complete all as specified and as directed.
M & L for Preparation of new or previously untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint (1st grade quality) over a coat of pink primer complete all as specified and directed.
M & L for Preparation of new steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide, zine chrome primer complete all as specified and directed.
M & L for preparation of new or previously untreated steel surfaces of any description, n.exc 10 cm width or girth when unconnected with other painting or when painted in different tint and applying two coats of synthetic enamel paint over a coat of red oxide, zinc chrome primer complete all as specified and directed.
S & F in repair 20 mm dia, Aluminium anodised, curtain rod with bracket complete all as specified and directed.
S & F Floor door stopper of aluminium alloy body and tongue, anodised, 150 mm overall length of cover plate with hard drawn steel spring, fixed in floor complete all as specified and directed.
S & F in repairs, Aluminium (Die cast) body door Closer hydraulically regulated, designation No 3, universal type, suitable for door shutter of 851 to 1000 mm in width and of weight between 61 to 80 Kg complete all as specified and directed.
Demolition of un-reinforced cement Concrete of any description and in any position not otherwise specifically provided for and removing rubbish to outside MD land complete all as specified and directed.
M & L for 75 mm thick, plain cement concrete 1:3:6, type C-2 (using 40mm graded stone aggregate) as in plinth protection etc, finishing cement concrete surface even and smooth without using extra cement including making joints with bitumastic filing in proportion of bitumen and sand 1:2 complete all as specified and directed.
Demolition of un-reinforced cement concrete in ground floors and pavings n.exc 15cm thickness, (Below or above Ground level) and disposal of debris and rubbish to a distance upto outside MD land complete all as directed by the Engr-in-Charge
Demolition of brick work or stone / boulder masonry, built in cement mortar including all quoins, pillars etc stacking the serviceable bricks after removing mortar and cleaning for re-use and disposal of debris and rubbish to a distance n.exc 100m as directed by the Engr-in-Charge.
M & L for Plain cement concrete 1:3:6, type C-2 (using 40mm graded stone aggregate) as in surface channel, drains etc complete all as specified and directed.
Extra for forming fair finished to concrete surface of drain 30cm inner girth in cement including forms, mould, mitred/stopped etc complete all as specified and as directed.
Add or deduct for each 25mm girth or part thereof over or under 30cm including form mould, mitred/stopped etc. complete all as specified and as directed.
M & L for Brick work with fly ash brick, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 using old size brick complete all as specified and directed.
M & L for brick work with fly ash bricks, straight or curved on plan to any radius, built in cement mortar 1:4 as in half brick thick walls using old size brick complete all as specified and directed.
M & L for preparing newly plastered surfaces of walls, etc and applying three coats of white wash complete all as specified and directed.
M & L for Machine cut green marble slab flooring 18 to 20mm thick, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including 15 mm thick screed bed in cement mortor 1:6 and rubbing, polishing complete all as specified and directed.
M & L for Machine cut green marble slab, 18 to 20mm thick, as in skirting/dado, laid and jointed with white cement slurry mixed with pigment to match the shade of the slab including 10 mm thick screed bed in cement mortor 1:4 and rubbing, polishing complete all as specified and directed.
Surface excavation n. exc 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil complete all as specified and directed.
Removing excavated material not exc. 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed.
M & L for Plain cement concrete 1:4:8, type D-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete, etc complete all as specified and directed.
M & L for 100 mm thick, Cement concrete 1:2:4, type B-1 (using 20mm graded stone aggregate) as in base of flooring/hard standing, etc, complete all as specified and directed.
M & L for Sand filling under floors or in foundations including spreading, levelling, watering and consolidation complete all as specified and directed.
M & L for Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness, M-40 Grade with grey cement and pigment complete all as specified and directed.
Opening the manhole cover and taking out sand/mud/foreign materials from static water tank including pumping out the left over water, removal of taken out sand/mud/foreign materials from site of work and deposited in to low laying area outside MD land complete all as specified and directed. (Note : (i) The depth of sand/mud/foreign materials shall only be considered for measurements).
M & L for Preparation of old treated surfaces of water storage tank/reservoir etc by complete removal of existing treatment by mechanically scrarifying the surfaces to receive epoxy treatment and prepare the surfaces free from grease, oil dirt colour coating or any any other surface coating, free from cement laitance and to achieve open texture and all the exposed, dust, loose and freeable materials shall completely be removed preferably by vaccum cleaner before coating the treatment and Providing and applying two coats of Deckguard S High Performance, aliphatic acrylate based, anticarbonation, protective cum decorative coating to be applied at 1 litre/6Sqm per coat applied with airless gun or brush over a coat of Primer as per the manufacturer's instructions complete all as specified and directed. (Note: Any loose plaster shall be removed completely before application of treatment which shall be measured and paid seperately) (Make: Fosroc or equivalent as per list of manufacturer's)
Taking up or down 40 or 50mm bore, Steel tubing and connections and keeping serviceable pipes in safe custody for reuse in the work after and including cleaning as directed.
Supply, laying, connection and testing, 50mm bore, Steel water tubing, galvanised, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors, etc complete all as specified and directed.
S & F in repair 25 mm bore, gun metal, globe or Gate valves with iron wheel head, screwed both ends for iron pipe complete all as specified and directed.
M & L for rendering 15 mm thick in cement mortar 1:3 on fair faces of brick masonry or concrete surfaces and finishing the surfaces even and fair without using extra cement mixed with water proofing compound as per manufacturer's instructions complete all as specified and directed. (Note: WPC shall be measured and paid seperately)
Supply only Integral water proofing compound (ISI marked) complete all as specified and directed.
M & L for 100 mm thick, Cement concrete 1:2:4, type B-1 (using 20mm graded stone aggregate) as in base of flooring/hard standing, etc, and finished the cement concrete surfaces even and fair without using extra cement complete all as specified and directed.
M & L for Forming 12mm thick, Expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘A’ for 100mm thick floor complete all as specified and directed.
Demolition of reinforced cement concrete in any position not otherwise specifically provided for and removing rubbish to outside MD land complete all as specified and directed.
M & L for Precast Reinforced Cement Concrete 1:2:4, type B-1 (using 20 mm graded stone aggregate) as in cover slab (For manhole etc), chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces and set in cement mortar 1:4 including necessary form, moulds, etc complete all as specified and directed by the Engr-in-Charge. (Note : Reinforcement shall be measured and paid separately)
S & F high strength corrosion resistant TMT steel bars 10 mm dia., and over cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality complete all as specified and directed.
Cleaning/de-silting of lose mud, rubish etc by mechanically/manually where ever required from covered drain bed after removing and re-placing in its existing position of covers including uprooting of vegetation growth throughly and wire brushing including flushing with water so as to achieve smooth flow of water in drain of bed width n exc 1.2 mtr & n. exc 2.0 mtr depth (soil mud upto 80cm depth) and including de-watering of flow of water in drain entirely by using Motor etc and removing the waste materials out side MD land to a distance n exc 15.00 km complete all as specified and as directed. Note : Actual removal quantity of materials (silt, sludge, soil, debris etc) to be measured and paid, not full volume of drain complete all as directed by the Engr-in-Charge
M & L for preparation of new or previously untreated steel surfaces of any description, n.exc 10 cm width or girth when unconnected with other painting or when painted in different tint and applying two coats of black bitumenous paint over a coat of red oxide, zinc chrome primer complete all as specified and directed.
M & L for preparation of new or previously untreated steel surfaces of any description, n.exc 10 cm width or girth when unconnected with other painting or when painted in different tint and applying two coats of synthetic enamel paint over a coat of red oxide, zinc chrome primer complete all as specified and directed.
M & L for plain cement concrete (1:2:4), type B-0 (using 12.5mm graded stone aggregate) as in hold fast block or similar work like bands, plinth courses, lacing courses, parapets and raiings upto 60cm height, copings, kneelers, bed plates feeling on pressed steel door frame including necessary formwork complete all as specified and as directed.
M & L for rendering 15 mm thick on other than fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished the surfaces even and fair without using extra cement complete all as specified and directed.
Taking down carefully unserviceable aluminium/copper point wiring (light, fan, socket or power) complete, (fitting such as switches, ceiling roses, pendants, regulators, sockets, etc to be measured separately if found serviceable), removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls, floors, etc complete all as specified and directed.
Taking down unserviceable main switches, DBs, bus bars chambers including all fittings and fixtures such as MCBs, isolator, etc and removing from site complete all as specified and directed.
Taking down unserviceable sub-main wiring (any numbers of cable) with rigid steel conduits/PVC casing-caping including cutting chases for conduits and making good disturbed surfaces complete all as specified and directed.
M & L for Point wiring with two runs of single core 1.5 Sq.mm. (Nominal area) PVC insulated unsheathed multistranded copper conductor cable FRLS (ISI marked) drawn through and including non metallic PVC conduit 20 mm bore (Minimum) medium grade (ISI marked) concealed type including Flush type metal GI boxes of suitable module including modular white cover plate of suitable module for fixing modular type switches including provision of multistranded 1.5 Sq.mm copper conductor cable FRLS [ISI marked] as earth wire connected to common earth dolly and earth in distribution board for one light/exhaust fan/fan point/call bell controlled by one way switch complete all as specified and as directed. (Note.: (i) The rate quoted is deemed to include making good the disturbed sufaces and to match the adjoining surface. (ii) The quoted rate is deemed to include cutting chases for concealed wiring including making good the same as per the existing one)
All as per item No. 92 above but for One 3/5 pin socket outlet 6 amps on independent board complete ditto
All as per item No. 92 here in before but for one 15 Amps power point on the independent board with two runs of PVC insulated and unsheathed copper conductor cable of size 2.5 sqmm multistranded FRLS (ISI marked) and 2.5 sqmm PVC insulated unsheathed solid copper conductor cable FRLS (ISI marked) as earth lead complete ditto
All as per item No. 92 here in before but for one 15 Amps power point on the independent board with two runs of PVC insulated and unsheathed copper conductor cable of size 4 sqmm multistranded FRLS (ISI marked) and 4 sqmm PVC insulated unsheathed solid copper conductor cable FRLS (ISI marked) as earth lead complete ditto
S & F switch modular single pole one way 6 amp 240 volts,1 Module complete all as specified and as directed.
S & F ceiling rose, 65 X 50mm two to three terminals, PVC/polycarbonate, insolated body complete all as specified and directed.
S & F Modular socket outlet 6A, 2/3 pin combined, 2 module,AC 230V, 50HZ,conforming to IS 1293 :2005 (incl all revisons and amendments). complete all as specified and as directed.
S & F Modular Switch socket outlet multipurpose 3 pin, 15 amp and one pin, 5 amp controlled by one switch, AC 230V, 50HZ, complete all as specified and as directed.
S & F steped type modular fan regulator ,100/120 W 1/ 2 module complete all as specified and as directed.
S & F Concealed sheet metal enclosure with socket plug top and MCBs having single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of capacity 20Amp 240V, B-curve complete all as specified and as directed.
M & L for Sub main wiring with 2 runs of Single core 2.5 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLS (ISI marked) copper cable drawn through and including surface / ceiling / concealed PVC conduit of suitable size with all conduit accesories and fittings along with 1 run of single core 2.5 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed. (Note :- Two runs of 2.5 sqmm and one runs of 2.5 sqmm cable as earth wire and one run of conduit shall be measured as one length)
M & L for Sub main wiring with 2 runs of Single core 6 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLS (ISI marked) copper cable drawn through and including surface / ceiling / concealed PVC conduit of suitable size with all conduit accesories and fittings along with 1 run of single core 6 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed. (Note :- Two runs of 6 sqmm and one runs of 6 sqmm cable as earth wire and one run of conduit shall be measured as one length)
M & L for Sub main wiring with 4 runs of Single core 10 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLS (ISI marked) copper cable drawn through and including surface / ceiling / concealed PVC conduit of suitable size with all conduit accesories and fittings along with 1 run of single core 10 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed. (Note :- Four runs of 10 sqmm and one runs of 10 sqmm cable as earth wire and one run of conduit shall be measured as one length)
Taking down ceiling fan / EXHAUST FAN any sweep from the site and replacing the defective parts such as shakle & clamps including, rubber bush, bolts, nuts & split pin (Chera Pin), washer etc. for ceiling fan and ensure proper inserting the quarter/ Split pin to hold the nut and bolt on fan downrod at fix position including servicing, oiling and greasing and re-fixing the ceiling fan / exhaust fan of any sweep again at existing site all as specified and as directed .
M & L for preparation of old painted surfaces of ceiling fan/Exhaust fan of any size/sweep/make, cleaning all dust etc and painting with one coat of synthetic enamel (1st grade quality white) paint by spraying including filling cavities with filler and marking same MES No. with parmanent marker etc complete all as directed. (Note: The ceiling fan/Exhaust taken down under Serial item No. 105 above shall be painted and measured under this item.)
S & F Vertical TPN DB double door for provision for four pole MCCB upto 160 A incommer 4 way 12 outgoing with IP 43 protectioncomplete all as specified and as directed. (Make : Legrand cat part No. 5077 45 or equivelant of make as per List of manufacturer's)
S & F MCCB 415 Volt 16 KA, 3 Pole, 160 Amps Capacity complete all as specified and as directed . (Make: Legrand Cat Part No. 4200 07 or equivelant of make as per List of Manufacturer's)
S & F Distribution Board, SPN 8 Way, 240V, Double door with IP 54 protection complete all as specified and as directed. (Make: Legrand cat part No. 5076 41 or equivalent make as per List of Manufacturer's)
Supply, fixing, commissioning and testing MCB SPN 40-63 Amps, 240 Volts, 10KA, C curve complete all as specified and as directed (Make: Legrand cat part No. 4086 18 to 20 or equivalent make as per List of Manufacturer's)
Supply, fixing, commissioning and testing MCB SP 6 to 32 Amps, 240 Volts, 10KA, C Curve, complete all as specified and as directed (Make: Legrand cat part No. 4085 87 to 95 or equivalent make as per List of Manufacturer's)
S & F Exhaust fan, 380 mm sweep, heavy duty, metal body 1400 RPM, AC, complete with all accessories and louver and electric connection including making necessary holes in walls complete all as specified and directed (Make : Havells, Model : Turboforce FHEHDSPDB150 or equivelant of make as per List of Manufacturer's as approved)
M & L for Earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to galvanized steel earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel, all as shown in Electrical Plate No 3 of SSR Part - I, including necessary excavation and earth work, P.C.C (1:3:6) type C-I with 50 mm thick Pre-cast R.C.C. (1:2:4) type B-I cover slab (reinforced with 8 mm dia deformed bar @ 10 cm C/C both ways and suitable handle of 12 mm dia round bar), including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel and 20 mm bore galvanized iron watering pipe (light grade), wire mesh, aluminium lugs, complete in all respect, GI earth wire protected by 15 mm bore (medium grade) galvanized iron pipe and other end connected with main switch board or Earthing test point as directed, including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessary testing on completion inclduing taking down old one complete all as specified and as directed by the Engineer-in-Charge.
Dismantling existing unserviceable panel board of any size with all accessories after disconnecting all connection and re-routing the cables by using existing cable tray/clmaping where required and making good the disturbed surfaces to match the existing surfaces complete all as directed by the Engr-in-Charge
N Sydeswara Rao
GVR CONSTRUCTIONS
P SRINIVASA RAO
K & K CONSTRUCTIONS
Sri Vayuputra Constructions
MAHALAKSHMI CONSTRUCTIONS
S A R CONSTRUCTIONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .