Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.5 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹23.3 L+₹48,326 (2.12%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹23.3 L+₹49,888 (2.19%)Rejected-Finance | L3 | Rejected-Finance L3 | |
| 4 | L4₹28.5 L+₹5.6 L (24.7%)Rejected-Finance H NO 1300 PUSHP VIHAR COLONY GUPT GANGA ROAD KANGRA 176001 | KANGRA | KANGRA | HIMACHAL PRADESH | 176001 | L4 | Rejected-Finance L4 |
Tender Value
₹18.6 L
EMD Value
₹35,500
Closing Date
1 Aug 2022, 10:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
Elect. Division HPPWD Palampur
C/O 16 Nos. type-III Qtrs at Govt. Polytechnic College Talwar in Tehsil Jaisinghpur, Distt. Kangra, HP (Providing E.I. therein)
2022_PWD_63039_3
Elect. Division HPPWD Palampur
Open Tender
Electrical Works
Item Rate
730 days
Talwar in Teh Jaisinghpur, Distt. Kangra, HP
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
₹35,500
4 Aug 2024
25 Jul 2022
1 Aug 2022
25 Jul 2022
1 Aug 2022
25 Jul 2022
Amount
Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit with modular switch, modular plates, suitable G.I. box and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required. Make:- Legrand (Myrius)/ L&T(Oris)/ Anchor Roma (Plus)
Group A.
Wiring for twin control light point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit with 2-way, 5/6 amps. modular switch, modular plates, suitable G.I. box and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required. Make:- Legrand (Myrius)/ L&T(Oris)/ Anchor Roma (Plus)
Group A.
Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required.Make:- KEI/SCI/Havells/Plaza
2x2.5 Sq. mm.
2x4.0 Sq. mm.
2x10.0 Sq. mm.
Wiring for circuit/sub-main with 4x2.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 2 No.2.5 Sq.mm.(4X2.5+2X2.5) HRFRLS/PVC insulated single core copper conductor cable for earthing as required. Make:- KEI/SCI/Havells/Plaza
Wiring for circuit / sub-main with 4x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 2 No.4 Sq.mm. (4X4+2X4)HRFRLS/PVC insulated single core copper conductor cable for earthing as required. Make:- KEI/SCI/Havells/Plaza
Supplying and drawing following size of PVC insulated, heat resistant, flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in existing surface / recessed, Steel/PVC conduit as required. Make:- KEI/SCI/Havells/Plaza
3x2.5 Sq. mm.
Supplying and fixing following rating Modular switch /socket in the existing switch box / cover plate including connections etc. as required.
S.P. 5/ 6 Amps one way Modular switch.
5 pin, 5/ 6 Amps Modular socket outlet.
Supplying & fixing following size modular base and cover plate on the existing modular metal boxes as required:-
Modular base and cover plate, 6 module
Supplying and fixing G.I. Modular box of (140mmx78mmx50mm) size with modular plate and cover in recess including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps, modular switch, connections etc. as required. Make:- Legrand (Myrius)/ L&T(Oris)/Anchor Roma (Plus)
Supplying and fixing bakelite batten/angle holder including connections etc. as required:-
Supplying and fixing Ding-Dong / Electronic musical bell, suitable for D.C./A.C. single phase,230 volts complete as required:-
Supplying and erection of 6 amps. to 32 amps. rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:- (Make:- L&T, Legrand, Schneider)
Single pole. Cat-A.
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Make:- L&T, Legrand, Schneider)
63 Amps. Cat-A.
Supplying and fixing following rating, double pole (single phase & neutral) 240 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 miliampers in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Make:- L&T, Legrand, Schneider)
63 Amps. Cat-A.
Supplying and fixing of following way, single pole and neutral sheet steel MCB distribution board, 240 volts, on surface / recess, complete with tinned copper bus- bar, wire-set, neutral link, earth bar, din-bar, detachable gland plate, blanking plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required:- (Make:- L&T, Legrand, Schneider)
Double door-16 way
Earthing with G.I earth pipe 4.5 mtr. long and 40mm dia, including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. ( but without charcoal or coke and salt ) complete as required.
Extra for using salt and charcoal for pipe earth electrode complete as required.
Supplying and laying 6 SWG G.I. wire at 0.50 mtr. below ground level for earth electrode conductor, including soldering etc. as required.
Providing and laying of one No. aluminium conductor, PVC insulated and PVC sheathed, armoured/XLPE power cable, working voltage 1100 volts grade direct in ground; to be laid 1 meter below the ground level including excavation sand cushioning, protective covering and refilling the trench etc. of the required size:- Make:- KEI/SCI/Havells/Plaza
Armoured cable 70 sq. mm (3.5 core)
Providing and installation of exhaust fan of following sizes in the existing opening, including making the hole to suit the size of the above fan, making good the damages, connections, testing and commissioning etc. as required:- Make:- Bajaj/Usha/Crompton
Exhaust Fan, Light duty, (Domestic) 225 mm sweep
Supplying and fixing of fancy wall bracket containing thread type CFL lamp holder (s) of all sizes and shapes, complete with all accessories but excluding CFL lamp including making connections, testing etc. as required.
Fixed type wall bracket 150 dia, single lamp.(Category-A)
Supplying and fixing of fancy wall bracket containing thread type CFL lamp holder (s) of all sizes and shapes, complete with all accessories but excluding CFL lamp including making connections, testing etc. as required.
Mirror light 460 mm, single lamp.(Category-A)
Providing and fixing surface mounted Round downlighter with die cast Al housing in white powder coated finish, anti glare diffuser and and energy efficient electronic driver ,suitable for surface application with the use of the latest technology 15 watt (1500 Lumen) 4000K and it should be compatible with specification i.e. Power Factor > 0.9, Harmonic Distortion <10% and efficacy > 100 Lumens per watt, CRI rating> 80 suitable for input voltage: AC 220-240 V, 50 Hz, complete with all accessories, connections, testing and commissioning etc. as required.
LED Surface mounting Round downlighter 15 watt
Makes:- Panasonic (Cat No PDLM10154),Bajaj,Philips or any other make approved by Engineer in charge.
Providing and fixing LED bulk head fitting of following rating and it should be compatible with specification i.e. Power Factor > 0.9, Harmonic Distortion <10% and efficacy > 100 Lumens per watt, CRI rating> 80 suitable for input voltage: AC 220-240 V, 50 Hz, complete with all accessories, connections, testing and commissioning etc. as required.
LED Bulk head fitting 10 watt
Makes:- Panasonic(Cat No.-PBHM01107),Philips,Bajaj or any other make approved by Engineer in charge.
Providing, Installation, testing and commissioning of ceiling fan with socket size step type electronic fan regulator, including wiring the down rods of standard length (up to 30 cm) with 16/0.20 mm twin twisted flexible, cotton braided, copper cable, including providing and fixing phenolic laminated sheet cover on the fan box and earthing etc. as required.
Ceiling Fan 1200 mm sweep
Makes:- Usha Technix Plus 3 Star,Bajaj or any other make approved by Engineer in charge.
Providing and fixing indoor decorative aluminium extruded LED Batten and it should be compatible with specification i.e. Power Factor > 0.9, Harmonic Distortion <10% and efficacy > 100 Lumens per watt, CRI rating> 80 suitable for input voltage: AC 220-240 V, 50 Hz, complete with all accessories, connections, testing and commissioning etc. as required.
Batten for T8 Tube Light, Suitable For 1X18 Watt LED
Makes:- Panasonic, Philips, Bajaj(Cat. No. BLRB DB 118 ), Jaquar or any other make approved by Engineer-in-Charge.
Providing and fixing LED T8 Tube Light on the existing Batten complete with all accessories, connections, testing and commissioning etc. as required.
T8 Tube Light 18 Watt
Makes:- Bajaj (Cat. No. BLRB 18W CWC),Panasonic, Philips, Jaquar or any other make approved by Engineer-in-Charge.
Supplying and fixing LED Retrofit lamps of following watt with polycarbonate diffuser and aluminium heat sink on the existing light point as required complete in all respect .
LED Lamp 9 Watt
Providing and installation of stationary storage type Electric water heater (Geyser) of various sizes by means of Expansion-bolts with nuts and washers, including embedding of expansion-bolts in the wall, providing and fixing of Non-return valve, Dead weight safety valve, 2 No C.P. connection rods 18" long, making good the damages, electrical connections, safety valve connections, testing and commissioning etc. as required:- Make:- Bajaj/Usha/Crompton
25 Liter capacity water heater (Cat-A)
Supplying, Installation, Testing and Commissioning of indoor s/door, Wall mounted, fixed type, free standing single front, dust proof & compartmentalized 6 way Compartment Meter box made out of M.S. CRC Sheet 16G,duly painted with Siemens Grey Powder Coated Paint as per specification Appropriate Size (H)1400 mmX (W)750mmX (D) 150mm & assembly Charges of 200A 4 sTRIP Copper Busbar ( Horizontal/Vertical) & Earth strip throughout the length of Panel (current density of Copper Busbar shall be 1mmx1mm=1.66 Amp.) Copper shall be Electric Grade E-91E, Busbar supports shall be DMC epoxy Insulators. All Busbars Links shall be covered/ insulated with Heat Shrinkable sleeves of coloured coded Red, Yellow, Blue & Black & Assembly Charges of Copper solid/ Copper flexible wire interconnection Busbar to MCCB/Meter to field side for Cable termination duly covered/ insulated with Heat Shrinkable sleeves of coloured coded Red, Yellow, Blue & Black. All Interconnections of fields side are supported by conical, L & Finger type insulators of adequate size to support & sustain the weight of cablesControl Wiring with Copper Flexible Wire (size of control wire shall be 2.5 sq. mm copper flexible for C.T. Circuit & 1.0 sq. mm for Control Wiring) with thimbles printed sleeves, tie & belt etc. also assembly Charges of Accessories like Gasket, Doorlocks, Copper Flexible door earth, legend plates etc. and the panel should be approved/ tested from CPRI lab and conforming to IS 64139.Makes:-EVA/KSB or any other equivalent make.
Main Incomer
MCCB 160A 3P 25KA TMR With O/L & S/C Protection 1No.
Spreader Link MCCB 100A 3P 2No's
Indication Lamps LED Type RYB 3No;s
Control SP MCB 6A 3No's
Outing
Space for KWH Meter S/Phase 8No's
MCB 63A DP 10KA 6No's
DMC Strip 3No's
All interconnections of fields side are supported by conical, L & finger type insulators of adequate size to support & sustain the weight of cables, Control wiring with copper flexible FRLS wire with thimbles, printed sleeves, tie & belt etc;
The prices of complete job as per the specifications above shall be inclusive of gasket, doorlocks, reading glass,wooden, copper flexible door earth, legend plates etc.
Rajesh Kumar Jaswal
Vinay Chaudhary
Deepak Sood
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .