| Sl No | Description | Qty | Unit | m/s Firoz khan L1 | BEYLIM INFRA L2 | M/S KAUTILYA GARG L3 |
|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches not exceeding 1.5m wide and not exceeding 10 Sq.m on plain area and not exceeding 1.5m deep in any type of soil complete all as specified and directed. | 396 | Cum | 110 ₹43,560 | 100 ₹39,600 Lowest | 120 ₹47,520 |
| 2.00 | All as per item no. 1.00 here-in-above but depth exceeding 1.5m but not exceeding 3m | 150 | Cum | 180 ₹27,000 | 120 ₹18,000 Lowest | 150 ₹22,500 |
| 3.00 | Returning filling in including spreading , leveling , watering and well ramming in layer n. exc 25 cm complete all as specified and as directed. | 360 | Cum | 30 ₹10,800 Lowest | 50 ₹18,000 | 40 ₹14,400 |
| 4.00 | Removal of surplus loose soil from excavated place and deposting at safe side distance not exceeding 50 meter from excavated place complete all as specified and as directed. | 186 | Cum | 50 ₹9,300 Lowest | 80 ₹14,880 | 50 ₹9,300 Lowest |
| 5.00 | M&L plain cement concrete 1:4:8 type D-2 by using 40 mm graded crushed stone aggregate as in foundation, filling and mass concrete and sub base complete all as specified and as directed. | 140 | Cum | 1,800 ₹2,52,000 Lowest | 2,200 ₹3,08,000 | 2,200 ₹3,08,000 |
| 6.00 | Demolition and breaking up RCC/Salt glazed stoneware drain pipe set & jointed in cement mortar laid in trenches, suitable for 150mm bore of pipe, complete all as specified and directed. | 50 | RM | 8 ₹400 Lowest | 25 ₹1,250 | 10 ₹500 |
| 7.00 | All as per item No. 6.00 here-in-above but size 200mm dia pipe | 700 | RM | 12 ₹8,400 | 30 ₹21,000 | 10 ₹7,000 Lowest |
| 8.00 | All as per item No. 6.00 here-in-above but size 300mm dia pipe | 50 | RM | 15 ₹750 | 50 ₹2,500 | 10 ₹500 Lowest |
| 9.00 | Supply, laying, testing & commissioining DWC HDPE pipe ID 150/172 mm, SN-8, laid in trenches, aligning and jointed, over existing bed complete with collar fixed and jointed with rubber ring and couplers complete all as specified and as directed. | 50 | RM | 480 ₹24,000 | 350 ₹17,500 Lowest | 500 ₹25,000 |
| 10.00 | All as per item No. 9.00 here-in-above but size 200/230mm dia pipe | 700 | RM | 550 ₹3,85,000 | 480 ₹3,36,000 Lowest | 750 ₹5,25,000 |
Tender Value
₹28 L
EMD Value
₹56,000
Closing Date
10 Jul 2025, 6:00 pmClosed
CWE ARMY JODHPUR
CWE ARMY MULTAN LINE ARMY AREA JODHPUR-342010
SPL REPAIR TO SEWAGE LINE OF GOVT MD ACCN BLDG NO. P-198, P-199, P-200, P-201, P-202, P-203, P-204 AND P-205 AT LANCER LINE-II AND SPL REPAIR REPLACEMENT OF FALSE CEILING AT KONARK WAR MEMORIAL AT ARMY AREA JODHPUR UNDER GE (A) NO. 01 JODHPUR
2025_MES_712992_1
82425/98/E8
Open Tender
Civil Works
Item Rate
180 days
JODHPUR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (ARMY) NO. 01 JODHPUR
₹56,000
Yes
4 Sept 2025
6 Jun 2025
17 Jul 2025
6 Jun 2025
10 Jul 2025
21 Jun 2025
9 Jun 2025 - 20 Jun 2025
Amount
Excavation in trenches not exceeding 1.5m wide and not exceeding 10 Sq.m on plain area and not exceeding 1.5m deep in any type of soil complete all as specified and directed.
All as per item no. 1.00 here-in-above but depth exceeding 1.5m but not exceeding 3m
Returning filling in including spreading , leveling , watering and well ramming in layer n. exc 25 cm complete all as specified and as directed.
Removal of surplus loose soil from excavated place and deposting at safe side distance not exceeding 50 meter from excavated place complete all as specified and as directed.
M&L plain cement concrete 1:4:8 type D-2 by using 40 mm graded crushed stone aggregate as in foundation, filling and mass concrete and sub base complete all as specified and as directed.
Demolition and breaking up RCC/Salt glazed stoneware drain pipe set & jointed in cement mortar laid in trenches, suitable for 150mm bore of pipe, complete all as specified and directed.
All as per item No. 6.00 here-in-above but size 200mm dia pipe
All as per item No. 6.00 here-in-above but size 300mm dia pipe
Supply, laying, testing & commissioining DWC HDPE pipe ID 150/172 mm, SN-8, laid in trenches, aligning and jointed, over existing bed complete with collar fixed and jointed with rubber ring and couplers complete all as specified and as directed.
All as per item No. 9.00 here-in-above but size 200/230mm dia pipe
All as per item No. 9.00 here-in-above but size 300/330mm dia pipe
M&L plain cement concrete 1:2:4 type B1 using 20mm graded crushed stone aggregate as in coping including necessary form work complete all as specified & directed.
M&L for precast RCC 1:2:4 type B1 (using 20 mm graded stone aggregate) as in precast manhole/drain covers including demolition of RCC slab, manhole/drain cover in any position complete all as specified and as directed. Note : Slab covers shall be floated with surface vibrator,and over turfed base ,arrangement for turfed base has to be from contractors side
M&L for mild steel steel TMT bars 6mm to 8mm dia and over cut to length bent to shape reqd ,incl cranking ,bending spirally for hooping columns hooking ends and binding with mild steel wire annealed not less than 0.9 mm dia, complete all as specified and as directed.
M&L for framed work as in frames to manhole covers of angle or other section including hold fast conforming Fe-410-O, complete all as specified and as directed.
M&L for extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, incl forms moulds, mitered/stopped ends etc, complete all as specified and as directed.
Supply only integral water proofing compound, complete all as specified and as directed.
M&L for dismantling old abondoned existing manholes any depth with debris and making good to earth, complete all as specified and as directed.
Dismantling of sand cast CI / RCC drain pipe jointed in cement mortor of size 100mm bore and taking out trenches, if required complete all as directed
Dismantling of sand cast CI / RCC drain pipe jointed in cement mortor of size 75mm bore and taking out trenches, if required complete all as directed
S&F 75mm bore Cast iron soil sand caste pipes waste and vent (from gully trap to manhole) pipes in any length with or without ears,with cement joint,laid in trenches or in floors including making good to disturbed surface, complete all as specified and as directed.
All as per item No. 21.00 here-in-above but fixed to wall with MS clamp
S&F 100mm bore Cast iron soil sand caste pipes waste and vent (from gully trap to manhole) pipes in any length with or without ears,with cement joint,laid in trenches or in floors including making good to disturbed surface, complete all as specified and as directed.
All as per item No. 24.00 here-in-above but fixed to wall with MS clamp
Demolition of stone / boulder masonry walling, built in cement mortar including all quoins, arches, pillars etc and removal unserviceable materials, debris, rubbish to out side MD land complete all as specified and directed.
M&L random rubble stone masonry, regular coursed, well bonded, bedded and solidly hearted, built in cement mortar 1:6 complete all as specified and as directed.
All as per item No. 27.00 here-in-above, but except stone
Extra over stone walling for hammer dressing to face granite or trap stones with maximum depression on face from a straight edge held against the dressed surface not exceeding 20mm and dressing face beds and joints as specified of random rubble walling un-coursed or brought upto or regular courses complete all as specified and as directed .
M&L for PCC 1:3:6, type C1, using 20mm graded crushed stone aggregate as in surface channel and drain beds including all necessary form work.
M&L for Cutting in to existing manhole for connecting new drains,making good to pipe and rendering ,cutting out existing benching and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished ,and reforming benching as required for 150mm/200mm/300mm complete all as directed.
Taking down existing cement plaster including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for rendering 15 mm thick in cement mortar1:6 on stone masonry surfaces or other than fair face of brick work finished even and smooth without using extra cement complete all as specified and as directed.
M&L for rendering 15 mm thick in cement mortar1:4 on stone masonry surfaces finished even and smooth without using extra cement complete all as specified and as directed.
M&L for rendering 10 mm thick in CM 1:4 on stone masonry surfaces of wall finished even and smooth without using extra cement complete all as specified and as directed.
Racking out joints/ pointing to square rubble masonary, Jodhpur type, regular coursed built in cement mortar or cement lime mortar, coursed or un-coursed in walls not less than 12mm deep, washing the joints, removing rubbish off the premises and keeping the surface to pointed or plastered wet for two days prior to re-pointing or plastering complete all as specified & directed
M&L for keyed pointing in CM 1:3 to square rubble stone masonry wall surfaces, Jodhpur type regular course complete all as specified and as directed.
M & L two coats of white wash on newly plastered/ unplastered surface of wall including preparation and one coat of chalk white of serfaces complete all as specified and directed.
S & F in repairs white vitreous china squatting pan "Orissa pattern" of size 580 mm X 440 mm with integral foot rests and PVC 'P' or 'S' trap including provision of cement concrete bedding 1:5:10 type E2 complete all as specified and as directed.
S & F as in repairs vitreous china wash down water closet Anglo Indian type pedestal pattern with seat & cover complete incl fixing of flush pipe etc complete all as specified and directed.
S & F 10 ltrs capacity PVC valve less, syphonic action type, flushing cistern, low level, white with inlet, ball valve, float and handle including brackets, flush pipe of 32 mm dia and PVC connection 15mm size, 450 mm long with PTMT nuts complete all as specified and as directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings not exc 15 cm thickness (below or above ground level) and removal unserviceable materials, debris and rubbish to a distance out side MD land complete all as specified and as directed.
M&L for 75 mm thick PCC type C-2, 1:3:6 , using 40mm graded crushed stone aggregate as in sub base for receiving floor finishes finished even and fair.
S&F machine made precast cement concrete blocks (interlocking paves) Rubberised finish coloured (lacquer coated) of 60mm thick M-35 Grade all as per sample kept in GE Office laid over 50mm tick sand filling layer & spreading fine sand over the tiles to fill in the joints & cleaning the same after filling of joints complete all as specified and directed by Engr-in-Charge(Shape and size shall be approved by Engr-in-Charge).
M&L machine made precast cement concrete (1:3:6) type C-1using 20mm graded crushed stone aggregate as in kerb stone or mud steps, rounded or chamfered on edge, fixing of holdfast etc complete all as specified & directed by Engineer-in-charge.
M &L for cutting to bituminious road for laying of RCC hume pipe any dia & making good as per road specification and as per direction of Engr-in-Charge.
M &L (SWR) gully trap 125/110mm setting and jointing with solvent cement
Cleaning of manholes complete of any size and at any location incl taking out sludge and other material deposited in manhole by mechanical means and its disposal to a distance n exc. 50m suitable for depth of manhole n exc 1.00 M, complete all as directed
All as per item no. 47.00 here-in-above but depth of manhole exc 1.00 M and n exc 2.00 M
All as per item no. 47.00 here-in-above but depth of manhole exc 2.00 M and above
Cleaning/Removal of sewage block in the existing line incl cleaning of complete line laid at any depth and at any location between two consecutive manholes to manhole incl testing the pipe by pouring water from manhole all as directed to the entire satisfaction of Engr-in-Charge for 150mm bore SGSW/RCC pipe .
All as per item no. 50.00 here-in-above but 200mm bore SGSW/RCC Pipe.
All as per item no. 50.00 here-in-above but 250mm bore & above SGSW/RCC Pipe.
Cutting and grubbing of bushes grass and tree surrounding manholes,Gully trap, bend, wall pipe and overhead tank etc and levelling of ground around the manholes and finish the surface of wall and removing the waste material to a distance exc 50m and n exc 250m and clearing the site.
S&F 50 to 75 mm thick Jodhpur type machine cut stone slab not exc 2m in length dressed all face & along exposed edged size faced both sided as in drain cover/MH cover complete.
S&F GI tubing 20mm bore medium grade with all fittings and fixed complete to walls and ceiling or laid in floors, including taking down or up steel / PVC tubing and connection including cleaning for refixing or removal to store, complete all as specified and as directed.
S&F GI tubing 15mm bore medium grade with all fittings and fixed complete to walls and ceiling or laid in floors, including taking down or up steel / PVC tubing and connection including cleaning for refixing or removal to store, complete all as specified and as directed.
M&L GI frame work for seamless ceiling comprising of GI perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylone sleeves and screws at 450mm centre to centre / intermediate channel 0.9 mm thick having two equal flanges of 15mm each and web of 45 mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fasterners with and including ceiling section ( not exc 1.2m length) of 0.55 mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457mm centre to centre complete inclduing hangers 4 mm dia G I (upto 1200 mm length ) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3 mm size 60 mm long and expansion hold fasterners 12.5 mm dia 40 mm long, as per manufacturers instructions over the frame work and preparation of ceiling board including dismantling of existing false ceiling of any thickness with cover fillets complete all as specified and as directed.
M&L for preparation of new ceiling surface and applying two coats of oil bound distemper over one coat of chalk whitening complete all as specified and directed by Engr-in-Charge.
M&L 4mm thick non asbestos pre painted designer fibre cement building fixed or laid/inserted to timber/ GI/ Aluminium framework in ceiling complete all as specified. all as specified.
Dismantling structural steel work including doors, gates but excluding framed truss etc. complete all as specified and as directed.
M&L for mild steel frame work in trusses purlins, posts etc complete using MS angle iron, MS Hollow Square or rectangular sections, flat irons etc complete incl necessary welding cutting to shape & hoisted & fixed in position conforming to Fe 410-W (Gde E-250) quality 'A' complete all as directed & specified .
M&L preparation of new steel surfaces of any description over 10cm width or girth not otherwise described and apply two coats of synthetic enamel paint over & including M&L one coat of red oxide zinc chrome primer complete all as specified & directed
M&L for complete removal of existing treatment on wall and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior emulsion paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over applying 1.50 to 2.00 mm thick wall care putty including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises.
M&L for dark shade coloured Vitrified Ceramic tiles 10 mm thick double charged area of each tiles not exc 0.36 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with over & including 15mm thick screed or bedding layer mortar in CM 1:4 complete all as specified and as directed.
All as per Sl. Item No.65.00 here-in-above, but as in skirting over and including 10 mm thick backing coat in CM 1:4
M&L for 25 mm thick Plain cement concrete 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregate) as in sub base of flooring, including. finishing the surface even & rough to receive tiling etc., complete all as specified and directed.
BEYLIM INFRA (BID ID -3348545)
M/S KAUTILYA GARG (BID ID -3354412)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .