| 1 | L1₹41.1 LAccepted-AOC 0 TANDA VILLAGE KHAIRPUR TANDA AYODHYA VILLAGE TOWN POST MAKHDOOM NAGAR CITY AMBEDKAR NAGAR AMBEDAKAR NAGAR UTTAR PRADESH 224190 INDIA | AMBEDKAR NAGAR | UTTAR PRADESH | 224190 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹45.5 L+₹4.2 L (10.1%)Rejected-Finance HQ CWE AHMEDABAD | GANDHINAGAR | GUJARAT | 382006 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹45.6 L+₹4.2 L (10.2%)Rejected-Finance PLOT NO 626 627 GIDC BEHIND GANGOTRI DIARY PORBANDAR 360 577 | PORBANDAR | GUJARAT | 360577 | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹47.0 L+₹5.7 L (13.7%)Rejected-Finance KUCHHADI VADI VISTAR PORBANDAR GUJARAT 360579 | PORBANDAR | GUJARAT | 360579 | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹49.1 L+₹7.7 L (18.6%)Rejected-Finance | L5 | Rejected-Finance Being L5 |
Tender Value
₹41.5 L
EMD Value
₹83,000
Closing Date
5 Dec 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
LT COL UTKARSH SHARMA
OPP BIRLA FACTROY GE (I) CG PORBANDAR
ADDITION/ALTERNATION AND IMPROVEMENT TO BUILDING No. P-16 AT CGDHQ-1 UNDER GE I CG PORBANDAR
2023_MES_627227_1
8941/E8
Open Tender
Civil Works
Item Rate
180 days
PORBANDAR
AS PER NIT
8 documents required · 8 mandatory
₹500
GE I CG PORBANDAR
₹83,000
Yes
18 Dec 2023
7 Nov 2023
7 Dec 2023
7 Nov 2023
5 Dec 2023
22 Nov 2023
Amount
SCHEDULE 'A' B/R ITEMS
Demolition of brick work or stone masonary built in cement mortar including all quoins, arches, pillars, etc., complete all as specified and directed by Engineer-in-Charge.
Dismantling of stone slabs and tiles of any description or thickness laid, bedded and pointed in any mortar and in any position etc., complete all as specified and directed by Engineer-in-Charge.
Material & Labour for Porbandar stone masonry, well bonded, bedded and solidly hearted built in Cement Mortar 1:6, complete all as specified and directed by Engineer-in-Charge.
Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles and rubbish off the premises, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for Vitrified Light shade, Double charged ceremic tiles 10mm thick (square/rectangular) polished area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over screed bed or bedding layer of mortar 15mm thick with Cement Mortar 1:6, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for Vitrified Light shade, Double charged ceremic tiles 10mm thick (square/rectangular) polished area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm as in Skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over bedding layer/ rendering of mortar 10mm thick with Cement Mortar 1:4, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for non skid coloured designer ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with and including 15mm thick screed bed in Cement Mortar (1:4), complete all as specified and directed by Engineer-in-Charge.
Material & Labour for glazed coloured ceramic tiles in verticle surfaces 350x250x7 mm/450x 350x 7mm thick set and jointed in neat cement slurry and pointed in coloured cement to match over screed bed or bedding layer 10mm thick with cement mortar 1:4 and pointed in white or coloured cement to match, complete all as specified and directed by Engineer-in-Charge.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for 75mm thick cement concrete type C – 1 (1:3:6) using 20mm graded stone aggregate as in plinth protection etc., complete all as specified and directed by Engineer-in-Charge.
Material & Labour for 18 to 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over screed bed or bedding layer of 15mm thick with cement mortar (1:6) etc., complete all as specified and directed by Engineer-in-Charge.
Taking down cement plaster of any description and in any position, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for rendering 10mm thick on fair face of brick work or concrete surfaces in Cement Mortar 1:6 finished even and smooth wiithout using extra cement, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for rendering 15mm thick on fair face of brick work or concrete surfaces in Cement Mortar 1:4 finished even and smooth wiithout using extra cement, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for rendering on ceiling 5mm thick in Cement Mortar 1:3 on brick work or concrete surfaces finished fair and even without using extra cement, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for preparation of new plastered or unplastered surfaces and applying two coats of oil bound distemper on wall over a coat of alkali resistant primer over two coat of wall care putty (water proof), complete all as specified and directed by Engineer-in-Charge.
Material & Labour for preparation of new plastered or unplastered surfaces and applying two coats of oil bound distemper on ceiling over a coat of alkali resistant primer, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for preparation of new/old plastered surfaces of wall and applying two coats of 100 % Premium acrylic emulsion paint having VOC less than 50 gm/ltrs and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm all as per the manufacturers instructions, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for complete removal of existing treatment and two coats of oil bound distemper on wall over a coat of alkali resistant primer over two coat of wall care putty (water proof), complete all as specified and directed by Engineer-in-Charge. Note:- after painting cleaning of all floors, glass, Supply & Fixing furniture by own arrangement
Material & Labour for complete removal of existing treatment and two coats of oil bound distemper on ceiling over a coat of alkali resistant primer, complete all as specified and directed by Engineer-in-Charge. Note:- after painting cleaning of all floors, glass, Supply & Fixing furniture by own arrangement
Supply only water proofing compound (integral), complete all as specified and directed by Engineer-in-Charge.
Taking down chowkhat with shutters (without taking of shutters from the frames of any description not exceeding 1.5 Sqm in each panel, complete all as specified and directed by Engineer-in-Charge.
Taking down chowkhat with shutters (without taking of shutters from the frames of any description exceeding 1.5 Sqm but not exceeding 4.0 Sqm in each panel, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing 2nd class HW plain chowkhats and framed, rebated on the solid rounded or chamfered put together with glue pinned at joints, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing 35mm thick Second class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc., divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers, edges of framing plain, chamfered or rounded, fitted with cut mitred beads for securing glass etc. as specified in SSR Part I, Section 8, clause 8.20 (a), complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing 40mm thick Flush Shutter, solid core construction, with block board core and plywood face panels, both face is covered with decorative face veneer with lipping/ frame to match commercial type on both side, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing 30mm thick factory made 100% solid WPC (Wood polymer composite) Solid Plain/Prelam/Enrouted Plain/Enrouted Painted flush Door Shutter of required size comprising of Virgin PVC resin of K Value 57-60 (Suspension Grade), Calcium carbonate and natural fibers (Wood Powders/rice husk/Wheat husk) and Non toxic additives made from Extrusion process WPC foam sheet single Extruded (Inner) with density not less than 650 Kg/cbm manufacture by an ISO 9001-2015 Certified Company, having good screw holding capacity (Screw withdrawl strength of 2000 N (face) & 1100 N (Edge), Minimum Compressive Strength of 50 N/mm2, Modulus of elasticity 850N/mm2 and resistance of spread flame of Class A category with Property of being Termite/Borer Free, Water/Moisture Proof, Fire Retardant and fixing with Stainless Steel butt hinges of required size with necessary full body threaded star headed counter sunk SS Screws for WC/Bathroom/Toilet/Kitchen/Balcony Doors, complete all as specified and directed by Engineer-in-Charge.
Providing and Fixing factory made 100% Solid WPC (Wood Polymer Composite)- Door frame of size 75mmx50mm made from wood Polymer Composite (Single Extruded process ) material comprising of virgin PVC polymer of K Value 57-60 (Suspension Grade), Calcium carbonate and Natural Fibers (Wood Powder/Rice Husk/Wheat Husk) and Non toxic additives fabricated with meter joints after applying PVC solvent cement & Screwed with full body threaded star headed screws having minimum frame density of 780 Kg /cbm manufacture by an ISO 9001-2015 certified Company, having good screw holding capacity (Screw withdrawal strength of (Min 990N), Minimum Compressive Strength of 58 N/mm2, Modulus of elasticity 900N/mm2 and resistance to spread of flame of class A category with property of being termite/borer proof, water/Moisture Proof & Fire retardant & Fixed in position with SS Draft Fasteners/Hold Fast of required dia and length for WC/Bathroom/Toilet and external uses, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing factory made uPVC white colour Sliding window Three track made of extruded profiles with wall thickness of 2.3mm (±0.2mm). Window profile with hollow section with multi chamber, frame (88mm x 52mm), sliding sash (42mm x 67mm), sliding interlock (one vertical length in each shutter)(45.5mm x 28mm), glazing bead (24.5mm x 16mm) will be mitered cut and fusion welded at all corners, including railing of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware, EPDM gasket. 1.2 ±0.2mm thick galvanized steel frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm) 2nos, sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100m long fastener. Hardware (touch lock of zinc alloyed (white powder coated), steel roller system, stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories, complete all as specified and directed by Engineer-in-Charge. Note: The unit rate excludes cost of glass and includes all other connected accessories) area not exceeding 2.00 sqm each fixed from ground floor to height of 2nd floors.
Supply & Fixing 7mm thick Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size 75x75 mm for fixing and operation of handles and fixing approved anodised aluminium standard C section around the opening, make "Decogrill" model DG 104 fixed from ground floor to height of 2nd floors, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing 100mm long medium weight, cold rolled stainless steel Butt hinges and fixed, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing 150mm long Extruded Aluminium alloy handles, fabricated type, anodised, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing 150mm long Aluminium, anodised, barrel tower bolts of extruded section, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing 300mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast Aluminium alloy, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing 100mm long aluminium anodized floor door stopper double legged with rubber shoe, fixed to bottom rail of door, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing staineless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.4mm and fixed with aluminium/pvc sections, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing 4mm thick ordinary quality glass, pin headed type and glazing with oil putty in squares not exceeding 0.5 Sqm in each pane, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing 4mm thick ordinary quality glass, pin headed type and glazing with oil putty in squares exceeding 0.5 Sqm in each pane, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing 3mm thick Figured glass, pin headed type and glazing with oil putty in squares not exceeding 0.5 Sqm in each pane, complete all as specified and directed by Engineer-in-Charge.
Material & labour for preparation of new or previously treated wood surfaces of any description, over 10 cm width or girth, not otherwise described appling one coat of pink primer and applying two coat of synthetic enamel paint, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing 300mm long MS ordinary rat tail rod pattern springs incl roller and roller, complete all as specified and directed by Engineer-in-Charge.
Dismantling of boarding, any description fixed in any position with nails i.e. in cupboard shutters, partitions and similar position, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing 25mm thick flush shutters, solid core construction, with block board core and both faces covered with decorative face veeners with lipping / frame to match, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for 1.5mm thick Decorative laminate type 1 of surface finish, colour and pattern as approved, fixed with approved adhesive as per manufacturer's instructions on 18mm thick calibrated plywood of , grade BWR, type BB, fixed with screws to timber frame work, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing continous piano hinges mild steel bright finish or galvanised of 30mm width, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing 100mm aluminium anodised Hasp and staple, safety type, complete all as specified and directed by Engineer-in-Charge.
Taking up or down steel tubing and connections, including cleaning for refixing or removal to store 15mm dia, complete all as specified and directed by Engineer-in-Charge.
Supply and laying of CPVC pipes, of 20mm dia SDR -11 including plain CPVC SDR fittings for Hot/cold water for sizes (outer dia ) mentioned below including all fittings and solvents and special fittings like brass elbow, brass tee, male threaded brass adaptor, female threaded brass adaptor etc, Unions, Flange and tank adapter all asper manufacturers recommendations and complete all as specified and directed by Engineer-in-Charge.
Taking up or down steel tubing and connections, including cleaning for refixing or removal to store 20mm dia, complete all as specified and directed by Engineer-in-Charge.
Supply and laying of CPVC pipes, of 25mm dia SDR -11 including plain CPVC SDR fittings for Hot/cold water for sizes (outer dia ) mentioned below including all fittings and solvents and special fittings like brass elbow, brass tee, male threaded brass adaptor, female threaded brass adaptor etc, Unions, Flange and tank adapter all asper manufacturers recommendations and complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in repair 15mm bore pillar taps, cast copper alloy fancy type with captain heads chromium plated screw down high pressure with long screwed shanks and fly nuts screwed for iron pipe and fixed, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in repairs Hand Shower (health faucet) 15 mm bore with 1 meter long easy flex tube in chrome finish and wall hok with NRV (Back Flow Preventer), complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in repair Vitreous china wash basin, white, size 600 x 360x 95 mm including waste pipe, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in repair 38mm dia PVC (flexible) waste pipe, 800mm long for urinal, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in repair EWC one piece with integrated cistern with soft closing seat cover and twin flush fittings size 690 x 375 x 785 ,white in colour, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing for 15 mm dia Brass CP mixer for mixing hot & cold water screwed down for iron pipe and fixed, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in repair 15mm bore Bib taps, with flange chromium plated cast copper alloy with capstan head, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in repair 15mm Angle Cock, fancy type, brass chromium plated, screwed down, high pressure, with capstan head, screwed both ends for iron pipe or for unions and fixed, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in repair Tubular towel rail CP Brass, 60cm long between flanges, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing Toilet Roll Holder with flap, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing Soap Dispenser holder, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in repair 7" over head shower with 225mm with flange, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in repair stainless steel grating doom 100 mm dia, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in repair PVC connections 15mm size with PTMT nuts of length 450mm, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in repair 110mm dia PVC rain water pipe of pressure single socketed with rubber joint, jointed with solvent joint fixed to wall, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in repair 75 mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4), complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in repair PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls/trench of bore 110mm (rates includes for making good disturbed surfaces), complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in repair PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls/trench of bore 75mm (rates includes for making good disturbed surfaces), complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing PVC (SWR) bends any radius of 75mm bore, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing PVC (SWR) bends any radius of 110mm bore, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing PVC(SWR) vent cowl as specified of dia 75mm bore, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing Anodised aluminium snap grid framed(size 605mm x 605mm) work for false ceiling and including hangers 6mm dia G.I (upto 1200mm long) adjusting level fixed to roof slabs/purlin/rafter with the help of cleats made out of G.I flat 40mm x 3mm size 60mm long and expansion holdfastener 12.5mm dia 40mm long, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing False ceiling with gypsum board, perforated type, and acoustic purpose, factory made matt finish surface, 600mm x 600mm in size and 12mm thick, complete all as specified and directed by Engineer-in-Charge.
Demolition of reinforced cement concrete of any descritption and in any position not otherwise speccifically provided, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for RCC 1:2:4 Type B-1 (20mm graded aggregate) in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for precast RCC 1:2:4 Type B-1 (using 20mm graded crushed stone aggregate) as in manhole and drain cover slab and similar article with plain faces, set in cement mortar 1:4, including necessary formwork, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for formwork of soffits of suspended slabs such as roof slab, floor slabs, landigs, shelves and similar work, not exc 200mm thick rough finished surfaces of concrete, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for treatment of sunken floor slab comprising of the following specifications with and including demolition of sunken floors complete all as specified and directed:-
(i) Cleaning the sunken/lowered portion of RCC slab surface (including vertical total depth plus skirting height) of floors by wire brush, chisel out any mortar sticking to the surface and brooming completely. Provision of 40mm thick avg PCC 1:2:4 type B-0 using 12.5mm graded aggregate as in padding concrete to achieve proper slope including cutting holes in bricks or RCC wall for spout.
(ii) Rendering of uneven surfaces with 6mm thick Cement Mortar 1:4 mixed with and including integral water proofing compound Sika Plastocreat plus or equivalent make in Fosroc / Thremax as approved by GE @ 0.2% by wt of cement consumed including filling it with water to check dampness and seppage and where dampness / seppage is noticed, nozzles shall be fixed and grouting carried out.
(iii) All junctions points of side wall where CI/GI/PVC pipes are passing through shall be sealed with epoxy putty Sikaguard 694 F(I) or equivalent make in Fosroc / Thremax as approved by GE.
(iv) After drying putty, wash the slab and sides of sunken portion with water and make it clear and clean.
(v) Applying two coats of polymer modified cementious water proof coating with Sika Topseal 107 or or equivalent make in Fosroc / Thremax as approved by GE in two coats @ 3kg/sqm to sanwiched with glass fibre reinforcemnt: Sika Fab-1 or Fosroc / Thremax as approved by GE over base coat as per mnaufacturer's instruction to bottom and vertical sides up to finished floor level +100mm height. The thickness of two layer shall be 1mm. When the second layer is still sticky, coarse sand spray shall be carried for the vertical and bottom surface of the sunken portion.
(vi) Plaster the bottom and sides up to bottom of the skirting with minimum 20mm thick Cement Mortar 1:4 mixed with integral water proofing compound SIKA plastocreat plus or equivalent make in Fosroc / Thremax as approved by GE @ 0.2% by wt of cement consumed as per manufacturer's specification including rounding of corners and injuctions sloping towards spout.
(vii) All pipes laid in sunken portion shall be covered with 50mm thick PCC 1:3:6 type C-2, all round after painting with anticorrosive paint.
(viii) The sunken floor shall be filled with lean concrete 1:7:12.
Note :- Test the water proofed area (ponding test) by filling water for at least 72 hours and tested for leakage seepage and to the entire satisfaction of GE. Test record for each sunken slab shall be maintained. The treatment shall be carried out by authorised applicators of chemicals. Cost of testing and all Material & Labour is inclued in the rates quoted above.
Chipping of loose/ damaged /cracked / previously repaired / delaminated or weak concrete by chieseling to expose the sound core concrete wherever required and to expose rusted reinforcement upto depth not exceeding 50mm and disposal of rubbish off the premises to a distance not exceeding 50 mtrs including cleaning of reinforced concrete surface by air compressor, complete all as specified and directed by Engineer-in-Charge.
Supply and apply of rust remover cum passivator to remove rust from existing reinforcement by using product: Rustoff-100 of Sika or Fosroc/ Thermax as approved by GE, with density 1.01 Kg/ltr at 30 degree celsius and consumption : 0.2 Kg/Sqm/coat, complete all as specified and directed by Engineer-in-Charge. Note: The material to be applied thoroughly on exposed rebars only with the help of a brush of suitable size. The area will be measured as length of bar x two times the dia of bar).
Supply and apply a cement based polymer modified rebar corrosion protection system to existing reinforcement using cement based polymer modified rebar corrosion protection system with consumption : 3.75 kg/Sqm for two coats and Product requirements: carbonation resistance: 2 mm of SikaTop Armatec®-108 of Sika or Fosroc / Thermax as approved by GE corresponds to 20 mm of normal mortar; bond strength > 1N / Sqmm according to ASTM C 882-78, complete all as specified and directed by Engineer-in-Charge. Note: The material to be applied thoroughly on exposed rebars only with the help of a brush of suitable size. The area will be measured as length of bar x two times the dia of bar.
Material & Labour for Providing, mixing & applying two component Epoxy resin concrete Bonding coat on prepared RCC surfaces as per manufacturer's specification including prepartaion of surface throughly and cleaning complete where ever required with using Product: Sikadur®-32 LP of Sika or Fosroc / Thermax as approved by GE with Consumption: 0.4 kg/Sqm and Product requirements: Complies with ASTM C 881-78, Type II Grade 2 Class B+C, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for providing by mixing and trowel application of prepacked, light weight, two component structural grade polymer modified fibre reinforced thixotropic cement mortar Sika Monotop 122F of Sika or Fosroc / Thermax as approved by GE at any average thickness exceeding 10mm and upto 25mm to the prepared concrete surface in soffit of slabs, beam, columns, parapets, fins and facias at any height, including finishing of applied Polymer mortar as per the technical specifications and manufacturer's instructions, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for providing by mixing and trowel application of prepacked, light weight, two component structural grade polymer modified fibre reinforced thixotropic cement mortar Sika Monotop 122F of Sika or Fosroc / Thermax as approved by GE at an average thickness of upto 10mm to the prepared concrete substrate in soffit of slabs, beam, columns, parapets, fins and facias at any height including finishing of applied Polymer mortar as per the technical specifications and manufacturer's instructions, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for Providing, fixing shear connector of 10mm dia TOR steel upto 160 mm length with Sika anchorfix @ -2+ Tropical or Fosroc / Thermax as approved by GE, epoxy resin to RCC member including power drilling, cleaning of holes, insertion of epoxy, placing shear connector in position to ensure the bond as per manufacturer’s instructions, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for weld-mesh of size 75x75x3mm to be wrapped on the exposed surface of rib of beam & on the slab bottom and tack welding to the exposed reinforcement at close intervals and gunite with cement mortar 1:3 mixed with admixture Sika Plasto creat plus or Fosroc / Thermax as per manufacturer's instructions as approved by GE around rib of beam or roof slab of thickness n.exc 40mm to be applied under an operating pressure. The gunited surface to be cured properly for a min of 7 days all in complete as per the technical specifications and manufacturer's instructions, complete all as specified and directed by Engineer-in-Charge.
Providing and erecting hydraulic & manual steel props upto full height, braced at centre, resting on wedge and block to support the structure provisionally during repair work and maintaining them in position till required and complete all as specified and directed by Engineer-in-Charge. Note : Hydraulic & manual steel props will be provided, erected and maintain the interval distance of steel props c/c at site on the basis of site reqmt as per direction of Engr-in-Charge.
Providing and fixing water tight centering and shuttering including bolting, strutting, propping etc. including removal of form work from column, beam etc., complete all as specified and directed by Engineer-in-Charge.
Supply and apply a ready to use non shrink, cementitious free flow micro-concrete (<100 mm) using Product: SikaRep® Microcrete-4 + adequate coarse aggregate, Yield: approx 17 Ltr/bag (30 Kg) (depending on the size and quantity of coarse aggregate added), Product : SikaRep® Microcrete-4 or Fosroc / Thermax as approved by GE, Product requirements: compressive strength > 60 N/Sqmm (28 days) according to ASTM C 1107-99, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for providing and application of one coat of Water based concrete curing compound with low viscosity wax emulsion using Sika Antisol E - WP of Sika or Fosroc / Thermax as approved by GE, as concrete curing membrane over the applied polymer mortar as temporary curing membrane as per the technical specifications and manufacturer's instructions, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for Mild steel CRS TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire annealed not less than 0.9mm dia or securing with clips, complete all as specified and directed by Engineer-in-Charge.
-ditto- all as per item No. above, but 6mm to 8mm dia. complete all as specified and directed by Engineer-in-Charge.
-ditto- all as per item No. above, but 5mm dia and over upto 10mm dia as in stirrups, spacers and binders, complete all as specified and directed by Engineer-in-Charge.
Roughening surfaces of old concrete floor by picking sweeping cleaning & washing down with water to remove dust etc., including removal of old treatment of any description and applying one coat of neat cement slurry @ 3.00 Kg/Sqm, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for 40mm thick cement plain cement concrete type B-0, 1:2:4 (12.5 mm graded aggregate), complete all as specified and directed by Engineer-in-Charge.
Providing cement concrete 1:3:6 type C-1 using 20 mm graded stone aggregate as in roof kerbs, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for providing APP based membrane course roof treatment in layers with following provisions:- (i) Applying one coat of bitumen's primer polymerized primer oil based coat, evenly @ 0.3KG/Sqm as priming coat to the prepared surfaces, till the surfaces is properly impregnated and the solvent oil in the base primer shall be allowed to evaporated completely. (ii) Applying APP based pre-fabricated with non woven polyester reinforced membrane stabilized with fibre glass strands and top with grey mineral slates 3mm thick and weight not less than 3.50 Kg/Sqm by torch application method. (iii) Applying a coat of solar reflective bituminous aluminium paint @ 0.10Kg/Sqm over mineral surface.
Supply & Fixing in repair 1000 Ltrs. Capacity rotational moulded polyethylene water storage tanks (cylinder vertical with class top) hoisted and fixed in position all as specified including 20mm bore ball brass valves, high pressure, with polythene float and flynut, screwed for iron pipe or brass ferrule and fixed, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in repair sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete with waste coupling and waste pipes of suitable capacity, complete all as specified and directed by Engineer-in-Charge.
Dismantling asbestos cement corrugated or semi corrugated sheets as in roof covering, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing Pre-painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws, complete all as specified and directed by Engineer-in-Charge.
Dismantling wrought iron or mild steel work of any description not otherwise provided, for MS railing at passage, stair and rear sitouts, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for rolled sections as in tubular trusses / rafter / purlin fixed with angle cleats or other connecting plates confirming to FE-410 (Gde-E-250), complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment including welding etc., Fe-410-W(gde-E-250) quality B, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing mild steel bolts, purpose made, with hexagonal or square head one end and screwd the other, or screwed both ends, each screwed end to be fitted with washer and one hexagonal or square nut exc 30cm long diameter of neck exc 12mm, complete all as specified and directed by Engineer-in-Charge.
Material & Labour for stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing 12mm thick toughened sheet glass for railing and fixed with patch fittings of SS 316 grade, necessary accessories for fixing including cutting holes of any size in floor and wall, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing in repair Plate racks made out of 1mm thick. Stainless steel of size 750mm x 600mm x 250mm, complete all as specified and directed by Engineer-in-Charge. Make:- SAIL, IINDAL, SURAJ
Supply & Fixing Solid PVC Wall Lining consisting of 5mm thick Plain /preleam colour PVC sheet inclusive of solvent cement and fixing at site on wall as per specifications and drawing, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing, complete all as specified and directed by Engineer-in-Charge.
SCHEDULE 'A' E/M ITEMS
Taking down carefully aluminium/copper point wiring (light, fan, socket or power) concealed and casing caping complete including fittings and fixtures such as switches, ceiling roses, pendants, regulators, sockets light fittings and making good the disturbed surfaces of walls/ceiling/floor etc., complete all as specified and directed by Engineer-in-Charge.
Disconnecting of unserviceable sub main wiring of any size and including steel conduit and accessories & removing from site and making good the disturbed surfaces, complete all as specified and directed by Engineer-in-Charge.
Disconnecting electric connections and taking down old unserviceable MCB DBs of any capacity including MCBs, complete all as specified and directed by Engineer-in-Charge.
Taking down Ceiling fan & blades and deposit to E/M store, complete all as specified and directed by Engineer-in-Charge.
Material & labour for Point wiring complete with 1.5 Sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS cable 650/1100 Volts grade drawn through and including non metallic rigid PVC heavy duty concealed conduit (minimum 20 mm dia external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR part- I ISI marked with wall thickness not less than 1.8 mm including conduit accessories like bends, tees, junction boxes etc fixed concealed/ recessed in wall or ceiling etc including 1.5 sqmm PVC insulated but unsheathed multistranded copper conductor FRLS cable as earth continuity wire including modular type metal flush box with cover plate and frame of required modules for mounting of modular switches, sockets, switch sockets, fan regulators with required modules all as specified etc for the following:-
One light point controlled by one, one way switch
One fan point controlled by one, one way switch
One 3 pin 6 Amps socket outlet on same board
One 3 pin 6 Amps socket outlet on independent board.
Material & Labour for Point wiring complete with 2.5 Sqmm single core PVC insulated but unsheathed multistrand copper conductor FRLS cabeI 650/1100 Volts grade conforming to IS-694 drawn through PVC conduit (minimum 20 mm dia (external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR Part I) ISI marked with wall thickness not less than 1.8 mm heavy duty including conduit accessories concealed pressed steel terminal boxes of size cover white/coloured including 2.5 Sqmm PVC insulated but unsheathed copper conductor FRLS cable as earth continuity wire for one 3 pin 15 or 16 Amps socket outlet on independent board, including modular type metal flush box with cover plate and frame of required module for mounting of modular switches, sockets, switch sockets with required modules, complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement modular switch 1 way, 6 Amps, 1 module (ISI marked), complete all as specified and directed by Engineer-in-Charge. Make : Legrand / Anchor (Roma)/ L&T
Supply & fixing in replacement modular switch 1 way, 16 Amps, 1 module (ISI marked), complete all as specified and directed by Engineer-in-Charge. Make : Legrand / Anchor (Roma)/ L&T
Supply & fixing in replacement modular socket, 6 Amps, 2/3 pin combind 2 module (ISI marked), complete all as specified and directed by Engineer-in-Charge. Make : Legrand / Anchor (Roma)/ L&T
Supply & fixing in replacement modular socket, 6/16 Amps, 2/3 pin combind 2 module (ISI marked), complete all as specified and directed by Engineer-in-Charge. Make : Legrand / Anchor (Roma)/ L&T
Supply & fixing in replacement modular fan regulator, 120 watt, 2 module (ISI marked), complete all as specified and directed by Engineer-in-Charge. Make : Legrand / Anchor (Roma)/ L&T
Supply & fixing in replacement ceiling rose, surface bakelite, 65 x 17 mm three terminals (ISI Marked), complete all as specified and directed by Engineer-in-Charge. Make : Legrand / Anchor (Roma)/ L&T
Supply & fixing Buzzer, Ding dong, AC 230Volts single pole, complete all as specified and directed by Engineer-in-Charge.
Supply & fixing Modular Bell push 6A 1 module, complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement in of wall mounted LED Tube light fitting 1 x 20W LED (6500K), 4 feet, Sleek and seamless profiled extruded aluminium batten with an efficient diffuser to illuminate work, including making connections with 2 core flexible copper wire 0.50 Sqmm from ceiling rose after fixing fitting, complete all as specified and directed by Engineer-in-Charge. Make:- Philips/ Wipro / Bajaj
Supply & fixing in replacement wall mounted LED Tube light fitting 1 x 10W LED (6500K), 2 feet, Sleek and seamless profiled extruded aluminium batten with an efficient diffuser to illuminate work, including making connections with 2 core flexible copper wire 0.50 Sqmm from ceiling rose after fixing fitting, complete all as specified and directed by Engineer-in-Charge. Make:- Philips/ Wipro/GE Lighting
Supply & fixing in of LED fitting 36W LED (5700K), Sleek and seamless with an efficient diffuser to illuminate work, including making connections with 2 core flexible copper wire 0.50 Sqmm from ceiling fixing fitting, complete all as specified and directed by Engineer-in-Charge. Make:- Philips/ Wipro/GE Lighting
Supply & fixing LED 25 Watts (5700K) Bldg Security light fitting, and including with GI Pipe 32 mm dia bracket with connected with 2 core flexible copper wire 0.50 Sq mm from ceiling rose after fixing fitting in position at site, complete all as specified and directed by Engineer-in-Charge. Make: Wipro /Philips /CG
Supply and fixing LED surface downlighter lights fitting 1x 15W, 220V, 105lmns/W, (170x170mm dia) AC decorative box/round type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and directed by Engineer-in-charge. Make: Philips/Wipro/bajaj
Supply & fixing BEE five star rated BLDC energy efficient high-speed ceiling fan having 1200mm blade sweep, air-flow not less than 210 CMM, operating voltage 220-240 V and frequency 50 Hz, including a downroad of suitable size and electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fan, complete all as specified and directed by Engineer-in-charge. Make: Crompton /Orient Cat No Tome/ Havells
Supply and fixing Decorative LED lights fitting 5 x 42W, 220V, decorative box/round type with driver, connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and directed by Engineer-in-charge. Make:- Philips /Wipro/bajaj
Material and labour for sub main wiring with two single core 2 x 4 Sqmm PVC (FRLS) insulated multistranded flexible copper conductor cable 660/1100 volts grade down in through including Concealed PVC Conduit with all accessories, PVC insulated 1 x 4 Sqmm single core single strand copper conductor as continous earth wire in green colour connected to common earth dolly, including taking down old unserviceable wiring, complete all as specified and directed by Engineer-in-Charge. Note : 1. Two runs of cable, one run of earth wire, one run of PVC conduit will be measured and paid one unit.
Material and labour for sub main wiring with two single core 2 x 6 Sqmm PVC (FRLS) insulated multistranded flexible copper conductor cable 660/1100 volts grade down in through including Concealed PVC Conduit with all accessories, PVC insulated 1 x 6 Sqmm single core single strand copper conductor as continous earth wire in green colour connected to common earth dolly, including taking down old unserviceable wiring, complete all as specified and directed by Engineer-in-Charge. Note : 1. Two runs of cable, one run of earth wire, one run of PVC conduit will be measured and paid one unit.
Supply & fixing in replacement MCB DB 12 way SPN, (Acrylic door), IP 43 “Weather proof” Concealed/ Surface mounted and making good the disturbed surfaces of walls/ceiling/floor etc. complete with all accessories, main switch and connecting the cables with proper, complete all as specified and directed by Engineer-in-Charge. Make: Legrand / L&T / Schneider
Supply & fixing in replacement VTPN DB 4 way, (Acrylic door), IP 43- “Weather proof” Concealed/ Surface mounted and making good the disturbed surfaces of walls/ceiling/floor etc. complete with all accessories, main switch and connecting the cables with proper, complete all as specified and directed by Engineer-in-Charge. Make: Legrand / L&T / Schneider
Supply and fixing in replacement of MCB SPN, 240 volt, 32 Amps, complete all as specified and directed by Engineer-in-Charge. Make : Legrand/ Havells/ ABB .
Supply and fixing in replacement of MCB TPN, 240 volt, 100Amps, complete all as specified and directed by Engineer-in-Charge. Make : Legrand /L&T/Schneider
Supply and fixing in replacement of MCB SP, 240 volt, 6 to 32 Amps, complete all as specified and directed by Engineer-in-Charge. Make : Legrand/ Havells/ ABB
Supply & Fixing Modular Motor starter 16A capacity, 02 Module with metal flush box, cover plate of required module for ACs, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing Co-axial TV socket, One Module, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing double RJ-11 telephone socket (Jack type) with shutter, One Module, complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in replacement 415V 10KA 'B' curve miniature circuit breaker (MCB) of TP 25 to 63Amp current carrying capacity in the DB complete with connection testing and commissioning., complete all as specified and directed by Engineer-in-Charge.
Supply& Fixing rigid non metallic 25mm dia PVC conduit exclusive of boxes (Junction/terminal) but inclusive of all Tee, bends, elbow reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook etc., complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing junction boxes (1 to 4 way) with cover plates and accessories, complete all as specified and directed by Engineer-in-Charge.
Cutting chases, pinning in, making good to facings where required of brick/stone wall and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc. and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting exceeding 20cm girth, complete all as specified and directed by Engineer-in-Charge.
Material & Labour in replacement for Earthing complete with GI earth plate 60cmx60cmx6mm thick electrode and 4mm dia GI wire as earthing lead burried directly in ground (earth pit not less then 2.25 metres deep below ground level ) with top edge of the plate not less then 1.5 metres below normal ground level. connected to GI wire earth lead 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 and including earth work, PCC pit and RCC cover, watering pipe 20mm dia light grade, funnel, wire mesh, protection pipe 15mm dia light grade up to 7.5 mtr length of earth wire, charcoal dust and salt etc. and connected to earthing test point all as specified or directed and testing, complete all as specified and directed by Engineer-in-Charge.
roxy enterprise
K K Construction Co
JAY BHARAT METAL SUPPLIERS
RUDRAAY CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .