CWE
HQ CWE Rajouri PIN-900129 C/o 56 APO
REPAIRS TO CERTAIN AC PLANTS AND CONNECTED ITEMS AT RAJOURI UNDER GE 862 EWS
2022_MES_546403_1
CANO-CWE/RAJ-42/2022-23
Open Tender
Support/Maintenance Service
Item Rate
180 days
Rajouri under AoR of GE 862 EWS
Class E category c(i)
9 documents required · 9 mandatory
₹500
GE 862 EWS
₹10,000
Yes
21 Nov 2022
20 Aug 2022
1 Oct 2022
20 Aug 2022
24 Sept 2022
10 Sept 2022
Amount
M&L for cleaning of shell and tube water cooled condensers of the A/C plants of following capacities after dismantling the water lines and headers and cleaning with suitable wire brush and washing soda to remove the dirt and water scaling and refixing the water lines and headers including provision of new gaskets, in every 04 moths etc complete all as directed by Engr-in-Charge.Note:- Cost of tramsportation and all petty spares required/from dismantling to recommisioning deemed to be included in the quoted rates.
(a) 12.5 TR x 4 (50 TR)capacity at U/G Signal Central AC Plant
(b) 10 TR x 3 (30 TR) capacity at 150 GH OT Room
M& L for servicing along with chemicals for pahar pur cooling tower of 60 TR capacity complete all as specified and as directed. Note : Costs of all materials and chemicals required for cleaning and making good are deemed to be included in the quoted rate.
M & L for complete servicing of 01 AHU of 40 TR including chemical cleaning of cooling coils, filters etc. including cost of all chemicals and consumable materials required at site, complete all as specified and as directed.
M & L for complete servicing of 01 AHU of 20 TR including chemical cleaning of cooling coils, filters etc. including cost of all chemicals and consumable materials required at site, complete all as specified and as directed.
Complete servicing of Y strainers of 2 chilled water and 2 condenser water pumps including replacement of strainer mesh all as specified.
Supply and fix in repairs ball / roller bearing for pumps and motors of following capacity including taking down old bearing and re installation at site including testing on completion. Note : Costs of all material and labour required for taking down dismantiling pumps and motors and re-fixing the same in its original postition after repairs are deemed to be included in the quoted rate.
(a) Upto 5 HP capacity
(b) Upto 10 HP capacity
(c) Up to 15 HP capacity
Dismantling the unserviceable electric motor any type or of any capacity upto 5 HP and transporting to reputed workshop, taking out old and burnt winding wire and rewinding with super enameled copper winding wire of existing gauge and size with insulating materials, varnishing and baking etc, re-fixing the same at site and re-alignment, testing and commissioning complete all as directed by Engr-in-Charge. Note:- Cost of tramsportation and all petty spares required/from dismantling to recommisioning deemed to be included in the quoted rates.
Supply and fixing Pressure Guage analog type 0-100 PSI including removing old unserviceable pressure gauge all as specified.
Supply and fixing power contactor TP 415 Volt 50 Amp as required at site including taking down old unserviceable contactor complete all as specified and as directed.
Supply and fixing power contactor TP 415 Volt 10 Amp as required at site including taking down old unserviceable contactor complete all as specified and as directed.
Supply and fixing power contactor TP 415 Volt 15 Amp as required at site including taking down old unserviceable contactor complete all as specified and as directed.
Supply and fixing power contacor TP 415 Volt 125 Amp as required at site including taking down old unserviceable contactor complete all as specified and as directed.
Supply and fix in replacement HRC fuse set 6 Amps all as specified and as directed
Supply and fix in replacement Pressure switch type MP-15 all as specified and as directed
Supply and fix in replacement Pressure control device differantial type all as specified and as directed
Supply and fix in replacement Pressure release valve of size 1/4" all as specified and as directed
Supply and fix in replacement Suction valve of size 3/8" all as specified and as directed
Supply and fix in replacement discharge valve of size 3/8" all as specified and as directed
Supply and fix in replacement copper tubing of existing size at cooling coil assembly complete all as specified and as directed
Supply and fix in replacement liquid lie filter dryer of 42 bar all as specified and directed.
Supply and fix in replacement hand shut up valve brass with iron wheel of size 15mm all as specified and directed.
Supply and fix inreplacement digital meter all as specified and as directed. Make:- Subzero SZ-7556-P-3 or its equivalent make as approved by GE
Servicing to condensor coil assembly including pressure test with nitrogen gas and soldering to leakage with copper soldering machine complete all as specified and as directed
Servicing to Cooling coil assembly including pressure test with nitrogen gas and soldering to leakage with copper soldering machine complete all as specified and as directed
Nitrogen testing for the any capacity of compressors including condensing unit and gas piping complete as per the manufacturer instructiions and entire satisfaction of the Engineer in Charge. Note :- (i) Nitrozen pressure should be held with out any drop in pressure inside the unit continue for 24 hours. (ii) The rate for nitrogen gas are included in the quoted rates.
Supply and filling Refrigerant gas R-407 for AC plant compressor all as specified and as directed.
Supply and filling Refrigerant gas R-22 for AC plant compressor all as specified and as directed.
Supply and fixing in replacement of MCCB FP 415 volts AC , 100 Amps breaking capcity 25 KA, all as specified and as directed.
Supply and fixing in replacement of MCCB FP 415 volts AC, 125 Amps breaking capcity 25 KA, all as specified and as directed.
Supply and fixing in replacement of MCCB FP 415 volts AC , 160 Amps breaking capcity 25 KA, all as specified and as directed.
Supply and fixing in replacement of MCCB FP 415 volts AC , 200 Amps breaking capcity 36 KA, all as specified and as directed.
Supply and fixing in replacement of MCB SP 240 volts AC , 6-32 Amps breaking capcity 10 KA, all as specified and as directed.
Supply and fixing in repair of MCB TP 415 volts AC ,6-32 Amps breaking capcity 10 KA, all as specified and as directed.
Supply and fix in repair Belt for motor B-79 all as specified and as directed
Supply and fix in repair blower motor belt A-26 all as specified and as directed
Supply and fix in replacement strip heater double tube (3KW) for 10 TR package type AC plant complete all as specified and directed. Make : Theta/Dasspass/Airex.
Air filter (HEPA Filter) for package type AC plant complete all as specified and directed.
Supply and fixing of CI butterfly valves with matching flanges,gaskets, hardware duly insulated with preformed pipe section fabricated to shape and bonded with adhesive, removable cover is required valves in 26swg aluminium sheet, cover should be divided in to portions quick release toggles shall be used for assembly of covers. Make :Leader/BIR/Pryag
(a) 32 mm bore.
(b) 80 mm bore.
M&L for servicing monoblock pumps including dismantling and opening the pump, repair/replacement of defective impeller,replace the worn out bearing impeller, stuffing box, back plates, gland packing mechincal seal and rusted nut, bolts etc assembling property , greasing all movable parts, fixing in position, testing and commissioning all as directed for the following HP pumps.
(a) 3 HP to 5 HP Pump
Supply and fixing indicator lamp assembly complete LED type suitable for the existing system supply voltage for the existing system supply voltage 230V / 440 V AC including taking down old lamp assembly complete all as specified and directed. . Make – Mimic control/AEC/C&S.
Dismantling the compresor and taking out the shaft from the compressing unit and taking to the reputed workshop for necessary lathe/ machining work to match the bearing size, cleaning inside the compresing unit and necessary overhauling complete as directed .Installation of compressor and connect with motor , alingment and carrying out of testing to the entire satisfaction of Engr-in-charge for the following compressor model :- Note : defective Spares required to be replaced shall be measured and paid seperately under appropriatre items of this schedule.
(a) 12.5 TR capacity at UG Sig Centre AC Plant
(b) 10 TR Capacity at 150 GH AC Plant
M&L in replacement for providing acoustic lining to the ducting by using FG crown 200x25mm thick rigid board density 32kg/m3 covered with RP tissu & 28G aluminium perforated sheet & using GI nuts, bolts & washer for the entire duct complete all as specified and as directed by Engr-in-charge.
M&L in replacement for thermal insulation of duct using adhesive & FG crown-150 factory laminated covered with aluminium foil of 50mm thickness complete all as specified and as directed by Engr-in-charge.
Repair and maintenance of humidity controller, heater including internal wiring and replace of any part of internal body all as specified and as directed by Engr-in-charge.
M&L in replacement for assembly and erection of GI sheet with TDF flange rectangular/square duct made out of L shaped hollow profile, duly factory boxed, including all accessories such as corner, cleat, carriage bolt, gasket and appropriate sealant on longitudinal joints etc complete of size 22 gauge complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement PVC fins for cooling tower of 60 TR capacity all as specified and directed.
Material and labour in repplacement for earthing complete with galvanised steel earth plate electrode 600mmX 600mmX 6mm thick buried directly in ground vertically ( earth pit not less than 2.25 metres deep below ground level) with top edge of plate not less than 1.5 metres below ground level, connected to and including galvanised iron strip of size 25 X 4 mm from earth electrode to test point or up-to 7.5mtr whichever is less by means of GI bolts, nuts, check nuts and washers all as per electrical plate no 3 of SSR Part-I provision of G I Pipe 40mm bore eight grade for protection of GI strip and GI watering pipe of 20 mm bore medium grade,GI funnel with wire mesh,including char-coal, salt packed all around the earth electrode plate in layers,PCC earth pit chamber 1:3:6 type C1,RCC cover 1:2:4 type B1,excavation,earth work in any strata and returning filling, removal of surplus soil and testing for required value complete all as specified and directed.
Supply and fix in replacement Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed of following capacity all as specified and as directed . Make ESSCO/Janiko/Prayag
(a) 15 mm bore.
(b) 25mm bore.
(c) 40mm bore.
Supply,lay and testing in replacement of cable XLPE insulated,galvanised steel strip armoured,1100 volts grade with multistranded aluminium conductor of cross-sectional area 50 sqmm; 3.5 core laid in trenches/pipes/ducts/walls and connection with necessary cable lugs and glands, nuts, bolts and washers etc and testing including removing old unserviceable item complete all as specified and directed.
Supply,lay and testing in replacement of cable XLPE insulated,galvanised steel strip armoured,1100 volts grade with multistranded aluminium conductor of cross-sectional area 70 sqmm; 3.5 core laid in trenches/pipes/ducts/walls and connection with necessary cable lugs and glands, nuts, bolts and washers etc and testing including removing old unserviceable item complete all as specified and directed. Note for item No 50 and 51 :- (i) The cable shall be in one length.
Supply,lay and testing in replacement of cable Unarmoured PVC insulated,,1100 volts grade with multistranded copper conductor of cross-sectional area 16 sqmm; 4 core laid in trenches/pipes/ducts/walls and connection with necessary cable lugs and glands, nuts, bolts and washers etc and testing including removing old unserviceable item complete all as specified and directed. Note for item No :- (i) The cable shall be in one length
Supply and fix in replacement rigid non-metallic PVC conduit 40 mm dia medium grade including conduit accessories for encasing the cable from panel to machine along wall/roof as directed including sadding as per site requirement with neccessary base saddles all as specified and directed. Make:- Finolex/Prince/Supreme/Precision/Tirupati
M/S PARSHOTAM KUMAR GUPTA
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .