Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.7 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹31.7 L+₹212 (<0.01%)Rejected-Finance | L2 | Rejected-Finance Reject | |
| 3 | Rejected-Technical | - | Rejected-Technical Reject |
Tender Value
₹31.7 L
EMD Value
₹63,495
Closing Date
15 Dec 2022, 10:00 amClosed
Executive Engineer(Agri)
Executive Engineer(Agri), Kokrajhar
Vertical extension of Grade-IV quarter at Agril. campus in Kokrajhar District, BTC
2022_BoTC_27844_1
No. EE(Agri)/Koj/BTC/ e-Tender/2022-23/4367
Open Tender
Civil Works
Works
45 days
Executive Engineer(Agriculture)
Please refer Tender documents.
5 documents required · 5 mandatory
₹2,000
Yes
₹63,495
Yes
12 Jan 2023
21 Nov 2022
15 Dec 2022
21 Nov 2022
15 Dec 2022
22 Nov 2022
22 Nov 2022 - 12 Dec 2022
Amount
Building internal work
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth completed In wall, Ceiling
White washing with lime to give an even shade New work (three or more coats)
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade New work (two or more coats) over and including water.thinnable priming coat with cement primer
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to fS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Glazed vitrified floor tiles polished finish of size Size of Tile 1000x1000 mm Deduction, Toilet floor tiles
Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. Kitchen wall, Toilet wall
Providing and fixing glazed screen printed border tile 75mm wide having thickness 5mm, of approved quality & make, in all shades, design and prints, in dado, over 12mm thick bed of cement mortar 1:3 (1 Cement : 3 Coarse sand) and jointing with grey cement slurry @ 3.3 kg/sqm including pointing with white cement mixed with pigment of matching shade, all complete as approved by Engineer - in - Charge.
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with raw! plugs screws etc. @ 12KG/Sqm W1, W2, W3
Providing and fixing Prelaminated flat pressed 3 layer (medium density) particle board or graded wood particle board IS 3087 marked, with one side decorative and other side balancing lamination Grade 1, Type 1 1 exterior grade IS 12823 marked, in shelves with screws and fittings wherever required, edges to be painted with polyurethane primer (fittings to be paid separately). 18 mm thick
Providing and fixing chromium plated brass 50 mm cupboard or wardrobe knobs with nuts complete,
Providing and fixing chromium plated brass handles with necessary screws etc. complete:
Providing and fixing magnetic catcher of approved quality in cupboard / ward robe shutters, including fixing with necessary screws etc. complete. Triple strip vertical type
Providing and fixing powder coated telescopic drawer channels 300 mm long with necessary screws etc. complete as per directions of Engineer-in- charge,
Providing and fixing sliding arrangement in racks/ cupboards /cabinets shutter by with stainless steel rollers to run inside C or E aluminium channel section (The payment of C or E channel shall be made separately)
Providing and fixing cupboard shutter with 19mm thick one side decorative and other side balancing lamination factory pressed BWP grade marine ply as per IS 710 of approved brand including 2mm thick PVC edge banding tape with hot glue by edge bending machine etc. with auto closing spring loaded hinges (hydraulic type) etc. complete as per direction of Engineer-in-charge. (Payment of providing and fixing auto closing hinges shall be paid separately)
Providing and fixing stainless steel soft closing spring hinges at 0 degree hinges (hydraulic type) of approved make/brand to cupboard shutters with full threaded steel screws including making necessary recess in board and finished etc. complete as per direction of Engineer-in-charge
Providing and fixing 2mm thick 16 to 19mm wide PVC edge binding tape of approved quality for cupboard / wardrobe shutters including necessary synthetic resin hot pressed to edges on binding machine etc. complete as per directions of Engineer- incharge.
Providing and fixing aluminium tee channels (heavy duty) with rollers & stop end
Providing and fixing ready made 304 grade stainless steel Modular kitchen basket and accessories such as right angle basket (Plain Cup & Saucer, plant, Partition, Bottle rack, Thali, Cutlery) kitchen utensil basket, Dinner set basket, kitchen grain basket, Multipurpose basket as per site requirement including finishing (wherever required) and fittings. The same shall be fixed with necessary stainless steel nuts & bolts, Stainless Steel screws & telescopic channel etc. as per direction of Engineer-incharge. (For payment purpose only weight of Stainless steel basket....... Payment of providing and fixing telescopic channel shall be paid separately)
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent
RCC stair
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineerincharge. All kinds of soil
Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete (a).Brick on flat soling.
CEMENT CONCRETE (CAST IN SITU)(P.C.C)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering ,- All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-Il!) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
Centering and shuttering including strutting, propping etc. and removal of form work for Foundations, footings, bases for columns
Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc.
REINFORCED CEMENT CONCRETE
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement All work up to plinth level 1:1.5:3 (1 cement : 1.5 coarse sand (zone-Ill) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc, above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement: 1:1.5:3 (1 cement : 1.5 coarse sand(zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15 0 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
Providing and laying up to floor five level reinforced cement concrete in kerbs, steps and the like excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-Ill) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
FORM WORK
Centering and shuttering including strutting, propping etc, and removal of form for Foundations, footings, bases of columns, etc. for mass concrete
Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick
Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick
Columns, Pillars, Piers, Abutments, Posts and Struts
Stairs, (excluding landings) except spiral-staircases
Small surfaces such as cantilever ends, brackets and ends of steps, caps and bases to pilasters and columns and the like
STEEL REINFORCEMENT
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position nd binding all complete pto plinth level. Thermo-Mechanically reated bars of grade Fe- 500D or more.
Steel reinforcement for .C.C. work including traightening, cutting, ending, placing in position nd binding all complete bove plinth level. Thermo-Mechanically reated bars of grade Fe- 500D or more.
VITRIFIED FLOOR TILES
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Glazed Vitrified tiles Matt/Antiskid finish of size Size of Tile 1200 x 1200 mm
Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. 20 mm cement plaster
White washing with lime to give an even shade New work (three or more coats)
Finishing walls with Acrylic Smooth exterior paint of required shade New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineerincharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
RCC GATE
Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m. All kinds of soil
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m, Deduct Post (-)
Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete a .Brick on flat soling
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:3:6 (1 Cement : 3 coarse sand (zone-Ill) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
Centering and shuttering including trutting, propping etc. and removal of form work for Foundations, footings, bases for olumns
Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc.
REINFORCED CEMENT CONCRETE
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and r6inforcement - All work up to plinth level 1:1.5A (1 cement : 1.5 coarse sand (zone-Il!) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) Footing, Columns, Tie beam
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse and(zone-lll) derived from natural ources : 3 graded stone aggregate 0 mm nominal size derived from atural sources) Columns
FORM WORK
Centering and shuttering including trutting, propping etc, and removal of form for Foundations, footings, bases of columns, etc. for mass concrete
Lintels, beams, plinth beams, irders, bressumers and antilevers.
Columns, Pillars, Piers, Abutments, osts and Struts
STEEL REINFORCEMENT
steel reinforcement for R.C.C. work lncludlng straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
15 mm cement plaster on rough side of single or half brick wall of mix: 1:4 (1 cement: 4 coarse sand)
PLAIN CEMENT MORTAR BANDS
12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Raised Band
Applying one coat of water thinable cement primer of approved brand and manufacture on wall surfaces. Water thinnable cement primer.
Finishing wall with water proofing cement paint of approved brand and manufacture of required shade. 13.44.1.New work (Two or More coat @ 3.84 Kg/10m2
Steel work welded in built up sections/ framed work, including hosting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required, In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture
CAR GARAGE
Earth work in excavation by echanical means (Hydraulic xcavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 and lift upto 1.5 m, as directed by Engineer-incharge. All kinds of soil
Dry brick pitching half brick hick in drains including supply of bricks and preparing the surface complete (a).Brick on flat soling.
CEMENT CONCRETE (CAST IN SITU)(P.C.C)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-Ill) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
Centering and shuttering including strutting, propping etc. and removal of form work for Foundations, footings, bases for columns
Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc.
REINFORCED CEMENT CONCRETE
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-Il)) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement 1:1.5:3 (1 cement : 1.5 coarse sand(zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up 15 0 landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
FORM WORK
Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete
Lintels, beams, plinth beams, girders, bressumers and cantilevers
Columns, Pillars, Piers, (butments, Posts and Struts
STEEL REINFORCEMENT
Steel reinforcement for R.C.C, work including straightening, cutting, bending, placing in position and binding all compiete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D more
Steel reinforcement for R.C.C, work including straightening, cutting, bending, placing in position and binding all complete above plinth level, Thermo-Mechanically Treated bars of grade Fe-500D more
Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and (3.1. limpet washers or with G.l. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal / vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 1.00 mm thick with zinc coating not less than 275 gm/m2
Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.l. limpet and bitumen washers omplete. 0.80 mm thick with zinc oating not less than 275 gm/m2
Steel work in built up tubular ound, square or rectangular ollow tubes etc.) trusses etc., cluding cutting, hoisting, xing in position and applying priming coat of approved ee' primer, including welding d bolted with special shaped ashers etc. complete. Electric resistance or induction tt welded tubes
FLOORING
62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture's specifications. This includes cost of cement slurry but excluding the cost of nosing of steps etc. complete.
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand (zone-Ill) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
SEPTIC TANK
Earth work in excavation by means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m In width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. All kinds of soil
Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-ill) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
1:3:6 (1 Cement : 3 coarse sand (zone-Ill) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
Centering and shuttering including propping etc. and removal of form work for Foundations, footings, bases for columns
REINFORCED CEMENT CONCRETE
and laying in position grade of reinforced ernent concrete, Providing and laying in postion specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level 1:1.5:3 (1 cement : 1.5 coarse sand (zone-Ill) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
FORM WORK
Centering and shuttering including strutting propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers.
STEEL REINFORCEMENT
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Brick work with common burnt ciay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand)
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in . ( Cement mortar 1:3 (1 cement : 3 coarse sand)
15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix 1:3 (1 cement: 3 fine sand)
Providing, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but , excluding cost of reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zonederived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
Supplying and fixing C.I. cover without frame for manholes 500 mm diameter C.I. cover (medium duty) the weight of the cover to be not less than 58 kg
Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Constructing soak pit 1.20x1.20x1.20 m filled with including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design.
Providing and fixing soil, waste and vent pipes 100mm dia, Sand cost iron S & S pipe as per IS: 1729
Providing and filling the joints with spun yarn, cement slurry and cement mortar 1:2 ( 1 cement : 2 fine sand) in S.C.I./ C.I. Pipes 100 mm dia pipe
DEEP TUBE WELL
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method in IS: 2800 (part 1), including collecting samples from different strata, preparing and Submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. Rocky strata including Boulders 300mm dia
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 150 mm nominal size dia
Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-incharge.
Development of tube well in accordance with IS : 2800 (part 1) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-incharge.
Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part 1). 150mm dia
Providing and placing in position filters of 40 mm diameter G.l, pipe with brass strainer of approved quality.
Providing and fixing G.l. Union in G.l. pipe including cutting and threading the pipe and making long screws etc. complete (New work) 40mm nominal bore
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having therma! stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction ot Engineer in Charge. 20 mm nominal dia Pipes,
25mm nominal dia Pipes,
40 mm nominal dia Pipes
Providing and fixing gun metal non- return valve of approved quality (screwed end) 40 mm nominal bore, Vertical
MOTOR PUMP SET
Supplying including installation, connection as, approved by the Deptt., testing and commissioning of SUBMERSIBLE PUMP SET 3 (Three Phase) with steel cable rope and submersible cable complete as directed and specified by the deptt. Three phase Submersible motor pump set (Texrno / Crompton Greaves/ Aquatic/ CRI/ V. Guar suitable for 100 mm bore well and above. 2 HP STAGE 6 to 30 with MCB controlled Submersible motor pump set control panel
WATER SUPPLY (PLUMBING)
Providing and fixing Chlorinaed Polyvinyl Chloride (CPVC) pipes, ,having thermal stablililty for hot & cold Wdtet supply Including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. Internal work- Exposed on work 15 mm nominal dia Pipes
20 mm nominal dia Pipes
25 mm nominal dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including ali CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm nominal dia Pipes
20 mm nominal dia Pipes
25 mm nominal dia Pipes
Providing and fixing chlornated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold Wdtet supply Including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 15 mm nominal dia Pipes
20 mm nominal dia Pipes
25 mm nominal dia Pipes
BRASS FITTINGS
Providing and fixing brass bib cock of approved quality : 15 mm nominal bore
20 mm nominal bore
Providing and fixing brass stop cock of approved quality 15 mm nominal bore
20 mm nominal bore
Providing and fixing brass ferrule with C.I. mouth cover including boring and tapping the main : 15 mm nominal bore
20 mm nominal bore
Providing and fixing C.P. brass long body bib cock of approved quality onforming to IS standards and eighing not less than 690 gms.
Providing and fixing required Stainless teel Fitting of press fit design of rade 316L as per IS 6911:2017 and onforming to ENI-10312 standards ith V-profile and with O-ring sealing asket of EPDM material of required ia as per direction of Engineer-inharge. For 15 mm outer dia pipe
For 22 mm outer dia pipe
For 28 mm outer dia pipe
Providing and fixing required Stainless teel Fitting of press fit design of rade 3161 as per IS 6911:2017 and onforming to EN-10312 standards ith V-profile and with O-ring sealing asket of EPDM material of required ia as per dirction of Engineer-in-charge. Reducer For 22mm x 15 mm outer dia pipe each
For 28 mm x 22 mm outer dia pipe
Providing and fixing required Stainless steel Fitting of press fit design of grade 3161 as per IS 6911:2017 and conforming to EN-10312 standards ith V-profile and with O-ring sealing asket of EPDM måterial of required ia as per direction of Engineer-in-charge ELBOW 900 For 15 mm outer dia pipe each
For 22 mm outer dia pipe each
Providing and fixing required Stainless teel Fitting of press fit design of ade 316L as per IS 6911:2017 and onforming to EN-10312 standards ith V-profile and with O-ring sealing Sket of EPDM material of required ia as per direction of Engineer-in-charge. Equal TEE Forr 15 mm outer dia pipe
For 22 mm outer dia pipe
Prooviding and placing on terrace (at all or levels) polyethylene water orage tank, IS : 12701 marked, with ver and suitable locking rangement and making necessary les for inlet, outlet and overflow pes but without fittings and the base pport for tank.
SANITARY
Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 ntre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete.
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings.
Providing and fixing Stainless Stee! A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required Kitchen sink with drain board 510x1040 mm bowl depth 225 mm
Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge.
Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe 32 mm dia
Providing and fixing 100 mm sand cast Iron rating for gully trap.
Providing and fixing mirror of superior glass (of pproved quality) and of required shape and size ith plastic moulded frame of approved make nd shade with 6 mm thick hard board backing oval shape 450x350 mm (outer dimensions)
Providing and fixing soil, waste and vent pipes 100 mm dia sand cast iron S&S pipe as per IS: 1729
Providing and filling the joints with spun yarn, cement slurry and cement mortar 1:2 ( ± cement 2 fine sand) in S.C.I./ C.I. Pipes 100mm dia pipe
Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. For 100mm dia pipe
Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 100mm diameter pipe Sand cast iron S&S as per IS - 3989
Painting sand cast iron/ centrifugally cast (spun) iron soil, waste vent pipes and fittings with two coats of synthetic enamel paint of any colour such as chocolate grey, or buff etc. over a coat of primer (of approved quality) for new work 100mm diameter
Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. Waste coupling 31 mm dia of 79 mm length and 52mm breadth weighing not less than 45 gms
Providing and fixing PTMT towel rail complete Mith brackets fixed to wooden cleats with CP brass screws with concealed fittingsIrrangement of approved quality and colour. 600 mm long towel rail with total length of 645 nm, width 78 mm and effective height of 88 mm, weighing not less than 1 0 gms.
ELECTRICAL WORKS WIRING IN STEEL AND PVC CONDUIT
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. GROUP-C
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 75 mm X 75 mm X 60 mm deep
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch
15/16 A switch
3 pin 5/6 A socket outlet
6 pin 15/16 A socket outlet
Supplying and fixing following size/ modules, Gl box along with modular base & cover plate for modular switches in recess etc. as required. l or 2 Module (75mmX75mm)
6 Module (200mmX75mrn)
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 1 or 2 Module
6 Module
Wiring for group controlled call (looped) bell point light (withoutpoint/fanfan point/ independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1,5 sq. mm FRLS PVC insulated copper conductor single core cable etc, as required, GROUP-C
MCCB, MCB & DB'S
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. 32 ATP&N
Jaquar Alexa 20L Storage Water Geyser.Remote InclÜded.Mount Type Horizontal.Capacity 20 L. Temparature range 25-75 dgree C. Code : AXP-WHTHO20.
Voltas 1.5 ton Adjustable 5 Star Copper 185V zzyspfit AC (Red/White)
Faber HOOD FEEL 3D PLUS MAX T2S2 BK TC 60 Kitchen Hood with 4 Way Suction Technology (MAX), Touch Control
Sri Ajay Nandi
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .