Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹27.1 LAccepted-AOC | 1 | Accepted-AOC L1 | |
| 2 | 2₹28.4 L+₹1.4 L (5.13%)Rejected-AOC | 2 | Rejected-AOC L2 |
Tender Value
₹32.7 L
EMD Value
₹50,000
Closing Date
16 Oct 2020, 5:00 pmClosed
CHIEF ENGINEER, KSCADC
CHIEF ENGINEER KSCADC 1st Floor, Chalachithra Kalabhavan Building, Vazhuthacaud, Jagathy P.O. Thiruvananthapuram Pin-695014
Basic Infrastructure Facilities and Human Development of Fisher folk (Rehabilitation) 2018-19 Karode, Thiruvananthapuram-Electrification of Phase 1 (16 Flats) and Phase 3 (48 Flats)
2020_SCADC_390426_1
ET-81/2020-21
Open Tender
Electrical Works
Item Rate
90 days
Karode
Please refer Tender documents.
6 documents required · 6 mandatory
₹2,975
online
₹50,000
6 Jan 2021
8 Oct 2020
20 Oct 2020
8 Oct 2020
16 Oct 2020
8 Oct 2020
Amount
Electrification to the Dwelling toLandless Fishermen at Karode. Phase 3 - 48 flats and phase 1 - 16 Flats
1.10.1 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group A
1.17.3 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1.17.12 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
1.39 : Providing and fixing plain 16/0.20mm (0.50sqmm) twin flat flexible, FRLS PVC insulated, copper cable, in PVC sleeve of suitable size on the floor / wall, or side of the table / door etc. as required.
od46748/2020_2021 : supplying and providing 32/0.20 mm (1.0 sqmm) twin circular, FRLS PVC sheathed, workshop flexible copper cable and giving all connections.
1.17.21 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.21.3 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm
od46749/2020_2021 : Supply and fixing of Angle holder or pendent type with 9w LED lamp.Including Lamp Shade.<br>
1.24.1 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
1.24.4 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
1.24.3 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
1.24.5 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
1.27.3 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.4 Module (125mmX75mm)
od46750/2020_2021 : Installation of LED type Tube light on wall/ceiling with necessary clamps supplied with the tube light and giving connection with the code wire.
1.38 : Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required.
1.50.1 : Installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required.Upto 450 mm sweep
2.3.2 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator8 way, Double door
2.12.1 : Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.14.2 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
5.4 : Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, andproviding masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
od46751/2020_2021 : Supply and laying bare copper conductor of 10 SWG size along with cables and crimping with required copper earth socket wherever necessary. <br>
5.14 : Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
od46752/2020_2021 : Supply, installation, testing and commisioning of following sweep ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated, copper condutor, single core cable etc. as required. (a) 1200 mm sweep ceiling fan white shade with stepped type electronic fan regulator (Usha (Striker)/,Crompton(High breeze)/ Havells (Velocity))<br>
od46753/2020_2021 : Supply of 300/305 mm sweep Light Duty Exhaust fan in metal frame working on 230 V A/C
od46754/2020_2021 : Supply of 225 mm sweep Light Duty Exhaust fan in metal frame working on 230 V A/C for site.
od46755/2020_2021 : Supply of 1200mm box type, 20W, tube light,of reputed company make like crompton,philips,wipro,etc.delivering cool day light with all accessories for site.
od46756/2020_2021 : Supply and installation of 32A HRC type fuse unit with base in the existing single phase meter box and giving all connections
od46757/2020_2021 : Supply and fixing suitable size HRC type fuse catridge ranging from 20A to 50A in the existing SFU and giving all connections.
od46758/2020_2021 : Supply and fixing 32A neutral link and giving all necesary connections
od46759/2020_2021 : supply and fixing 40A DP isolator in suitable metal box and fitting it inside the single phase meter board chamber and giving all connections
od46760/2020_2021 : Supply and installation of standard company make single phase energy meter chamber lockable type having sufficient gauge (16 gauge or equivalent) with all facilities for connecting the Energy meter supplied by the KSEB,necesary number of cut outs,32A SPN isolator etc.complete.
od46761/2020_2021 : Supply and fixing Bulk-head light fittings of reputed company make, with clear/froasted glass cover, pvc base suitable for 9 watt LED bulb,including bulb, and giving all connection with suitable three core wire etc. complete.
MICRON ELEC-TECH
Bidder Name
S K Electrics and Infrastructures
MICRON ELEC-TECH
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_555354.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .