| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.0 LAccepted-AOC G 16 JAY COMPLEX BELOW UMA CO OP BANK NIZAMPURA VADODARA 390 002 | VADODARA | VADODARA | GUJARAT | 390002 | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹49.2 L+₹3.8 L (8.25%)Rejected-Finance 4 A RUKSHMANI PARK SOCIETY OPP SAMA WATER TANK NEW SAMA ROAD VADODARA 390 008 | VADODARA | VADODARA | GUJARAT | 390008 | L2 | Rejected-Finance BEING L2 |
Tender Value
₹48.5 L
EMD Value
₹97,000
Closing Date
21 Dec 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF BARODA
GE AF BARODA PO DARJIPURA BARODA 390022
PROVISION OF CERTAIN SANCTIONED WORKS UNDER AGE B/R-I MAKARPURA AT AF STN BARODA
2022_MES_564753_1
8731/E8
Open Tender
Civil Works
Item Rate
270 days
GE AF BARODA
AS PER TENDER DOCUMENTS AND NIT
3 documents required · 3 mandatory
₹500
GE AF BARODA
₹97,000
Yes
23 Jan 2023
23 Nov 2022
23 Dec 2022
23 Nov 2022
21 Dec 2022
8 Dec 2022
24 Nov 2022 - 1 Dec 2022
Amount
M&L for PCC 1:3:6 type C2 as in foundation, filling and mass concrete complete all as specified and directed
S&F Rolled mild steel Fe 410-W (Gde E-250 quality - A) in Compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, etc fixed with necessary nuts, bolts, etc as in beam section complete all as specified and directed
S&F structural steel work as roof trusses (framed) trussed, purlins, crane gantries, rails and fastenings and heavy brackets framing (Beam, tee, angle, channel, gusset plate or flat section ) incl distance pieces, cleats etc conforming to grade Fe 410-0 or 310-0 complete all as specified and directed
S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed
M&L for preparation of new or previously untreated surfaces of any description, not otherwise described, over 10 cm in width or girth and applying two coat of synthetic enamel paint over and includig one coat of red oxide primer on new steel surfaces complete all as specified and directed
M&L for Cutting out wall/beam to V-section in existing roofs/beam or terracing, cleaning out, wetting, grouting with PCC and sand slurry 1:3 complete all as specified and directed
S&F for Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed
Excavating in post holes ( or similar holes ) each n.exc 0.5 cum getting out,returning filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding, 25 cm watering and removing surplus soil to a distance n.exc 50 m and making good surface in hard/dence soil complete all as specified and directed
Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed
M&L for prepration on the existing surfaces on wall/concrete surfaces throughly, washing rubbing down in the water, cleaning upto the entire satisfaction of the Engineer-in-Charge and apply one coat of cement base paint camouflage pattern including necessary form work upto 4th floor colour as approved by GE complete all as specified and directed
M&L for complete removal of existing treatment on wall/ceiling surfaces by scraping down and washing with water to the satisfaction of Engineer-in-Charge and applying two coats of Oil Bound Emulshion distemper over and including applying Birla white wall care putty (as approved by GE) and to be applied only by the authorised applicater of manufacturers (as approved by GE) including cleaning window glasses, joinery, electric fittings, wiring etc of drops and splashes and cleaning premises clean and tidy complete all as specified and directed
M&L for hard core with broken stone of gauge n.exc 63mm deposited spread and levelled in layers n.exc 15 cm thick complete all a specified and directed
M&L Plain cement concrete type D-2 1:4:8 (using 40mm graded crushed stone aggregate) as in 100mm thick flooring finished surfaces even and rough to receive the flooring etc without using extra cement, complete all as specified and as directed
M&L Plain cement concrete type B-2 1:2:4 (using 40mm graded crushed stone aggregate) as in 100mm thick flooring finished surfaces even and fair without using extra cement, complete all as specified and as directed
M&L for rendering in two layers (i.e) CM 1:6, 10mm thick as first layers and CM 1:4, 5mm thick as 2nd layer on fair face of brick or on concrete surfaces finished even and smooth without using extra cement complete all as specified and directed
M&L for preparation of newly plastered or unplastered surfaces of walls and applying two coats of cement base paint camouflage pattern over a priming coat on walls upto 4th floor including cleaning window glasses, joinery, electric fittings, wiring etc of drops and splashes and cleaning premises clean and tidy complete all as specified and directed. (Colour/shade as directed by GE).
M&L for preparation of newly plastered or unplastered surfaces of walls and applying two coats of cement base paint over alkali resistant priming coat on walls upto 4th floor including cleaning window glasses, joinery, electric fittings, wiring etc of drops and splashes and cleaning premises clean and tidy complete all as specified and directed. (Colour/shade as directed by GE).
S&F mild steel pipe, beam section etc fixed with base plates, necessary nuts, bolts, plate etc as in posts complete all as specified and directed
M&L for taking down exesting water proofing treatment (WPT) of any description from roof surfaces incl desmantling of existing PCC/plaster surfaces and roughening of concrete surfaces cleaning and wahsing down the surfaces with water and removing rubbish to out side MD land complete all as specified and directed. Note :- Felts and cement plaster/tiles etc shall be measured as one layer only.
M&L for 15 mm thick screed bed or bedding layer in CM 1:4 over roof surfaces without using extra cement for screed bed with water proofing compound @3% by wt of cement finished even and smooth (without using exra cement) complete all as specified and directed. Note : WPC will be measured and paid separatly
M&L for applying cold bituminous primer @ 0.30 ltr/Sqm confirming to IS-3384 and laying APP polymer modified fiber glass reinforced membrane 3mm thick weight not less than 3.5kg/sqm (modified bituminous water proofing membrane ) with plain finish with polystere base reinforcement, sealing all over with lap of 75mm in length side and 100mm on width side of membrane by torching the same and including applying a coat of bituminous aluminium paint @ 100 gms/sqm all as per manufacturer instructions complete all as specified and directed .
Note:- (a) Rate quoted deemed to be inclusive of cleaning of surface to be treated properly to receve the primer and all as directed by the Engr-in-Charge. (b) Necessary guarantee certificate shall be given by contractor for 10 years from the date of completion of work. (c) APP membrane treatment shall be done firstly at corners and junction of parapet wall 30cm on verticle position and 30cm on horizontal position shall be done with proper attention and work carried out by authorised applicator only.Main portion of roof treatment shall be commenced only on completion of corners/ edges/ junctions. (d) APP membrane shall be taken upto outside of the parapet wall to an extent of 150mm minimum. (e) Ensure while laying the treatment no bulging on surface/voids shall be found and proper care/attention be given for the treatment. (f) If any work executed at site without any authorised applicator, the same shall be rejected and no payment shall be made. (g) Codntractor shall produce the certificate from the manufacture for the authorised applicator before commencement of work.
M&L for cement conrete type B-0, 1:2:4 (using 12.5mm stone aggregate) (in roof slabs) laid to stop 1:30 in padding for WPT over roof slab complete all as spd and as directed.
Disconnecting existing water tanks (PC/RCC) exc 500 ltr & n.exc 1000 ltr capacity, setting aside (or lowring if required ) for repairs, cleaning etc and hoisting if required , reconnected including cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc.complete all as specified and directed
Demolition of brickwork or stone/boulder masonry built in cement mortar incl all quoins, arches pillars etc but excluding ashlar facings complete all as specified and directed
S&F Rotational moulded polyethylene water storage tanks 1000 ltr capacity (cylindrical vertical with closed top) hoisted and fixed in position including taking down the existing one all as specified in SSR Part I complete all as specified and directed
M&L Brickwork with subclass 'B' bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 all as specified and directed
Taking up or down 20mm bore steel tubing and connections, including cleaning for re-fixing or removal to store all as specified and directed
Taking up or down 25mm bore steel tubing and connections, including cleaning for re-fixing or removal to store all as specified and directed
S&F 20mm bore Tubes,'Medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors all as specified and directed
S&F 25mm bore Tubes,'Medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors all as specified and directed
S&F (in repair) 25mm size Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 455gms) and fixed complete all as specified and directed
S&F (in repair) 25 mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed
S&F 25mm GI Nipple suitable for HDPE water tank. (Minimum weight 25mm- 65gms) complete all as specified and directed
Supply only waterproofing compound complete all as specified and as directed
Taking down cement plastered on brick or stone walls etc including raking out joint, hacking for key, scrubbing down with water etc, complete all as specified and as directed
M&L for Framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work including pintle hinges, stops, hand made sliding bolts etc incl ornamental and intricate design con- forming to Fe.290.Gde-E-165 Complete all as specified and as directed
S&F mild steel Welded steel wire fabric (weight per Sqm not exc 4 Kg) complete fixed to wood or steel members complete all as specified and directed
S&F 100mm Butt hinges, medium weight, cold rolled mild steel, and fixed complete all as specified and directed
M&L for complete removal of existing treatment by scraping down completely on brick walls/stone walls/concrete surfaces plastered or unplastered thoroughly, rubbing down, washing with water to the entire satisfaction of Engineer-in-Charge and applying two coats of Cement Base Paint camouflage pattern (Colour or shade as approved by GE) over alkali resistant priming coat as per manufacturers instruction complete including cleaning window glasses, joinery, electric fittings, wiring etc of drops and splashes and cleaning premise clean and tidy complete all as specified and directed
M&L for prepration on the existing surfaces of walls/concrete surfaces as directed and applying one coat of oil bound emulsion including wall care putty on old decorated surface including scraping ,rubbing down with water cleaning the surface up to the entire satisfaction of the complete all as specified and directed
M&L, Preparation of old plastered surfaces of ceiling and applying two coat of white wash complete all as specified and as directed
S&F 0.56mm thick Plain, Aluminium sheeting, Alloy 31000 H4 in ridges, hips, valley gutter, drip and straight flashing (length and girth as fixed) complete all as specified and directed
S&F (in repair) 18/19mm thick Prelaminated particle board, exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work complete all as specified and directed
Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed
Taking down Chowkhats or frames with shutters (without taking off shutters from the frames)not exc. 1.5 sq. m each complete all as specified and directed
Taking down Chowkhats or frames with shutters (without taking off shutters from the frames) exc. 1.5 sq. m and n.exc 4.00 sqm each complete all as specified and directed
Taking down Shutters of any description n. exc 1 sqm each complete all as specified and directed
Taking down Shutters of any description exc 1 sq. m but n.exc 2 eqm complete all as specified and directed
Dismantling of timber scantling 40 Sqcm and over in section in any position as in unframed work complete all as specified and directed
M&L for cement conrete type B-0, 1:2:4 (using 12.5mm stone aggregate) (in roof slabs) of any thickness to level the roof surfaces finished even and smooth with using extra cement complete all as specified and as directed.
Dismantling boarding, any description, fixed in any position with nails complete all as specified and directed
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and directed
Supply and fix false ceiling work of aluminium anodised snap grid frame work, size of grid 605 X 605mm , 6mm thick non asbestos fibre cement building boards fixed or laid / inserted to timber / GI / Aluminium frame work with screws, including hangers 6mm dia, G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40 X 3mm size 60mm long and applying two coats of two coats of white wash incl preparation of new surfaces on ceilings complete all as specified and directed
M&L preparation of newly plastered or unplastered wall surfaces and applying two coats of oil bound emulsion distemper (as approved by GE) including applying Birla white putty as per manufacturers's specifications. applied only by the authorised applicator of manufacturer(as approved by GE) Complete all as specified and directed
M&L for complete removal of existing treatment by scraping down completely on brick/stone walls/concrete surfaces thoroughly, rubbing down washing with water to the entire satisfaction of Engineer-in-Charge and applying two coats of exterior ACRYLIC Emulshion paint (Colour or shade as approved by GE) over and including a coat of primer as per manufacturers instruction complete including cleaning window glasses, joinery, electric fittings, wiring etc of drops and splashes and cleaning premise clean and tidy complete all as specified and directed
M&L for complete removal of existing treatment on wall surfaces by scraping down and washing with water to the satisfaction of Engineer-in-Charge and applying two coats of Oil Bound Emulshion distemper over and including applying Birla white putty (as approved by GE) and to be applied only by the authorised applicater of manufacturers (as approved by GE) including cleaning window glasses, joinery, electric fittings, wiring etc of drops and splashes and cleaning premises clean and tidy complete all as specified and as directed
S&F 4mm thick Sheet glass, ordinary Quality and glazing with oil putty/rubber gaskit wooden/aluminium section beeds in square exc 0.5 sq. m in each pane complete all as specified and directed
Resecuring or easing & adjusting without taking down shutters of any description n exc 1 sqm each complete all as specified and directed
Resecuring or easing & adjusting without taking down shutters of any description exc 1 sqm and n exc 2 sqm each complete all as specified and directed
S&F (in repair) Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples fixed with aluminium secton complete all as specified
Demolition of Stone slabs and tiles of any description or thickness Laid bedded and pointed in any mortar in floors, aprons etc complete all as specified and directed
M&L Machine cut kota stone slab flooring 20-25mm thick over and including 20mm cement screed base in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of theslab including rubbing and polishing complete all as specified and directed
M&L Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over and including 15mm thick cement screed and jointed with grey cement slurry mixed with pigment to match the shade of theslab including rubbing and polishing complete all as specified and directed
S&F 18/19mm thick Prelaminated particle board, exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work complete all as specified and directed
S&F 12mm thick Plywood, grade BWR, type BB, fixed with screws to timber frame work such as door shutters complete all as specified and directed
M&L for preparation of newly plastered or unplastered wall and applying two coats of exterior ACRYLIC Emulshion paint (Colour or shade as approved by GE) over and including a coat of primer as per manufacturers instruction complete including cleaning window glasses, joinery, electric fittings, wiring etc of drops and splashes and cleaning premise clean and tidy complete all as specified and directed
M&L Grinding and mirror polishing of old surface of kota stone and matching with existing or new surface complete all as specified
S & F second class hard wood plain solid straight chowkats and frames, worught framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed
S&F 30mm thick Flush shutters, solid core construction, with block board core and plywood face panels, and both faces covered with decorative face veneer with lipping/frame to match complete all as specified and directed
S&F 30mm thick 2nd class HW Glazed and skeleton shutters for windwos and ventilators, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (b); supplied and fitted to chowkats complete all as specified and directed
S&F 35mm thick 2nd class HW Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and directed
M&L for preparation of new wooden Surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed
M&L for preparation of old painted surfaces of wood and wood based material of any description over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed
S&F in repair 150mm Aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed
S&F 300mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed
S&F in repair 300mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed
S&F Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor (overall length of cover plate 140mm) complete all as specified and directed
S&F in repair Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor (overall length of cover plate 140mm) complete all as specified and directed
S&F 100mm size stainless steel butt hinges medium weight and fixed to chowkats with screws complete all as specified and directed
S&F 150mm size Extruded aluminium alloy handles, fabricated type, anodized complete all as specified and directed
Surface excavation n. exc 30 cm deep and averaging 15cm deep and getting out soft / loose soil complete all specified and directed
S & F 200mm Mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified and directed
S&F 150mm size Aluminium handles, cast type, anodized complete all as specified and directed
S&F 150 mm Aluminium anodised tower bolts of extruded section including screws complete all as specified and directed
S&F in repair 100mm size Extruded aluminium alloy handles, fabricated type, anodized complete all as specified and directed
M&L Pre-cast cement concrete block type C-1 1:3:6 (20mm graded aggregate) masonry with solid blocks, exc. 10 cm in width and setting in mortar 1:6 complete all as specified and directed
M&L rendering 10mm thick in CM (1:6) on fair faces of brick work or concrete surface ,finished surface even & smooth without using extra cement complete all as specified and directed
Gayatri Associates
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .