Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.7 CrAccepted-AOC MANATHA ENCLAVE 3RD FLOOR OLIMUGAL KAKKANAD P O KOCHI 682 030 KERALA | ERNAKULAM | KERALA | 682030 | ₹9.7 Cr | L1 | Accepted-AOC Being L1 |
| 2 | L2₹9.9 Cr+₹14 L (1.44%)Rejected-AOC BLDG NO 22 2079 COAST GUARD ROAD NEAR COAST GUARD FAMILY ACCOMMODATION MUNDAMVELI PO PALLURUTHY VII ERNAKULAM 682 507 | ERNAKULAM | ERNAKULAM | KERALA | 682507 | ₹9.9 Cr+₹14 L (1.44%) | L2 | Rejected-AOC Being L2 |
| 3 | L3₹10.4 Cr+₹68.5 L (7.04%)Rejected-AOC | ₹10.4 Cr+₹68.5 L (7.04%) | L3 | Rejected-AOC Being L3 |
| 4 | L4₹10.8 Cr+₹1.0 Cr (10.6%)Rejected-AOC NOT SPECIFIED | ₹10.8 Cr+₹1.0 Cr (10.6%) | L4 | Rejected-AOC Being L4 |
| 5 | L5₹10.9 Cr+₹1.2 Cr (12.1%)Rejected-AOC 184 MAIN STREET NASIRABAD AJMER RAJASTHAN 305601 | ₹10.9 Cr+₹1.2 Cr (12.1%) | L5 | Rejected-AOC Being L5 |
Tender Value
₹11.5 Cr
EMD Value
₹9 L
Closing Date
12 May 2023, 6:00 pmClosed
CE NW Kochi
CE(NW) Kochi Naval base P O Kochi- 682004
COMPLETION OF INCOMPLETE WORKS FOR CONSTRUCTION OF WAREHOUSE AT MO(K) AT NAVAL BASE KOCHI
2023_MES_590235_1
890773A
Open Tender
Civil Works
Lump-sum
540 days
Kochi
Please refer Tender documents.
8 documents required · 8 mandatory
₹3,000
Yes
₹9 L
Yes
22 May 2023
20 Apr 2023
15 May 2023
21 Apr 2023
12 May 2023
5 May 2023
21 Apr 2023 - 3 May 2023
Amount
LIST OF WORKS
Schedule A Part I ( to Part XII)
Total amount of Sch 'A' part-I (Buildings & Structures)
Total amount of Sch 'A' part-II ( Excavation, Earth work and Site development)
Total amount of Sch 'A' part-III (Internal water supply)
Total amount of Sch 'A' part-IV (Road/Culvert/Hardstanding)
Total amount of Sch 'A' part-V(Area Drainage)
Total amount of Sch 'A' part-VI ( Sewage Disposal)
Total amount of Sch 'A' part- VII (External Water Supply)
Total amount of Sch 'A' part- VIII(External Electric Supply)
Total amount of Sch 'A' part- IX (Fire fighting)
Total amount of Sch 'A' part- X (Lightning Protection)
Total amount of Sch Á' Part XI(Aviation Obstruction Light)
SCH. 'A' PART - XII. (MISCELLANEOUS)
Note :- This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
INTERNAL WATER SUPPLY:- Angular stop cock, chromium plated, cast copper alloy, screwed down, screwed for iron pipe 15 mm dia bore. Make Jaquar Code No CON-059KNor equivalentmodel in other make as listed in CA, all as specified and as directed.
Bib tap, cast copper alloy, chromium plated, fancy type of size 15mm long body all as specified and as directed . Make: Jaguar Cat No ORP-10037PM or equvilent available in other makes as listed in CA.
Pillar taps fancy type 15 mm Dia cast copper alloy with capstan heads, chromium plated ,screwed down high pressure, with long screwed shanks and fly-nuts, screwed for iron pipe and fixed.for WHB all as specified and as directed. Make: Jaguar Cat No ORP-10001PM or equvilent available in other makes as listed in CA.
Health Faucet with 1 Mtr flexible tube in chrome finish16 mm dia (outer), low density ploythene, suitable for cold water application complete with union and teflone washers and holder to suit 15 mm angle cocks all as specified and as directed. (Make : Jaguar cat part No ALD-IVY-585 or equivalent model in other makes as listed in CA.).
INTERNAL ELECTRIC SUPPLY: - Point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), with multi-stranded copper conductor 1.5 Sqmm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLS cable 1100 volts grade, ISI-694 marked including heavy duty PVC concealed conduit and conduit accessories concealed in wall/roof/floor etc, ISI marked including modular GI flush box of suitable size with inner and outer white plastic plate (Same make of approved switch and socket) including PVC insulated multi-stranded copper conductor 1.5 Sqmm nominal cross sectional area single core F.R.L.S. cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed at site for the following:- (NOTE: Switch and socket to be measured and paid for separately):-
a) One light/Ceiling Fan/exhaust fan point controlled by one 5/6 amps one way switch, all as specified and as directed.
(b) One Socket outlet, three/five pin, 5 Amp, independent controlled by one 5/6 amps one way switch or switch/socket combination 5 amps, 5 pin, all as specified and as directed.
(c) One light point controlled by 2 Nos, 2 Way switches 5/6 Amps, all as specified and as directed.
Point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), with multi-stranded copper conductor 2.5 Sqmm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLS cable 1100 volts grade, ISI-694 marked including heavy duty, PVC concealed conduit and conduit accessories concealed in wall/roof/floor etc, ISI marked including modular GI flush box of suitable size with inner and outer white plastic plate (Same make of approved switch and socket) , including PVC insulated multi-stranded copper conductor 2.5 Sqmm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed at site for the one 3/5 pin 15/16 amps socket outlet independent, all as spec ified and as directed. (NOTE:- Switch and socket to be measured and paid for separately)
Modular switch 1 way 6 A, 1 module 230 Volts,50Hz, ISI marked with valid CML No, all as spec ified and as directed.
Modular switch 1 way 16 A, 1 module 230 Volts,50Hz, ISI marked with valid CML No, all as spec ified and as directed.
Socket, 6A-2/3 pin combined 2 module 230 Volts,50Hz, ISI marked with valid CML No, all as spec ified and as directed.
Socket, 16A-2/3 pin combined 2 module 230 Volts,50Hz, ISI marked with valid CML No, all as spec ified and as directed.
Modular switch 2 way 5 A, module 230 Volts,50Hz, ISI marked with valid CML No, all as spec ified and as directed.
Ceiling rose, three terminals,230 (ISI marked) surface bakelite suitable for batten fitting complete all as specified and as directed.
Ceiling fan 1200mm sweep copper wound having minimum 5 star rating , including fixing of down rod and connecting up complete with and including three core flexible PVC insulated multi stranded copper conductor cable of size 0.5 Sqmm from ceiling rose/ connector to fan, all as specified and as directed. .(Make :CG/USHA/HAVELLS)
Fan step regulator, 120W-2 module 230 Volts,50Hz, ISI marked with valid CML No, all as specified and as directed.
Exhaust fan 250 mm sweep 230 Volts AC 50 Hz PVC body with copper wound having minimum 5 star rating and including complete all as specified and directed.
Exhaust fan 450 mm sweep 230 Volts AC 50 Hz PVC body with copper wound having minimum 5 star rating and including complete all as specified and directed.
LED Tube light 1X20 Watt 6000K Havells Cat Part No LHEWEBP7IN1W/020 or equivalent make of CG/Philips, all as specified and as directed.
LED 34 Watt light fitting aesthetically designed 4X1 LED flat panel for surface mounting, soft light and glare free symmetrically illumination of make Havells Cat Part No LHEWEIP7IK1W034 or equivalent make of CG/Philips, all as specified and as directed.
Sleek LED mirror light 1X10 Watt (Make : CG Cat Part No LCL-10-CDL or equivalent make of Havells/Philips), all as specified and as directed.
LED bulb 5 watts suitable for angle holder/batten holder of make CG or equivalent of Havells/Bajaj, all as spec ified and as directed.
Street light fitting pressure die cast aluminium housing heat resistance toughtned glass having IP 66 protection of 25 Watt complete including fixing with GI Bracket made of 43mm dia GI Pipe including fixing clamps etc complete. (Make Havells 25W LED IP66 security light Model No.LHETAXU7PA6J025 or equivalent make of CG/Philips).
DB 6 way,TPN, double door IP 43 protection, shrouded Neutral bar, earth termination complete all as specified and directed by Engr-in-Charge.Make Indo Asian Cat No 811843 or equivelant in Havells/Standard/ Legrand.(Out going MCB shall be measured and paid seperately under relevant item)
Vertical DB 4 way,TPN, double door IP 43 protection, shrouded Neutral bar, earth termination complete all as specified and directed by Engr-in-Charge.Make: Indo Asian Cat No 811841 or equivelant in Havells/Standard/ Legrand.(Out going MCB shall be measured and paid seperately under relevant item), all as specified and as directed.
MCB DB SPN 12 way double door 240 Volts without bus bar, all as spec ified and as directed.
MCB DB SPN 8 way double door 240 Volts without bus bar all as specified and as directed.
MCB DB SPN 4 way double door 240 Volts without bus bar all as spe ified and as directed.
MCB TPN 40 Amps "C" Curve, all as specified and as directed.
MCB SPN 6-32 Amps "C" Curve, all as spec ified and as directed.
MCB S P 6-32 Amps "C" curve, all as specified and as directed.
Earthing complete with galvanised steel earth plate electrode size 600x600x6.0mm thick burried directly in ground vertically in a pit of depth not less than 2.25 mtr below normal ground level with top edge of the earth plate not less than 1.5 mtr below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including galvanised earth lead 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel and earth wire protected by GI protection pipe light grade 15mm dia connected to main earth wire on pole or control board and GI pipe light grade 20mm bore for watering, funnel with wire mesh. PCC chamber pit in PCC 1:3:6 type C-1, 40 mm thick precast RCC M-25 (design mix) cover reinforced with 8 mm dia TMT bars @ 10 cm C/C on both sides and handle, excavation and earth work in any type of soil and removal upto 50 m complete all as specified and shown in electric plate No.03 of SSR Part-I(2009), connecting to earthing test point all as specified and directed including testing on completion.
Wiring with 4 Sqmm two single core(for phases and neutral) using multistranded copper conductor PVC (F.R) insulated unsheathed with and incl 4 Sqmm insulated unsheathed PVC insulated multistranderd copper conductor as earth continuity conductor connected to common earth dolly drawn in PVC conduit ISI marked with accessories (this item operates for sub main wiring, 144 Nos geyser point wiring and for 96 AC point wiring) (Note: 03 runs of 4 sqmm and one run of PVC concealed conduit shall be measured as one run only), all as specified and as directed.
Wiring with 2.5Sqmm two single core(for phases and neutral) using multistranded copper conductor PVC (F.R) insulated unsheathed with and incl 2.5 Ssqmm insulated unsheathed PVC insulated multistranderd copper conductor as earth continuity conductor connected to common earth dolly drawn in PVC conduit ISI marked with accessories (Note: 03 runs of 2.5 sqmm and one run of PVC concealed conduit shall be measured as one run only), all as specified and as directed.
EXTERNAL ELECTRIC SUPPLY:- 11 KV, 630A, 20 KA, Motor operated, Compact, outdoor, both side extensible, non drawout type, +V+ (01 No. )fixed type motor operated Vaccum Circuit Breaker (VL), outgoing Safeplus compact gas insulated Ring main unit. All live parts enclosed in a robotically welded stainless steel tank of IP 67 class of protection including coupling, accessories all as specified and as directed.
Transformer step down, indoor type, copper wound, oil cooled complete with standard fittings HT 11/0.433 KV, 3 phase, 4 wire with off load tappings on HT side to vary secondary voltage within limit +/- 5% in step of +/- 2.5%. ONAN all as per IS :1180 of capacity 250 KVA duly initial oil filled up to normal level with following accessories and functions alongwith foundation as per the recommendations of the manufacturer. (i) No load loss as per standard (subject to IS tolerance) (ii) Full load loss as per standard (subject to IS tolerance) (iii)Impedance shall be 4.75% (subject to IS tolerance) (iv) Vector group Dyn 11 (v) Silica gel breather (vi) conservator with plain oil gauge and oil drain plug (vii) Top filter valve (viii) Bottom filter cum drain valve (ix) shut off valve between buchholz relay and conservator (x) Off circult tap changer (xi) Rating and diagram plate (xii) Earthing terminals (xiii) Thermometer pockets (ivx) Lifting lugs (xv) Air relief plug (xvi) Jacking pads (xvi) Bi-directional rollers (xviii) Explosion vent with single diapharam (xix) Detachable radiators (xx) Inspection cover (xxi) Danger notice board (xxii) cable entry box. Note: (i) Contractor will shift the transformer including loading/unloading very carefully by using crane and truck to the site inside the Naval Base as per the direction of the Engr-in-Charge and the rate shall be included in the quoted rate.
(ii) Any damage found, while shifting the transformer shall be replaced by the contractor at his own risk, in this matter GE’s decision is final (iii) Foundation shall be made by the contractor for the transformer as per the recommendation of the manufacturer and the rate shall be included in the quoted rate (iv) Contractor shall make necessary arrangements of tools, labour etc and to carry out Pre-commissioning inspection as per IE Rule and as circulate by the Engineer-in-Charge (v) Contractor shall provide necessary cable glands, cable end socket, etc and the rate shall deemed to be included in the quoted rate.
Capacitor metalised poly propylene heavy duty (MPP-H) for 3 phase, 440V, 50 Hz System for permissible non-linear load 15% of 80 KVAR capacity all as directed.
XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable, heavy duty with stranded conductor, 11000 volts grade of size 3 core 185 sqmm all as directed.
Cable end termination indoor heat shrink type complete with jointing materials and accessories suitable forXLPE 11 KV grade armoured aluminium conductor of size 3 core 120 to 185 sqmm all as directed.
External Water Supply:-Monoblock pumpset of capacity 1 HP self priming complete with capacitor, necessary pipe line connections, foot valve, all accessories and foundation, etc. including necessary cables of suitable size and electric connections complete all as specificied and as directed.
Electric insulation mat of size 1mtr x 2 mtr x 19mm all as specified and as directed.
Cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured,electric cable, heavy duty, 1100 volt grade with stranded aluminium conductor of size 3.5 core 300 sqmm all as specified and as directed.
Cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured,electric cable, heavy duty, 1100 volt grade with stranded aluminium conductor of size 3.5 core 50 sqmm all as specified and as directed.
Cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured,electric cable, heavy duty, 1100 volt grade with stranded aluminium conductor of size 4 core 25 sqmm all as specified and as directed.
Cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured,electric cable, heavy duty, 1100 volt grade with stranded aluminium conductor of size 3.5 core 150 sqmm (for APFC Panel) all as specified and as directed.directed.
LT panel board outdoor type floor mounting, cubical type made out of 3 mm thick CRCA sheet factory fabricated CPRI certified and angle iron frame dust and vermin proof factory made with aluminium bus bar of capacity 500 Amps for 3 phase and neutral duly powder coated complete comprising of the following :- (a) MCCB FP 400 Amps 36 KA as incommer - 01 (b) MCCB FP 315 Amps 36 KA as outgoing - 01 (c) MCCB TP 160 Amp 35 KA as outgoing -01 (for APFC Panel) (d) Multifunction meter -01 (e) Phase indicator light Led type -01 set (RYB)
LT panel board indoor type floor mounting, cubical type made out of 2 mm thick CRCA sheet factory fabricated CPRI certified and angle iron frame dust and vermin proof factory made with aluminium bus bar of capacity 500 Amps for 3 phase and neutral including powder coated complete comprising of the following :- (i) MCCB 4P 400 Amps 36 KA as incomming - 01 No (ii) MCCB 4P 315 Amps 35 KA - 01Nos (for AMF Panel) (iii) MCB TPN 40AMP 415V - 04 Nos (03 Nos for each floor + 01 Spare) (iv) MCB SPN 20 Amps, 240 volts -01 Nos (Common area lighting) (v) Digital Multifunction meter with necessary CTs - 01 Set vi) Three phase indicator lamp Led type RYB - 01 Set
DG SET :-Silent Diesel Engine driven generating set with AMF Panel , 415 volts, 3 phase 4 wire, engine as per IS:10001/ 10002 and Alternator as per IS: 13364 complete with relay panel and switch gears for automatic starting on main failure, control panel having meter and sound proof canopy as per CPCB norms and foundation etc. of capacity 250 KVA, all as specified and as directed.
Indoor type panel board dust & vermin proof powder coated made out of 3 mm thick MS sheet factory fabricated, CPRI certified welded/bolted on angle iron or re-inforced frame with the following incoming and outgoing arrangements a) Aluminium bus bar set 500 Amps-01set b) MCCB 4 pole 315 Amp 35 KA -01No (incoming) c)MCCB TPN 200 Amps Amps 415 V -01 Nos d)MCCB TPN 63 Amps Amps 415 V -03 Nos e) MCB TPN 20A-01 f) Digital multifunction meter - 01 set g) Indication lamp LED -01 set of three
Cutting the existing the bituminious Road/Hard standing /RCC floor all as specified and as directed.
FIRE FIGHTING Fire hydrant valve made out of gunmetal single headed with flanged inlet and 63mm female instantaneous outlet with 80mm dia cast iron stand post including blank caps and chain with flanged riser duck foot bend, 1.5 m long short piece - 1No, bolts, nuts,washers and gasket for flanged joints including painting and testing complete all as directed.
DI pipe both ends flanged and drilled pipes including specials class K - 9 in any length laid in trenches of size 150 MM bore, all as specified and as directed.
MS flanged pipe heavy duty ISI marked with all fittings of size 100 mm dia with flanged ends fixed on walls/floors/roof ete including fixing with clamps on wall for the wet riser including painting with approved synthetic enamel paint , all as specified and as directed
MS flanged pipe heavy duty ISI marked with all fittings of size 150 mm dia with flanged ends fixed on walls/floors/roof ete including fixing with clamps on wall for the wet riser including painting with approved synthetic enamel paint all as directed
63 mm dia gun metal branch pipe with 12.5mm nozzle conforming to IS 903
Addressable electronic sounder cum strobe
Air cushion tank (air vessel) 200 mm dia 1200 mm height with dished top made out of 6 mm thick MS plate suitable for floor mounting including 1 No 20 mm dia wet riser including GI Tee of size 100x100x20 mm all as directed
Fire alarm control panel complying with BS EN 54 four loop panel with 99 detectors & 99 modules upto 200 detectors and modules per loop.
Addressable manual call point resettable type
Detector complying with and type certified toEN-45 Addressable type multisensor detector with smoke and heat combination with intelligent type using analog addressable sensors
Fire Alarm sounders / Sirens electronic type horizontal two stage continuous normal operation for at least 50 minutes with sound level 65 db to 120 db Measured at 1.5 m with sound output variation of + 5 db 500m range all as specified and directed
Analog Addressable type Active Loop Repeater (Loop power/external power) Fire terminal with inbuit turbo isolator, Backlit LCD Display 6x40 characters display,having Controls For Reset, Mute, Accept , Silence alarms and Self Test, with programmable free keys and Duly Approved by EN54/LPCB/VDS/FM all as specified and directed
Fire pump horizantal end suction, centrigal type CI casing and bronze impeller stainless steel shaft, suitable for delivering 2850 LPM, 70 meter head (01 for fire fighting pump and 01 for sprinkler pump) all as specified and directed
Diesel driven fire pump horizantal end suction, centrifugal type CI casing and bronze impeller stainless steel shaft, suitable for delivering 2850 LPM, 70 meter head Make : CG/Kirloskar all as specified and directed
Electric Driven Jockey pump delivering 180 LPM up to 70 meters head all as specified and directed
Cable UG XLPE insulated, screened, PVC bedded with galvanised steel strip or wire armoured, 1100 volts grade with stranded aluminium conductor of size 16 Sqmm 4 core all as specified and directed
Wall mounted LED emergency Exit signage luminaire light up using regular mains supply comes with a unique rechargeable Ni-Cd battery capable of emergency back up upto 05 hours (Cat No LSSR5W Make CG or equivalent to Bajaj/havells all as specified and directed
PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 1.5 Sqmm ,2 core, 1100 Volts grade all as specified and directed
LT motor control panel, floor mounting type fabricated from 2.0mm thick CRCA sheet, dust and vermin proof complete with aluminium bus bar 300Amp with following accessories :- (a) MCCB FP 200 Amps 35 KA as incomming - 01 No (b) MCCB TPN 100 Amps 25 KA - 02 (c ) MCB TPN 20A - 01 (d) MCB SPN 20 Amps - 01 Nos (e) Digital multifunction meter -01 (f) Star delta starter 3 Nos (g) Phase indicating lamps (LED) R,Y,B - 1 Set
Booster pumps for 440 V, 3 Phase, 50 HzConfirming to IS- 12469 :1988 With CI Casing bronze impeller and stainless steel shaft mounted on heavy duty bearings suitable for 440 volts, 3 phase, 50 Hz 30mhead, 450 LPM discharge incl all fittings complete. Make : Kirloskar/CG.
LT motor control panel floor mounting type fabricated from 3 mm thick CRCA sheet, dust and vermin proof complete with aluminium bus bar 300Amp and with following accessories :- (a) MCCB FP 63 Amps 25 KA as incomming - 01 No (b) MCB TP 32 Amps 25 KA - 02 (one for pump and one spare) (c ) MCB SPN 16-20A - 02 (d) Power contactor 3 pole AC MNX 9 1NO+1NC - 01 Set (e) Digital multifunction meter -01 (f) Star delta starter 2 Nos (g) Phase indicating lamps (LED) R,Y,B - 1 Set
Cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured, electric power cable (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 4 core 25 Sqmm including necessary cable lugs,nut bolts,Cable glands etc all as specified and as directd.
MCCB 63Amps 4 Pole 16KA with enclosure all as specified and as directd.
AIR CONDITIONING Design, supply, install, commissioning and testing of Central AC plant (capacity 20 TR (2x10 TR) appx], chilled water type complete with all equipments such as Chiller / condenssor unit, Chilled water/ condensor water pumps, AHUs etc and accessories such as pipe line, electrical control panel, ducting for supply/return air, grills, diffuser, dampers, humidifier, fire damper, control valves, cooling tower, PCC foundation, earthing for eqpts & LT panel board, cabling, rubber mats, insulation for chilled water line, accoustic insulation underduck insulation in AHU Rooms all as shown on drawing and as directed internal wiring between eqpts panel, cable from Main panel to AHUs, and painting, nominal capacity as required to achive design conditions as per user data sheet (enclosed at Appx 'A') and in rooms shown in bldg Drg (The rooms indicated in the Plan as A/C) in three season (summer, winter and monsoon wrt outside conditions at Kochi). The eqpt shall be Indian brand, energy efficient, environmental friendly, all as per latest technology and conforming to standard IS & safety code. NOTE: (i) Unit rate quoted by the contractor shall be deemed to included for all connected civil works, electrical works of floor drgs & other design details such as heat load calculation,capacity of plant, lay out plan of eqpts, & floor Drgs etc duly vetted
by Govt agency ie IIT/NIT for approval by accepting officer. Rate shall also deemed to be inclusive for providing all minor parts which are not included in brief specification below but required at site technically for Installation, commissioning, testing of entire plant to achive design condition & efficient performance, smooth functioning of the plant (ii) Contractor will submit capacity & type of chiller unit including AHUs for which rate quoted before acceptance of tender BRIEF DESCRIPTION OF ITEMS:- 1 (a) CHILLER PACKAGE UNITS Factory designed and pre-fabricated vapour compression refrigeration water cooled chiller package of Designed capacity of approved make comprising of semi hermetic compressor of scroll type either single compressor or multiple compressor with independent refrigerant circuit HFC 134a Refrigerant.
Squirel cage induction motor suitable for operation of 415 volt (+) (-) 10%, 3 phase 50 Hz water cooled condonser and flooded cooler with electronic expansion valve complete, factory assembled evaporator and refrigerant piping, factory assembled Refrigerant piping as per specification, gauge panel, drive package, microprocessor based control panel, associated wiring for all accessories to make the chiller package ready for commissioning and having features of auto operation, mini-run time equalization, auto restart after power failure, built in time delay, fault diagnostics etc complete with suitable capacity power contactors, motor starter duly pre-wired and inter connected for three units including initial charge of Refrigerant and compressor oil 2 Units (01 Nos working and one standby). NOTE (i) Efficiency of scroll chiller package shall comply with ECBC norms and manufacturer certificate indicating power consumption shall submit before placing the final order. 1(b) CONDONSER WATER CIRCULATION SYSTEM. Comprising the following :- (i) Monoblock, centrifugal pump (EEC Series) suitable capacity for chiller plant @ manufacturer designed discharge capacity for CONDONSER WATER PUMPS in cast iron body,
bronze impellar with mechanical seals. Induction motor shall be TEFC squirrel cage, working on 415 V 3 phase, MS fabricated base plate mounting channel frame, and fittings i.e. coupling guard and vibration pad 2 Nos (01 Nos working and 01 No as stanby). (ii) FRP induced draft cooling tower rectangular/cylindrical type, capacity suitable for chiller plant complete installed on PCC / brick staging with spray section, honey comb fill basin, fan, suitable capacity of induction TEFC Motor working on 415 V 3 Phase, intake, bird screen and other accessories (Tech Specification as per manufacturer) 2 Nos (1 No working + 1 No standby). (iii) PVC/HDPE make up water tank of capacity for 24 Hrs run installed on PCC/brick staging for make up water requirement including brass float valve with polyethylene ball, over flow and drain arrangement, incoming connection of GI pipe 25mm medium grade from tank to tapping point, air vent, overflow pipe line etc 1 (c) CHILLED WATER CIRCULATION SYSTEM. Comprising the following :- (i) Monoblock, centrifugal pump (EEC Series) of suitable capacity for chiller plant in cast iron body, bronze impellar with mechanical seals, induction motor shall be TEFC squirrel cage, working on 415 V 3 phase-2 Nos (01 No working and one No as standby).
(ii) HDPE/PVC Expansion tank of 500 ltrs capacity including pipe connections including insulation and necessary piping, control valves on inlets and washout, float valve etc – 01 Job 1 (d) CHILLED / HOT WATER PIPING Chilled water piping with MS class `C’ class ERW pipe of suitable diameter including all weldable fittings, fixing arranements and Insulation complete for entire system. 1 (e) AIR TREATMENT SYSTEM -1 Nos Double skin construction air handling units floor mounted type suitable for chilled water system made out of extruded aluminium structural frame / aluminium corners and intermediate connecting pieces and panes of 0.6 mm galvanized steel sheet on both sides with 25mm thick pressure injected PUF of density (38+2) Kg/cum using CFC free HFC – 134a/R – 141b blowing agent, the panels having scratch free plastisol coating on outer side. The fan section should be mounted on anti vibration spring isolators and free from main structure. The fan should be backward curved centrifugal fan with air discharge upblast, belt driven with TEFC induction motor of suitable capacity. The coil section consist of 6 row deep coil with min 12 fins/inch duly coated. The filter section consist of pre-filter with 10 micron 90% efficiency and high efficiency filters to remove dust particles down to 5 microns with
minimum efficiency 99% when tested as per BS 6540- Part 1, made out of non woven synthetic / polyster / propylene media sandwitched between HDPE mesh on one side for additional coarse filteration and aluminium expanded mesh on the other side for mechanical support. The other accessories are view port, limitswitch, stainless steel (SS3) drain pan, . AHU shall be provided UVC emitters & fixtures in sufficient quantity so as to provide equal distribution of UVC energy on coil and in the drain pan all as specified and designed capacity. 1 (f) ELECTRICAL DISTRIBUTION SYSTEM (MAIN AC PANEL) - 1 No Manufacture, supplying, fixing in position, connecting, testing and commissioning of Control panels floor mounted, indoor type vermin proof, dust proof (fabricated through CPRI certified manufacturer) housed in 2 mm thick
MS Sheet steel housing and hinged and lockable doors, front opening cable alley and cable glands as required. All interlocking wiring with suitable size of copper wire, timers and control wiring shall be done, aluminium strip for earth continuity to be provided. The bus bar shall be of copper. The control panel shall be suitable for 35 KA fault level at 415 volts for the following: Incoming MCCB with Microprocessor release (Integral overload, short circuite, earth fault& neutural protection) 4 pole of suitable capacity as per approved GA Drg- 01 no Digital type volt meter, Amps meter with SS & CTs with control fuses -01 Set Phase indicating light with control fuses with toggle swich- 01 Set Breaker ON/OFF/TRIP indicating lights complete with control fuses, relays, audio alarm on TRIP KWH meter 0f suitable capacity. BUS BAR TPN copper bus bar with heat shrinkable insulation colored sleeves all as per approved GA drg. Rubber matting 12 mm thick for full lenghth of control panel.
OUTGOING TP MCCB of suitable capacity as per approved GA Drg -3 Nos(including one spare) with operating hadles alongwith Ammeter CT, and indicator lamps RYB for nchiller microprocesser control panel. MCCB 63A415 V 4 pole 25 KA as per GA Drg for APFC panel -01 No 01 No. 63 A/nearest suitable capacity aas per Ga Drg 4 pole MCCB for out going cable for AHU (1 floor) 2 Nos, 40 Amps / nearest suitable capacity as per GA Drg MOCB TP along with amps meter, CT indicator lamps for ON/OFF complete with suitable fully automatic star- delta(FASD) motor starter, OLD, push button for start/ stop, relays with SPPR and phase, reverse preventer etc for chilled water pump. 2 Nos 25 Amps/ nearest suitable capacity as per GA Drg MPCB TP alongwith amps meter, CT indicator lamps for ON/OFF complete with suitable fully automatic star- delta(FASD) motor statrter. OLP, push button for start/ stop, relays with SPPR and phase, reverse preventer etc for cooling towerpumps. 2 MCB 32 Amps TP for spare.
1(g) All as per item No 1(f) above but with following (AHU Panel) -1 No Incoming 1 Mo 63(50-63)Amp NCCB 4 ple 16 KA Digital type volt meter, Amps meter with SS & CTs with control fuses-01 Set Phase including lights with control fuses with toggle swich- 01 Set Breaker ON/OFF/TRIP indicating lights complete with control fuses Bus Bars 100Amp TPN aluminium BB with heat shrinkble insulation colored sleeves. Outgoings 1 No 25 Amps MPCB TP alongwith ammeter ST, indicator lamps for ON/OFF complete with suitable fully automatic star-deltamotor starters, OLP,push button for start/stop, relays with SPPR etc for AHU bowler motor. 2 Nos , 32 Amps MCCB TPN alongwith amps meter, CT,RYB indicator lamps power contractor, OLP push button for start/stop relays etc for humidifier/ heater. 2 Nos- 10 ADP MCB for spare. Rubber matting 12mm thick for full length of control panel- 01 No.
1(j) Earthing earthing complete galvanizedd earth plate clectrode of size 600 x 600 x 6mm thick buried directly in ground earth pit not less than 2.25m below ground level connected to galvanized earth strip of size 25 x4mm by means of bolts, nuts, washers of GI all as shown in electrical plate No 3 of SSr part 1 connected to earth test point complete including earth work, excavation in any type of soil PCC(1:3:6) type CI bed and chamber RCC (1:2:4) type B1 cover 40mm thick including 6mm dia reinforcement and funnel watering pipe etc all as specified and directed -10 each 1(h) Cost of following items also included in rete quoted by the tenderer Suitable capacity presure gauges, vacuum gaugs, thermometers and other indicative devices on refrigerant/ pipe lines all as directed. Under deck insulation shall be carried out in the AHU rooms and cost shall be included in the quoted rate. Providing acoustic insulation with 25mm thick fibre glass riged boards and finished with RP tissue paper and 28 gauge aluminium performated sheet upto 5, from outlet of the air plenium including air plenum for all AHUs. APFC (Auto Power Factor Control) panel suitable for
the complete plant load including all relays and control gears. Strip type heater bank of suitable capacity of AHUs in three banks with necessary copper conductor wiring for banking complete in AHU plenium. Three way mixing valve of suitable size with motorised activator and modilating thermostate control for AHU. Steel tubing MS ERW Class `C’ with all fittings including welding laid on supports. including pipe insulation with 50 mm thick PUF (for pipe below 100 mm diain side bldg) and 75 mm thick PUF for pipes beyond 100 mm dia. Pipes exposed shall be insulated with PUF & covered with chicken mesh and cladded with 0.5mm x 20 mm GI hexagonal wiremesh and cladded with snad, cement, plastering with one coat OBD of sizes. Insulation for pipes with 50 mm thick PUF (for pipe below 100 mm diain side bldg) and 75 mm thick PUF for pipes beyond 100 mm dia. Pipes exposed shall be insulated with PUF & covered with chicken mesh and cladded with 0.5mm x 20 mm GI hexagonal wiremesh and cladded with snad, cement, plastering with one coat OBD of sizes.pipes for condenssor line shall be painted with one coat of red oxide primer and two coat of synthetic paint
Butter fly valve both end flanged and drilled with disc of DI with spoxy coating or CI with nylon coating and seal with nitrile rubber / EPDM of class PN – 1.6 conforming to IS and ISI maked Balancing valves/gate valves duly insulated complete with companion flanges, nuts, bolts, gaskets as per approved Drg. Check valves duly insulated complete with companion flanges, nuts, bolts, gaskets as per approved Drg. Y-strainer duly insulated complete with companion flanges, nuts, bolts, gaskets as per Drg. Automatic air vent in brass construction with nipples, union etc as required at all high points in the pipe lines. The valve shall be such as to have non return valve as integral part of the vent all as per Drg. Air ducting made put of commercial grade GI sheet Zinc coating 180 GSM IS : 277 and factory fabricated as per SMACNA-1195 of 22 SWG thick and 16 SWG for plenum. Ducting wherever passing through un-conditioned space shall be insulated with resin bonded Fibre Glass Wool 25mm thick (density 24Kg/CUM)/ PUF covered with GI chicken wire mesh and cladded with aluminium foil fixed with adhesive tape. Aluminium powder coated double deflection type grills/diffusers complete with MS powder coated with volume control damper for supply air grill / diffusers.
Grills / diffuser without volume control damper for return air grills/deffuser GI duct dampers with extruded aluminium sections for fresh air duct with lovour complete Fire dampers automatic type with fusible link (CBRI Certified) and operated with stainless steel spring made out of 16 SWG GI sheet to be provided in main supply duct interlocked with AHU motor to cut off circulation of air in case of fire. 1 (k) NOTES:-Contractor shall submit the following details duly Approved by NIT/IIT authorities for approval by accepting officer before commencement of work (i) Heat load calculation as per data sheet and bldg drg (ii) Design capacity & type of AC pant (iii) Design capacity of AHUs (ii)Capacity of eqpts such as chiller unit, pumps, AHUs,& cooling tower (iii) Lay out plan of Eqpts (iv) Design & size of Supply air /Return air duct and grills etc (v) Schematic diagram for chilled/cold water line & its size
(vi) Elect load details (vii) GA drg for Main Panel board & AHU panel board (viii)Details of water requirement (ix) Details and brand of eqpts to be incorporated in subject work alongwith catalouge for approval. (x) All Design details and Drgs are duly approved from IIT/NIT Note: for items 1 (a) to 1 (k) (i) All civil works required to install, test and commissioning the equipment like excavation, PCC foundation for equipment, necessary cable ducts with MS covers 6 mm thick duly painted and finishing patch work to match existing specifications including fixing the ducting etc. shall be seemed to be included in the above offer (ii) Necessary water supply connections for the make up water tank and AC/Plant from existing water supply connections not exceeding 10RM from the plant room deemed to be included in the quoted rate. (iii) Suitable supports for holding the ducts and pipes will be provided by tenderer as specified and directed and shall be deemed to be included in the quoted rate. (iv) Size of earth continuity conductor shall be GI strip of 25 x 4 mm for all motors from 5 HP to 25HP and 4 SWG GI wire for motors upto 5HP (v) Refrigeration control wiring copper conductor, PVC insulated, unsheathed, multistranded, 1100V grade single core of size 2.5 Sqmm draw in and including
PVC conduit of suitable size for interlocking arrangement as per standard practice with thermostat, humidstat, balancing valve, blowermotor, pumps starter etc, all as directed shall deemed to be included. (vi) Initial charging of oil and refrigerant shall deemed to be included. (vii)Velocity of air in supply air duct shall not exceed 450m / min (1500 FPM) and velocity at diffuser outlet shall not exceed 150m/min (500 FPM). (viii) Necessary drain connection at each AHU room and AC plant room shall be provided by the tenderer. (ix) Phase I & II (Summer and Monsoon) Testing will be carried out all as specified. (x)Electric and water supply for Phase – I and Phase – II testing will be provided free of cost by the department. (xi)T-bid shall indicate COP of the system offered COP shall not be less than 3.00 (xii)The complete plant is to be installed, tested and commissioned only by the skilled engineer of the main manufacturer of the chiller-packages. Necessary confirmation is to be submitted by the contractor after completion of the work with test certificates before dept undertakes further testing as per tender. Cost is deemed to be included the quoted rate.
Aviation obstruction light:- Aviation obstruction light LED type comprising of aluminium housing with polycarbonate enclosure (Make Bajaj Cat No. BGAV 302 LED), all as specified and as directed.
COMPREHENSIVE MAINTENANCE OF LIFT Comprehensive maintenance of electrically operated goods lift of capacity 3000Kg all as mentioned in relevant item of this BOQ complete all as specified and as directed for First year after expiry of defects liability period
All as per item No.108 here in before but for Second year after expiry of defects liability period
All as per item No. 108 here in before but for Third year after expiry of defects liability period
FUTURE ONE FACILITY MANAGEMENT
Kanika Construction Company
United Sales Corporation
Agarwal Jagdish Construction Company Pvt. Ltd.
CREATIVE BUILDERS
VIJAY CONSTRUCTIONS
M.J.JOY AND COMPANY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
119350257.html
Tender Document • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .