Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.4 LAccepted-AOC MAHESGOTE KRISHNAPUR ROAD NEW TOWN 24 PGS N KOLKATA 700102 | KOLKATA | NORTH 24 PARGANAS | WEST BENGAL | 700102 | ₹4.4 L | L1 | Accepted-AOC PO has been generated |
| 2 | L2₹4.6 LRejected-Finance 4A HARMOHAN GHOSH LANE KOLKATA 700085 | KOLKATA | KOLKATA | WEST BENGAL | 700085 | ₹4.6 L | L2 | Rejected-Finance L2 |
| 3 | L3₹4.8 LRejected-Finance RGM AS 07 BL KA TARULA RAMKRISHNA PALLY RAJBANSI PARA NEWTOWN KOLKATA 700102 | KOLKATA | NORTH 24 PARGANAS | WEST BENGAL | 700102 | ₹4.8 L | L3 | Rejected-Finance L3 |
| Sl No | Description | Qty | Unit | POWER POINT L2 | B.R.CONSTRUCTION L1 | MONDAL ELECTRIC CONCERN L3 |
|---|---|---|---|---|---|---|
| 1.00Construction of 07 nos. of Cable supporting structures | ||||||
| 1.01 | Survey of 33 KV Cable Route as per instruction of the Site Engineer | 180 | Mtr. | 3 ₹540 | 3 ₹540 | 3.5 ₹630 |
| 1.02 | Excavation of soil along the existing cable route for formation of cable trenchs and re-instatement of same cable trench with the excavated soil. (L x 0.75 x 1.2) (L=180) | 162 | Cum | 28 ₹4,536 | 25 ₹4,050 | 28 ₹4,536 |
| 1.03 | Laying & dressing of 33KV 3Cx400sq.mm. XLPE Cable in the excavated cable trenchs as per drawing no. PLN(D)/SS/126 Dated 23.06.2018 and instruction of the site engineer where brick protection required in single line formation. | 200 | Mtr. | 78 ₹15,600 | 65 ₹13,000 | 80 ₹16,000 |
| 1.04 | Supply & fixing of 1st Class Bricks (Kiln Burnt) having proper size & shape suitable for cable protective cover as per instruction of the site engineer. | 4,320 | No. | 10 ₹43,200 | 9.22 ₹39,830.40 | 10 ₹43,200 |
| 1.05 | Making of Outoor type End termination Joint suitable for 33KV. 3x400sqmm. XLPE cable | 4 | No. | 2,299 ₹9,196 | 2,100 ₹8,400 | 2,350 ₹9,400 |
| 1.06 | Making of Straight Through Joint suitable for 33KV. 3x400sqmm XLPE cable | 4 | No. | 2,484 ₹9,936 | 2,300 ₹9,200 | 2,500 ₹10,000 |
| 1.07 | Fixing of Disc Insulator | 21 | Set | 112 ₹2,352 | 105 ₹2,205 | 115 ₹2,415 |
| 1.08 | Erection of conductor including laying, hoisting, stringing, jointing, sagging & tensioning & route clearance iro 200 sq mm ASCR Panther conductor 3 wire syatem | 0.05 | Km | 22,990 ₹1,149.50 | 20,000 ₹1,000 | 25,000 ₹1,250 |
| 1.09 | Relaying & dressing of existing healthy portion of the 33 KV 3 X 400 sq mm cable in the excavated trench as per the instruction of the site engineer | 60 | Mtr. | 54 ₹3,240 | 50 ₹3,000 | 55 ₹3,300 |
Tender Value
₹4.4 L
EMD Value
₹8,849
Closing Date
21 Aug 2025, 2:00 pmClosed
DM, Newtown Division
Newtown Division office, Plot No-I, Action area-II, Rajarhat Kolkata- 700161.
Construction of 07 nos. of Cable supporting structures and laying of 33 KV Cable for connection and charging of 33 KV Feeders to newly constructed bay at Newtown AA-ID 132/33/11 KV sub-station under Newtown Division
2025_WBSED_889013_1
NTD/E-TENDER/2025-26/55/1064 Dated 08.08.2025
Open Tender
CIVIL AND ELECTRICAL WORKS
120 days
Newtown Division office, Plot No-I, Action area-II
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹8,849
Newtown Division office, Plot No-I, Action area-II
8 Apr 2026
13 Aug 2025
25 Aug 2025
13 Aug 2025
21 Aug 2025
13 Aug 2025
18 Aug 2025
Amount
Construction of 07 nos. of Cable supporting structures
Survey of 33 KV Cable Route as per instruction of the Site Engineer
Excavation of soil along the existing cable route for formation of cable trenchs and re-instatement of same cable trench with the excavated soil. (L x 0.75 x 1.2) (L=180)
Laying & dressing of 33KV 3Cx400sq.mm. XLPE Cable in the excavated cable trenchs as per drawing no. PLN(D)/SS/126 Dated 23.06.2018 and instruction of the site engineer where brick protection required in single line formation.
Supply & fixing of 1st Class Bricks (Kiln Burnt) having proper size & shape suitable for cable protective cover as per instruction of the site engineer.
Making of Outoor type End termination Joint suitable for 33KV. 3x400sqmm. XLPE cable
Making of Straight Through Joint suitable for 33KV. 3x400sqmm XLPE cable
Fixing of Disc Insulator
Erection of conductor including laying, hoisting, stringing, jointing, sagging & tensioning & route clearance iro 200 sq mm ASCR Panther conductor 3 wire syatem
Relaying & dressing of existing healthy portion of the 33 KV 3 X 400 sq mm cable in the excavated trench as per the instruction of the site engineer
Supply and Erection of Cable Support Structure including requisite base bolts and nuts
Earthing labour along with supply of Earthing Arrangement ( Mat & Pipe) (For 7 nos Cable Support Structure)
Supply of 33 KV Connectors(Moose to Pather,Panther connectors, Post insulators top panther etc.) and Erection, fixing & fitting of others assorted materials viz. 33 KV PIN Insulator / Post Insulator, Hardware fittings, Bus Connectors Etc. ( Per bay)
Supply of Hardware Single Tension for PANTHER CONDUCTOR
Surface dressing of the ground in any kind of soil including removing vegetation inequalities not exceeding 15 cm depth and disposal of rubbish with in a lead upto 75 m as directed.
Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. In ground floor.
Dismantling all types of masonry excepting cement concrete plain of reinforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. In ground floor.
Removal of rubbish, earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal / Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charge.
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sand stone) including removing spreading or stacking the spoils within a lead of 75m as directed. The item includes necessary trimming the sides of trenches, leveling dressing & ramming the bottom, bailing out water etc. as required complete.a) Depth of excavation not exceeding 1500mm.
Earth work in filling in foundation trenches or plinth with good earth in layers not exceeding 150mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work). (a) With earth obtained from excavation of foundation.
A) Filling in foundation or plinth by silver sand in layers not exceeding 150 mm. as directed and consolidating same by thorough saturation with water ramming complete, including the cost of supply of sand. (Payment to be made on measurement of finished quantity)
Single brick flat soling of picked jhama bricks including removing & dressing bed to proper level & filling joints with powered earth or local sand.
Cement concrete with graded stone ballast (40mm size excluding shuttering). In ground floor. Pakur variety. 1:3:6 proportion.
Ordinary Cement Concrete (mix 1: 1.5: 3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. Pakur variety. Consider a distance of 15 Km from sealdah railway station. In ground floor and foundation.
Ordinary Cement concrete (Mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement, if any, in ground floor as per relevant IS codes. Pakur Variety. Considering 15 km distance from Sealdah.
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc. including supply of rods, initial straightening and removal of loose rust ( if necessary ) cutting to requisite length, hooking & bending to correct shape, placing in proper position & binding with 16 gauge black annealed wire at every inter section complete as per drawing and direction. For work in foundation and up to roof of ground floor/ up to 4mtr mild steel/ Tor steel. JSW/JSPL/ELECTROSTEEL/ELEGANT/SHYAM
Hire & labour charges of shuttering with centering & necessary staging up to 4m. using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, lintels curved or straight including fitting, fixing & striking out after completion of work (up to roof of ground floor.a) 25mm to 30mm thick shuttering without staging in foundation.
Supplying and laying polythene sheet (150 gm /Sqm) over damp proof course or bellow flooring or roof terracing or in foundation trenches.
Plaster (to wall, floor, ceiling etc.) with sand cement mortar including rounding off or chamfering corners as directed and racking out joints or roughening of concrete surface by chipping etc. including throating, nosing and drip course where necessary. Excluding cost of chipping over concrete surface.a) In ground floor.ii) 15 mm thick plaster with (1:6) cement mortar.
Neat cement punning about 1.5 mm. thick in wall, dado, window, sills, floor, drain etc.
POWER POINT (BID ID -6842789)
MONDAL ELECTRIC CONCERN (BID ID -6861688)
stage.html
html • 0.05 MB
technical_2005242.pdf
techsummary_2005242.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 6.46 MB
BOQ_2005242.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid