Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.2 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹33.3 L+₹7.1 L (27.0%)Rejected-Finance | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹35.9 L+₹9.7 L (37.1%)Rejected-Finance | L3 | Rejected-Finance Not being L1 | |
| 4 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Others-Supporting Documents and EMD not submitted as per NIT |
| Sl No | Description | Qty | Unit | SAI RAM CONSTRUCTIONS L3 | S J REDDY L1 | Ms V.Prakash L2 |
|---|---|---|---|---|---|---|
| 1.00 | Taking down existing tar felt, water proofing membrane etc of any description, any type including loose plastering / screed , padding concrete etc if any and removing all loose particles with wire brushes, removing bitumen coating over original RCC slab by grinding, picking, , grinding of mother concrete slab to make surface smooth suitable for applying PU waterproofing coat as per manufacturer's instructions, including removal of debris to a distance exceeding 1.5 km but not exceeding 5KM complete all as specified and as directed. | 2,700 | Sqm | 20 ₹54,000 | 18 ₹48,600 Lowest | 20 ₹54,000 |
| 2.00 | Demolition of Cement concrete (unreinforced) of any description and in any position on roofs including removal of debris complete all as specified and directed. | 70 | Cum | 200 ₹14,000 Lowest | 450 ₹31,500 | 200 ₹14,000 Lowest |
| 3.00 | Taking down cement or cement lime plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc all as specified and directed. | 300 | Sqm | 30 ₹9,000 | 18 ₹5,400 Lowest | 45 ₹13,500 |
| 4.00 | M&L 15mm thick rendering in cement mortar 1:4 on stone masonry wall surfaces or on other than fair faces of brick masonary finished fair and even mixed with Liquid water proofing compound of FOSROC Nitobond SBR at 2% by weight of cement or with equivalent products of Pidilite, Dr fixit Super Latex / Asian paints/ M/s M C Bauchemic / CIPY/ SIKA / Thermax / STP as approved by GE, to be applied as per manufacturer’s instructions.(Supply only of admixure will be measured and paid separately). | 300 | Sqm | 300 ₹90,000 | 252 ₹75,600 | 250 ₹75,000 Lowest |
| 5.00 | M & L for preparing new plastered or unplastered surfaces on walls including cornices and applying two coat of cement base paint over a coat of alkali resistant primer complete all as specified and as directed . | 300 | Sqm | 100 ₹30,000 | 72 ₹21,600 | 54 ₹16,200 Lowest |
| 6.00 | M&L for PCC 1 : 2 : 4 type B-0 ( using 12.5 mm graded stone aggregate) mixed with water proofing liquid as in padding on roofs to maintain slope as in correction layer of the depressed/ undulated portions and in roof kerbs or mud stops, rounded or chamfered on edges etc., finishing the cement concrete even and smooth without using extra cement complete all as specified and as directed. (Note :- Supply only water proofing liquid will be measured and paid separately under respective item only). | 70 | Cum | 4,300 ₹3,01,000 Lowest | 5,400 ₹3,78,000 | 4,500 ₹3,15,000 |
| 7.00 | Supply only of Liquid water proofing compound FOSROC Nitobond SBR at 2% by weight of cement or with equivalent products of Pidilite, Dr fixit Super Latex / Asian paints/ M/s M C Bauchemic / CIPY/ SIKA / Thermax / STP as approved by GE. | 98 | Lit | 80 ₹7,840 Lowest | 126 ₹12,348 | 120 ₹11,760 |
| 8.00 | M&L screed bed or bedding layer of mortar, 15 mm thick, in cement mortar 1:4, over RCC roof slabs for laying water proofing treatment complete all as specified and directed by Engineer-in-Charge. | 2,700 | Sqm | 100 ₹2,70,000 | 180 ₹4,86,000 | 60 ₹1,62,000 Lowest |
| 9.00 | M&L for water proofing treament to walls and on Chajjas / Sunshades as under:-
(i) Preparation of surfaces of walls and on chajjas / sunshades over walls above chajja up to 900 mm and up to 600 mm on either side of chajja width, picking, sweeping, cleaning and washing down with water to remove all loose particles, dust etc complete all as directed by Engineer-in-charge. Surface shall be moist by sprinkling water.
(ii) Applying FOSROC Brushbond Wall guard / roofguard minimum 3 layers or equivalent product of Asian Paints, / M/s MC Bauchemie / CIPY/ SIKA / Pidilite Dr Fixit/ Thermax / STP as per the manufacturer’s instructions. | 250 | Sqm | 900 ₹2,25,000 | 450 ₹1,12,500 | 300 ₹75,000 Lowest |
| 10.00 | M&L for cutting out cracks to V-section upto 5 to 10 mm wide over existing RCC roofs or terracing, cleaning out, grouting with Dr Fixit PU sealant or equivalent. | 200 | RM | 80 ₹16,000 Lowest | 90 ₹18,000 | 80 ₹16,000 Lowest |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
23 Aug 2025, 6:00 pmClosed
GE (AFA) Hyderabad
GE (AFA) Hyderabad, Dundigal, Hyderabad
REPAIR TO ROOF TREATMENT, EXTERNAL WALL PLASTER, RAIN WATER PIPES ETC IN TECHNICAL/ ADM AREA AT AFA HYDERABAD
2025_MES_722867_1
8595/E8
Open Tender
Civil Works
Item Rate
180 days
Hyderabad
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
GE (AFA) Hyderabad
₹80,000
Yes
31 Dec 2025
26 Jul 2025
25 Aug 2025
26 Jul 2025
23 Aug 2025
9 Aug 2025
26 Jul 2025 - 8 Aug 2025
Amount
Taking down existing tar felt, water proofing membrane etc of any description, any type including loose plastering / screed , padding concrete etc if any and removing all loose particles with wire brushes, removing bitumen coating over original RCC slab by grinding, picking, , grinding of mother concrete slab to make surface smooth suitable for applying PU waterproofing coat as per manufacturer's instructions, including removal of debris to a distance exceeding 1.5 km but not exceeding 5KM complete all as specified and as directed.
Demolition of Cement concrete (unreinforced) of any description and in any position on roofs including removal of debris complete all as specified and directed.
Taking down cement or cement lime plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc all as specified and directed.
M&L 15mm thick rendering in cement mortar 1:4 on stone masonry wall surfaces or on other than fair faces of brick masonary finished fair and even mixed with Liquid water proofing compound of FOSROC Nitobond SBR at 2% by weight of cement or with equivalent products of Pidilite, Dr fixit Super Latex / Asian paints/ M/s M C Bauchemic / CIPY/ SIKA / Thermax / STP as approved by GE, to be applied as per manufacturer’s instructions.(Supply only of admixure will be measured and paid separately).
M & L for preparing new plastered or unplastered surfaces on walls including cornices and applying two coat of cement base paint over a coat of alkali resistant primer complete all as specified and as directed .
M&L for PCC 1 : 2 : 4 type B-0 ( using 12.5 mm graded stone aggregate) mixed with water proofing liquid as in padding on roofs to maintain slope as in correction layer of the depressed/ undulated portions and in roof kerbs or mud stops, rounded or chamfered on edges etc., finishing the cement concrete even and smooth without using extra cement complete all as specified and as directed. (Note :- Supply only water proofing liquid will be measured and paid separately under respective item only).
Supply only of Liquid water proofing compound FOSROC Nitobond SBR at 2% by weight of cement or with equivalent products of Pidilite, Dr fixit Super Latex / Asian paints/ M/s M C Bauchemic / CIPY/ SIKA / Thermax / STP as approved by GE.
M&L screed bed or bedding layer of mortar, 15 mm thick, in cement mortar 1:4, over RCC roof slabs for laying water proofing treatment complete all as specified and directed by Engineer-in-Charge.
M&L for water proofing treament to walls and on Chajjas / Sunshades as under:- (i) Preparation of surfaces of walls and on chajjas / sunshades over walls above chajja up to 900 mm and up to 600 mm on either side of chajja width, picking, sweeping, cleaning and washing down with water to remove all loose particles, dust etc complete all as directed by Engineer-in-charge. Surface shall be moist by sprinkling water. (ii) Applying FOSROC Brushbond Wall guard / roofguard minimum 3 layers or equivalent product of Asian Paints, / M/s MC Bauchemie / CIPY/ SIKA / Pidilite Dr Fixit/ Thermax / STP as per the manufacturer’s instructions.
M&L for cutting out cracks to V-section upto 5 to 10 mm wide over existing RCC roofs or terracing, cleaning out, grouting with Dr Fixit PU sealant or equivalent.
Preparation of surfaces by sweeping cleaning and washing down with water to remove dust and loose particles over RCC slab for providing roof treatment, removal of unserviceable debris to outside MD land, and applying bitumen primer @0.30kg/sqm providing and laying 4mm thick APP modified water proofing membrane weight not less than 4.0 kg/sqm reinforced with non woven polyster mat weight not less than 160gm/sqm having softening point not less than 140 Degree centigrade longitudinal tensile strength not less than 800N per 5cm tearing strength of 180N (by torch application method) with minimum of 100mm side lap and 150mm end laps by application of torch. Applying a coat blown grade hot bitumen 90/15 over the membrane @ 1.20kg/sqm and applying a coat of silar reflective bitumenous aluminium paint @ 0.1Kg/sqm all as specified and as per manufacturr's instructions. The membrane shall be inserted in to the wall /parapet wherever required. mouth of rainwater pipes, gutters shall be properly treated to avoid ingress of the water. Note: (i) The rate quoted by the contractor shall be included for dismantling and refixing of PVC water tanks hoisted on roof, taking down and refixing of water tubing and any other fittings on roof as required and no extra shall be paid. (ii) The work shall be carried out complete as per manufacturer’s specifications and application methodology. Execution to be done with authorised trained / skilled applicator of manufacturer as per technical guidance laid by manufacturer. Company guarantee to be given by contractor after completion of water proofing work before payment.
Demolition of RCC of any description , any grade as in water tanks on roof including bases etc.
S & F in repair PVC (SWR) pipes of 110mm dia single socketed in any length with rubber ring joints fixed to walls / floor incl taking down old pipes of any description complete all as specified and as directed
Ms V.Prakash (BID ID -3395906)
SAI RAM CONSTRUCTIONS (BID ID -3389337)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .