| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.5 LAccepted-AOC | L1 | Accepted-AOC SUCCESSFUL BIDDER | |
| 2 | L2₹8.9 L+₹33,328 (3.88%)Rejected-Finance | L2 | Rejected-Finance Unsuccessful Bidder | |
| 3 | L3₹9.0 L+₹40,359 (4.70%)Rejected-Finance | L3 | Rejected-Finance Unsuccessful Bidder | |
| 4 | L4₹9.0 L+₹41,293 (4.81%)Rejected-Finance | L4 | Rejected-Finance Unsuccessful Bidder | |
| 5 | L5₹9.0 L+₹44,173 (5.15%)Rejected-Finance | L5 | Rejected-Finance Unsuccessful Bidder |
Tender Value
₹8.5 L
EMD Value
₹17,000
Closing Date
13 Jul 2024, 6:00 pmClosed
AGE (I) AGARTALA
AGE (I) AGARTALA PIN 901184 C/O 99 APO
MAINTENANCE AND REDEVELOPMENT OF BOREWELL BY AIR COMPRESSOR MACHINE AT VARIOUS PUMP HOUSES AT MIL STN AGARTALA
2024_MES_659705_1
8522/E8
Open Tender
Civil Works - Water Works
Works
180 days
AGARTALA
Please refer Tender Documents
8 documents required · 8 mandatory
₹500
AGE (I) AGARTALA
₹17,000
Yes
9 Sept 2024
15 Jun 2024
15 Jul 2024
15 Jun 2024
13 Jul 2024
29 Jun 2024
Amount
Schedule'A' Part-I: External Water Supply works
Re -development of existing / old bore well by air compressor (air compressor used 8 hrs per bore ) with air line pipe including lifting /lowering existing any capacity of submersible pumps and motor with column pipes of 100mm bore and all related accessories etc ,complete all as specified and directed . Note:- (i). Any tools & plants required to complete the job shall be include the rate of quoted. (ii). Serviceable flanged column pipes 100/80mm bore retrieve shall be reused and rusted/unserviceable column pipes shall be replaced by new and same shall be measured and paid under Sch item No.3.00 as supply only.
Dismantling of unserviceable /worn out/ broken steel rope , supply and fixing of steel wire rope 8 mm dia for guard and tied / binned with submersible motor and pump set complete all as specified and directed.
Supply and fixing 100mm bore ERW mild steel pipe, (3 mtr long) heavy duty, not less than 5.40 mm wall thickness with drilled flanged ends having two cable slots on each flange including taking out old column pipe complete all as specified and directed. .
Supply and fixing 80mm bore ERW mild steel pipe (3 mtr long), heavy duty, not less than 5.40 mm wall thickness with drilled flanged ends having two cable slots on each flange including taking out old column pipe complete all as specified and directed.
Dismantling of air compressor reciprocating type ,single stage ,two cylinder of working pressure of 9 kg /sqcm or 12 kg/sqcm complete with 3 HP electric driven motor ,carrying out repairs by replacing worn out /damaged spare parts ,overhauling ,providing minor parts such as bolts ,nuts & washers etc ,assembling ,testing and commissioning complete all as specified and directed . Note : Make of the spare parts shall be as per existing make / brand of equipment .
Supply only Piston ring set LP for air compressor reciprocating type ,single stage .two cylinder of working pressure 9 kg/sqcm or 12 kg/sqcm complete with 3 HP electric driven motor complete al as specified and directed. Note : Make of the spare parts shall be as per existing make /brand of equipment .
Ditto but Piston ring set HP
Ditto but Guide valve LP
Ditto but Guide valve HP
Ditto but Valve guide screw
Ditto but Bush lining LP
Ditto but Bush lining HP
Ditto but Gudgeon pin LP
Ditto but Gudgeon pin HP
Ditto but Ball Bearing JRNL
Ditto but Oil Seal
Ditto but Seeger ring
Ditto but Locking ring
Ditto but Suction Filter
Ditto but Inter cooler pipe
Ditto but Pressure Switch
Ditto but Pressure Gauge
Ditto but Non Return Valve
Ditto but Delivery pipe
Ditto but Gasket set complete.
Rewinding motor of capacity 3 HP ,AC, 3 Phase ,415 V with super enamelled copper wire ,1100V of same gauge as existing with same number of turns including providing slot/core insulation ,heat varnishing etc and testing complete all as specified and directed .
Supply & fixing in replacement DOL starter AC three phase ,415 V ,5 HP with relay complete all as specified and directed
Supply and laying of galvanised iron tubing, medium grade of 15 mm bore with all fitting, and fixed complete to walls/ ceilings or laid in floors complete all as specified and directed .
Supply & fixing Gun metal globe or gate valve with iron wheel head, screwed both ends of size 15 mm dia complete all as specified and directed.
Supply and connecting flat cable, water proof, 6 Sqmm, PVC insulated & PVC sheathed with electrolytic grade annealed, 3 core, 1100 volt grade, multi stranded copper conductor confirming to IS-694/1990, suitable for submersible pump motors, complete all as specified and directed
Supply & fixing in replacement water pressure gauge 10 kg x 100 mm dia complete all as specified and directed Make: Capston or equivalent.
Supply, installing and testing cast iron Venturi conduit ISI marked suitable for 100mm bore pipe including dismantling unserviceable venturi and removing from site of work complete all as specified and directed Make: RMCo/Kirloskar/Leader/L&T.
NOTES :- 1. The amount of schedule of credit shall be deducted from the total of this BOQ for arriving at contract sum. 2. Unless otherwise specified the rates for PCC shall deemed to include the cost of formwork shuttering etc, required for complete and proper execution of the work. Refer Schedule 'A' notes for details.
M/S Ajoy Acharjee (BID ID -3050569)
SHRI RAJESH DEY (BID ID -3048181)
M/S SANKAR GOPE (BID ID -3051499)
M/S NIYATI NETWORK (BID ID -3051354)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .