| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹54.9 LAccepted-AOC CHANDAN NAGAR OPP IOCL PERTROL PUMP RAMPUR ROAD BAREILLY UP 243001 | BAREILLY | BAREILLY | UTTAR PRADESH | 243001 | L1 | Accepted-AOC Competent committee approved the tender in favour of Ist Lowest Bidder | |
| 2 | L2₹80.6 L+₹15.0 L (22.8%)Rejected-AOC 00 OPP RASHMI HOSPITAL RAYA ROAD LAXMI NAGAR MATHURA UTTAR PRADESH 281204 | MATHURA | UTTAR PRADESH | 281204 | L2 | Rejected-AOC Competent committee rejected the file due to higher rates | |
| 3 | L3₹89.6 L+₹24.0 L (36.5%)Rejected-AOC | L3 | Rejected-AOC Competent committee rejected the file due to higher rates |
Tender Value
₹65.6 L
EMD Value
₹65,630
Closing Date
12 Feb 2024, 5:00 pmClosed
SUPERINTENDING ENGINEER
ELECTRICITY DISTRIBUTION CIRCLE, KATJU MARG, BAREILLY
FOR CHECKING, REPAIRING, OPERHAULING and Annual MAINTENANCE OF 33 KV and 11 KV VCB etc INSTALLED AT VARIOUS 33/11 KV S/S UNDER EDD-Baheri
2024_MVVNL_890928_1
128/EDCB/2023-24
Open Tender
Electrical Works
Item Rate
365 days
WORK
AS PER TENDER FORM
3 documents required · 3 mandatory
₹3,540
SE,EDC
₹65,630
21 Mar 2024
6 Feb 2024
13 Feb 2024
6 Feb 2024
12 Feb 2024
6 Feb 2024
Amount
The work of safe carriage of the following material from CB Ganj store center to work site under the jurisdiction of EDD-Baheri Approx. distance upto 80 Km. Including safe loading and unloading.
11 KV CURRENT TRANSFORMER 600/300/5
11 KV CURRENT TRANSFORMER 400/200/5
11 KV CURRENT TRANSFORMER 200/100/5
11 KV CURRENT TRANSFORMER 300/150/5
11 KV POTENTIAL TRANSFORMER
11 KV CAT-A ENERGYMETER
Erection work
REPLACEMENT OF DEFECTIVE 11 KV CURRENT TRANSFORMER 600/300/5
REPLACEMENT OF DEFECTIVE 11 KV CURRENT TRANSFORMER 400/200/5
REPLACEMENT OF DEFECTIVE 11 KV CURRENT TRANSFORMER 200/100/5
REPLACEMENT OF DEFECTIVE 11 KV CURRENT TRANSFORMER 300/150/5
REPLACEMENT OF DEFECTIVE 11 KV POTENTIAL TRANSFORMER
SUPPLY & REPLACEMENT OF DEFECTIVE 11 KV PANEL O/C + E/F IDMT Relay WITH RETROFITTING ARRANGEMENT
SUPPLY & REPLACEMENT OF DEFECTIVE 11 KV PANEL MASTER RELAY WITH RETROFITTING ARRANGEMENT
REPLACEMENT & SUPPLY OF DEFECTIVE HT HRC FUSE FOR PT OF APPROPRIATE RATING
REPLACEMENT & SUPPLY OF DEFECTIVE HRC FUSE OF DIFFERENT RATING
SERVICING AND REPAIRING OF MECHANICAL SYSTEM FOR PROPER OPENING, CLOSING & TRIPPING OF 11 KV BREAKER
REPLACEMENT AND SUPPLY OF 11 KV VCB CHARGING MOTOR OF APPROPRIATE RATING
REPLACEMENT AND SUPPLY OF DEFECTIVE/BURNT MCB OF APPROPRIATE RATING
REPLACEMENT AND SUPPLY OF DEFECTIVE/BURNT AUXILLARY SWITCH OF APPROPRIATE RATING
REPLACEMENT AND SUPPLY OF DEFECTIVE ANTIPUMPING RELAY
REPLACEMENT AND SUPPLY OF DEFECTIVE SPOUT
REPLACEMENT AND SUPPLY OF DEFECTIVE BUSBAR AS PER REQUIREMENT/DRAWING
REPLACEMENT AND SUPPLY OF DEFECTIVE JAW FOR 11 KV VCB TROLLEY
REPLACEMENT & SUPPLY OF DEFECTIVE INDICATOR
REPLACMENT & SUPPLY OF DEFECTIVE AMPERE METER
REPLACMENT & SUPPLY OF DEFECTIVE VOLT METER
REPLACMENT & SUPPLY OF DEFECTIVE TNC SWITCH
REPLACMENT & SUPPLY OF DEFECTIVE LOCAL /REMOTE SWITCH
REPLACMENT & SUPPLY OF DEFECTIVE BUZZER
REPLACEMENT & SUPPLY OF DEFECTIVE CLOSING COIL (24 V D.C)
REPLACEMENT & SUPPLY OF DEFECTIVE TRIPPING COIL (24 V D.C)
REPLACEMENT & SUPPLY OF DEFECTIVE VACCUM INTERRUPTOR
REPLACEMENT & SUPPLY OF DEFECTIVE TNC SWITCH
SERVCING AND REPAIRING OF ELECTRICAL SYSTEM FOR PROPER METERING, OPENING, CLOSING & TRIPPING OF 11 KV BREAKER INCLUDING PROVIDING OF NECESSARY INTERNAL WIRING, LUGS, FERRULES OF APPROPRIATE RATING AND COLOUR CODING AND OTHER NECESSARY ACCESSORIES. BATTRERY AND BATTERY CHARGER OVERHAULING & MAINTENANCE.
The work of safe carriage of the following material from CB Ganj store center to work site under the jurisdiction of EDD- Baheri Approx. distance upto 30 Km. Including safe loading and unloading.
33 KV O/D VCB 1250 A
ACSR DOG CONDUCTOR
New 33 KV CONTROL PANEL for double t/f
LINE ISOLATOR 800A
33 KV CURRENT TRANSFORMER 400/200/1
ERECTION WORK
INSTALLATION OF 33 KV O/D VCB 1250 A
ACSR DOG CONDUCTOR
INSTALLATION OF New 33 Kv CONTROL PANEL for double t/f
INSTALLATION OF 33 KV line isolator 33 KV (800 Amp.)
REPLACEMENT OF DEFECTIVE 33 KV CURRENT TRANSFORMER 400/200/1
SUPPLY & REPLACEMENT OF DEFECTIVE 33 KV PANEL O/C + E/F IDMT Relay WITH RETROFITTING ARRANGEMENT
SUPPLY & REPLACEMENT OF DEFECTIVE 33 KV PANEL MASTER RELAY WITH RETROFITTING ARRANGEMENT
SUPPLY & REPLACEMENT OF DEFECTIVE 33 KV PANEL AUXILARY Relay WITH RETROFITTING ARRANGEMENT
REPLACEMENT & Supply OF DEFECTIVE CLOSING COIL
REPLACEMENT & SUPPLY OF DEFECTIVE TRIPPING COIL
REPLACEMENT & SUPPLY OF DEFECTIVE MAIN CONTACT BLOCK OF BREAKER
REPLACEMENT & SUPPLY OF DEFECTIVE TNC SWITCH
REPLACEMENT OF DEFECTIVE CONTROL CABLE FORM PANEL TO VCB 2*2.5 SQ MM ARMOURED CABLE
REPLACEMENT OF DEFECTIVE CONTROL CABLE FORM PANEL TO VCB 4*2.5 SQ MM ARMOURED CABLE
REPLACEMENT AND SUPPLY OF VCB CHARGING MOTOR OF APPROPRIATE RATING
REPLACEMENT AND SUPPLY OF DEFECTIVE/BURNT MCB OF APPROPRIATE RATING
REPLACEMENT AND SUPPLY OF DEFECTIVE/BURNT AUXILLARY SWITCH OF APPROPRIATE RATING
REPLACEMENT AND SUPPLY OF DEFECTIVE ANTIPUMPING RELAY
REPLACEMENT & SUPPLY OF DEFECTIVE LED INDICATOR
REPLACMENT & SUPPLY OF DEFECTIVE AMPERE METER
REPLACMENT & SUPPLY OF DEFECTIVE VOLT METER
REPLACMENT & SUPPLY OF DEFECTIVE LOCAL /REMOTE SWITCH
REPLACMENT & SUPPLY OF DEFECTIVE BUZZER
REPLACEMENT & SUPPLY OF DEFECTIVE WTI
REPLACEMENT & SUPPLY OF DEFECTIVE OTI
REPLACEMENT & SUPPLY OF DEFECTIVE MAGNETIC OIL GAUGE OF POWER TF
REPLACEMENT & SUPPLY OF DEFECTIVE BUCHOLTZ RELAY
REPLACEMENT & SUPPLY OF DEFECTIVE MAIN CONTACT BLOCK OF TRANSFORMER
REPLACEMENT AND SUPPLY OF DEFECTIVE BREATHER WITH SILICA GEL
SERVICING OF ELECTRICAL SYSTEM FOR PROPER OPENING, CLOSING & TRIPPING OF 33 KV BREAKERS INCLUDING PROVIDING NECESSARY INTERNAL WIRING, LUGS, FERRULES OF APPROPRIATE RATING AND COLOUR CODING & SERVICING MECHANICAL SYSTEM FOR PROPER OPENING, CLOSING & TRIPPING OF 33 KV BREAKERS & SERVICING 33 KV PANEL FOR PROPER OPERATION OF OPENING, CLOSING, TRIPPING, ALARM, INDICATION OF BREAKER INCLUDING PROPER INTERNAL WIRING OF PANELS AND PROPER WIRING BETWEEN PANELS, DC CHARGER, 33 KV BREAKER, 33 KV CTs, 33 KV PTs, POWER TRANSFORMER OIL TEMPRATURE INDICATOR, WINDING TEMPRATURE INDICATOR, OIL LEVEL INDICATOR, BUCHOLTZ RELAY ETC WITH PROPER CONTOL CABLE, LUGS, FERRULES OF APPROPRIATE RATING AND COLOUR. MAINTENANCE OF LIGHTING ARRANGEMENT IN SWITCHYARD & CONTROL ROOM ALSO AND OTHER IMPORTANT WORKS RELATED TO 33/11KV SUBSTAION
REPLACEMENT OF JARJAR CONDUCTOR INCLUDING HEAVY DUTY PG CLAMP, HEAVY DUTY CONECTOR, ISOLATER JAW ETC COMPLETE
RECTIFICATION OF POWER T/F LEAKAGE
Centrifuging of 10 MVA T/F
Centrifuging of 5 MVA T/F
Painting of All structure of switch yard such as terminal gantry, Bus gantry, Line Isolator, Bus Isolators, Fuse sets, CT Structures, Breaker Structures, LA Structures, etc. with one code of red oxide and two cote of Aluminium paint
M/s Shubham Traders
NATIONAL CONTRACTOR & GENERAL ORDER SUPPLIER
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .