Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.8 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹26.1 L+₹1.8 L (7.42%)Rejected-AOC SARDARPURA 1ST B ROAD NEAR HANUMAN JI KA MANDIR JODHPUR RAJASTHAN 342 003 | JODHPUR | JODHPUR | RAJASTHAN | 342003 | L2 | Rejected-AOC L2 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
22 Oct 2022, 6:00 pmClosed
GE (AF) NO 02 JODHPUR
GE (AF) NO 02 JODHPUR
SPECIAL REPAIR TO BLDG No P-1327, P-1328 (BUNDELA ENCLAVE) AT AF STN JODHPUR AND PROVN OF TIN SHED WITH 02 CEILING FANS AT No 1 AIRMEN MESS OF 32 WING AF, JODHPUR
2022_MES_554200_1
8333/E8
Open Tender
Civil Works
Item Rate
120 days
GE (AF) NO 02 JODHPUR
As per Tender Documents
7 documents required · 7 mandatory
₹500
Yes
GE (AF) NO 02 JODHPUR
₹50,000
Yes
11 Nov 2022
24 Sept 2022
24 Oct 2022
27 Sept 2022
22 Oct 2022
8 Oct 2022
1 Oct 2022 - 4 Oct 2022
Amount
Taking down chowkats or frames with shutters (without taking off shutters from the frames) exceeding 1.5 sqm but not exceeding 4 sqm each and refixing in same opening. after doing suitable repairing by hinges etc or as directed by Engineer-in-Charge
Taking down chowkats or frames with shutters (without taking off shutters from the frames) not exceeding 1.5 sqm each and refixing in same opening. after doing suitable repairing by hinges etc or as directed by Engineer-in-Charge
Taking down shutters of any description exc. 1 sqm & n exc 2 sqm each and refixing in same opening after doing suitable repairing by hinges etc or as directed by Engineer-in-Charge
Taking up or down steel tubing 15mm bore and connections including cleaning for refixing or removing from site.complete all as specified and directed.
Taking up or down steel tubing 20mm bore and connections including cleaning for refixing or removing from site.complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings n. exc. 15 cm thickness (below or above ground level) and removing from site all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing from site and rubbish off the premises.
Taking down cement plaster, any description on brick, concrete or stone walls or ceiling including racking out joints, hacking for key, scrubbing down with water etc and removal of rubbish off complete all as specified and directed.
M&L for preparation of old plastered or unplastered surfaces of walls and applying one coat of white wash.complete all as specified and directed.
M&L for preparation of old plastered or unplastered surfaces of ceiling and applying one coat of white wash.complete all as specified and directed.
M&L for preparation of old plastered and unplastred surfaces of walls and applying two coats of oil emulsion distemper white or tinted including removing existing nails if any nos filling the disturbed surface/holes making good smooth surface complete all as directed .
M&L for preparation of old decorated plastered or unplastered surfaces of walls applying one coat of cement base paint, white or tinted, all as specified and as directed by Engineer-in-Charge. Preparing old surfaces plastered or unplastered surface of wall by brooming down or steel wire complete all as specified and directed.
M&L for preparation of old painted steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying one coat of synthetic enamel paint.complete all as specified and directed.
M&L for preparation of old painted wooden surfaces of any description, over 10 cm in width or girth, not otherwise described and applying one coat of synthetic enamel paint.complete all as specified and directed.
M&L for preparation painted steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying one coat of synthetic enamel paint.complete all as specified and directed.
M&L for preparation painted wooden surfaces of any description, over 10 cm in width or girth, not otherwise described and applying one coat of synthetic enamel paint.complete all as specified and directed.
M&L for hacking out old broken glass (any thickness, size, quality or description) from metal frame glazed with putty including punching or drilling out old glazing pin/spring, clips and providing new ones.complete all as specified and directed.
S&F sheet glass 3 mm thick, ordinary quality and glazing with oil putty or wooden beads supplied with shutters in square n.exc. 0.5 sqm in each pane.
S&F pressed steel frames for doors with one or more rebates including necessary fixing lugs hinges lock strike plate etc for 125 X60 mm complete & fixing also as specified supplied and fixed
S&F pressed steel frames for doors with one or more rebates including necessary fixing lugs hinges lock strike plate etc for 105 X60 mm complete & fixing also as specified supplied and fixed
M&L for cement concrete Type B0 1:2:4 (12.5 mm graded) for filling in pressed steel frame for door complete all as specified and directed.
S&F 35 mm thick factory made , second class hard wood palin framd paneelled shutter (two panel with lock rail and panel of 9 mm BWP commericasl ply or 12 mm veneered particle board with commercial veneering on both face .The size of rail and stile as per IS: 1003 (Part-1) kiln seasoned and chemically pressure treated complete all as specified and directed.
S&F 35 mm thick factory made , second class hard wood and skeleton shutters open rebated and prepared to receive glass gauze etc (without sash bars ) edges of framing plain chamfered or rounded fitted with cut and mitred beads for securing glass etc sizes of members of shutters as specified in SSR Part-I section 8 clause 8.24 (a) supplied and fitted to chowkats
S&F 30 mm thick factory made flush shutter ISI MARKED , solid core construction,with block board core and plywood face panel ,commercial type on both COMPLETE as specified in SSR Part-I section 8 supplied and fitted to chowkats
S&F solid PVC door frame of size 50mm x 47mm made out of 5 mm plain colour PVC sheet reinforced with M.S. square tube, fixing in opening as per specification and drawing.complete all as specified and directed.
S&F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width struck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail. Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded/sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement, and fixing in the frame at site as per specification & drawing.
S&F factory made steel windows with side hung shutters including projecting type hinges with steel handle and steel peg stay complete with glazing bars dovetailed or weld complete all as specified and directed.
S&F factory made steel windows with side hung shutters including projecting type hinges with steel handle and steel peg stay complete with out glazing bars dovetailed or weld complete all as specified and directed.
S&F framed work such as grills grating etc with ends of bars shoulder and /or riveted or forged into spikes framed guard bars barred iron door ladders framed baluster walk ways railing framed work of water tank stand similar work conforming to Fe-290 Gde E-165 complete all as specified and directed.
S&F of sheet glass 3.00 mm thick ordeiary quality and glazing oil putty not exceeding 0.50 sqm each panecomplete all as specified and directed.
S&F of galvanized mild steel wire cloth 0.63 mm nominl dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks or galavenied wire staples complete all as specified and directed.
M&L powder coated anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc complete and all as specified.
S&F 300 mm long aluminium alloy anodized silding door bolt with hasp staple (bolt type ) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts and sliding bolts of extruded sections or casr aluminium alloy complete all as specified and directed.
S&F for 100 mm long butt hinges, medium weight stainless steel complete all as specified and directed.
S&F aluminium handles, cast type, anodized, of size 150mm.complete all as specified and directed.
S&F 200 mm long aluminium, anodized, barrel tower bolts of extruded section and fixed.
S&F 300 mm, mild steel, ordinary rat tail rod pattern springs including roller and roller plate complete.
S&F in repairs MS peg stay with 3 to 5 hooks fixed to doors /wall with screws complete all as specified and directed.
S&F floor door stopper, with 150 mm long cover plate, of aluminium alloy body and tongue, anodized, with hard drawn steel spring, fixed in floor.complete all as specified and directed.
Resecuring or easing & adjusting without taking down shutters of any description exc 1 sqm and n exc 2 sqm each complete all as specified and directed.
S&F in repairs aluminium handles, cast type, anodized, of size 150mm.complete all as specified and directed.
S&F in repairs 300 mm long aluminium alloy anodized silding door bolt with hasp staple (bolt type ) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts and sliding bolts of extruded sections or cast aluminium alloy
S&F in repairs 150 mm long aluminium, anodized, barrel tower bolts of extruded section and fixed.
S&F in repairs galvanised mild steel wire cloth, 0.56 nominal dia of wire and average width of aperture 1.00 mm and fixed with tinned tacks or galvanised wire staples
Welding in repairs exc 2.5 cm & n exc 5 cm in length & thickness of metal n.exc 6 mm all as specified and directed by Engr-in-charge
S&F in repairs 15 mm bore bib taps, cast copper alloy, chromium plated, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule.
S&F in repairs, 15 mm bore stop valve, fancy type, chromium plated with long shank and cup screwed down, high pressure with crutch or butter fly handle, screwed both ends for iron pipe or for unions.complete all as specified and directed.
S&F in repairs, 15 mm bore stop valve, fancy type, chromium plated with long shank and cup (concealed type), screwed down, high pressure with crutch or butter fly handle, screwed both ends for iron pipe or for unions.complete all as specified and directed.
S&F in repairs 20 mm dia gun metal globe or gate valve with iron wheel head screwed both ends for iron pipescomplete all as specified and directed.
S&F in repair brass chromium plated shower rose of 125 mm size with swivel joint including fixing to steel pipe or union.complete all as specified and directed.
S&F in repairs brass chromium plated tubular towel rail 20 mm dia D type 60 cm long between flanges complete all as specified and directed.
S&F in repairs PVC connection 15 mm size with PTMT nuts of length 450 mm.
S&F in repairs grating doom 125 mm dia with / without waste hole of PTMT (min wt 40 gms)complete all as specified and directed.
S&F in repairs vitreous china wash basin, white, flat back, size 550x400mm including brackets, cutting for and pinning in ends of brackets or erecting stand, brass chromium plated perforated waste coupling/ fittings 32 mm dia with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed and PVC waste pipe of 32mm bore and of suitable length, 15mm bore pillar tap, cast copper alloy with capstan heads, chromium plated, screwed down high pressure, with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks and fly nuts, screwed for iron pipe PVC connection 15 mm size with PTMT nuts of length 450 mm.complete all as specified.
S&F in repairs vitreous china squatting pan, ‘Orissa’ pattern, size 580 mm x 440 mm, white with integral foot rests, including PVC 'P' trap, embedded and set in PCC 1:5:10 type E-2 and making good to floor including removing rubbish.complete all as specified and directed.
S&F in repairs PVC valveless, syphonic action type, flushing cistern, low level, 10 litres capacity, white, with inlet, ball valve, float and handle including brackets.complete all as specified and directed.
S&F in repairs sheet glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12 cm wide with chromium plated bracket guard and railing 60 cm longcomplete all as specified and directed.
S&F in repair sink made of stainless steel 1.00mm thick kitchen or laboratory with plugs, washers and wastes, including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 495x420 mm, bowl size 410mm x 330 mm x 160 mm and PVC waste pipe of 32mm bore and of suitable length, complete all as specified.
Dismantling of cat iron or reinforced concrete drain pipe, jointed in cemented mortar and taking out of trenches or in vertical position all as directed by the engeer incharge
S&F in repair for PVC (SWR) pipes 110 mm dia single socketed, in any length with rubber ring joints laid in trenches or in floors
S&F in repair for PVC (SWR) pipes 110 mm dia single socketed, in any length with rubber ring joints fixed in walls
S&F in repair for PVC (SWR) pipes 75 mm dia single socketed, in any length with rubber ring joints laid in trenches or in floors
S&F in repair for PVC (SWR) pipes 75 mm dia single socketed, in any length with rubber ring joints but fixed in walls
S&F in repair for PVC (SWR), junction single, (Single T) with door 110 mm dia equal or unequal
S&F in repair for PVC (SWR), junction single, (Single T) with door 75 mm dia equal or unequal
S&F in repair for PVC (SWR) door bends 110 mm dia
S&F in repair for PVC (SWR) door bends 75 mm dia
S&F in repair for PVC (SWR) Cowl 110 mm dia complete all as specified and directed.
S&F in repair for Reducer 100 mm dia complete all as specified and directed.
S&F in repairs cast iron floor trap, 75 mm dia of outlet, with grating including jointing to waste pipe fixed in cement concrete type B1(1:2:4).complete all as specified and directed.
S&F in repairs cast iron nahani trap, 75 mm dia of outlet, with grating including jointing to waste pipe fixed in cement concrete type B1(1:2:4). complete all as specified and directed.
S&F in repairs 75 mm bore cast iron bend (any radius) with duck’s foot or heel rest with oval access door.complete all as specified and directed.
S&F in repairs cast iron branch pieces, single (equal or unequal) ordinary or inverted (spigot or socket type) or with parallel branches for 75 mm bore pipe.complete all as specified and directed.
S&F in repairs cast iron branch pieces, single (equal or unequal) ordinary or inverted (spigot or socket type) or with parallel branches for 100 mm bore pipe.
S&F 500 litres capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top), hoisted and fixed in position all as specified in SSR Part-I, connecting up pipes including 20 mm bore ball brass valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic plastic ball screwed for iron pipe and fixed. (Minimum weight of ball valve - 210 gms)
Supply and laying 15 mm bore tubes, galvainzed steel, medium grade, with all fittings and fixed complete on walls and ceilings or laid in floors all as specified and directed.
Supply and laying 20 mm bore tubes, galvainzed steel, medium grade, with all fittings and fixed complete on walls and ceilings or laid in floors all as specified and directed.
S&F in repairs stainless steel plate rack 0.56mm thick of standard pattern of size 788x915x254 mm complete
M&L for water proofing treatment of sunken floor of WCs bathroom etc by applying of the following specifiaction and testing :- (i) Cleaning of sunken floor surface with mechanical means i.e wire brush/air blower etc and remove all loose/unsound material dirt dust etc. (ii) Applying cement slurry mixed with acrylic based polymer modified cementious composite compund coating Hydroproof Xtra of FOSROC /Equivalent of Dr Fixit of Pidilite industries Ltd in the ratio 1:2:4 (one part of acrylic polymer : two part of water and four part of cement) (iiii) First layer of cement slurry @0.444 kg /sqm mixed with acrylic based modified cementious composite compund @0.222 litre/sqm and allow it to air dry for 4 hour. (iv) Second layer of cement slurry @0.222 kg /sqm mixed with acrylic based modified cementious composite compound @0.111 litre/sqm and allow it to air dry for 4 hour followed with water curing for 48 hours (v) 200 micron thick polytgen film shall be pasted with help of adhesive over treatment . Note:- Joints of WC/Trap/Soil waste shall be prperly sealed with sealing compund . Testing of all traps and joints and sunken slab shall be done as per IS-1742 before filling and tiling work.
M&L for plain cement conrete 1:5:10 type E-2 (using 40 mm graded broken bricks aggregate ) as in foundation and mass concrete complet all as specified and as directed
M&L for 25 mm thick PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate in sub floors.complete all as specified and directed.
Supply and laying 32 mm bore tubes, galvainzed steel, medium grade, with all fittings and fixed complete on walls and ceilings or laid in floors all as specified and directed.
M&L for joint free non skid ceramic tiles, coloured, 7 to 8 mm thick in floors etc. (square/rectangular) area of each tile exc. 0.06 sqm but n. exc. 0.11 sqm, set & jointed in neat cement slurry & pointed in white or coloured cement to match over and including 15mm thick screed bed in CM 1:6 complete all as specified and directed.
M&L for glazed ceramic tiles, coloured, 350x250x7mm/450x350x7mm thick on vertical surfaces such as skirtings, dados and risers to steps etc, set & jointed in neat cement slurry & pointed in white or coloured cement to match over and including 10mm thick rendering in CM 1:4 on stone masonry surfaces.complete all as specified and directed.
M&L for rendering 15 mm thick in CM 1:6 on stone masonry surfaces finished even and smooth without using extra cement.
S&F in repairs 15 mm bore ball valve high pressure of PTMT with epoxy coated aluminium rod &high density plastic ball screwed for iron pipe and fixed. (Minimum weight 210 gms )
S&F in repairs drapery rod in any length, high strength MS pipe with corrugated PVC extrusion having outer dia 20 mm with plastic ring of ABS plastic of dia 56 to 58 mm all as directed by Engineer-in-Charge.
S&F in repairs decorative finals ABS plastic in matching colour of steel powder quoted paint of same colour of rod or as directed by Engineer-in-Charge.
Dismantling wrought steel & iron or mild steel work of any description not otherwise provided for
Dismantling plain or corrugated steel sheeting any gauge thickness nanital or similar pattern roof coverings
Excavating in post holes (or similar holes ) each n exc 0.5 cum getting out returning filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25 cm for hard /dense soil
M&L for cement concrete type D2 1:4:8 (40 mm graded aggregate) in foundation filling and mass concrete .
M&L for cutting holes into or through brick walls built in cement mortar and making good in cement conrete 1:2:4 type B-1
M&L for steel work in tubular trusses purlin rafters including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS 1161 1979 grade st -240
S&F pre-painted galvalumne aluminium zinc coating GI based corrugated steel sheet 0.5 mm thick of any colour having tensile strenght of 550 Mpa as in roof covering /cladding to wall fixed with self screws as specified
M&L for Plain cement concrete type-C-2 1:3:6 (40 mm graded aggregate ) thickness 75 mm as in sub base
M&L for screed bed or bedding layer of mortar 20 mm thick for laying floor finishes CM 1:4
M&L for machine cut kota stone slab flooring 20 -25 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigmenst to match the shade of the slab including rubbing and polishing complete
M&L for kota-stone slab 20-25 mm thick in riser of steps skirting dado and pillar laid over cement screed and jointed with ditto as per above item
M&L for providing and laying 60 mm thick factory made chamefered edge cement concret paver block of M-35 grade with approved colour design & pattern as in footpath parks lawns drive ways or lighttraffic parking etc of required strength thickness & size shape made by table vibratory method using PU mould laid in required colour & pattern over and including 50 mm thick compacted bed of fine sand comapcting and proper embedding / laying of interlocking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator filling the joints with sand and cutting of paver blocks as per required size and pattern finishing and sweeping extra sand
M&L for framed work as in door or gates of angle or other section with gusset plate rails braces etc complet drilled for fixing of steel sheeting or other covering . Doors etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings 9 exclusive of steel sheeting or other covering running rails and guides ) and hanging also fastening and fixing complete grade Fe-290 (Gde E-165)
S&F in repairs galvanised mild steel wire cloth, 0.56 nominal dia of wire and average width of aperture 1.00 mm and fixed with tinned tacks or galvanised wire staples
M&L for preparation of new painted steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coat of synthetic enamel paint.
M&L for PCC block masonary with solid blocks exc 10 cm in width 1:3:6 Type C1 20 mm graded aggregate and setting in mortar complete .
M&L for preparation of new decorated plastered or unplastered surfaces of walls applying two coat of cement base paint, white or tinted, all as specified and as directed by Engineer-in-Charge. Preparing old surfaces plastered or unplastered surface of wall by brooming down or steel wire
Taking down carefully copper/aluminum point wiring (Light/ fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc, stacking at site for reuse or removing materials to store for keeping in for taking credit and making good the disturbed surfaces / walls/ floors etc,.
Taking down carefully Ceiling fan/Exhaust fan by disconnecting electrical connections, unsecrewing from position, stacking carfully at site for reuse of serviceable fans or dismantling blades and removing fan and blade to E/M Store yard all as directed and specified.
Taking down carefully Electric geyser by disconnecting electrical connections & water connections unsecrewing from position, stacking carfully at site for reuse of serviceable geyser or removing geyser to E/M Store yard all as directed and specified.
Taking down carefully Enegry meters by disconnecting electrical connections, stacking carfully at site for reuse of serviceable meters or removing meters to E/M Store yard all as directed and specified.
M&L for channel or grooves cutting upto a depth of 2.5 cm and width not exc 15cm into brick/concrete/stone masonary walls, with or without re-inforcement and trimming surface as required, including concealing PVC conduit 20/25mm dia with required accessories (like junction boxes/bends etc) and plastering in 1:4CM, applying two coats of approved quality white putty for making good with smooth finish to match with the existing specification of wall surface all specified and directed by engr-in-charge. Note : Rate of PVC Conduit included in relavant point wiring and shall not be paid separately.
M&L for point wiring with 1.5 Sq. mm, multi-stranded copper conductor, single core, PVC insulated and unsheathed cable for phase and neutral, including 1.5 Sq. mm PVC insulated unsheathed multistranded copper conductor single core cable as earth continuity conductor (in green color) connected to common earth dolly, drawn in surface/concealed conduit Heavy duty (HMS Grade), GI terminal boxes not less than 1.0mm thick fixed flush to wall surface, covered with & including 3 mm thick plastic laminated sheet top cover or including modular plates of required size for mounting switch and sockets etc. complete all as specified and directed for following : - Note : Quoted rates deems to be included cost of modular plate or hylem board for mounting switches, sockets & regulators as required at site. Cutting into chases required for concealing heavy duty (HMS Grade) PVC conduits and making good to damaged surface shall be measured and paid separately under relavant item.
(a) One light / fan point controlled by one switch one way.
(b) One light point controlled by two Nos 5 Amps switch two way
(c) One 3 pin 5 Amp switch & socket outlet on same board with other switches.
(d) One 3 pin 5 Amp switch & socket outlet on Independant board.
(e) One bell point controlled by one switch 5 Amps bell push.
All same as per item ser No112 here-in-above but wiring using 2.5 sqmm multi-stranded copper conductor, single core, PVC insulated and unsheathed cable, including 2.5 Sq. mm PVC insulated unsheathed multistranded copper conductor single core cable as earth continuity conductor (in green color) connected to common earth dolly for 6 pin, 15/16 Amps socket outlet on independant board.
All same as per item ser No 112 here-in-above but wiring using 4.0 sqmm multi-stranded copper conductor, single core, PVC insulated and unsheathed cable, including 4.0 Sq. mm PVC insulated unsheathed multistranded copper conductor single core cable as earth continuity conductor (in green color) connected to common earth dolly for two pin earth metal clad plug & socket point for AC/Geysers.
S&F Switch piano, flush type, single pole, one way, 6 Amp.
S&F Switch piano, flush type, single pole, two way, 6 Amp.
S&F Switch piano, flush type, single pole, one way, 16 Amp.
S&F Socket outlet 2/3 pin, 2-in-1, 5/6 Amp, flush type.
S&F Socket outlet 6 pin, mulitpurpose 6/16 Amp, flush type
S&F bell push, 6 Amps, 2 Module
S&F Ceiling rose surface bakelite 65x50mm three terminal.
S&F electronic fan regulator modular stepped type 120 watt, two module.
S&F Lamp holder insulated PVC/Polycarbonate/bakelite body, fixed on PVC round or squre box using necessay screw & gutti complete all as specified.
S&F electronic Bell Bul-Bul music, 230 volt, single phase.
M&L for wiring with TV coaxial RG-06, electrolytic grade solid annealed copper conductor having single strand of 0.7 mm dia, PVC insulated, aluminium foiled and aluminium wire braided, overall PVC sheathed cable complete passing through PVC conduit from TV Socket to dish antena on roof of building complete all as specified. (20mm conduit pipe inside building shall be concealed in wall surface and 32mm common conduit from external surface duly fixed with GI Saddles is deems to be included in quoted rates)
Hanging only ceiling fans, 1200mm sweep, complete with three blade, down rod, accessories and making connection from ceiling rose or connector to fan using three core 0.75sqmm copper stranded conductor PVC insulated and PVC sheathed flexible wire complete all as specified. NOTE: Serviceable ceiling fan taken down agaist item No106 shall be re-used after necessary cleaning and servicing at AGE E/M store yard.
Fixing only exhaust fan 300/450mm sweep, Steel/PVC body AC single phase 230V of size 300m using 4 Nos 10mm x 100mm long wall fasteners, nut and washers and connecting up using flexible three core 0.5sqmm copper stranded conductor PVC insulated and PVC sheathed flexible wire through PVC flexible conduit from ceiling rose/connector to fan complete all as specified. NOTE: Serviceable exhaust fans taken down agaist item No 106 shall be re-used after necessary cleaning and servicing at AGE E/M store yard.
Installation only Electric Storage type water heater (Geysers) 25/50 Ltr capacity with standard fixing accessories including suitable size wall fastener bolts & Nuts, gutties etc complete all as specified and directed. NOTE: Serviceable geysers taken down agaist item No109 shall be re-used after necessary cleaning and servicing at AGE E/M store yard.
Fixing only Electric energy kWH meter Single phase/three phase 10 to 60 Amps, including making connection of incomming and outgoing wiring circuits using single core PVC insulated copper multistranded cable of size 6.0 sqmm and necessary lugs, including submission of kWH reading details of old unserviceable taken down meter and new installed meter to AGE E/M all as specifed and directed. Note : Serviceable meters taken down agaist item No110 shall be re-used after necessary cleaning and servicing at AGE E/M store yard.
Fixing only light fitting any type, connecting up with twin core PVC insulated and PVC sheathed flexible copper conductor cable of suitable size from ceiling rose complete all as specified. Note : Serviceable light fittings taken down against item No 105 shall be used at site as directed by engr-in-charge.
Supply and fixing LED light fitting wall /roof mounted, 1 x 20 watt including LED tube with driver complete suitable body robust, corrosion resistant, superior finish and without any cracks or through holes. The system wattage of fitting should not be more than 20 watt ± 10%, surge protection of minimum 2 kV power factor should be more than 0.90 cool white colour, total harmonic distoration (THD) should not be more than 15%, lumen output should not be less than 90 lumens per watt, total input voltage range 140-280V AC, colour rendering index should not be less than 80, corelated colour should be minimum 6000 degree kelvin complete
Supply and fixing LED light fitting wall /roof mounted, 1 x 9/10 watt including LED tube with driver complete suitable body robust, corrosion resistant, superior finish and without any cracks or through holes. The system wattage of fitting should not be more than 20 watt ± 10%, surge protection of minimum 2 kV power factor should be more than 0.90 cool white colour, total harmonic distoration (THD) should not be more than 15%, lumen output should not be less than 90 lumens per watt, total input voltage range 140-280 V AC, colour rendering index should not be less than 80, corelated colour should be minimum 6000 degree kelvin complete all as specified
S&F Building security light fittings, with pressure die cast aluminium housing, suitable for 25 W LED, complete pre-wired, incl suitable bracket for fixing light on wall or any indicated locaction all as specified and as directed by Engr - in Charge complete
S&F LED light fitting 9/10W bulkhead luminaires size 230x100mm including inbuild LED light driver perfect interior and exterier application connecting up with three core flexible copper conductor cable of suitable size complete
M&L for Sub main wiring with approved colour coding as per IS, single core FRLS PVC insulated flexible multistranded copper conductor 1.1 KV grade drawn through & including PVC grey conduit heavy duty with necessary accessories (like bend, juction boxes etc) including taking down old unsv submain wiring complete all as specified for Two runs of 6.0 Sq.mm main cable alongwith one run of single core 6.0 Sq.mm for continuous earth wire in green color.
Supply and replace sheet metal enclosures with socket plug top, and MCBs single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB upto 20 Amps, 240 Volt capacity fixed flush to wall surface including making good to damaged surface of wall to match with existing specification and tested on completion complete including taking out old all as directed.
Supply and replace sheet metal enclosure distribution board for 240 volts, 8 way horizontal type, double door, single pole and neutral with 200 Amps rated neutral copper bus bar for housing MCB and fixed flush in wall surface, and tested on completion complete including taking out old all as directed.
M&L for MCB SPN/DP 40 to 63 Amps 240 volts, 10 kA rupturing capacity providing in DB complete including connection & testing all as specified.
Supply and fixing MCB single pole 6-32 Amps, 240 volts, 10 kA rupturing capacity providing in DB complete including connection & testing all as specified.
Material and labuor for earthing complete with Galvanized Steel earth plate electrode 600x600x6mm thick buried directly in ground (earth pit not less than 2.25 M deep below ground level) with top edge of the plate not less than 1.5 M below normal ground level and filled with 15cm thick alternate layers of charcoal and salt, connected & including GI wire earth lead 4.0mm dia by means of bolts, nuts, check nuts and washers made of galvanized iron protected by 15mm dia GI Pipe (light grade). Earth plate shall be surrounded by alternate layers of charcoal or coke and common salt in 15cm thick in layers & 15cm of widht all aurround of earth plate including 20mm dia GI light grade pipe for watering and including funnel, wire mesh, necessary earth work in any type of soil, Pre-cast RCC cover duly re inforced with 8mm dia TMT Bar @150 mm c/c both ways, one lifting handle made of 8 mm dia TMT bar embedded in cover slab, Earth Pit of PCC (1:3:6) type C2 (using 20mm graded crushed store aggrgate) complete all as specified and as shown in electrical plate No-3 of SSR Part-I including testing on completion. Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) The unit rate includes earthing lead & protection pipe upto 7.5 metre from top of earth plate.
M&L for point wiring with 1.5 Sq. mm, multi-stranded copper conductor, single core, PVC insulated and unsheathed cable for phase and neutral, including 1.5 Sq. mm PVC insulated unsheathed multistranded copper conductor single core cable as earth continuity conductor (in green color) connected to common earth dolly, drawn in and including Pvc casing & Caping, GI terminal boxes not less than 1.0mm thick fixed flush to wall surface, covered with & including 3 mm thick plastic laminated sheet top cover or including modular plates of required size for mounting switch and sockets etc. complete all as specified and directed for following : - Note : Quoted rates deems to be included cost of modular plate or hylem board for mounting switches, sockets & regulators as required at site. Cutting into chases required and making good to damaged surface shall be measured and paid separately under relavant item.
(a) One light / fan point/exahust fan , controlled by one switch one way.
(c) One 3 pin 5 Amp switch & socket outlet on same board with other switches.
(d) One 3 pin 5 Amp switch & socket outlet on Independant board.
All same as per item ser No 141 here-in-above but wiring using 2.5 sqmm multi-stranded copper conductor, single core, PVC insulated and unsheathed cable, including 2.5 Sq. mm PVC insulated unsheathed multistranded copper conductor single core cable as earth continuity conductor (in green color) connected to common earth dolly for 6 pin, 15/16 Amps socket outlet on independant board.
S&F ceiling fan of 1200 mm sweep,copper winding , induction motor type, BEE approved, single phase, AC supply, 240 Volt, including canopies, three number blades, down rod as required at site , double ball bearing with capacitor of 2.5 M fd and making connection with and including PVC insulated PVC sheathed copper conductor flexible cable from ceiling rose or connector to fan including marking of MES number complete all as specified. NOTE: I)The length of suspension rod shall be as per site requirement.II)New fan shall be fixed at the location/BLDG from where retrieved fanreceived under item no 30(NOTE - Cat part and model no shall be approved by GE for make mentioned in APPENDIX of tender .)
VIKAS CONSTRUCTION CO.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .