Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.3 CrAccepted-AOC C1 C2 48 KOSABADI MAHARANA PRATAP NAGAR KORBA CHHATTISHGARH | KORBA | KORBA | CHHATTISGARH | 495677 | L1 | Accepted-AOC TECHNO COMMERCIALLY ACCEPTED L1 BIDDER | |
| 2 | L2₹21.4 Cr+₹1.0 Cr (4.99%)Rejected-Finance 202 KUMAR HOUSE CENTRAL MARKET PRASHANT VIHAR DELHI 110085 | DELHI | DELHI | DELHI | 110085 | L2 | Rejected-Finance QUOTED RATE IS HIGHER THAN L1 BIDDER | |
| 3 | L3₹21.4 Cr+₹1.1 Cr (5.33%)Rejected-Finance | L3 | Rejected-Finance QUOTED RATE IS HIGHER THAN L1 BIDDER | |
| 4 | L4₹22.4 Cr+₹2.1 Cr (10.3%)Rejected-Finance 15 402 ASHOKA RATANA VIDHAN SABHA ROAD SHANKAR NAGAR RAIPUR 492007 | RAIPUR | RAIPUR | CHHATTISGARH | 492007 | L4 | Rejected-Finance QUOTED RATE IS HIGHER THAN L1 BIDDER | |
| 5 | L5₹24.3 Cr+₹4.0 Cr (19.4%)Rejected-Finance 83 DEVI NAGAR NEW SANGANER ROAD JAIPUR 302019 | JAIPUR | JAIPUR | RAJASTHAN | 302019 | L5 | Rejected-Finance QUOTED RATE IS HIGHER THAN L1 BIDDER |
| Sl No | Description | Qty | Unit | R.R. ENGINEERS AND SURVEYORS L4 | Suncity Urja Private Limited L5 | MAA CHINNMASTIKA JV L3 | ADEPT POWER PRIVATE LIMITED L2 | Engineers and Consultants L1 |
|---|---|---|---|---|---|---|---|---|
| 1.00A. WORK & SERVICES | ||||||||
| 1.01 | a.) Detailed survey of the area, within the battery limits & submission of reports (Complete work as per Tender document) b.) Sub soil exploration, field and laboratory testing of samples & submission of reports (Complete work as per Tender document) | 1 | LS | 4,00,000 ₹4,00,000 | 5,00,000 ₹5,00,000 | 1,00,00,000 ₹1,00,00,000 | 2,50,000 ₹2,50,000 Lowest | 5,00,000 ₹5,00,000 |
| 2.00B. DESIGN & ENGINEERING COST | ||||||||
| 2.01 | a). Preparation and submission of system engineering drawings as per system requirements
b). GA & detail engineering designs and drawings of all civil and structurals included in the system and scope of works (Complete details of the system) c). G.A. & detailed engineering designs and drawings including working and maintenance manuals of (Complete details of the system) :
i) all individual equipment ( Electricals)
ii) Fire-Fighting System
iii) Earthing system & Lightening protection system
iv) Cabling System
v) Illumination system & Elerical Wiring Drawing of sub-station building
vi) Single Line Diagram & GA Drawing of the switchyard
vii)Any other system/unit to match the scope of work & requirement
d).Documentation as per tender specification, complete as per scope of works | 1 | LS | 18,00,000 ₹18,00,000 | 10,00,000 ₹10,00,000 | 3,75,00,000 ₹3,75,00,000 | 10,00,000 ₹10,00,000 | 5,00,000 ₹5,00,000 Lowest |
| 3.00C. CIVIL & STRUCTURAL WORKS | ||||||||
| 3.01 | a). Earthwork in cutting in all types of soil and rock b). Earthwork in filling c). Sand filling d). PCC (M 10 and higer grade) at all levels as per system requirement e). RCC (excluding reinforcement) at all levels as per system requirement (M20 grade and above) including shuttering f). Supply, bending, binding and placing of Tor steel in position g).Supply, fabrication and erection of structural steel at all levels as per system requirement
h). Masonary work i) Pavement in substation | 1 | LS | 80,00,000 ₹80,00,000 | 2,50,00,000 ₹2,50,00,000 | 3,00,00,000 ₹3,00,00,000 | 1,15,00,000 ₹1,15,00,000 | 5,00,000 ₹5,00,000 Lowest |
| 3.02Developmental work and infra-structure as per tender document | ||||||||
| 3.02 | a). Site development:- earthwork in excavation and banking for leveling & dressing
b). Gravel packing in switchyard and Dyke Wall c). Roads and Culverts and Pathways d). Water supply for industrial, drinking and firefighting puposes including provision for deep bore-well, pipelines, ground water tank, pumps & pump houses with all electricals.
e). Dwarf Wall f). Substation building g).Security Post h). Drainage arrangement i). Boundary wall, Fencing with barbed wire & gates J). Cable Trenches k). Lighting and Lightning Towers l). RCC foundation for Steel Structures and transformers in outer switchyard m). PCC foundation for Lightening and lighting towers n).Retaining wall o).Chain linked fencing & Gate p). Anti-weed treatment q). Soak Pit for transformers r). Sewerage
s). DG Shed
t). Parking Shed
u). Pump House v). Miscellaneous | 1 | LS | 3,88,00,000 ₹3,88,00,000 | 3,10,00,000 ₹3,10,00,000 | 3,00,00,000 ₹3,00,00,000 | 1,50,00,000 ₹1,50,00,000 Lowest | 7,00,00,000 ₹7,00,00,000 |
| 4.00D. PLANT & MACHINERY ( SUPPLY) | ||||||||
| 4.01 | 33 kV side comprising of following:
i. Isolators, 33 kV (nominal),3 poles, pole mounted, 1250A,25kA,
arrangement for interlocking with 33 kV Vacuum Circuit breaker- 10 Set ii. Isolators, 33 kV (nominal), 3 poles, pole mounted, 1250A,25kA, arrangement for interlocking with 33 kV Vacuum Circuit breaker with Earthing switch -08 Set.
iii. Isolators, 33 kV (nominal), 3 poles, pole mounted, 1250A,25kA, with D.O. Fuses. -06 Set. iv. Lightning Arrestors, station class, 30 kV,10 kA, suitable for 33kV, solidly earthed (each set consists of 3 nos.) with counters/surge monitors -14 Set.
v. Current transformers,33 kV out door type, accuracy class-1.0, suitable for installation on structures for metering and protection with required CT ratio - 11 Set vi. Potential transformers, 33 kV /110V, outdoor type, oil immersed, burden 100 VA,33/√ 3 kV/ 110/ √ 3 V for metering and protection each for three phase system suitable for installation on structures for metering and protection - 4 Set. vii. Vacuum Circuit Breaker, 33kV,1250A, outdoor type, 25 kA with remote control panel having IDMTL relay for O/L and E/F protection, ammeter,energymeter as per specification-11 Nos. viii. Transformer, outdoor type, 16 MVA, 3 Phase, 50 Hz, Primary Voltage: 33000 V Secondary Voltage: 11000 V, Connection: DYn11-2 Nos.
ix.Transformer, outdoor type, 7.5 MVA, 3 Phase, 50 Hz, Primary Voltage: 33000 V Secondary Voltage: 3300 V, Connection: DYn11-2 Nos.
x. 33 kV/0.230 kV(L-L), 100 kVA, Outdoor, lighting transformer ,50 Hz, DY11- 1No. xi. 33 kV/0.415 kV, 160 kVA, outdoor, station transformer (Cu)-1 No. | 1 | Lot | 7,18,21,643 ₹7,18,21,643 | 6,10,17,400 ₹6,10,17,400 | 4,00,00,000 ₹4,00,00,000 Lowest | 7,62,83,748 ₹7,62,83,748 | 4,00,00,000 ₹4,00,00,000 Lowest |
Tender Value
₹24.6 Cr
EMD Value
₹30.8 L
Closing Date
25 Jul 2024, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GM EnM HOD Div I
Office of the GM EnM , EnM Department, Alakhnanda Building, CCL HQ, Darbhanga House, Ranchi, Jharkhand 834001
Planning, Design, Engineering, Construction, Fabrication, Erection, Supply, Installation, Testing and Commissioning of 33 KV Sub-Station at Giddi Washery Argada Area alongwith Operation and Maintenance of substation (plant) for five years
2024_CCL_310744_1
GM(ENM)/E-TENDER/24/837 DATED 18.06.2024
Open Tender
Electrical and Maintenance Works
Item Rate
2095 days
GIDDI Washery of CCL Dist Hazaribagh
Refer Tender Documents
7 documents required · 7 mandatory
₹30.8 L
27 Dec 2024
18 Jun 2024
26 Jul 2024
19 Jun 2024
25 Jul 2024
20 Jun 2024
19 Jun 2024 - 18 Jul 2024
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1A. WORK & SERVICES | |||||
| 1.01 | a.) Detailed survey of the area, within the battery limits & submission of reports (Complete work as per Tender document) b.) Sub soil exploration, field and laboratory testing of samples & submission of reports (Complete work as per Tender document) | 1 | LS | - | - |
| 2B. DESIGN & ENGINEERING COST | |||||
| 2.01 | a). Preparation and submission of system engineering drawings as per system requirements
b). GA & detail engineering designs and drawings of all civil and structurals included in the system and scope of works (Complete details of the system) c). G.A. & detailed engineering designs and drawings including working and maintenance manuals of (Complete details of the system) :
i) all individual equipment ( Electricals)
ii) Fire-Fighting System
iii) Earthing system & Lightening protection system
iv) Cabling System
v) Illumination system & Elerical Wiring Drawing of sub-station building
vi) Single Line Diagram & GA Drawing of the switchyard
vii)Any other system/unit to match the scope of work & requirement
d).Documentation as per tender specification, complete as per scope of works | 1 | LS | - | - |
| 3C. CIVIL & STRUCTURAL WORKS | |||||
| 3.01 | a). Earthwork in cutting in all types of soil and rock b). Earthwork in filling c). Sand filling d). PCC (M 10 and higer grade) at all levels as per system requirement e). RCC (excluding reinforcement) at all levels as per system requirement (M20 grade and above) including shuttering f). Supply, bending, binding and placing of Tor steel in position g).Supply, fabrication and erection of structural steel at all levels as per system requirement
h). Masonary work i) Pavement in substation | 1 | LS | - | - |
| 3.02 | Developmental work and infra-structure as per tender document | - | - | - | - |
| 3.021 | a). Site development:- earthwork in excavation and banking for leveling & dressing
b). Gravel packing in switchyard and Dyke Wall c). Roads and Culverts and Pathways d). Water supply for industrial, drinking and firefighting puposes including provision for deep bore-well, pipelines, ground water tank, pumps & pump houses with all electricals.
e). Dwarf Wall f). Substation building g).Security Post h). Drainage arrangement i). Boundary wall, Fencing with barbed wire & gates J). Cable Trenches k). Lighting and Lightning Towers l). RCC foundation for Steel Structures and transformers in outer switchyard m). PCC foundation for Lightening and lighting towers n).Retaining wall o).Chain linked fencing & Gate p). Anti-weed treatment q). Soak Pit for transformers r). Sewerage
s). DG Shed
t). Parking Shed
u). Pump House v). Miscellaneous | 1 | LS | - | - |
| 4D. PLANT & MACHINERY ( SUPPLY) | |||||
| 4.01 | 33 kV side comprising of following:
i. Isolators, 33 kV (nominal),3 poles, pole mounted, 1250A,25kA,
arrangement for interlocking with 33 kV Vacuum Circuit breaker- 10 Set ii. Isolators, 33 kV (nominal), 3 poles, pole mounted, 1250A,25kA, arrangement for interlocking with 33 kV Vacuum Circuit breaker with Earthing switch -08 Set.
iii. Isolators, 33 kV (nominal), 3 poles, pole mounted, 1250A,25kA, with D.O. Fuses. -06 Set. iv. Lightning Arrestors, station class, 30 kV,10 kA, suitable for 33kV, solidly earthed (each set consists of 3 nos.) with counters/surge monitors -14 Set.
v. Current transformers,33 kV out door type, accuracy class-1.0, suitable for installation on structures for metering and protection with required CT ratio - 11 Set vi. Potential transformers, 33 kV /110V, outdoor type, oil immersed, burden 100 VA,33/√ 3 kV/ 110/ √ 3 V for metering and protection each for three phase system suitable for installation on structures for metering and protection - 4 Set. vii. Vacuum Circuit Breaker, 33kV,1250A, outdoor type, 25 kA with remote control panel having IDMTL relay for O/L and E/F protection, ammeter,energymeter as per specification-11 Nos. viii. Transformer, outdoor type, 16 MVA, 3 Phase, 50 Hz, Primary Voltage: 33000 V Secondary Voltage: 11000 V, Connection: DYn11-2 Nos.
ix.Transformer, outdoor type, 7.5 MVA, 3 Phase, 50 Hz, Primary Voltage: 33000 V Secondary Voltage: 3300 V, Connection: DYn11-2 Nos.
x. 33 kV/0.230 kV(L-L), 100 kVA, Outdoor, lighting transformer ,50 Hz, DY11- 1No. xi. 33 kV/0.415 kV, 160 kVA, outdoor, station transformer (Cu)-1 No. | 1 | Lot | - | - |
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.06 MB
Tendernotice_2.pdf
Tender Document • 3.73 MB
Tendernotice_1.pdf
Tender Document • 3.09 MB
TIMEEXTENSIONSSGDW.pdf
Tender Document • 0.18 MB
BOQ_321991.xls
BOQ • 0.35 MB
146419572.html
Tender Document • 0.06 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .