Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.0 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹65.0 L+₹14.8 L (29.6%)Rejected-Finance | L2 | Rejected-Finance Not the lowest bidder |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
27 Apr 2020, 6:00 pmClosed
GE Barrackpore
Office of the Garrison Engineer Barrackpore, Kolkata-700120
SPECIAL REPAIRS TO BLDG NO.4 HSOI OLD BLDG RIVER SIDE AT BARRACKPORE UNDER GE BARRACKPORE
2020_MES_329098_1
8389/E8
Open Tender
Civil Works
Item Rate
180 days
Barrackpore
Refer to tender documents
2 documents required · 2 mandatory
₹500
GE Barrackpore
₹96,000
Yes
18 May 2020
27 Feb 2020
29 Apr 2020
27 Feb 2020
27 Apr 2020
14 Apr 2020
Amount
Taking down chowkats with shutters (without taking off shutter from the frames) not exceeding 1.50 Sqm each all as specified and directed.
Taking down chowkats with shutters (without taking off shutter from the frames) exceeding 1.50 Sqm and not exceeding 4.00 Sqm each complete all as specified and directed.
Taking down of shutters of any description exceeding 1 Sqm but not exceeding 2 Sqm and refixing in same opening after easing and adjusting all as specified and directed.
S&F for first class hard wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered put together with glue pinned at joints of second class hard wood etc complete all as specified and directed.
M&L for second class hard wood clean swan 35mmX10mm laths (fixed straight or diagonally) in two way trellis (jafri) work with 50mm spaces in the clear, including 75mmX50mm fillet (notched to take ends of laths) all-round and fixed complete all as specified and directed.
M&L for 30mm thick first class hard wood framed louvred shutters (factory made) with stiles and rails 100mm to 120mm wide and panels filled with fixed louvres from 10mm to 15mm thick, supplied and fitted to frames complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint over and including a coat of red oxide primer after preparation of new steel surfaces of any description over 10cm width or girth including necessary scaffolding as required at site due to building height 5mtr to 6 mtr complete all as specified and directed.
M&L for mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or forged into spikes; framed guard bars; barred iron doors; ladders, railings, framed brackets, walk ways, frame work of water tank and similar work conforming to Fe-290-0 Gde-E-165 complete all as specified and directed.
S&F for 35mm thick (factory made) plain, first class hard wood, framed, panelled shutters (three panels) with lock rails and panel of timber panels are raised and have bevelled or chamfered margins (for each side), the size of rail and stile as per IS-1003 (Part-I) (larger size to be provided) klin seasoned and chemically pressure treated fitted to chowkats complete all as specified and directed.
S&F for 35mm thick first class hard wood glazed/ gauge & skeleton shutters (factory made), open rebated & prepared to receive glass, gauge etc. (with sash bars) edges of framing plain, chamfered or rounded, fitted with cut & mitered beads for securing glass etc. sizes of members of shutters as specified in SSR part-I, section-8, clause 8.24 (a) (larger size to be provided) complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint over a coat of pink primer after preparation of new wooden surfaces of any description over 10 cm girth or width complete all as specified and directed.
M&L for applying one coat of synthetic enamel paint after preparation of old painted wooden surfaces of any description, not otherwise described, over 10cm in width or girth complete all as specified and directed.
M&L for applying one coat of synthetic enamel paint after preparation of old painted steel surfaces of any description, over 10cm in width or girth, not otherwise described including necessary scaffolding as required on site due to building height 5mtr to 6 mtr complete all as specified and directed.
M&L for applying french polishing on surfaces of any description, any width or girth and preparing the surface including a coat of wood filler on old works with two or more coats after removing old paint by paint remover or burnning off by blow lamp and cleaning with scrapping any number of coats complete all specified and directed.
M&L for applying french polishing on surfaces of any description, width or girth including cleaning and preparing the surface including a coat of wood filler on new works with two or more coats complete all specified and directed.
M&L for applying french polishing on surfaces of any description, width or girth including cleaning and preparing the surface including a coat of wood filler on old works with one or more coats complete all specified and directed.
S&F for stainless steel wire cloth, 0.56 mm nominal dia of wire & average width of aperture 1.18mm & fixed with tinned tacks or galvanised wire staple complete all as specified and directed.
S&F for stainless steel wire cloth, 0.36 mm nominal dia of wire & average width of aperture 1.40mm & fixed with stainless steel wire staple complete all as specified and directed.
S&F for 5.5mm thick sheet glass panes, ordinary quality and glazing with oil putty or fixed with bead/glazing pins in squares not exceeding 0.50 sqm each pane complete all as specified and directed.
S&F for 3.0mm thick sheet glass ordinary quality and glazing with oil putty or fixed with bead/glazing pins in squares not exceeding 0.50 sqm each pane complete all as specified and directed.
S&F for 3.0mm thick frosted sheet glass ordinary quality and glazing with oil putty or fixed with bead/glazing pins in squares not exceeding 0.50 sqm each pane complete all as specified and directed.
S&F for 100 mm long cast brass, with mild steel hinge pin, bright polished and fixed, type B-11, medium weight complete all as specified and directed.
S&F for 300 mm brass , sliding door bolt with sand or die cast brass hasp and staple (bolt type ) and fixing clips of sheet and fixing bolts and sliding bolts fixed complete all as specified and directed.
S&F for 450mm long brass skeleton tower bolt with cast brass plate and staple and rolled or drawn brass bolt and fixed complete all as specified and directed.
S&F for 150 mm size extruded brass handle, fabricated type, polished complete all as specified and directed.
S&F for 300mm long, brass ordinary rat tail rod pattern spring including roller & roller plate complete all as specified and directed.
S&F for floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring, fixed in floor (overall length of cover plate 150mm) complete all as specified and directed.
S&F for peg set of six, brass fixed with chromium plated/ brass screws and wooden and plastic cleats (minimum weight 190 gms) complete all as specified and approved by GE
S&F for 25mm dia (heavy duty) mild steel, powder coated (wood colour finished), single curtain rod (wall thickness not less than 1mm) funnels etc complete as in repair all as specified and as directed.
Demolition of brick work built in cement mortar etc complete all as specified and directed.
M&L for brick work with sub class 'B' bricks straight or curved on plan exceeding 6m mean radius, built in cement mortar (1:6) complete all as specified and directed.
Taking down cement plaster of any description on brick or stone or concrete surface of wall etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar (1:6) on brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 5mm thick in cement mortar (1:3) on ceiling surfaces, finished fair and even complete all as specified and directed
M&L for rendering 20 mm thick, 1st coat 10mm thick in cement mortar (1:4) & 2nd coat 10mm thick in cement mortar (1:4) with water proofing compound @ 2% by weight of cement and Recron-3S micro fibres (6mm-18mm length) used @0.25% by weight of cement, plastered surface shall be finished even and smooth without using extra cement complete all as specified and directed. (Note : WPC and Recron-3S micro fibre shall be measured and paid separately, WPC and Recron-3S micro fibre shall be used in second coat only)
Supply only Recron- 3S Micro Fibers (6 -18mm length) all as specified and directed.
M&L for rendering 10mm thick in cement mortar (1:3) on facia/ edging/ceiling of chajja, roof projections etc surface finished even and smooth finish on plastered surface without using extra cement including taking out peeled off plaster/concrete and making the line true shape complete all as specified and directed.
Supply only integral water proofing compound, ISI marked complete all as specified and directed.
M&L for applying two coats of cement based paint over a coat of alkali resistance primer on newly plastered surface of walls including preparation of surface complete all as specified and directed.
M&L for applying two coats of cement based paint over a coat of alkali resistant primer on old plastered surface of walls after complete removal of existing treatment complete all as specified and directed.
M&L for applying two coats of distemper oil emulsion over a coat of alkali resistant primer over and including applying 3 mm thick wall care putty after preparation of newly plastered surfaces of walls complete all as specified and directed.
M&L for applying two coats of oil emulsion distemper over a coat of alkali resistant primer over and including applying 3mm thick wall putty on old decorated plastered surface of ceiling after complete removal of existing treatment including preparation of surfaces complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floor and paving not exceeding 15 cm thickness (below or above ground level) all as specified and directed.
M&L for 75mm thick PCC (1:3:6) type C1 (using 20mm graded crushed stone aggregate) as in plinth protection/paving including finishing the cement concrete surface even and smooth without using extra cement in slope including making joints of every 2.5m and at corner filled with bitumen 85/25 and sand in ratio (1:2) by weight and complete all as specified and directed.
M&L for PCC (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) as in surface channel and drains etc complete all as specified and directed.
M&L extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/ stopped ends etc complete all as specified and directed.
M&L for 75mm thick PCC (1:4:8) type D-2 (using 40 mm graded stone aggregate) as in subbase to floor complete all as specified and directed.
M&L for pre-polished coloured chequered cement concrete tiles 300mm x300mm x 25mm thick (glossy type), set, jointed and pointed in neat cement slurry in floors with grey cement and pigments over and including 15 mm thick cement screed bed in cement mortar (1:6) complete all as specified and directed.
M&L for providing, cement concrete (1:2:4) type B-0 (using 12.5mm graded crushed stone aggregate) as in benching complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M&L for 20 mm thick Makrana Marble slab (white) machine cut, in floor etc bedded and jointed (joint free) with white cement slurry and pointed with white cement with admixture of pigment to match the of marble stone including grinding and polishing over and including 20mm thick screed bed of cement mortar (1:6) complete all as specified and directed.
M&L for 20mm thick Makrana Marble slab (white) machine cut, in wall/skirting/dado laid over cement screed and jointed (joint free) with white cement slurry, and pointed with white cement with admixture of pigment to match the shade of marble stone including grinding and polishing over and including a backing coat of 10 mm thick bedding in cement mortar (1:4) complete all as specified and directed.
M&L for non skid (joint free) ceramic coloured (colour & shade as approved by GE) tiles of 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc set and jointed in neat cement slurry and pointed in colour cement to match over and including 15mm thick Screed bed or beading layer of cement mortar (1:4) for laying floor finishes complete all as specified and directed.
M&L for glazed ceramic coloured tiles (colour & shade as approved by GE) in vertical surface of size 450mmX 350mmX7 to 8mm thick set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10 mm thick screed bed of cement mortar (1:4) complete all as specified and directed.
M&L for 20mm thick granite (any type) work (table rubbed and polished) machine cut in steps (riser), jambs, pillars, window cill, cooking platform etc bedded and jointed with grey cement slurry and pointed with white cement (1:2) using marble dust with admixture of pigment to match the granite stone including and polishing over and including 15mm thick cement mortar (1:4) complete all as specified and directed.
Round chamfering, splays or arris to the edges of granite not exceeding 15mm wide on granite stone shelves complete all as specified and directed.
Demolition of reinforcement cement concrete of any description and in any position not otherwise specially provided for complete all as specified and directed.
M&L for cutting chases, in brick wall and making good to facing where required and pointing in cement mortar (1:3), to ends or edges of landing, steps, cills, sunshades, shelves, lintels etc and cutting chases for concealed water tubing or concealed conduit wiring etc and making good, cutting exceeding 10 cm but not exceeding 20cm girth complete all as specified and directed.
M&L for formwork to the soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exceeding 200 mm thick (horizontal or sloping ) and making flat, rough finished surfaces of concrete complete all as specified and directed.
M&L for providing precast cement concrete (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) set in cement mortar (1:4) in window or door cills, lintels, buessumers, steps, quion block (for use with masnory), string courses, coping, kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, bonders (for stone wallin) corbels, brackets etc (of any section indicated) with plain fair faces including chamfers, weatherings, throating etc and setting in mortar complete with joints to match all as specified and directed.
M&L for precast reinforced cement concrete (1:2:4) type B1 (using 20 mm graded crushed stone aggregate) as in cover slab of drain/manhole, chullah hoods, shelves, chajja, landing, water tank/shelf etc set in cement mortar (1:4) complete all as specified and directed. (NOTE: Cost of form Work is deemed to be inclusive of unit rate quoted by the contractor & reinforcement shall be measured & paid Separately.)
M&L for TMT bars 6mm to 8mm cut to length bent to shape as required including cranking, bending spirally for hoping for columns, hooping ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete for stirrups all as specified and directed.
M&L for TMT bars 10 mm dia and over cut to length bent to shape as required including cranking, bending spirally for hoping for columns, hooping ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description etc complete all as directed.
S&F for joist, channel, flat iron, angle or tee sections, fixed independently, without connecting plates etc (cut to ordinary lengths i.e. within 20mm of the length indicated) of Fe 410-W (Gde E-250) quality A all as specified and directed.
S&F for rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates including where required drilling, fittings, riveting or welding connecting with fish plate, gusset plates etc of Fe-410-W (Gde E-250) quality 'A' complete all as specified and directed.
S&F for mild steel flat iron as in wind tie including all necessary drilling, bolting or riveting etc and similar work complete conforming to Fe-290 Gde E-165 complete all as specified and directed.
Dismantling of asbestos cement (corrugated, semi-corrugated etc.) sheets in roof coverings complete all as specified and directed.
S&F for pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet of 0.50mm thick of any colour as approved by GE having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F for pre-painted galvalume aluminium zinc coating GI based plain steel sheet of 0.50mm thick of any colour as approved by GE having tensile strength of 550 Mpa as in ridge to wall/cladding, fixed with self tapping screws complete all as specified and directed.
Taking up or down steel tubings & connections including cleaning for refixing or removal from site for 15 mm bore pipes all as specified and as directed.
Refixing old steel tubings & connections in new or old position (wall, ceiling, floor etc.) for 15mm bore pipes with new fittings etc complete all as specified and as directed. (Note : Pipe shall be obtained from Item No 71.00 above)
S&F for 15mm dia tubes (medium grade) galvanised, with all fittings and fixed complete to walls and ceilings or laid in floors, wall etc complete all as specified and directed.
Taking up or down steel tubings & connections including cleaning for refixing or removal from site for 20 mm bore pipes all as specified and as directed.
Refixing old steel tubings & connections in new or old position (wall, ceiling, floor etc.) for 20mm bore pipes with new fittings etc complete all as specified and as directed. (Note : Pipe shall be obtained from Item No 74.00 above)
S&F for 20mm dia tubes (medium grade) galvanised, with all fittings and fixed complete to walls and ceilings or laid in floors, wall etc complete all as specified and directed.
M&L for cutting chases, in brick wall and making good to facing where required and pointing in cement mortar (1:3), to ends or edges of landing, steps, cills, sunshades, shelves, lintels etc and cutting chases for concealed water tubing or concealed conduit wiring etc and making good, cutting not exceeding 10cm girth complete all as specified and directed.
S&F for 15 mm dia angular stop valve cast copper alloy, chromium plated, fancy type, screwed down high pressure with wall flange complete as in repairs all as specified and directed . (Make: Jaquar Cat No.FLR-5053N or equivalent of Marc/Kohler as approved)
S&F for 15mm dia bib taps, cast copper alloy, fancy type, chromium plated with flange complete as in repairs all as specified and directed. (Make: Jaquar Cat No.FLR-5047N or equivalent of Marc/Kohler as approved)
S&F for 15mm dia bib taps, two way, cast copper alloy fancy type with chromium plated with flange complete as in repairs all as specified and directed. (Make: Jaquar Cat No.FLR-5041N or equivalent of Marc/Kohler as approved)
S&F for vitreous china wash basin, full pedestal with wall hung, white, flat back, size 560mm X 470mmX190mm, excluding taps, chain and plug and porcelain stopper but including waste pipe, waste coupling (CP) 32mm dia full threaded brackets and cutting for and pinning in ends of brackets or erecting stand complete as in repair all as specified and directed. (Make: Jaquar Cat No.ARS-WHT-39801 or equivalent of Marc/Kohler as approved)
S&F for single lever fancy type chromium plated wash basin mixer for mixing hot & cold water without popup waste with 450mm long braided hoses including necessary connection pipe from stop cock complete as in repair all as specified and directed. (Make: Jaquar Cat No.KUP-3501BPM or equivalent of Marc/Kohler as approved)
S&F for towel ring round complete in repairs all as specified and directed. (Make: Jaquar Cat No.AQN-7721 or equivalent of Marc/Kohler as approved)
S&F for soap dish, chromium plated complete as in repair all as specified and directed. (Make: Jaquar Cat No.AQN-7733 or equivalent of Marc/Kohler as approved)
S&F for chromium plated toilet paper holder with stainless steel flap fixed to walls with chromium plated brass screw complete as in repairs all as specified and directed. (Make: Jaquar Cat No.AKP-35753PS or equivalent of Marc/Kohler as approved)
S&F for glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 55cm long complete as in repair and all as specified and directed. (Make: Jaquar Cat No.AQN-7771 or equivalent of Marc/Kohler as approved)
S&F for vitreous china wash down water closet pan (pedestal pattern) white with P or S trap (excluding flushing cistern & flush pipe) including connection to trap & to flushing pipe, anti-syphonage pipe & seat cover etc. complete as in repair including making good to floor all as specified and directed.
S&F for vitreous china wash down water closet pan, floor mounted coupled white with P or S trap (excluding flushing cistern & flush pipe) including connection to trap & to flushing pipe, anti-syphonage pipe & PP soft seat cover etc. complete as in repair including making good to floor complete all as specified and directed. (Make: Jaquar Cat No.ARS-WHT-39751P or equivalent of Marc/Kohler as approved)
S&F for jet spray (with 1.50m tube) fixed with EWC and angular stop cock complete as in repair all as specified and directed. (Make: Jaquar/Marc/Kohler as approved)
S&F for 125mm long health faucet (ABS) with rubbit cleaning system, one meter long PVC flexible tube for 15mm dia and ABS wall hook complete as in repair all as specified and directed. (Make: Jaquar/Marc/Kohler as approved)
S&F for 10 Ltrs capacity, PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete with all internal accessories and fixed to wall and jam nuts on both sides, PVC flush pipe 32mm dia 90cm long fixed properly to inlet of WC and making good to disturbed surfaces of wall or floor complete as in repair all as specified and directed.
S&F for vitreous china urinals, half stall type, fixed in repair including waste coupling 32mm size full thread, brass, chromium plated, waste pipe and all necessary fittings including dismantling old urinal bowl etc complete all as specified and directed. (Make: Jaquar Cat No.URS-132530 or equivalent of Marc/Kohler as approved)
S&F for PVC connection pipe 15 mm size with PTMT nuts of length 450 mm complete as in repair all as specified and as directed.
Disconnecting existing tanks of (exceeding 500 & not exceeding 1000 litres in capacity), setting aside (or lowering if required) and cleaning, removing all scale and dirt etc from tanks and mouth of pipe including hoisting (if required) reconnecting and refixing in positing all as specified and as directed. (NOTE: Date of cleaning must be written at side of water tank with white paints after cleaning of tank)
S&F for 1000 Ltr capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) multi layer (three layer) hoisted and fixed in position with cover of tank with its locking arrangement, making hole for inlet, outlet and overflow connection including dismantling / taking down old PVC water tank, ball valve etc complete all as specified in SSR Part-I all as specified and directed.
S&F for 500 Ltr capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) multi layer (three layer) hoisted and fixed in position with cover of tank with its locking arrangement, making hole for inlet, outlet and overflow connection including dismantling / taking down old PVC water tank, ball valve etc complete all as specified in SSR Part-I all as specified and directed.
S&F for 20mm dia gun metal gate valves with iron wheel head screwed both ends for iron pipes or for unions pipes, fixed as in repairs all as specified and directed.
S&F for sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or in and including fixing cantilever brackets, 32mm dia full threaded waste coupling and connecting union to pipe overall size 495mm x 420mm, bowl size 410mm x 330mm x 160mm complete as in repair all as specified and directed.
S&F for 100mm bore sand cast iron soil, waste and vent pipes in any length with or without ears with cement joints, fixed in trenches complete as in repair all as specified and directed.
S&F for 100mm bore sand cast iron soil, waste and vent pipes in any length with or without ears with cement joints, fixed in wall with clamps and cement joints complete as in repair all as specified and directed.
S&F for 100 mm dia cast Iron bends (any radius) diminishing piece or tapers (larger bore measured) fixed with oval access door complete as in repair all as specified and directed.
S&F for 100mm dia CI branch pieces, double (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches complete as in repair all as specified and directed.
S&F for 100mm dia CI branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches complete as in repair all as specified and directed.
S&F for 75 mm bore sand cast iron soil, waste and vent pipes in any length with or without ears with cement joints, laid in floor complete as in repair all as specified and directed.
S&F for 75 mm bore sand cast iron soil, waste and vent pipes in any length with or without ears with cement joints, fixed in wall with clamps complete as in repair all as specified and directed.
S&F for 50 mm bore sand cast iron soil, waste and vent pipes in any length with or without ears with cement joints, fixed in wall with clamps complete as in repair all as specified and directed.
S&F for 75 mm dia cast Iron bends (any radius) diminishing piece or tapers (larger bore measured) complete as in repair all as specified and directed.
S&F for 75mm dia CI branch pieces, double (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches with oval acess doors complete as in repair all as specified and directed.
M&L for 100mm dia cast iron floor trap with CP grating with or wihtout hole including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete as in repair all as specified and directed.
M&L for 75mm dia cast iron floor trap with ith CP grating with or without hole including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete as in repair all as specified and directed.
S&F for 100 mm cast iron cowls complete as in repairs all as specified and directed.
M&L for cast iron swan neck (of offsets) upto 152 mm projection for 100mm to 50 mm pipe complete all as specified and directed.
S&F for salt glazed stone ware gully trap of size 150mmX150mm square or round moulded type 'P' complete all as specified and directed.
Cutting channels, grooves or rebates of 50mm wide and girth not exceeding 15 cm and trimming surface in old brick masonary or concrete complete all as specified and directed.
Dismantling timber scantlings (un-framed work) 40 sq.cm and over in section, in any position complete all as specified and directed. Note: (i) The supports for roof before removing the old wooden/rusted iron beams shall be properly disignated and put in place before removing the old beams and replacing it with new beam. (ii) The temporary supports during replacement of beams and other components shall consist of tubular steel props minimum 65mm dia /jack and polly system of desire strength and placed at proper spacing and braced for shoring/support of existing structure during execution of work. (iii) The rate quoted for this item shall be inclusive of the charges for temporary support of above, props and necessary scaffolding arrangement as required on site. The system provided which shall be recoved after placing new beam in position.
Dismantling of structural steel work of any description excluding framed trusses and re-erecting in same position after necessary repairs works as directed by Engr-in-Charge complete all as specified and directed. Note: (i) The scope of this item involves taking down of existing old steel beam/wooden beam, repairing the bearing of the beam as directed re-erecting the repaired beam in same position. The supports for roof/floor before removing the old rusted iron beam/wooden beams shall be properly designed and put in place before recoving the old beams and replacing it with repaired beam. (ii) The temporary supports during replacement of beams and other components shall consist of tubular steel props minimum 65mm dia/jack and polly system of desire strength and placed at proper spacing and braced for shoring/support of existing structure during execution of work. (iii) The rate quoted for this item shall be inclusive of the charges for temporary support of above, props and necessary scaffolding arrangement as required on site. The system provided which shall be removed after placing repaired beam in position. The new parts welded to ld beam for strengthening and the welding shall be measured and paid separately.
S&F for rolled mild steel, ISMB, joist, channel, angle, tee section, flat, hollow tubular section etc fixed independently with or without connecting plates etc upto height of 5 to 6 mtr from each floor level (cut to ordinary length i.e. within 20mm of the length indicated) Grade E-250 (Fe-410W) complete all as specified and directed. Note: (i) The sections to be provided under this item will be used as beams to support floors/roofs after removing the existing wooden/rusted iron beams. (ii) Welding wherever required for strengthing of existing girders/other sections etc deemed to be included under this item. (iii) The rate quoted for this item shall be inclusive of the charges for support system provided and necessary concrete work required for fixing of girder/other sections etc and necessary scaffolding arrangement/support as required on site complete all as specified and directed by Engr-in-Charge.
Racking out joints on existing roof or terracing tiles of size 0.04 Sqm to 0.16 Sqm and cleaning out joint with wire brushes and filling the joint solidly with hot mixture of bitumen and clean dry sand in (1:1) complete all as specified and directed.
M&L for wire brushing and cleaning top surface of tiles, lime terracing or cement concrete including flashings and junction of parapets etc and surface painting with one layer of blown bitumen of any penetration applied hot @ 1.7 Kg per Sqm and lightly tampered (area of flashing etc shall be added to the roof area) complete all as specified and directed.
Dismantling of mangalore pattern roofing/ceiling tiles with ceiling tiles or slate roofing complete all as specified and directed.
S&F for 30mm thick sand stone slab including 25 mm thick cement concrete (1:2:4) type B-0 (using 12.5mm graded crshed stone aggregate) set and jointed over steel members with necessary support from ground level if required for fixing of the sand stone slab joists etc complete all as specified and directed.
M&L for running welding and thickness of metal to be welded not exceeding 6mm and complete all as specified and directed.
Demolition of cement concrete (un-reinforced) as in roofs, floors (other than ground floors), beams, stair cases, landing, chajjas and similar suspended work all as specified and directed.
M&L for PCC (1:2:4) type B-0 (using 12.5mm graded crushed stone aggregate) averaging 40mm thick as in roof padding / levelling course, surface finished even and smooth without using extra cement complete all as specified and directed.
M&L for 15mm thick rendering in cement mortar (1:4) mixed with water proofing compound on walls and roof surfaces finished even and smooth using extra cement all as specified & directed. (Note : WPC shall be mixed @ 2% by weight of cement or as recommended by manufacturer and the same shall be measured and paid separately)
M&L for applying evenly a coat of bitumen primer on roof, canopy, chajja, parapet (vertical surface etc) @ 0.40 Litre / Per Sqm by the same membrane manufacturer of density 250C, 0.87 to 0.89 litre and viscosity 70-160 cps after proper cleaning the roof surfaces (horizontal/vertical) and providing APP based polymeric membrane minimum weighing 3.6 Kg/Sqm and minimum 3mm thick reinforced with polyester non wove fabric (weight not less than 150 gms / sqm) laid on primed surface with side over lap of 80 mm and end overlap of 100 mm, using bitumen torch or by LP gas torching and sealing all joints etc and ensuring complete thermo fusing and applying one coat of aluminum paint over it complete all as per manufacturer instructions complete all as specified and directed.
S&F for fancy type wooden bracket of best quality as approved by GE suitable for curtain rod complete as in repair all as specified and directed.
Taking down carefully copper/aluminium point wiring (light, fan, bell, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, holders, regulators, sockets, tube light fittings and including making good the disturbed surfaces to match with the existing surfaces and applying white/ colour wash/distemper after applying putty for smooth finish surface complete all as specified and directed.
M&L for point wiring complete with 1.5 sqmm PVC insulated, FR-LSH type, ISI marked,conforming to IS-694/1990 unsheathed, multistranded, single core, copper conductor cable 1100 volts grade colour code cables drawn through and including PVC Conduit 20 mm dia medium grade (MMS) and including cutting, chasing work at any height and all accessories concealed in walls / roofs / floors / ceiling etc. flush mounting MS box with top, bottom, side/back wall knockout for conduit entry from any direction made out of 1.60mm thick suitable for fixing of modular top cover , blanking plate as per numbers of switch modules, modular switches, sockets, fan regulators, red colour indicator, blank plates etc as approved coloures modular accessories of suitable modules and including 1.5 Sqmm PVC insulated multistranded FR-LSH type unsheathed (Green colour), single core cable with copper conductor cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour coat including providing putty and white cement for smooth finishing of existing surface complete all as specified and directed for the following:- (Note:- All necessary accessories such as modular box, top cover plate, blank plate, MS box, screws, washers and all modular electrical fixtures are to be used same make/brand only and shall be deemed in to included in quoted rate only.)
One light point controlled by one switch .
One fan point controlled by one switch and one regulator.
One fan point controlled by one switch.
One 5 pin 6 amps socket point controlled by one 6 amps switch on independent board .
One 5 pin 6 amps socket point controlled by one 6 amps switch on same board .
All as per Item No.130.00 here-in-before but point wiring with 2.5 sqmm PVC insulated multistranded flexible unsheathed copper conductor FR-LSH and earth conductor of size 2.50 sqmm PVC insulated multistranded flexible copper conductor FR-LSH complete all as specified and directed for following:- .
One 6 pin 6/16 amps socket outlet point controlled by one 16 amps switch on independent board.
One 6 pin 6/16 amps socket point controlled by one 16 amps switch on same board .
All as per Item No.130.00 here-in-before but point wiring with 4.0sqmm PVC insulated multistranded flexible unsheathed copper conductor FR-LSH and earth conductor of size 4.0 sqmm PVC insulated multistranded flexible copper conductor FR-LSH of one 3 pin socket outlet point controlled by one 16 Amps switch on independent board complete all as specified and directed .
S&F for modular type switch 10 Amps, single pole, 1 way, 1/2 module, 240V, AC, ISI Marked complete all as specified and directed.
S&F for modular type switch 16 Amps, single pole, 1way, 1/2 module, 240V, AC, ISI marked complete all as specified and directed.
S&F for modular type socket shuttered type 6 Amps, 2/3 pin combined 2 module, 240 V, AC, ISI marked complete all as specified and directed.
S&F for modular type socket 6/16 Amps, 6 pin combined shutter socket, 2/3 module with light indication, 240 V, AC, ISI marked complete all as specified and directed.
S&F for red colour lighting indication lamp 6 Amps, single pole, 240volts, AC, 50 Hz suitable for 1/2 module ISI Marked complete all as specified and directed.
S&F for fan regulator, modular type electronic, stepped type (01 to 4/5), 100 to 120 Watts, 240Volts, AC, ISI marked complete all as specified and directed.
S&F for angle lamp holder, insulated body with back plate for batten fittings including LED lamp 12 watts complete all as specified and directed.
S&F for ceiling rose, 3 terminal, surface bakelite 65X50mm, ISI marked PVC/polycarbonate body complete all as specified and directed.
S&F for decorative box type 20 watt/22 watt LED fitting of fire retardant engineering grade complete with all accessories internally pre-wired, connecting up with and including three core sheathed flexible conductor cable of 0.50 Sqmm size and including mounted on PVC/Wooden round/square blocks-02 Nos including removing old unserviceable light fittings complete all as specified and directed. (Make - Havells Cat No REGALBATTENT8UPTO1 x 22WDSBSWH/Crompton Greaves cat No : DMLN1LT8-16 as approved)
S&F for 20 watt linear LED T8 tubular lamp with extruded aluminium body and polycarbonate diffuser with inbuilt driver complete including taking down old unserviceable lamp complete all as specified and directed. (Make: Crompton Greaves Cat No LTT8-20-865-2 /Havells Cat No LUMILINEPLUSBS20WLED865SPCSS as approved)
S&F for decorative type surface mounted 1X6 watts LED light fitting with LED lamps including fixing arrangements at any height with nuts ,screws and washers and connected to ceiling rose and including removing old unserviceable fittings complete all as specified and directed. (Make: Crompton cat No.LCSR-06-CDL / Havells cat No EDGEPRORDDLR6WLED857S as approved)
S&F for recess mounting 2'x2' LED 36 Watt light fitting slimmest 9 mm thin in class LED ceiling panel with best in class aesthetic white powder coated frame blended seamlessly with ceiling layout suitable for 600X600mm modular ceiling grid and also can be suspended with provided kit and including connecting up with ceiling rose to fitting and including removing old unserviceable item complete all as specified and directed complete as in repair all as specified and directed, (Make: Crompton Cat No.LCPL-36-CD(2x2) / Havells Cat No. LHEWBPP6PW036 as approved )
S&F for 4 blades fan bulb 50 watt retrofit type inbuilt electronic driver, 240 Volts, 50 HZ and suitable for brass threaded holder heavy duty including hanging kit and including connecting up with ceiling rose to holder and including removing old unserviceable item complete all as specified and directed. (Make: Philips/Crompton Greaves/Havells as approved)
S&F for 3 blades fan bulb 36 watt retrofit type inbuilt electronic driver, 240 Volts, 50 HZ and suitable for brass threaded holder heavy duty including hanging kit and including connecting up with ceiling rose to holder and including removing old unserviceable item complete all as specified and directed. (Make: Philips/Crompton Greaves/Havells as approved)
S&F for powder coated sheet metal enclosure with metal type acrylic door, 415 volts, AC, VTPN DB (V-vertical type distribution board) 8 way plus 24 modules, for flush mounting with 200amps copper busbar, 2 neutral/earth bar for ease of installation and MCCB incomer of rating upto 200Amps, FP and MCB SP /TP MCB's as outgoing and complete connecting cable links with top and bottom with IP54 DBs protection and including making good the disturbed surfaces to match with existing surface and colour coat complete as in repair all as specified and as directed. (Make: Legrand cat No.5077 32, 8 way / Hager Cat No.VYVO8DM-P / L&T Cat No.DBVTH008GD as approved)
S&F powder coated sheet metal enclosure acrylic door 240 volts AC, SPN distribution board 8 way for flush mounting with 100amps copper busbar, neutral bar, earth bar and MCB incomer of rating upto 100Amps, MCB SPN/DP and MCB SP as outgoing and complete connecting cable links with top and bottom removable gland plate with IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface & colour coat complete as in repair and all as specified and directed. (Make: Legrand Cat No. 5076 21 8 way / Hager cat No.VYS08G / L&T Cat No.DBSPN008GD as approved)
S&F for powder coated sheet metal enclosure acrylic door 240 volts AC, SPN distribution board 4 way for flush mounting with 100 amps copper busbar, neutral bar, earth bar suitable for MCB incomer of rating upto 100 Amps, MCB SPN/DP and MCB SP, 10KA as outgoing and complete connecting cable links with top and bottom removable gland plates with IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface and colour coat complete all as specified and directed. (Make:- Legrand cat No. 5076 20 4 way / Hager cat No.VYS04G / L&T Cat No. DBSPN004GD as approved).
S&F for MCB, SP, 6 Amps to 32 Amps, 'C' series, 240 Volt, 10KA, 50 Hz, ISI marked complete all as specified and directed
S&F for MCB, SPN, 40 Amps to 63 Amps , 'C' series, 240 Volt, 10KA, 50 Hz, ISI marked complete all as specified and directed
S&F for on-load change over switch 160 Amps, four pole, 415 Volts, 50 Hz, open execution type, front handle operated and including providing out door sheet steel enclosure made out of 2.0mm thick CRCA sheet duly painted with powder coating in approved shade, rubber gasketed hinged door having front opening, locking arrangement and provision of bottom cable entry for incoming and outgoing cable with chromium plated brass cable glands and connecting up with suitable aluminium lugs and including MS angle iron 40mmX40mmX6mm with support at a height 1m with red oxide primer and two coats of synthetic enamel paint and embedded in floor with necessary PCC (1:2:4) type B1 (using 20mm graded aggregate) complete all as specified and directed. (Make:Legrand/Hager/L&T as approved)
M&L for sub main wiring complete with 2 run of 10 sqmm single core copper conductor (ISI marked) cable 1100 volts grade, FR-LSH type, PVC insulated, unsheathed, flexible, multi stranded colour coded cables drawn through and including rigid PVC conduit of size 25 mm dia medium grade (MMS) with all connected accessories such as Bend, Tee, Elbow, Short pieces etc concealed in wall/roofs/floors and including one run of 10 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, FR-LSH type as earth continuity conductor connected to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour coat and applying putty including cutting and cheasing after taking down old unseviceable submain wiring complete all as specified and directed. (Note : Two run of 10 sqmm single core copper conductor cable and one run of 10 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit)
M&L for sub main wiring complete with 2 run of 6 sqmm single core copper conductor (ISI marked) cable 1100 volts grade, FR-LSH type, PVC insulated, unsheathed, flexible, multi stranded colour coded cables drawn through and including rigid PVC conduit of size 25 mm dia medium grade (MMS) with all connected accessories such as Bend, Tee, Elbow, Short pieces etc concealed in wall/roofs/floors and including one run of 6 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, FR-LSH type as earth continuity conductor connected to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour coat and applying putty including cutting and cheasing after taking down old unserviceable submain wiring complete all as specified and directed . (Note : Two run of 6 sqmm single core copper conductor cable and one run of 6 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit)
M&L for sub main wiring complete with 2 run of 4 sqmm single core copper conductor (ISI marked) cable 1100 volts grade, FR-LSH type, PVC insulated, unsheathed, flexible, multi stranded colour coded cables drawn through and including rigid PVC conduit of size 25 mm dia medium grade (MMS) with all connected accessories such as Bend, Tee, Elbow, Short pieces etc concealed in wall/roofs/floors and including one run of 4 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, FR-LSH type as earth continuity conductor connected to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour coat and applying putty including cutting and cheasing after taking down old unserviceable submain wiring complete all as specified and directed . (Note : Two run of 4 sqmm single core copper conductor cable and one run of 4 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit)
S&F for sheet metal enclosure single pole and neutral with a two pin and earth plug and socket complete including one single pole, MCB 20 Amp, 240Volts, 'C' series, 10KA, ISI marked complete all as specified and directed.
S&F for MCCB, four Pole, 100 Amps, breaking capacity Icu at 415 AC, 50 HZ, 25 KA all as specified and as directed. (Make : Hager Cat No. HHA101Z/Legrand Cat No. 4200 15 as approved)
M&L for earthing complete with galvanised steel earth plate electrode of size 600mm x 600mm x 6mm thick buried directly in ground with earth pit not less than 2.25 meter deep below ground level with top edge of plate not less than 1.5 meter below normal ground level connected to galvanised steel earth strip of size 25 x 4mm earth lead by means of nuts, bolts, check nuts, washers of galvanised iron as steel, protected by galvanised iron pipe 40mm bore (Medium grade) all as directed including cement concrete (1:3:6) type C-1 earth pit with precast RCC (1:1.5:3) type A-1 cover slab of size 42 x 42 x10cm thick reinforced with 8mm dia TMT bars @ 15 cm c/c both ways with 10mm dia mild steel round bar of 30 cm long, bent to shape as lifting handle, funnel, wire mesh, 20 mm bore galvanized iron pipe (medium grade) for watering, charcoal or coke and salt in alternate layers with necessary earth work in soft/loose soil complete all as shown in electrical plate No 5 of SSR Part I including testing on completion all complete as specified and directed . (Galvanised strip upto 7.5m including testing consider in this item).
Taking down old unserviceable ceiling fan of any type/size from existing location and deposit in MES store yard and Supply and fix ceiling fan of size 1400 mm sweep,high speed, single phase, 240Volts, AC, 50Hz, as approved colour and including hanging GI hook with necessary suitable MS clamps and connecting cable three core 0.75 sqmm round PVC sheathed from ceiling rose to fan connector and testing complete all as specified and directed. (Make:- Standard -Model No .SAILOR /Usha model No :- Striker /Havells model No. ES-50 as approved)
S&F for metallic type exhaust fans AC single phase 230/240 V of size 300 mm sweep, 900 RPM with louver and necessary connection including cutting the existing wall surfaces of brick/stone masonry and making the hole of any height for fixing the exhaust fan with nuts, bolts and washers after grouting in PCC including mild steel jalli and wooden frame for avoid insects complete all as specified and directed. (Make : Havells model No Turbo Force SP 300mm-900RPM/Standard model No : 300mm-900RPM as approved)
S&F for water storage heater (geyser) of 25 ltrs capacity, vertical type with copper inner tank, 240 volts, AC, 50Hz and fixing arrangement on wall including providing hole fastners-04 nos,hot & cold water PVC pipes 15 mm bore approximate 600 mm long -2 Nos, chromium plated brass stop cock 15 mm bore -01 No and including necessary plumbing work, tesing and taking down existing old unserviceable geyser and depositing in MES Store yard all as spcified and directed. (Make: Havells/Crompton Greaves/Recold as approved)
M&L for GI pipe 50mm dia (light grade) laid on wall for fixing of ceiling fans with PCC embedded properly in wall surface with all fittings complete all as specified and directed.
Supply, fabricated and fixing of street light bracket made out of GI pipe 1.20 Mtr long, 40mm dia medium grade bent to shape as directed including clamps made out of 30 mm x 6 mm flat for fixing bracket suitable for steel tubular poles including nuts and bolts, washers and other connected items of required size including painting with one coat of aluminium paint over a coat of red oxide/primer complete after taking down old unserviceable bracket all as specified and directed.
S&F for LED secruity light fitting of capacity 70w/72w LED street light fitting with LED lamps in aluminium PDC housing, toughened glass cover with IP65 protection with 4 KV inbuilt surge protector and cable connection from looping box to light fitting and testing and including removing of old unserviceable fittings complete all as specified and directed. (Make:- Crompton cat No.LSTP-72-CDL/Havells cat No.ENDURAPEARLPLUSSL70WLED757SASYTOPC as approved)
S&F for LED security light fitting of capacity 90 Watt LED street light fitting in aluminium PDC housing, toughened glass cover with IP65 protection with 4/5 KV inbuilt surge protector and cable connection from looping box to light fitting and testing and including removing of old unserviceable fittings complete all as specified and directed. (Make:-Crompton Greaves cat No.LSTP-90-CDL /Havells cat No.90WLED757SASYBOTG as approved)
S&F for 35 watts/40 watts LED post top lantern with LED lamp made in cast aluminium spigot housing with decirative opal polycarbonate diffuser and IP65 protection and providing suitable fixing arrangements such as lugs, glands, nuts,bolts and washers complete all as specified and directed. (Make :- Bajaj, Model BGCL 40 W LED WH for LED Lamp 40W /Havells cat No : 35WLED757PSYMTOPC for LED Lamp 35W as approved)
S&F for 1 x 200 watt, LED flood light fittings, powder coated pressure die cast aluminium compact high power with heat resistant toughened glass with lens, proper locked with built in short circuit protection, over load protection, and surge protection, high/low voltage cut off and including removing of old unserviceable fittings complete all as specified and directed. (Make:-Crompton cat ref No.LFLPI-200-CDL/60 / HAVELLS CAT NO. JETAIRISPLUSFLS200WLED757PSYMLTG as approved)
PUNAM ENTERPRISE
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .