Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.3 LAccepted-AOC | L1 | Accepted-AOC Accepted - Being L1 bid | |
| 2 | L2₹49.0 L+₹2.4 L (5.17%)Rejected-AOC | L2 | Rejected-AOC Rejected - Being higher than L1 bid | |
| 3 | L3₹49.6 L+₹3.0 L (6.46%)Rejected-AOC | L3 | Rejected-AOC Rejected - Being higher than L1 bid | |
| 4 | L4₹49.7 L+₹3.2 L (6.83%)Rejected-AOC | L4 | Rejected-AOC Rejected - Being higher than L1 bid | |
| 5 | L5₹50.1 L+₹3.5 L (7.51%)Rejected-AOC KALIBARI BAZAR TUPKHANA PART I PO ARUNACHAL P S SILCHAR DISTT CACHAR ASSAM 788 025 | SILCHAR | CACHAR | ASSAM | 788025 | L5 | Rejected-AOC Rejected - Being higher than L1 bid |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
18 Jun 2021, 6:00 pmClosed
GE SILCHAR
GE SILCHAR
PERIODICAL SERVICES WITH ALLIED WORKS FOR OTM AND MD ACCN ON THE EAST SIDE AT MASIMPUR MIL STN AND REPAIR REPLACEMENT OF SUBMAIN WIRING TO OTM ACCN UNDER GE SILCHAR
2021_MES_445480_1
8631/E8
Open Tender
Civil Works
Item Rate
270 days
MASIMPUR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE SILCHAR
₹90,000
Yes
3 Jul 2021
25 May 2021
19 Jun 2021
25 May 2021
18 Jun 2021
14 Jun 2021
Amount
Taking down cement plaster on brick or stone walls etc. including raking out joints hacking for key scrubbing down with water, complete all as specified and directed.
Material and labour for rendering 15 mm thick cement rendering in two layer each 10+5 mm thick on fair faces of brick wall or concrete surfaces with cement mortar 1:4 & water proofing compound mixed with second layer @3%, finished fair and even complete all as specified and directed. Note : The quoted rate inclusive of water proofing compound.
Material and labour for 5 mm thick rendering with cement mortar 1:3 on fair faces of ceiling surfaces finished the surfaces even and fair complete all as specified and directed.
Material and labour for 10 mm thick rendering with cement mortar 1:6 on other than fair faces of brick wall or concrete surfaces finished the surfaces even and fair complete all as specified and directed.
Material and labour for preparation of new or previously untreated wall surfaces and applying three coats of white wash complete all as specified.
Material and labour for preparation of new or previously untreated ceiling surfaces and applying three coats of white wash complete all as specified and directed.
Material and labour for preparation of new or previously untreated wall surfaces and applying two coats of oil bound distemper over a coat of primer complete all as specified and directed.
Material and labour for preparation of new or previously untreated wall surfaces and applying two coats of cement based paint over a coat of cement primer complete all as specified and directed..
Material and labour for preparation of new or previously untreated wall surfaces and applying two coats of exterior acrylic emulsion paint (anti fungal) over a coat of primer complete all as specified and directed.
Material and labour for preparation of old decorated plastered or unplastered wall surfaces including brooming down or steel wire brushing, scrapping down smoke, soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc and applying one coat of white wash complete all as specified and directed.
Material and labour for preparation of old decorated plastered or unplastered ceiling surfaces including brooming down or steel wire brushing, scrapping down smoke, soot, moulds , moss and efflorescent salts and trading oil and greasy spots etc and applying one coat of white wash complete all as specified and directed.
Material and labour for preparation of old decorated plastered or unplastered wall surfaces including brooming down or steel wire brushing, scrapping down smoke, soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc and applying one coat of cement based paint as per manufacturer instruction complete all as specified and directed.
Material and labour for preparation of old decorated plastered or unplastered wall surfaces including brooming down or steel wire brushing, scrapping down smoke, soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc and applying two coats of cement based paint after one coat of cement primer as per manufacturer instructioncomplete all as specified and directed.
Material and labour for preparation of old decorated plastered or unplastered wall surfaces including brooming down or steel wire brushing, scrapping down smoke, soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc and applying one coat of colour wash complete all as specified and directed.
Material and labour for preparation of old decorated plastered or unplastered wall surfaces including brooming down or steel wire brushing, scrapping down smoke, soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc and applying one coat of oil bound distemper complete all as specified and directed.
Material and labour for preparation of old decorated plastered or unplastered wall surfaces by complete removal of existing wall surfaces treatment of any description and all unnecessary nails shall be removed, the holesand minor cracks will be filled with putty to make the surfaces even and smooth, complete all as specified and directed.
Material and labour for applying two coats of oil bound distemper over a coat of primer and a thin layer of wall putty complete all as specified and directed. (Note:Preparation of surfaces shall be measured and paid seperately under item no. 16)
Material and labour for applying two coats of oil bound distemper over a coat of primer complete all as specified and directed. (Note: Preparation of surfaces shall be measured and paid seperately under item no. 16)
Material and labour for applying two coats of oil premium exterior acrylic emulsion paint ( Anti fungal) over a coat of primer complete all as specified and directed. (Note: Preparation of surfaces shall be measured and paid seperately under item no. 16)
Material and labour for preparation of old painted plastered wall surfaces of any description over 10 cm girth or width, not otherwise described and applying one coat of plastic emulsion paint complete all as specified and directed.
Material and labour for preparation of old painted wooden surfaces of any description, not otherwise described exceeding 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
Material and labour for preparation of old painted wooden surfaces of any description, not otherwise described not exceeding 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
Material and labour for preparation of old painted steel surfaces of any description, not otherwise described exceeding 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
Material and labour for preparation of old painted steel surfaces of any description, not otherwise described not exceeding 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
Material and labour for old painted plastered wall surfaces of any description over 10 cm girth or width, not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed.
Material and labour for preparation of old decorated plastered or unplastered wall surfaces including brooming down or steel wire brushing, scrapping down smoke, soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc and applying one coat of exterior acrylic emulsion paint complete all as specified and directed.
Material and labour for preparation of old painted wooden surfaces of any description, exceeding 10 cm width or girth and applying one coat of synthetic varnish complete all as specified and directed.
Material and labour for preparation of old painted galvanized steel surfaces of any description, not otherwise described exceeding 10 cm width or girth and applying one coat of anti corrosive enamel paint for roof covering complete all as specified and directed.
Material and labour for preparation of old painted galvanized steel surfaces of any description, not otherwise described exceeding 10 cm width or girth and applying two coats of anti corrosive enamel paint for roof covering over a coat of primer complete all as specified and directed.
Material and labour for writing letters or figures (Block. Roman, Italic or Indian) not exceeding 30 cm high by using approved synthetic enamel paint complete all as specified and directed.
Material and labour for writing Stops, commas, short lines, dashes, hyphens, brackets, etc. by using approved synthetic enamel paint complete all as specified and directed.
Material and labour for painting lines, dashes, arrows, letters, etc on roads, pavements and the like exceeding 10 cm wide with road marking paint with white or golden yellow complete all as specified and directed.
Material and labour for painting lines, dashes, arrows, letters, etc on roads, pavements and the like not exceeding 10 cm wide with road marking paint with white or golden yellow complete all as specified and directed.
Taking down carefully submain wiring including all accessories without disturbing existing wiring fittings fixtures etc and making good to the disturbed surfaces all as directed and as specified in any type and size complete all as specified and directed.
Material and labour for Sub main wiring with approved colour coding as per IS with three single core PVC insulated cable with stranded copper conductor of size 4.0 Sq. mm nominal area and drawing into PVC non metallic rigid PVC casing including one run of PVC insulated with 4.0 Sqmm (nominal area) stranded copper conductor as earth wire complete all as specified and as directed. Note: Two runs of 4 sqmm cable for phase & neutral, one run of 4 sqmm cable for earthing and one run of PVC casing caping will be measured as one unit.
Material and labour for Sub main wiring with approved colour coding as per IS with three single core PVC insulated cable with stranded copper conductor of size 6 Sq. mm nominal area and drawing into PVC non metallic rigid PVC casing including one run of PVC insulated with 6.0 Sqmm (nominal area) stranded copper conductor as earth wire complete all as specified and as directed. Note:- Two runs of 6 sqmm cable for phase & neutral, one run of 6 sqmm cable for earthing and one run of PVC casing caping will be measured as one unit.
Supplying and fixing 1100 Volts grade heavy duty cable PVC insulated aluminium multistranded conductor of size 6 sqmm, served with inner sheathing of PVC tape and over all PVC sheathed in service connection suspended by insulating hanges not more than 1 meter apart including 4mm suspension wire, one twin core cable flat or circular and including taking down old unserviceable wire all as specified and directed.
Supplying and fixing 1100 Volts grade heavy duty cable PVC insulated aluminium multistranded conductor of size 10 sqmm, served with inner sheathing of PVC tape and over all PVC sheathed in service connection suspended by insulating hanges not more than 1 meter apart including 4mm suspension wire, one twin core cable flat or circular and including taking down old unserviceable wire all as specified and directed.
Taking down carefully copper/ aluminium point wiring (Light, Fan, Socket or power) complete, including fixtures and fittings such as switches, ceiling roses, light fittings, regulators, etc. and removing to store yard and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed.
Material and labour for Point wiring using approved colour coding as per IS with stranded copper conductor 1.5 Sq. mm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 marked in and including heavy duty, PVC casing caping including all accessories etc ISI marked, with PVC surface boxes suitable for fixing switches, sockets and regulators including PVC insulated stranded copper conductor 1.5 Sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for the following :-
One light point controlled by one, one way switch 5 Amps
One fan point/ exhaust fan point controlled by one, one way switch 5 Amps and regulator
One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board.
One 3 pin 5 Amps switch socket outlet point controlled by one switch on same board.
One bell point controlled by one bell switch 5 Amps
All as per item No. 40 above but with stranded copper conductor 2.5 Sq mm (nominal area), two single core, PVC insulated and unsheathed cable 1100 Volt grade ISI-694 marked for 3 pin, 15 Amp socket outlet, independent, including PVC insulated stranded copper conductor 2.5 Sqmm (nominal area) single core as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed.
All as per item No. 40 above but 4 Sqmm stranded copper conductor for one power point on independent board and including 4 Sqmm earth continuity wire for AC equipments etc controlled by one SP/SPN MCB (MCB will be measured saparately) complete all as specified and directed. Note: The point wiring will be done from DBs to the Switch sockets of any size with three wires running independently for each point and with no tappings.
Supply and fix ceiling rose surface bakelite with three terminals complete all as specified and directed.
S&F switch piano flush type button single Pole 5 Amp, 1 way, complete all as specified and directed.
Supply and fix ceiling fan regulator socketed, step type, flush type heavy duty suitable to work on 230 volts Ac supply, complete all as specified and directed.
Supply and fix socket outlet 3/5 pin 5 Amps flush type, complete all as specified and directed.
S & F Switch socket combination 2 in one, 2/3 pin 6 and 15 Amp flush type , complete all as specified and directed.
Supply and fix lamp Angular holder insulated body with back plate suitable for batten fittings complete all as specified and directed.
Supply and fix Bell Push flush type 5 Amps , complete all as specified and directed.
Suply and fix for Bell Electric Ding dong type suitable for operation on 230 volt 50 HZ A C supply complete all as specified and directed.
Supply and fix wall mounted LED batten including 20 watt LED tube rod both side connection complete all as specified and directed. Make: Havells, product code: REGAL BATTEN8UPTO1X22WDSBSWH or equivalent of Bajaj/Phillips/Wipro/Syska LED/ M/S Surya Roshni Lmtd/M/S jaquar & company Pvt Ltd /Crompton Greaves.
Supply and fix wall mounted LED 20 watt tube rod, pin on both side suitable for fixing upto 22 watt battens , complet all as specified and directed.Make: Havells, product code: CRYSTAL1213T8DSTL20WLED865SGLASS or equivalent of Bajaj/Phillips/Wipro/Syska LED/ M/S Surya Roshni Lmtd/M/S jaquar & company Pvt Ltd /Crompton Greaves.
Supply and fix street/ bldg light LED luminaries 15 watt IP 66 LED, driver etc including service bracket with all accessories, complete all as specified and directed. Make:Havells,product code: ENDURAPEARLS15WLED757SAYTOPCMP or equivalent of Bajaj/Phillips/Wipro/Syska LED/ M/S Surya Roshni Lmtd/M/S jaquar & company Pvt Ltd /Crompton Greaves.
Supply and fix in repair plastic body exhaust fan, AC single phase, 240 V of size 250 mm sweep with louvers including necessary connection and replacement of flexible copper cable from ceiling rose and taking down of old unserviceable fan complete all as specified and as directed.
Dismantling of old unserviceable main switches DBs, MCB enclosures, electric meter, PVC rectangular blocks etc and keeping in safe custody either for reuse or for disposal Including making good to the disturbed surface of wall complete all as specified and directed.
Supply and fixing in repairs metal plug and socket with MCB SP 20 amp 240 V enclosure for AC/equipment with neutral and earth point complete all as specified and directed.
Supply and fix sheet metal enclosure powder coated single phase DB for fixing of MCBs, 8 ways double door with bus bar including grouting on the wall by means of screws and rawal plugs and making good disturbed surfaces complete all as specified.
Supply and fix sheet metal enclosure powder coated single phase DB for fixing of MCBs, 4 ways double door with bus bar including grouting on the wall by means of screws and rawal plugs and making good disturbed surfaces complete all as specified and directed.
Supply and fix sheet metal enclosure powder coated three phase and Neutral DB for fixing of MCBs, 4 way, 200Amps double door with bus bar including grouting on the wall by means of screws and rawal plugs and making good disturbed surfaces complete all as specified and directed.
Supply and fix MCB SP 240 volts, 50 Hz capacity 6-32 Amps complete all as specified and directed.
Supply and fix MCB SPN 240 volts, 50 Hz capacity 40 Amps complete all as specified and directed.
Supply and fix MCB TPN 4150 volts, 50 Hz capacity 63 Amps complete all as specified and directed.
Material and labour for earthing with galvanised steel earth plate electrode 60cmX60cmX 6mm thick burried directly in ground (earth pit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below ground level connected to GI Wire 4mm dia protected by 25 mm bore light grade galvanised iron pipe and other end connected to test point as directed including funnel with wire mesh and watering pipe 20 mm bore medium grade galvanised iron pipe with charcoal and common salt in alternaterlayers of 15 cm thickness all around the GI plate electrode with concrete pit in PCC 1:3:6 type C-1 with cast iron frame including cast iron cover10mm thick hinged to CI frame and 6mm MS rod for handle, necessary excavation and earth wok in hard/dense soil and disposal of spoil to a distance not exceeding 50 mtr and necessary testing complete all as shown in electrical plate No. 3 of SSR part-I all as specified and directed.
Dismantling of unserviceable UG cable including of any size and keeping in safe custody, complete all as directed.
Supply and lay cable or fixed to wall/floors XLPE insulated, PVC bedded, Galvanised steel strip or wire armoured, Electric power cable heavy duty with stranded alluminium conductors,1100 volt grade, 16 Sq mm, 4 Core, complete all as specified and directed.
Supply and lay cable or fixed to wall/floors XLPE insulated, PVC bedded, Galvanised steel strip or wire armoured, Electric power cable heavy duty with stranded alluminium conductors,1100 volt grade, 25 Sq mm, 4 Core, complete all as specified and directed.
Excavation in trenches not exceeding 1.50 metre wide and not exceeding 1.5 metre in depth and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in with soil obtained from excavation including spreading levelling watering and well ramming in layers not exceeding 25 cm complete all as specified and directed.
Removing excavated material to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
Material and labour for sub-class 'B' old size brick laid in trenches for cable protection complete all as specified and directed.
Supply and spread sand in trenches as sand cushioning to under ground cable for protection with fine river sand and provide reqd cover after punning down complete all as specified and directed. Note : Thickness of sand cushion after punning down will be measured and paid.
Material and Labour GI tube light grade 40 mm for pretection of UG Cable including dismantling of old unsv pipe complete all as specified and directed.
Taking down 600x600 mm/ 300x300mm/ round PL type light fitting down lighter complete with all accessories complete all as specified and directed.
Supply and fix 600x 600 mm LED type down lighter 36 Watt complete with drivers, connecting accessories and provision of fixing arrangement in false ceiling complete all as specified and directed. Make:- Crompton Cat No. LCPL-36-CDL(2X2) Aura 1 or equivalent in BAJAJ/PHILIPS/WIPRO/HAVELLS/SYSKA LED/ M/s SURYA ROSHNI LIMITED/M/S JAQUAR & COMPANY PVT LTD
Supply and fix 300x 300 mm LED type down lighter 9 Watt complete with drivers, connecting accessories and provision of fixing arrangement in false ceiling complete all as specified and directed. Make:- Crompton Cat No. LSDE0-09-CDL(1X1 FEET) Quartz or equivalent in BAJAJ/PHILIPS/WIPRO/HAVELLS/SYSKA LED/ M/s SURYA ROSHNI LIMITED/M/S JAQUAR & COMPANY PVT LTD.
Supply and fix round down lighter 9 watt complete with drivers, connectimg accessories and provision of fixing arrangement in false ceiling , complete all as specified and directed. Make:- Crompton Cat No. LCDE0-09-CDL Quartz or equivalent in BAJAJ/PHILIPS/WIPRO/HAVELLS/SYSKA LED/ M/s SURYA ROSHNI LIMITED/M/S JAQUAR & COMPANY PVT LTD.
Taking down MCCB's /change over of any size and capacity, complete all as specified and directed.
Supply and fix MCCB 4 Pole, 415V, adjustable type,160 Amps with breaking capacity 36KA, complete all as specified and directed.
Supply and fix MCCB 4 Pole, 415V, adjustable type,200 Amps with breaking capacity 36KA, complete all as specified and directed.
Supply and fix MCCB 4 Pole, 415V, adjustable type,250 Amps with breaking capacity 36KA, complete all as specified and directed.
Supply and fix MCCB 4 Pole, 415V, adjustable type400 Amps with breaking capacity 36KA, complete all as specified and directed.
M/S P K ROY AND SONS
M/S MOLOY KUMAR DEY
M/S TAPAN KUMAR RAY
M/S SANJIB DEB
M/S PIJUSH BHATTACHARJEE
Younus Khan
m/s builders and suppliers
SURANA CORPORATION
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .