Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹29.9 L
EMD Value
₹59,816
Closing Date
8 Dec 2025, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EXECUTIVE ENGINEER RNB ELECTRIC DIVISION KASHMIR
RNB ELECTRIC DIVISION KASHMIR ENGINEERING COMPLEX
Const of Transit Accommodation for Kashmiri Migrant Employees at Sheikhpora Budgam B.W.O Providing of internal electrification of 23BHK 16 Flats,Block W Old Block B with street lighting lumanaries at Transit Accommodation Sheikhpora Budgam
2025_PWDJK_296731_1
NIT No.208/2025-26 Dt/28/11/2025
Open Tender
Electrical Works
Percentage
15 days
Sheikhpora budgam
Please refer Tender documents.
4 documents required · 4 mandatory
₹1,100
EXECUTIVE ENGINEER RNB ELECTRIC DIVISION KASHMIR
₹59,816
28 Nov 2025
28 Nov 2025
9 Dec 2025
28 Nov 2025
8 Dec 2025
28 Nov 2025
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable of Polycab /Finolex /Havells /Anchor /RR Kabels / Salzar/ eq. make to be approved by EIC in existing surface / recessed medium class PVC conduit, with 6Amps modular switch /bell push , modular plate of Anti backteria series of Schneider /ABB /L&T /Legrand /Simens/ eq. make to be approved EIC , suitable GI box and earthing the point with 1.5 s q.mm FRLS PVC insulated copper conductor single core cable etc. as required. ( P+N+e for Normal and invertor points per room is to be provided )
Wiring for lightl power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in existing surfacel recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. of Polycab /Finolex /Havells /Anchor /RR Kabels / Salzar / eq. make to be approved EIC
2 X 1.5 sq. mm +1 X1.5 sq. mm earth wire
2 X 2.5 sq. mm +1 X 2.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in existing surface / recessed medium class PVC conduit as required. of Polycab /Finolex /Havells /Anchor /RR Kabels / Salzar / eq. make to be approved EIC
2 X4 sq. mm + 1 X4 sq. mm earth wire with p/f of Copper thimbles of required size and numbers to be fixed on i/p and op sides dully crimped with termination and rolling of colour coded tape
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing of 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. ( Anti backteria series of Schneider /ABB /L&T /Legrand/Simens / eq. make to be approved EIC , )
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing of 2 No's of 3 pin 5/6 A modular socket outlet and 2 No's of 5/6 A modular switch, connections etc. as required. ( Anti backteria series of Schneider /ABB /L&T /Legrand /Simens / eq. make to be approved EIC)
Supply ,and fixing of 16 Amps 3 Pin Top of SSK /Anchor / eq. make to be approved EIC
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.( Anti backteria series of Schneider /ABB /L&T /Legrand / eq. make to be approved EIC)
Supply ,Installation ,Testing and commissioning of AC/DC Call Bells
Supply and laying of 25 mm dia medium class PVC medium grade Conduit to berecessed on walls / floor complete with all allied accrues like bends, tees etc. for paving way of laying of wires of haeting points /circuits ,machine points /circuits and sub mains .The Job includes cutting of walls / floors with required hydraulic cutter and refacing of walls with cement plaster of required ratio or with P.O.P after laying of conduits refacing to its original position by way of supply and applying of painting of required colour to effected area's.Anchor/Polycab/Finolex/TMT Plus / eq. make to be approved EIC.
Supply, Installation, Testing and Commissioning of 1200 mm sweep,BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC)Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2nos. canopies, shackle kit, safety rope, copper winding, Power Factornot less than 0.9, Service Value (CM/M/\N) minimum 6.00,Air deliveryminimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019),THD less than 10%, remote or electronic regulator unit for speedcontrol and all remaining accessories including safety pin, nut bolts,washers, temperature rise=75 degree C (ma><.), insulation resistancemore than 2 mega ohm, suitable for 230 V, 50 Hz, single phase ACSupply, earthing etc. complete as required of of Usha / Crompton Greaves / Orient /Helonix / eq. make to be approved EIC
Supply, Installation testing and commissioning of 300 mm Wall fans of Usha / Crompton Greaves / Orient /Helonix / eq. make to be approved EIC incl making of necessary connections and making of necessary space in walls / Windows as per site.
Supply ,Installation ,testing and Commissioning of 9-12 Watts LED Bed Light fittings of GM / Philips /Trulux /Wipro / eq. make to be approved EIC
Supply, Installation testing and commissioning of 250 mm sweep Exhaust Fans of Usha / Crompton Greaves / Havel's/ eq. make to be approved EIC incl making of necessary connections and making of necessary space in walls / Windows as per site.The Job includes providing and fixing of shutter of suitable size fabricated out of CGI Sheet (as per approved sample)
Supply ,installation ,Testing and Commissioning of 18-20 Watts ,4 ft long LED tube light fitting having aluminium Body (Commercial type) of standard make dully isi marked ,incl ceiling rose and 2-core transparent wire for connections complete job.The batten shall have only aluminium housing with polycarbonate/polystyrene diffuser (Diffuser-Non yellowing type) & polycarbonate endcaps. The luminaire should have a LEDs with colour consistency SDCM ≤ 5, CRI ≥ 80 and CCT of 6500K. Luminaire shall be designed to emit initial system lumen output of 2200 lumens with minimum system efficacy of 120 lumen/watt. The luminaire shall comply to lifetime of 50000Hrs @ L70B50 with design ambient temp 45°C. The electronic driver used shall have a power factor ≥0.95 and THD ≤10%, suitable for an operating voltage range of 140-270V AC, THD≤10%, Current Ripple ≤5%, Internal surge protection should be minimum 4KV, electrical insulation class should be Class I. The luminaire should be of Class B serviceability. The luminaire should be at least IP20 & IK02 rated. The minimum dimensions of the batten shall be 44mm X 51mm X 1157mm. The luminaire driver shall be of the same make/manufacturer as that of LED luminaires. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79, Type test as per IS10322, "FAT" before dispatch as per IS 10322 & IK Test. The successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer before supply of material. The LED Luminaire & it's driver both should be BIS registered. Successful bidder shall submit the following reports before supply of material for approvals: LM79 issued by NABL accredited lab, LM80 issued by LED manufacturer, Type Test Certificate for luminaire as issued by NABL accredited lab, BIS certificate for LED Luminaire & Driver. The fixture sample is to be approved by
2 X 16 sq. mm + 1 X 6 sq. mm earth wire with p/f of Copper thimbles of required size and numbers to be fixed on i/p and op sides dully crimped with termination and rolling of colour coded tape
Supply ,installation ,Testing and Commissioning of 10-12 Watts ,2 ft long LED tube light fitting having PVC Body (Commercial type) of standard make dully isi marked ,incl ceiling rose and 2-core transparent wire for connections complete job.The luminaire should have a LEDs with colour consistency SDCM ≤ 5, CRI ≥ 80 and CCT of 6500K. Luminaire shall be designed to emit initial system lumen output of 1400 lumens with minimum system efficacy of 120 lumen/watt. The luminaire shall comply to lifetime of 50000Hrs @ L70B50 with design ambient temp 45°C. The electronic driver used shall have a power factor ≥0.95 and THD ≤10%, suitable for an operating voltage range of 140-270V AC, THD≤10%, Current Ripple ≤5%, Internal surge protection should be minimum 4KV, electrical insulation class should be Class I. The luminaire should be of Class B serviceability. The luminaire should be at least IP20 & IK02 rated. The minimum dimensions of the batten shall be 44mm X 51mm X 1157mm. The luminaire driver shall be of the same make/manufacturer as that of LED luminaires. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79, Type test as per IS10322, "FAT" before dispatch as per IS 10322 & IK Test. The successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer before supply of material. The LED Luminaire & it's driver both should be BIS registered. Successful bidder shall submit the following reports before supply of material for approvals: LM79 issued by NABL accredited lab, LM80 issued by LED manufacturer, Type Test Certificate for luminaire as issued by NABL accredited lab, BIS certificate for LED Luminaire & Driver. The fixture sample is to be approved by department not below the rank of SDO before installation .The Job further includes replacement warrenty of complete fixture from OEM for a period of two years reckoned from date of sucessful commissioning if damaged /Burnt out /mul functioning what so ever reason Approved make Philips / Lighting techology / Trilux /wipro /Regent /Endo (to be approved before installation)
Supply ,Installation ,Testing and Commissioning of 1P 66, 90-100 Watt LED Flood Luminaries having Aluminium body of of standard make dully isi marked ,to be fitted on walls / poles with necessary cliffs /Clamps with nuts and bolts complete job.The system efficacy of the luminaire shall be ≥120lm/w. The LEDs used in the luminaire shall be from either Lumileds, Osram, Nichia, APT Electronics and CREE make, shall have CCT of 5700°K, CR≥70, SDCM≤5, Life of 50000Hrs @ L70B50. The luminaire shall have IP rating of IP66 & IK rating of IK07. The luminaire shall have lens made of polycarbonate & optical cover made of toughened glass. The LED driver shall have operating voltage range of 140V to 270V, PF≥0.95 @ full load, THD≤ 10% @ full load, In-built surge protection of 4KV, HV Cut off @ 325V (±15V). The luminaire shall have 10KV SPD in-built inside the luminaire. The maximum dimensions of the luminaire shall be, L: 264M, Depth: 52MM & height without cradle: 203MM. The nominal weight of the luminaire shall be maximum 2.4KGs. The luminaire driver & it’s SPD shall be of the same make/manufacturer as that of LED luminaires. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79, Type test as per IS10322, "FAT" before dispatch as per IS 10322 & IK Test. The successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer before supply of material for approval. The LED Luminaire & it's driver both should be BIS registered. Successful bidder shall submit the following reports before supply of material for approvals LM79 issued by NABL accredited lab, LM80 issued by LED manufacturer, Type Test Certificate for luminaire as issued by NABL accredited lab, BIS certificate for LED Luminaire & Driver.The fixture sample is to be approved by department not below the rank of SDO before installation .The Job further includes replacement warrenty of complete fixture from OEM for a period of two years reckoned from date of sucessful commissioning if damaged /Burnt out /mul functioning what so ever reason Approved make Philips / Lighting techology / Trilux /wipro/Regent /Endo/ eq. make (to be approved before installation)
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/lsolator) of Legrend /L&T /ABB /Simens /Schinder / eq. make to be approved EIC
6 way (4 + 18), Double commercial type
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required.(But without MCB/RCCB/Isolator) of Legrend /L&T /ABB /Simens /Schinder / eq. make to be approved EIC
16 way, Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioninq etc. as required of legrand / ABB /Schneider /L&T /Simens / eq. make to be approved EIC
Supplying and fixing of 40 Amps rating DP 240/415 volts (10KA) of Legrend /L&T /ABB /Simens /Schinder make dully isi marked complete with connections.of Legrand / ABB /Schneider /L&T /Simens / eq. make to be approved EIC
Supplying and fixing of 63 Amps rating DP 240/415 volts (10KA) of Legrend /L&T /ABB /Simens /Schinder / eq. make to be approved EIC dully isi marked complete with connections.
g tool incl making of necessary connections
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
3 1/2 X 95 sq.mm(45 mm)
Supply,Laying,Testing & Commissioning of 95 sq.mm 31/ 2- core armored Al Cable XLPE/ PVC Insulated and Steel sheathed of Havells/paramount / eq. make to be approved EIC, including cost thimbles on input aswell as output sides dully crimped with hydraulic crimpin
Supply and laying of DWC double layer Corrigated pipe having 75 mm dia to be laid under ground upto 50 Cm's in deep including execuation and refilling back and disposal of surplus earth complete job.
Supply and installation of 5 KG ,Co2 Fire extinguisher of standard make
Earthing with G.l. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoall coke and salt as required.The job includes providing and fixing of main hole PVC Chamber with its cover complete job
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.06 MB
BOQ_961464.xls
BOQ • 0.45 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .