Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.0 CrAccepted-AOC 35 B BHERU VILLAS SARDAR CLUB SCHEME AIR FORCE JODHPUR 342 011 RAJASTHAN | JODHPUR | JODHPUR | RAJASTHAN | 342011 | ₹37.0 Cr Quoted ₹37.2 Cr | L1 | Accepted-AOC Being lowest and reasonable |
| 2 | L2₹37.5 CrRejected-Finance K 99 LGF KALKAJI NEW DELHI 110 019 | NEW DELHI | SOUTH EAST DELHI | DELHI | 110019 | ₹37.5 Cr | L2 | Rejected-Finance Not being lowest |
| 3 | L3₹42.0 CrRejected-Finance | ₹42.0 Cr | L3 | Rejected-Finance Not being lowest |
| 4 | L4₹45.5 CrRejected-Finance | ₹45.5 Cr | L4 | Rejected-Finance Not being lowest |
| 5 | L5₹48.9 CrRejected-Finance | ₹48.9 Cr | L5 | Rejected-Finance Not being lowest |
Tender Value
₹33.5 Cr
EMD Value
₹15 L
Closing Date
19 Jan 2023, 6:00 pmClosed
CHIEF ENGINEER NAVY VISAKHAPATNAM
CHIEF ENGINEER NAVY STATION ROAD VISAKHAPATNAM
DEMOLITION RECONSTRUCTION OF CERTAIN OFFICERS MARRIED ACCOMMODATION 48 DUS AT AMZARI PARK PHASE II AT VISAKHAPATNAM
2022_MES_551096_1
85413
Open Tender
Civil Works
730 days
GARRISON ENGINEER P N VISAKHAPATNAM
AS PER NIT
8 documents required · 8 mandatory
₹3,000
Garrison Engineer (P) N VISAKHAPATNAM
₹15 L
Yes
24 Feb 2023
10 Sept 2022
21 Jan 2023
10 Sept 2022
19 Jan 2023
11 Jan 2023
Amount
Schedule "A" Part – I to Schedule "A" Part – XV: NOTE: Schedule "A" Part – I to Part – XV are prepriced by MES. Bidders shall insert their Lumpsum amount in Green coloured field under Column - 6 only
Lumpsum price worked out by the contractor for "BUILDINGS & STRUCTURES", as listed in Schedule "A" Part – I
Lumpsum price worked out by the contractor for "SITE CLEARANCE / EARTH WORK/EXCAVATION", as listed in Schedule "A" Part – II
Lumpsum price worked out by the contractor for "PILE FOUNDATION ", as listed in Schedule "A" Part – III
Lumpsum price worked out by the contractor for "INTERNAL ELECTRIFICATION", as listed in Schedule "A" Part – IV
Lumpsum price worked out by the contractor for "INTERNAL WATER SUPPLY", as listed in Schedule "A" Part – V
Lumpsum price worked out by the contractor for "SEWAGE DISPOSAL", as listed in Schedule "A" Part – VI
Lumpsum price worked out by the contractor for "EXTERNAL WATER SUPPLY", as listed in Schedule "A" Part – VII
Lumpsum price worked out by the contractor for "EXTERNAL ELECTRIFICATION", as listed in Schedule "A" Part – VIII
Lumpsum price worked out by the contractor for "ROADS /PATH/HARD STANDING", as listed in Schedule "A" Part – IX
Lumpsum price worked out by the contractor for "AREA DRAINAGE", as listed in Schedule "A" Part – X
Lumpsum price worked out by the contractor for "COMPOUND WALL/ GATE", as listed in Schedule "A" Part – XI
Lumpsum price worked out by the contractor for "FIRE FIGHTING SYSTEM & FIRE ALARM", as listed in Schedule "A" Part – XII
Lumpsum price worked out by the contractor for ""LIGHTENING PROTECTION ", as listed in Schedule "A" Part – XIII
Lumpsum price worked out by the contractor for "PVC CONDUIT", as listed in Schedule "A" Part – XIV
Lumpsum price worked out by the contractor for "DEMOLITION", as listed in Schedule "A" Part – XV
Schedule "A" Part - XVI: [Miscellaneous Items] [Pile Foundation, Internal Electrification, Internal water supply, , External Water Supply, External Electrification, Road/Path/ Hard standing, Fire fighting system & Fire alarm, Lifts, Aviation Light, DG Set, geyser, Solar Power inverter, lightening protection PVC Conduit and demolition ]
PILE FOUNDATION
Boring for bored cast in situ piles 600 mm dia in any type of soil/clay/soft rock except hard rock/fractured rock and getting out and disposal of spoil out side MD land using HYDRAULIC RIG complete all as specified and directed.
Boring for bored cast in situ piles 600mm dia in hard rock / fractured rock and getting out and disposal of spoil out side MD land using HYDRAULIC RIG complete all as specified and directed.
Boring for bored cast in situ piles 450 mm dia in any type of soil/clay/soft rock except hard rock/fractured rock and getting out and disposal of spoil out side MD land using HYDRAULIC RIG complete all as specified and directed.
Boring for bored cast in situ piles 450mm dia in hard rock / fractured rock and getting out and disposal of spoil out side MD land using HYDRAULIC RIG complete all as specified and directed.
Chipping out piles up to cut off level including disposal of spoil to out side MD land all as specified and as directed.
Carrying out Initial load [Compression] test on 450mm dia piles, complete all as specified and directed.
Carrying out Initial load [Lateral] test on 450mm dia piles, complete all as specified and directed.
Carrying out Initial load [Compression] test on 600mm dia piles, complete all as specified and directed.
Carrying out Initial load [Lateral] test on 600mm dia piles, complete all as specified and directed.
Carrying out routine load test [Compression] on 450mm dia piles, complete all as specified and directed.
Carrying out routine load test [Lateral] on 450mm dia piles, complete all as specified and directed.
Carrying out routine load test [Compression] on 600mm dia piles, complete all as specified and directed.
Carrying out routine load test [Lateral] on 600mm dia piles, complete all as specified and directed.
Carrying out initial pullout test on 450mm dia piles, complete all as specified and directed.
Carrying out initial pullout test on 600mm dia piles, complete all as specified and directed.
Carrying out low strain integrity test on 600mm dia piles including analysing the results complete all as specified and directed.
Carrying out low strain integrity test on 450mm dia piles including analysing the results complete all as specified and directed.
Internal Electrification
All as per Serial Item No. 33 above but one 3/5 pin 5 Amp socket outlet point controlled by one switch on same board.
All as per Serial Item No. 33 above but one 3/5 pin 5 Amp socket outlet point controlled by one switch on independent board.
All as per item No.33 here-in-before but controlled by two two way switch complete all as specefied and directed.
Supply and fixing of ceiling fan complete with blades, down rod and other accessories, AC 230 Volts, 1200 mm sweep, min air delivary 210 CFM with service value 6.00, BEE, 5 star rated with brushless direct current motor [BLDC] including connecting with 1.0 Sqmm, 2 core copper conductor from ceiling rose complete all as specified and as directed.
Supply and fixing wall mounted fan, AC single phase, 230 volts of size 400mm sweep, 5 star rating, connection with 1.0 sqmm copper conductor flexible wire from ceiling rose complete all as specified and as directed.
Supply and fixing exhaust fan, 250mm sweep, plastic body, heavy duty with louvers, AC single phase, 230 volts, connection with 1.0 sqmm copper conductor flexible wire from ceiling rose including making necessary opening and making good the disturbed surface complete all as specified and as directed.
Supply and fixing exhaust fan, 300 mm sweep, metallic body, 900 RPM heavy duty with louvers, AC single phase, 230 volts , connection with 1.0 sqmm copper conductor flexible wire from ceiling rose including making necessary opening and making good the disturbed surface complete all as specified and as directed.
S&F energy efficient LED Tube light fitting with tube 5W or nearest size, 240 Volts, 50 Hz, surface mounted, decorative ultra slim square profile LED light fixture with extruded polycorbonate environmental friendly, energy efficient ready to use pack of complete mounting brackets including connecting up with 1.0 Sqmm 3 core flexible copper conductor cable complete all as specified as directed
S&F energy efficient LED Tube light fitting with tube 10W or nearest size, 240 Volts, 50 Hz, surface mounted, decorative ultra slim square profile LED light fixture with extruded polycorbonate environmental friendly, energy efficient ready to use pack of complete mounting brackets including connecting up with 1.0 Sqmm 3 core flexible copper conductor cable complete all as specified as directed
S&F energy efficient LED Tube light fitting with tube 18/20W or nearest size, 240 Volts, 50 Hz, surface mounted, decorative ultra slim square profile LED light fixture with extruded polycorbonate environmental friendly, energy efficient ready to use pack of complete mounting brackets including connecting up with 1.0 Sqmm 3 core flexible copper conductor cable complete all as specified as directed
S & F energy efficient LED security light fitting with tube 30 watts new generatiion energy saving & environmental friendly long life, made up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having top opening separate driver compartment with IP66 protection pre-wired and connecting up with with 1.0 Sqmm copper conductor cable upto connector including 1.5 metre long GI tubing light grade bracket of 32 mm dia bend to shape for fixing on wall/ pole with suitable MS bracket nuts, bolts etc., complete all as specified and directed.
M & L for sub-main wiring with 10.0 sqmm nominal area four single core PVC insulated unshethed multi-stranded FRLS copper conductor cable including one 10.0 sqmm PVC insulated unshethed multi-stranded copper conductor cable for earth wire drawn through 25 mm dia PVC conduit complete all as specified and as directed. Note :(i) Four run of 10.0 Sqmm + one run of 10.0 Sqmm as a earth wire cable + one run of PVC conduit shall be measured as an one Unit.
M & L for sub-main wiring with 4.0 sqmm nominal area two single core PVC insulated unshethed multi-stranded FRLS copper conductor cable including one 4.0 sqmm PVC insulated unshethed multi-stranded copper conductor cable for earth wire drawn through 20 mm dia PVC conduit complete all as specified and as directed. Note :(i) Two run of 4.0 Sqmm + one run of 4.0 Sqmm as a earth wire cable + one run of PVC conduit shall be measured as an one Unit.
Supply, install, testing of Smart three phase energy meter with suitable housing enclosure and including the following complete all as specified and as directed. AC Three phase four wire, tamper proof, static meter of Class 1.0, 415 Volts, 50 Hz, 10A-60A confirming to IS-16444 and relavant IEC standards with in-built 865-867 Mhz radio frequency communication facility with self healing mesh network with default and on demand display, billing data generation facility, anti-tamper features, micropocessor and LED/LCD based circuitry. Meter should support the following data: 30 min instantaneous data for Voltage, current, power factor, power, cumulative energy and frequency, 30 load survey data for energy, monthly billing survey for cumulative energy and max demand. Meter should have connect/ Disconnect functionally operable from pre-paid billing software Meter should support open communication protocol DLMS with the software Make: Secure/L&T/ Schneider Note:-[a] The Meter would be possible to run in both prepaid and postpaid mode. [b] The contractor shall submit warranty for meter for a period of 05 years
M & L earthing complete with galvanised steel earth plate electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of Plate not less than 1.50 m below normal ground level connected to GI earth lead wire 4.0 mm dia [earth lead] and GI pipe 15 mm, light grade for earthing lead protection to the extent of maximum 7.5m, earth plate electrode surrounded by 150 mm thick packed layers of charcoal and common salt filled in alternate layers, connected to the plate by means of GI Bolts & Nuts complete all as per electrical plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, charcoal, common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. complete all as specified. Note: GI earth wire upto 7.5 metres shall be deemed to be included in the quoted lumpsum and beyond 7.5 metre shall be measured and paid separately under relavent item.
Internal Water Supply
S & F 15 mm dia bib tap long body, fancy type, chromium plated, screwed down and fixed suitable for 15 mm inner dia pipe complete all as specified and as directed. Note: The maximum flow rate will be 03 LPM
S & F 15 mm dia bib tap, cast copper alloy, chromium plated, screwed down and fixed suitable for 15 mm inner dia pipe complete all as specified and as directed. Note: The maximum flow rate will be 03 LPM
S & F CP mixer for mixing hot and cold water fancy type, chromium plated, screwed down for pipe, with two outlets going (one for bib tap and other for shower) complete all as specified and as directed. Note: The maximum flow rate will be 03 LPM
S & F 15 mm dia bib tap two way, fancy type screwed down and fixed suitable for 15 mm inner dia CPVC pipe complete all as specified and as directed. Note: The maximum flow rate will be 03 LPM
S & F 15 mm health faucet, chromium plated, fancy type with steel flexible complete suitable for 15 mm inner dia CPVC pipe complete all as specified and as directed. Note: The maximum flow rate will be 03 LPM
SEWAGE DISPOSAL/ ROAD/PATH/HARD STANDING/ AREA DRAINAGE
Removal of excavated surplus soil outside MD land complete all as specified and directed.
S&F Precast SFRC Cover extra heavy duty [rectangular] of Grade [EDH-35] conforming to IS 12592-2002, set in cement mortar (1:4) including cover complete all as specified and directed.
External Water Supply
Supply, install, testing and commissioning of Monoblock pump set with minimum rating as 15 HP, 70 metre head, 5.1 LPS with delivary size of 80 mm bore, 4 pole, 415 Volts, 50 Hz, AC 3 phase supply, electric driven, including of air valve at delivary, pressure guage along with cable tray and suitable base and PCC foundation and connecting with coper conductor cable from pumpset to starter/ LT panel complete all as specified and as directed.
M&L for LT made out of powder coated CRCA sheet 2.00 mm thick indoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size, weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear including nuts/ bolts etc., to be made of rust proof material including tinned aluminium bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz, 415 V, 200 Amps capacity busbar confirming to IS 8623 complete with necessary internal electric connection as required, provision and including the following.
INCOMER [a] MCCB AC 3 Phase 415 V, 50Hz, microprocessor release 4 pole 63 Amps capactiy 25KA (ICS=ICU 100%) with adjustable type thermal and magnetic setting release - 01 No. OUTGOING [b] MCB AC 3 Phase 415 Volts, 50Hz, TP 32 Amps capactiy 16KA 'C' curve - 03 Nos [c] MCB AC 3 Phase 415 Volts, 50Hz, SPN 16 Amps capactiy 16KA 'C' curve - 01 No [d] Automatic star delta starter 415 Volts, 50 Hz, 4 pole, 15 HP - 02 Nos [e] Indicating lamp for On/OFF/Trip and phase indication with control fuse/MCB - 01 set [Set of 03] [f] Multifunctional panel meter to measure Voltage, current, frequency, power factor, KWH etc., with all connected CT's - 01 Set
Supply and fix flanged end lift type Foot valve 100 mm dia with brass strainer, suitable flanges, nuts, bolts, gaskets complete all as specified and as directed.
M & L for masonry valve chamber of size 1000 X 1000 X 1000 mm [interanl dimensions] comprising of 50mm thick PCC for valve including excavation and earth work in any type of soil and 200 mm thick PCC 1:4:8 type D2 foundation, brick work in CM (1:6) plastring internal surface 15 mm tick in CM (1:4) PCC (1:3:6) type B1 couping 50 x50x6 mm angle iron 3 mm thick MS plate cover complete with locking arrangement painting steel and iron surface with two coat of synthetic enamel paint over a coat of zinc chrome primer complete all as specified and as directed.
External Electrification
M&L for LT FPB made out of powder coated CRCA sheet 3.15 mm thick outdoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size, weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear including nuts/ bolts etc., to be made of rust proof material including tinned aluminium bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz, 415 V, 1200 Amps capacity busbar confirming to IS 8623 complete with necessary internal electric connection as required, provision and including the following.
INCOMER [a] ACB 3 Phase 415 V, 50Hz, microprocessor release 4 pole 800 Amps capactiy 50KA, manual draw out type - 01 No. OUTGOING [b] MCCB AC 3 Phase 415 V, 50Hz, microprocessor release 4 pole 500 Amps capactiy 35kA (ICS=ICU 100%) with adjustable type thermal and magnetic setting release - 02 Nos [c] MCCB AC 3 Phase 415 V, 50Hz, microprocessor release 4 pole 200 Amps capactiy 35 KA (ICS=ICU 100%) with adjustable type thermal and magnetic setting release - 02 No. [d] MCCB AC 3 Phase 415 V, 50Hz, microprocessor release 4 pole 100 Amps capactiy 35KA (ICS=ICU 100%) with adjustable type thermal and magnetic setting release - 02 Nos. [e] Multi functional panel meter to measure voltage, current, frequency, power factor, KWH, etc with all connected CTs - 01 Set [f] Indicating lamp for phase indication with control fuse/MCB - 01 set [Set of 03]
M&L for LT FPB made out of powder coated CRCA sheet 3.15 mm thick outdoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size, weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear including nuts/ bolts etc., to be made of rust proof material including tinned aluminium bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz, 415 V, 800 Amps capacity busbar confirming to IS 8623 complete with necessary internal electric connection as required, provision and including the following.
INCOMER [a] MCCB AC 3 Phase 415 V, 50Hz, microprocessor release 4 pole 500 Amps capactiy 35kA (ICS=ICU 100%) with adjustable type thermal and magnetic setting release - 01 No . OUTGOING [b] MCCB AC 3 Phase 415 V, 50Hz, microprocessor release 4 pole 63 Amps capactiy 25kA (ICS=ICU 100%) with adjustable type thermal and magnetic setting release - 13 Nos [c] MCB AC 3 Phase 415 Volts, 50Hz, TPN 32 Amps capactiy 16KA 'C' curve - 01 No [d] MCCB AC 3 Phase 415 V, 50Hz, microprocessor release 4 pole 100 Amps capactiy 35KA (ICS=ICU 100%) with adjustable type thermal and magnetic setting release - 02 Nos. [e] Intelligent Panel meter to measure voltage, current, frequency, power factor, kWH, etc with all connected CTs of each breakers - 01 Sets [f] Indicating lamp phase indication with control fuse/MCB - 01 set [Set of 03]
M&L for LT FPB made out of powder coated CRCA sheet 3.15 mm thick outdoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size, weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear including nuts/ bolts etc., to be made of rust proof material including tinned aluminium bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz, 415 V, 200 Amps capacity busbar confirming to IS 8623 complete with necessary internal electric connection as required, provision and including the following.
INCOMER [a] MCCB AC 3 Phase 415 V, 50Hz, microprocessor release 4 pole 100 Amps capactiy 35kA (ICS=ICU 100%) with adjustable type thermal and magnetic setting release - 01 No OUTGOING [b] MCCB AC 3 Phase 415 V, 50Hz, microprocessor release 4 pole 63 Amps capactiy 35kA (ICS=ICU 100%) with adjustable type thermal and magnetic setting release - 03 Nos [c] MCCB AC 3 Phase 415 V, 50Hz, microprocessor release 4 pole 32 Amps capactiy 25 KA (ICS=ICU 100%) with adjustable type thermal and magnetic setting release - 02 No. [d] MCB AC 3 Phase 415 Volts, 50Hz, SPN 20 Amps capactiy 16KA 'C' curve - 01 No [e] Intelligent Panel meter to measure voltage, current, frequency, power factor, kWH, etc with all connected CTs of each breakers - 01 Sets [f] Indicating lamp for phase indication with control fuse/MCB - 01 set [Set of 03]
Supply and install 175 KVAR APFC panel with Automatic Power Factor correction (APFC) with MD-XL capacitor outdoor, pedestal type totally enclosed with front and rear opening, hinged door with projected on raised platform of suitable size, microprocessor based APFC controller with minimum 6 stage suitable rated capacity duty contactor with inter bypass resistor and mounted type, dust and vermin proof free standing made out of powder coated CRCA sheet 3.15 mm thick, CPRI approved, suitable for 3 Phase, 4 wire, 415 Volts & 50 Hz system of capacity 175 KVAR system in 06 steps [12.5 KVARX 2 Steps, 25 KVAR x 2 steps, 50 KVAR x 2 steps] with angle iron support frame made out of 50x50x6 mm and fixed over suitable PCC foundation complete all as specified and as directed and comprising the following 1. Incoming - 250 Amps MCCB, 3 pole, 36 KA 2. Aluminium bus bar 400 Amps rating 3. MCBs 3P, 16 Amps, 10 KA 'C' curve - 02 Nos 3. MCBs 3P, 32 Amps, 10 KA 'C' curve - 09 Nos Instruments:- [a] RYB LED Indication lamp with control MCB - 1 Set [b] Intelligent Panel meter to measure voltage, current, frequency, power factor, kWH, etc with all connected CTs - 01 Sets Note: The Contractor shall submit panel design, drawings and technical data sheet before procurement for approval.
M & L for earthing complete with galvanised steel earth plate electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of Plate not less than 1.50 m below normal ground level connected to 32x6mm thick GI strip [earth lead] and GI pipe 50 mm, medium grade for earthing lead protection to the extent of maximum 7.5m, earth plate electrode surrounded by 150 mm thick packed layers of charcoal and common salt filled in alternate layers, connected to the Plate by means of GI Bolts & Nuts complete all as per electrical plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, charcoal, common salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. complete all as specified. Note: GI earth strip upto 7.5 metres shall be deemed to be included in the quoted lumpsum and beyond 7.5 metre shall be measured and paid separately under relavent item.
M & L for boring holes under road, pavement, hard standing by trenchless technology with horizontal directional drilling using using ultra sound technique using necessary machine including 150 mm dia HDPE pipe suitable for 0.4 mpa working pressure complete all as specified and directed.
M&L for LT sheet metal enclosure made out of powder coated CRCA sheet 2.00 mm thick indoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size, weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear including nuts/ bolts etc., to be made of rust proof material including tinned copper bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz, 415 V, 200 Amps capacity busbar confirming to IS 8623 complete with necessary internal electric connection as required, provision and including the following.
INCOMER [a] MCCB AC 3 Phase 415 V, 50Hz, microprocessor release 4 pole 63 Amps capactiy 25KA (ICS=ICU 100%) with adjustable type thermal and magnetic setting release - 01 No. OUTGOING [b] MCB AC 3 Phase 415 Volts, 50Hz, TP 32 Amps capactiy 16KA 'C' curve - 03 Nos [c] MCB AC 3 Phase 415 Volts, 50Hz, SPN 20 Amps capactiy 16KA 'C' curve - 01 No [d] Indicating lamp for phase indication with control fuse/MCB - 01 set [Set of 03] [b] Multifunctional panel meter to measure voltage, current, frequency, power factor, kWH, etc with all connected CTs - 01 Sets
S & F loop in loop out box [minimum size 130x180x77 mm] of FRP made with IP 65 protection of thermoplatic circuit breaker boxes with metric knockouts for cable entry and exit, combiclimate Cable Glands of IP66/IP67 for cable entry and Grommets IP 65 for conduit for cable exit with MCB 6 Amps, 10 KA, 'C' Curve overload and short circuit protection, terminals as bus terminals for cable with necessary fixing arrangements and with cable glands etc all as specified and directed.
S & F PVC insulated Cable PVC sheathed LT 1100 Volts grade with copper conductor of size 3 core 2.5 sqmm multi stranded drawn through rigid PVC conduit of suitable size, with suitable clamps, bolts, nuts etc., complete all as specified and as directed.
Supply and fix time switches 250 Volts, single Phase of 20 Amp rating with contactor fitted inside steel enclosure all as specified and directed.
S& F integral LED street light fitting 40 W, comprising of epoxy powder coated, high Pressure die cast aluminium housing, enclosed with glass cover in frame, internally prewiried and including connecting up with twin core twisted copper conductor cable of suitable size, including bracket made up of 32 mm dia GI pipe medium grade or suitable size as per site requirement 1.5 Mtr length fixing the light fittings with clamp, bolt, nut and washers compelte all as specified and as directed.
S& F 75 mm wide GI cable tray perforated minmum 2mm thick on walls with MS angle iron supports including bends, coupler plates etc., complete all as specified and as directed.
S& F 100 mm wide GI cable tray perforated minmum 2mm thick on walls with MS angle iron supports including bends, coupler plates etc., complete all as specified and as directed.
S& F 150 mm wide GI cable tray perforated minmum 2mm thick on walls with MS angle iron supports including bends, coupler plates etc., complete all as specified and as directed.
S& F 200 mm wide GI cable tray perforated minmum 2mm thick on walls with MS angle iron supports including bends, coupler plates etc., complete all as specified and as directed.
S& F 300 mm wide GI cable tray perforated minmum 2mm thick on walls with MS angle iron supports including bends, coupler plates etc., complete all as specified and as directed.
Fire fighting System/ Fire Alarm
M & L for 150 mm dia ductile iron pipe double flanged type centrifugally cast (spun) all as per IS:8329-2000, Class K9 including provision of specials, such as tee's, elbows, bends, reducers, taper pieces and jointing material complete all as specified and directed.
M&L for LT sheet metal enclosure made out of powder coated CRCA sheet 2.00 mm thick indoor Pedestal type totally enclosed with front opening, hinged doors of suitable size, weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, suitable for three phase and four wire LT AC, 50 Hz, 415 V, complete with necessary internal electric connection as required, provision and including the following. [a] MCB AC 3 Phase 415 Volts, 50Hz, TP 32 Amps capactiy 16KA 'C' curve - 01 No [b] Star delta starter 10HP - 01 No [c] Multifunctional panel meter to measure voltage, current, frequency, power factor, kWH, etc with all connected CTs - 01 Sets
Supply and lay PVC insulated, PVC sheathed cable with stranded copper conductor of size 1.5 Sqmm, 2 core, 1100 Volts grade complete all as specified and directed.
PVC CONDUIT
S & F telephone socket [JACK TYPE] RJ 11-1 with shutter module complete with all accessories complete all as specified and directed.
S & F TV co-axial socket 1 module complete with all accessories complete all as specified and directed.
S & F PVC junction box of size 10 cm X 15 cm [Approx] rectangular type concealed to wall to accommodate PVC connector of four way for telephone cable complete all as specified and directed.
DEMOLITION B/R & E/M
Taking down flushing cistern of any type and capacity including flushing pipe complete all as specified and directed.
Taking down water closet [europian type] complete all as specified and directed.
Taking down stainless sink of any size complete all as specified and directed.
Taking down WHB of any type complete all as specified and directed.
Taking down CP brass pillar tap complete all as specified and directed.
Taking down carefully submain wiring of any description complete all as specified and directed.
Taking down MCB distribution board with MCB's complete all as specified and directed.
Taking down old and broken ceiling / exhaust fans of any capacity complete all as specified and directed.
Taking down old bulk head/ mirror light/ security light fitting complete all as specified and directed.
Taking down old rusted geyser of any capacity complete all as specified and directed. Note: Geyser to be deposited to MES store.
(a) Fire man switch (b) Automatic rescue divide (ARD) during power failure including manual operation provision with suitable capacity of battery designed for funning the lift with full load. c) Battery operated emergency light (LED ceiling fitting), alarm (speaker for emergency alarm system to be fixed) and stop button in car with rechargeable arrangement for battery. d) Four sleek circular LED light fitting in false ceiling . e) One Sleek circular PVC heavy duty fan in false ceiling. Make for(c) & (d) : Philips / Bajaj / Havells / Crompton Greaves. f) Aluminum chequered plate (3 mm thick) as flooring joint in chequered plate should not more than one and top covering with PVC flooring complete. g) Non stop button / independent operation. h) Over load warning indicator both audio and visual type with tripping system having relays etc., (overload protecting / tripping system). j) Front landing door of stainless steel mirror finish operations with a minimum time of 10 seconds and up to a maximum time of 30 seconds. k) Car size shall be conforming to IS-3534-1976 and body to be stainless steel of 16 gauge mirror finish with stainless steel hand rail 38 mm hairline finish.
l) Set of three in number limit switches at the bottom and top most position of lift hoist ways as specified in IS. m) Mirror of 4 mm thickness of suitable size as specified. n) Specification plate with complete details . o) Continuous earthling for machine and equipments. p) Steel wire rope of adequate size as per relevant IS and as per manufacturer specifications. q) Other standard fixtures and fitting like guide rails, sheaves, counter weights with guards, buffers, gear unit breaks, control panel, locks, governor, car operational panel, power, control and trailing cables complete. r) Full length display indicator panel. s) Main drives and control shall be of latest, high effective and low power consumption. t) Suitable phase reversal relay shall be provided on the controller to protect lift/ equipment against phase reversal, phase failure and low voltage. u) Stainless steel front opening type landing door & car door with small opening for vision of size 200 mm x 800 mm with toughened glass not less than 8mm thick. Make of Toughened Glass : Safe / Saint Goblin Glass / Modiguard float glass / kesar / Aashi Indian / Atul Tuf / Hindustan pilkington glass works / Trivenin float glass. v) Intercom be connected with nearest security post. w) Brail push button to be provided in the lift car.
All as per Serial Item No.94 here-in-before but lift suitable for 13 passengers (884 Kgs)
Aviation Light
Supply and fix aviation obstruction light LED type filament-less bulb with 10 Watt bulb including standard fixing arrangements complete all as specified and as directed
S & F PVC insulated armoured Cable PVC sheathed LT 1100 Volts grade with copper conductor of size 3 core 2.5 sqmm multi stranded with suitable clamps,spacers, bolts, nuts etc., complete all as specified and as directed.
DG SET
(A) Alternator :- Standard design alternator rated at 62.5 KVA net output at site after considering de-rating as per site conditions at 0.8 (lag) power factor AC, 3 phase, 4 wire, 415 Volts, 50 Hz, 1500 RPM, self excited self regulated screen protected drip proof, IP 23 enclosure brushless design with winding in pole faces, insulating class 'H' and voltage regulation of +/- 1% at rated Voltage from no load to full load. The alternator shall be conforming to BS 2613/5000 and shall be in a position to generate supply with frequency regulation with in +/- 1% tolerance. The alternator will be suitable for tropical climate and shall generally conform to BS - 2613/5000/ IS – 4722 i) Insualation class - 'H‘ ii) Temparature rise Class - 'H‘ iii) Excitation : Self Excited iv) Regulation performance: The Voltage is kept constant with +/- 1%, manual Voltage adjustment within +/- 5% v) Frequency regulation +/- 1%
(B) Diesel Engine: - Adequate capacity of Diesel engine as accepted by the accepting officer based on manufacturers technical details, water cooled to drive independently above alternator and after considering de-rating as per site conditions after generating and reducing power consumed by accessories directly coupled through flexible coupling multi cylinder multi stroke direct injection, cold starting 1500 RPM, as per relevant ISI/BS - 5514 with an overload capacity of 10% for half an hour in 12 hours continuous running complete with standard accessories all as specified and required for safe handling and operation salient features of accessories shall be as under i)Fly wheel with housing ii) Cooling system :- Moulded radiator with fan & belts iii) Cooling Water pump : - Centrifugal type belt driven iv) Exhaust System :- Exhaust System complete with exhaust piping of suitable dia with MS pipe light grade upto & outside and 1 Metre away from the enclosure, covered with asbestos rope and aluminium foil of 28 SWG complete within the enclosure for safe exhaust without transforming vibration to the wall of the enclosure. Exhaust gas turbo charger type. Exhaust manifold Silencer : Residual type Bellows
iv) Fuel System :- Fuel injection system with fuel injectors, fuel injection solenoid switch controlled by electronic governor for 1% speed /frequency regulation, Fuel filters, Fuel hoses. v) Lub oil System : Lubricating oil filter Lubricating oil pump vi) Air Intake System : Air intake Manifold Air cleaner dry type vii) Governor :- Electronic Governor viii) Starting System :- Electric Self starter with maintenance free battery including battery charging alternator ix) Batteries :- Batteries of maintenance free of capacity as recommended by the manufacturer complete with copper conductor multi stranded leads of suitable length from self starter to the battery terminals complete with initial charge and initial fill of electrolyte all as specified and Starter gear ring Start and stop push button, Ignition key / Switch Handling and operation : Salient features of accessories shall be as under: Radiator with blower fan
Corrosion inhibitor coolant Paper element filters for fuel, lub oil and by pass Electronic governor controlled direct fuel injection system Fly wheel housing and fly wheel x) Generator Monitoring Panel : - Comprising of all standard items as mentioned under this schedule or as per standard practice iginiton key switch and start / stop arrangement, indications for Engine parameters, hour run meter, RPM meter, Engine oil pressure indicator, water/coolent temparature indicator, Battery Volt display. xi) Safety Controls : - Engine low lube oil pressure high water temparature and over speeding of engine xii) Coupling arrangement : - Flexible coupling, fly wheel to suit flexible coupling xiii) Accessories :- AVM Pads built in enclosure and for entire unit on platform. xiv) Base Frame : - Should be provided as OEM norms xvi) MS pipe line to and from the fuel tank to the DG Set
C) AMF Panel :- Factory made inbuilt type control cubical type made out of 2mm thick CRCA sheet dust and vermin proof totally enclosed with front opening of 415 Volts, 3 Phase, 4 wire, AC 50 Hz, including powder coated, copper bus bar of one and half times the rated load of 62.5 KVA alternator complete with internal wiring with PVC insulated single core copper conductor multi stranded wire of 1100 Volts grade of suitable capacity, fuses, name plates consisting of 4 pole MCCBs and Contactors of capacity as recommended by the manufacturer. Detachable cable gland plates, all controls, indicators and standard microprocessor based LED/LCD display for indicating Voltage, current, frequency, speed, kW, kWH, pf, temperature, Battery voltage, etc., g) Annuciation with indication lamps for : (i) Low lub oil pressure. (ii) High Water Temparature. (iii) Engine over speed. (iv) Battery low Voltage Controls :- a) Load on Indication b) Load off indication c) Engine start push button d) Engine stop push button e) Fault accept / reset push button
GEYSER
Supply, install, testing of geyser 25 litres storage/ heating capacity, 5 star rating with automatic ON/OFF switch, absolute temparature range knob, heat indicator and other safety devices, single phase, 50 hz, 230 Volts with and including inlet and outlet connection pipes and accessories for hot water and cold water complete all as specified and as directed.
SOLAR POWER INVERTER
Supply, install, testing and commissioning of solar panel powered inverter (sine wave) with battery back up for 08 hours capacity 04 KW (Single phase 230 Volts, 50 Hz, AC supply) complete (off grid type) with and inclusive of all electrical and mechanical accessories & stand for inverter and batteries complete all as specified and as directed. Note: [i] Solar panel of Specification 320 Wp (Minimum) polycrystaline type to be provided. [ii] Inverter and battery back up shall be placed near the staircase 3. [iii] Tubular battery of 12 Volts, 150 AH of sufficient quantity to be provided and rate quoted shall be deemed included in the cost of batteries. [iv] Manual changeover switch 20 Amps single phase, 240 Volts to be provided near inverter for switching on to normal electric supply, incase solar system fails. Cost of the same deemed to be included in the rate quoted. [v] Solar inverter supply will feed to light fittings of parking area, staircase lights, building security lights in ground floor and passage lights, staircase lights of each floor of building. [vi] Before commencement of work contractor shall submit complete wiring diagram for approval.
SCHEDULE 'A' PART-XVII PHASE -III OUTSOURCING OF 8 AND 13 PASSENGERS LIFTS AS PROVIDED UNDER THIS CONTRACT AS PER SERIAL ITEM No. 94 AND 95 DURING FIRST YEAR OF DEFECT LIABILTY PERIOD.
Manning and operation of electrically operated lifts by providing services of one lift operator [Semi Skilled] [Metric/SSC qualified with 2 to 3 years of relevant experience] for Main building comprising of 8/13 passanger lifts for main Buildings in each shift on all the days including Sunday & holidays in two shifts a day including taking care of form any pilferage, theft or damage etc. to ensure smooth and trouble free operation of lifts to the entire satisfaction of users during 1st year during Defect liability period complete all as specified and as directed.
SCHEDULE 'A' PART-XVIII PHASE -IV OUTSOURCING OF 8 AND 13 PASSENGERS LIFTS AS PROVIDED UNDER THIS CONTRACT AS PER SERIAL ITEM No. 94 AND 95 DURING SECOND YEAR OF DEFECT LIABILTY PERIOD.
Manning and operation of electrically operated lifts by providing services of one lift operator [Semi Skilled] [Metric/SSC qualified with 2 to 3 years of relevant experience] for Main building comprising of 8/13 passanger lifts for main Buildings in each shift on all the days including Sunday & holidays in two shifts a day including taking care of form any pilferage, theft or damage etc. to ensure smooth and trouble free operation of lifts to the entire satisfaction of users during 2nd year during Defect liability period complete all as specified and as directed.
Notes for item Nos. 101 & 102 : (i) The lift shall be operated daily in two shifts as directed by the Engineer-in-Charge. (ii) The timings for two shifts of 8 hours each daily i.e. First shift be from 0630 hours to 1430 Hours and Second Shift shall be from 1430 Hours to 2230 Hours. (iii) In case of non function of passenger lift, the Goods Lift installed in the same building shall be operated as directed. (iv) The work shall be supervised by adequately qualified supervisor with relevant experience of minimum 2 to 3 years items under BoQ shall be deemed to be including the same. (v) The unit rate is deemed to include for maintaining log books, record of repair /replacement of perished/unserviceable, minor adjustments, minor repairs of all accessories, cleaning/up keeping of lift and surrounding area as directed by the Engineer-in-Charge. (vi) One emergency light and necessary tools shall be available in a tool box with the operator in the shift for smooth functioning of lifts. (vii) Conveyance and communication system like mobile phone etc. shall be provided by the Bidders/Service providers to all Lift Attendants/Supervisors. (viii) The Bidders shall ensure housekeeping, environmental cleanliness of area all round the lift and the area shall be kept absolutely neat and clean. The lift attendant shall clean the Lift car cabin, all landing floors and tiles all round lift doors with necessary cleaning material such as cotton cloth and cleaning solution etc.
(ix) The Bidders shall abide by the latest Labour rules and minimum wages Act. Wages paid by the bidders to the persons employed shall not be less than the minimum wages fixed by the state/central government from time to time whichever is higher. The Bidders shall also insure the workmen employed on the job. (x) The Bidders is responsible for insurance, EPF, ESI, Bonus, Labour welfare cess et., as applicable and shall be paid to the workmen as per existing Labour rules/ Acts/ regulations and rate quoted shall be deemed to be included for the same. (xi) Dress Code : The bidders shall provide the workmen with Dark Blue Colour uniform {formal pant & T-shirt} with labels showing/ printed i.e. "Name of the firm and designation" on front and on the back of the T-shirt along with protective clothing/ gear. The bidders shall also provide shoes to the workers and the persons shall not be allowed to enter the work site without wearing shoes. (xii) INSURANCE: The Bidders shall be responsible for all Accidents/Injuries happening to the workmen. Any accident causing minor/fatal injury, partial disability due to any untoward on account of any mishandling/ wrong operation/ lack of knowledge of safety precautions or on account of any circumstances beyond his/ their control, the bidders shall be solely responsible for settling all claims of compensation to the deceased, falling which department will have a right to recover any sum indicated/ claimed by Labour commissioner/court authorities. No claim whatsoever will be entertained in this regard. No compensation is payable by the department on this account. Bidders shall provide first aid boxes to meet any emergency situations.
SCHEDULE 'A' PART-XIX PHASE -V FIRST YEAR COMPREHENSIVE MAINTENANCE OF 8 AND 13 PASSENGERS LIFTS AS PROVIDED UNDER THIS CONTRACT AS PER SERIAL ITEM No. 94 AND 95 AFTER EXPIRY OF DEFECT LIABILTY PERIOD.
Comprehensive maintenance of Electrically Operated 13 passenger lifts (884 Kgs) to serve G+12 upper floors all as mentioned vide SI No. 95 of Sch "A" Phase-I during 1st year after expiry of defects liability period all as specified and directed
Comprehensive maintenance of Electrically Operated 8 passenger lifts (544 Kgs) to serve G+12 upper floors all as mentioned vide SI No. 94 of Sch "A" Phase-I during 1st year after expiry of defects liability period all as specified and directed
SCHEDULE 'A' PART-XX PHASE -VI SECOND YEAR COMPREHENSIVE MAINTENANCE OF 8 AND 13 PASSENGERS LIFTS AS PROVIDED UNDER THIS CONTRACT AS PER SERIAL ITEM No. 94 AND 95 AFTER EXPIRY OF DEFECT LIABILTY PERIOD..
Comprehensive maintenance of Electrically Operated 13 passenger lifts (884 Kgs) to serve G+12 upper floors all as mentioned vide SI No. 95 of Sch "A" Phase-I second year after expiry of defects liability period and After completion of first year Comprehensive Maintenance.
Comprehensive maintenance of Electrically Operated 8 passenger lifts (544 Kgs) to serve G+12 upper floors all as mentioned vide SI No. 94 of Sch "A" Phase-I second year after expiry of defects liability period and After completion of first year Comprehensive Maintenance.
SCHEDULE 'A' PART-XXI PHASE -VII THIRD YEAR COMPREHENSIVE MAINTENANCE OF 8 AND 13 PASSENGERS LIFTS AS PROVIDED UNDER THIS CONTRACT AS PER SERIAL ITEM No. 94 AND 95 AFTER EXPIRY OF DEFECT LIABILTY PERIOD..
Comprehensive maintenance of Electrically Operated 13 passenger lifts (884 Kgs) to serve G+12 upper floors all as mentioned vide SI No. 95 of Sch "A" Phase-I third year after expiry of defects liability period and After completion of second year Comprehensive Maintenance.
Comprehensive maintenance of Electrically Operated 8 passenger lifts (544 Kgs) to serve G+12 upper floors all as mentioned vide SI No. 94 of Sch "A" Phase-I third year after expiry of defects liability period and After completion of second year Comprehensive Maintenance.
Note for SL No: 103 to 108:- (i) Comprehensive maintenance consists of preventive and breakdown services including replacement of material and labour for major/minor spare parts and consumables like topping of Oils/grease/door rollers/relays/door belts/gate lock contacts and hardware like bolts and nuts including load testing of lift for satisfactory performance once in a year complete and rate quoted by the tenderer includes for the above Lifts. (ii) Preventive maintenance consists of carrying out routine check by skilled personnel as specified in Particular specifications and as directed by Engineer-in-Charge and lubricating to all moving parts, topping parts, topping up of oils as per Lubrication Chart including Material and labour for all consumable and major/minor spare parts. (iii) Breakdown maintenance consists of attending to the faults that may occur and carrying out necessary repairs to electrical, control circuits and mechanical components including materials & labour for all minor & major spare parts and consumables of the lift that may occur during the operation. (iv) Fortnightly, quarterly maintenance registers shall be maintained and signed by the site engineer and contractor. (v) Load testing shall be arranged by the contractor to the Lift for which repairs were carried out as and when directed by Engr -in-Charge. (vi) All maintenance works shall be carried out by well qualified tradesmen and supervisor of OEM.
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid