Amount
Additional Electrical Works
90.12.9.3:Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench63/50 mm or nearest size
90.12.9.6:Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench110/94 mm or nearest size
90.12.5.40:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 10 sq mm
90.12.6.40:Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.4 core 10 sq mm
90.12.7.40:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp
90.12.6.35:Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 240 sq mm
90.12.6.36:Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 300 sq mm
OD16682/2024-2025:Supply of one number copper power cable 2.5 sq mm 2 core PVC / XLPE insulated armoured control cables with copper conductors for working voltages up to and including 1100 V conforming to IS 1554 part I 1988 for PVC and IS 7098 Part I for XLPE
7.5.1:Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm
7.6.1:Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Upto 35 sq. mm
7.7.1:Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle)
OD16717/2024-2025:Supply and making end termination with brass compression gland for 2x4 sq.mm pvc insulated and pvc sheathed armored copper conductor cable of 1.1 KV grade as required
9.1.32:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
14.6:Excavation of the cable trenches in hard rock not exceeding 1.5 metres in width, and lift upto 1.5 metres, including getting out the excavated soil and disposal of excavated soil as directed within a lead of 50 metres.
5.8:Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
5.14:Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
14.10:Providing and laying in position reinforced cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required (excluding reinforcement).
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.10.3:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole
OD16834/2024-2025:Supply and providing 630 A, 4 pole, manual draw out type, microprocessor based ACB with overload , instantaneous SC , delayed SC and ground fault protection 50kA
OD17681/2024-2025:Supply and fixing Flush head Actuator - Red with legend 'stop', (Contact - 1 NC) with Push button station enclosure 1/2/3 hole
OD17692/2024-2025:Supply and fixing 90/5, 10 VA , accuracy class 5P/10 Current Transformer in the existing Neutral Terminal of the 315 KVA transformer and giving connection
OD18001/2024-2025:Supply and fixing 150/5, 10 VA , accuracy class 5P/10 Current Transformer in the existing Neutral Terminal of the 500 KVA transformer and giving connection
OD18425/2024-2025:Supply and fixing 700/5 A, 10 VA, accuracy class 0.5, Tape wound Metering CT and giving connection
OD18426/2024-2025:Supply and fixing 500/5 A, 10 VA, accuracy class 0.5, Tape wound Metering CT and giving connection
OD17739/2024-2025:Supply and fixing 3 Pole Capacitor duty contactors for switching capacitor banks up to 7 kVAR with AC Coil,
OD17740/2024-2025:Supply and fixing 3 Pole Capacitor duty contactors for switching capacitor banks up to 20 kVAR with AC Coil,
OD17742/2024-2025:Supply and fixing 3 Pole Capacitor duty contactors for switching capacitor banks 50 kVAR with AC Coil,
OD17782/2024-2025:Supply and fixing Block Reactor Transformers, Copper wound,400 V suitable for 5 KVAR 460 V and giving all connections
OD17785/2024-2025:Supply and fixing Block Reactor Transformers, Copper wound 400 V suitable for 12.5 KVAR 460 V and giving all connections
OD17799/2024-2025:Supply and fixing Block Reactor Transformers, Copper wound 400 V suitable for 15 KVAR 460 V and giving all connections
OD17784/2024-2025:Supply and fixing Block Reactor Transformers, Copper wound400 V suitable for 20 KVAR 460 V and giving all connections
OD17783/2024-2025:Supply and fixing Block Reactor Transformers, Copper wound400 V suitable for 50 KVAR 460 V and giving all connections
OD18536/2024-2025:Supply and fixing 630 A TP&N Switch disconnector unit with handle assembly in the existing panel board , making connections, etc. as required.
OD18635/2024-2025:Supply and fixing 800 A TP&N Switch disconnector unit with handle assembly in the existing panel board , making connections, etc. as required.
90.16.2.4:Supply and laying of the following sizes of B class GI pipe laid 0.6 m below ground level including excavating trench of suitable size and refilling etc, as required.40 mm dia G.I. pipe ( medium class)
14.13.3:Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required100 mm dia
OD20106/2024-2025:Supply and providing H.T./L.T Cable route marker, cast iron, spike and inscription
OD20113/2024-2025:Supply and providing 200 mm X 150 mm M.V. danger notice plate
OD20196/2024-2025:Brick work with Solid cement bricks below plinth level for cable duct in required shapes and sizes using Cement mortar 1:4 ( 1 cement : 4 coarse sand)
14.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels
OD20219/2024-2025:Cutting the existing Concrete floor/road using machinery/manual including clearing the waste material from site etc. as requited for cable laying
OD20249/2024-2025:Supply and Providing Spreader terminals suitable for 400A, 4 pole MCCB and making connections
OD20264/2024-2025:Supplying and providing 25 Sq.mm FRLS PVC insulated copper conductor, single core cable in the existing panel board as required
OD20314/2024-2025:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete up to plinth level using suitable size Mild steel and Medium Tensile steel bars
OD20336/2024-2025:Supply and fixing 230V AC Panel cooling fan 150mm with plastic grill for protection from insects in the existing APFC panel with suitable type thermostat for maintaining temperature in panel board and giving connection
OD20349/2024-2025:Supply of hand glove set certified for use in 11 kV installations made with high grade rubber
OD32006/2024-2025:Fee to be paid for getting approval from Electrical Inspectorate, Meter Testing etc as per actual receipt
OD20359/2024-2025:Supply and providing approved Schematic diagram of the complete HT installation and LT panel boards in A3/A2 sheet including laminating neatly and exhibited in suitable location near the installation.
OD20378/2024-2025:Supply fabrication and installation of linked chain fencing for extending the existing fencing of RMU assembly unit made with suitable size linked chain mesh with suitable gauge wires, GI pipe poles etc and joining properly
90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
OD20383/2024-2025:Supply fabrication and erection of Base frame work for construction platform for installing Panel boards on the existing concrete slab/plinth with suitable size GI /MS C channel, Angle iron, bolt nut, painting etc. as requited at site
OD20388/2024-2025:Supply, conveyance and installation of 6 mm MS checquered plate for covering the platform and cable duct including painting
OD32067/2024-2025:Earthing with G.I. earth plate 1200 mm X 1200 mm X 12.5 mm thick including accessories, and providing masonry enclosure with 450x450x10mm cover plate having locking arrangement and watering pipe of 3 meter long etc. with charcoal/ coke and salt as required
M K V Engineering (BID ID -1966524)
Bidder Name
M K V Engineering
SAFIYULLA K V
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1094959.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .