| 1 | L1₹16.3 LAccepted-AOC | L1 | Accepted-AOC Competent committee approved the tender in favour of Ist Lowest Bidder | |
| 2 | L2₹16.7 L+₹39,922.60 (2.45%)Rejected-AOC | L2 | Rejected-AOC Competent committee rejected the file due to higher rates | |
| 3 | L3₹17.5 L+₹1.2 L (7.47%)Rejected-AOC 00 INFRONT OF S R K PG COLLEGE KOTLA ROAD OM MARKET FIROZABAD UTTAR PRADESH 283203 | FIROZABAD | UTTAR PRADESH | 283203 | L3 | Rejected-AOC Competent committee rejected the file due to higher rates |
Tender Value
₹18.2 L
EMD Value
₹18,170
Closing Date
15 Apr 2024, 5:00 pmClosed
SUPERINTENDING ENGINEER
ELECTRICITY DISTRIBUTION CIRCLE, KATJU MARG, BAREILLY
Increasing Capacity of Existing Distribution Transformer of Various Capacity at Various Places under Business Paln 2024-25 (Summer Plan) scheme under EDD-2 Bareilly
2024_MVVNL_918796_1
105/EDCB/2023-24
Open Tender
Electrical Works
Item Rate
90 days
WORK
AS PER TENDER FORM
3 documents required · 3 mandatory
₹3,540
SE,EDC
₹18,170
18 Sept 2024
17 Mar 2024
16 Apr 2024
17 Mar 2024
15 Apr 2024
17 Mar 2024
Amount
The work of safe carriage of the following material from CB Ganj store center to work site under the jurisdiction of EDD-II, Bareilly Approx. distance upto 85 Km. Including safe loading and unloading.
PCC Pole 8.5 Mtr
ACSR Weasal Conductor
AB Cable 3x50 sqmm
11/0.4 KV 3 Phase 25 KVA T/F
LT Cable 3.5x70 sqmm
Other Line material i.e., 33 KV & 11 KV pin insulater/stay/earthing complete/Disc Fitting/Disc Insulators/Dropper Channel/Crossing Bracing/ Top Channel/Binding Wire/Danger Board/Barbed Wire/numberplate/stone pad/Control Cable etc
Dismentaling of 16 KVA Transformer as per norms complete in all respect
Dismentaling of 10 KVA Transformer as per norms complete in all respect
Mounting of 25 KVA T/F Transformers as per norms complete in all respect -
Installation of 11 KV Fuse set unit to be installed on midway of 11 KV Double Pole Structure Complete in all respect
Erection of Single/Double pole in H.T/L.T lines including fitting of all accessories as per RESSPO Norms
PCC Pole 8.5 Mtr (Single)
PCC Pole 8.5 Mtr (Double)
STP 11 Mtr (Double)
Grouting of following Pole with 1:4:8 mixture in size(450x450x1500mm.) including cost of cement/BB & sand Required as per RESSPO Norms
PCC Pole 8.5 Mtr (Single)
PCC Pole 8.5 Mtr (Double)
Laying of LT Cable 3.5x70 sq mm complete in all respect
The work of Driving the earthing electrode and making connections with 6 S.W.G. GI wire as per RESSPO Norms
Laying, Stringing & Sagging of Following Conductor complete in all respect
ACSR Weasal Conductor
AB Cable 3x50 sqmm
The work of digging of pits, erection of Stay Clamp, Insulator etc.
Grouting of stays, 1:4:8 cc ratio (600x600x300mm.) as per RESPO norms.
Fixing of 3 Pahse Distribution Box complete in all respect
Supply and Fixing of Following Material as per RESPO norms complete in all respect (would be Provided by contractor through approved vendors of Discom at his own cost)
Stone Pad 300x300x75 mm
Danger Board With Clamp
Barbed Wire
Aluminium Lug 70 sqmm with Nut&Bolt
Aluminium Lug 120 sqmm with Nut&Bolt
Holding Clamp for S/s
Distrinution Box Clamp
LT Clamp with Nut & Bolt
Stay Insulator
PG Clamp
Piercing Connector
LT Shackle Insulator
Cost of Nut & Bolt for Shackle Insulator
Earthwire Clamp
LT T-Off
X Arm Holding Clamp
F Clamp With Nut & Bolt
Safe back carriage of Following item (if any) from work site to C.B. Ganj store Bareilly approx distance upto 85 Km including loading & unloading.
11/0.4 KV 3 Phase 16 KVA T/F
11/0.4 KV 3 Phase 10 KVA T/F
PAWAN SHAKTI ENTERPRISES
SHREE KRISHNA TRADING CO
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .