REPAIR/ROUTINE PREVENTIVE MAINT OF CENTRAL AC PLANT MODULAR OT AND REPAIR TO FCUs, CSUs, PAC, COOLING TOWERS CONDENSER AND CHILLED WATER PIPE LINES AND CERTAIN AHUs OF CENTRAL AC PLANTS AT NAVAL BASE KOCHI
2022_MES_531710_1
CWE(NW)KOCHI/81296
Open Tender
Civil Works
Item Rate
330 days
Kochi
As per NIT
6 documents required · 6 mandatory
₹500
GE (NS) Kochi
₹63,000
Yes
5 Sept 2022
17 Jun 2022
1 Aug 2022
18 Jun 2022
28 Jul 2022
8 Jul 2022
18 Jun 2022 - 25 Jun 2022
Amount
M & L for Monthly servicing including taking out complete air filters from ceiling suspended type AHU carefully and cleaning including arrangement of scaffolding/ladder for removing dust by using pressure water, greasing shaft and bearings, alignment of blower motor, tightening of blower V belt and refixing filters after drying all as specified and directed . Note :- Replacement of Air Filter shall be resposibility of contractor if damage occur while removing or refixing.
M & L for Monthly Servicing to the indoor unit Fan Coil Unit clean with mild Air blower in the coil side including arrangement of scaffolding/ladder for remove the inside fine filter, cleaning and fix in proper place , check the drainage water/chilled water pipelines, rectify if any leakage found complete all as specified and directed Make : Zeco
M & L for dismantling of defective condenser/chiller pump motor of capacity upto and including 5 HP after disconnectiong electric connection from motor terminal, removing defective bearing, water seal, gland bush, suitable gaskets/rubbers, nut bolts, terminal box and gland packing including reassembling, painting (preparation of surfaces and apply two coats of synthetic enamel spray paint over one coat of primer) and refixing at same location/connecting of all electrical connections all as specified and as directed.
All as per item No 3 but for capacity above 5 HP and upto 7.5 HP all as specified and directed .
M&L for dismantling of defective condenser/chiller pump motor of capacity upto and including 5 HP after disconnecting electric connection from motor terminal, transport to local work shop and taking out of bearing and re-metaling the bearing housing shaft, including rewinding with same gauge super enamelled copper insulated wire winding, turning to the required size, cleaning of stator, varnishing, drying, re-assembling, painting(preparation of surfaces and apply two coats of synthetic enamel spray paint over one coat of primer) the motor to bring in original state including fixing on the foundation all as directed.
All as per item No 5 but for capacity above 5 HP and upto 7.5 HP all as specified and directed .
M & L for dismantling of defective CT fan motor of capacity upto 3 HP including disconnectiong electric connection, fan blade and opening the motor cover, removing the burnt coil, cleaning , rewinding with Super Enamelled copper wire of existing size , insulating , varnishing , heating , baking , re assembling , replacement of motor bearing of existing size including transportation from existing location to workshop and back, refixing of electrical connections , refixing of fan bush ,and balancing of fan, recommissioning all as specified and directed .
Ditto all as per item No 7 but for capacity above 5HP and upto 7.5 HP all as specified and directed .
Ditto all as per item No 7 but for capacity above 7.5HP and upto 15HP all as specified and directed .
M & L for dismantling of defective AHU motor of capacity 3 HP including blower after disconnectiong electric connection from motor terminal and opening the motor cover, removing burnt coil, cleaning , rewinding with Super Enamelled copper wire of existing size , insulating , varnishing , heating , baking , re assembling , replacement of motor bearing of existing size including transportation from existing location to workshop and back, refixing of electrical connections, testing after repair , refixing of blower belt, alignment with blower with motor, recommissioning all as specified and directed . Note:- Rep of Accepting Officer will inspect the motor before winding work
All as per item No 10 above but for capacity above 3 HP and upto 7.5 HP all as specified and directed .
All all as per item No 10 above but for capacity above 7.5 HP and upto 15 HP all as specified and directed .
Supply and replacement in repair round type cooling tower sprinkler aluminium with distributer pipe & stay rod suitable for capacity upto 60 TR all as specified and directed. Make of CT : Paharpur/Mihir/Delta.
All as per item No 13 above but suitable upto 80 TR complete all as specified and directed.
All as per item No 13 but suitable for 80-100 TR complete all as specified and directed.
All as per item No 13 but suitable for 120 TR to 150 TR complete all as specified and directed.
All as per item No 13 but suitable for 240 TR complete all as specified and directed.
S&F in replacement of PVC Fills of suitable size for capacity 10TR to 50 TR of fine quality as per existing at site, all as specified and directed.
All as per item No 18 but for capacity 51TR to 100 TR complete all as specified and directed.
All as per item No 18 but for capacity above 100TR and upto 240 TR complete all as specified and directed.
S&F in repair PVC nozzles 3/4'' dia for rectangular type cooling tower all as specified and directed.
S & F in replacement of PVC heavy grade pipe of size 40 mm dia of appx length upto 1 mtr with having drilling holes for water spray distribution line in cooling tower including complete connection with hub, sprinklers of existing CT fan Shaft with all necessary connected arrangements for the smooth functioning of cooling tower all as specified and directed .
All as per item No 22 above but of size 100mm dia of appx length upto 1.2m complete all as specified and directed.
Supply and Fixing in repair CI 'Y' strainer of size 50 mm dia in condensing/chilled water line complete dia including modification of pipe line for fixing the strainer and replacement of flanges and nuts & bolts, packing etc all as specified and directed.Make:Advance/Leader/Castlers/Sant
All as per item No 24 but of size 65 mm dia complete all as specified and directed.
All as per item No 24 but of size 80 mm dia complete all as specified and directed.
All as per item No 24 but of size 100 mm dia complete all as specified and directed.
All as per item No 24 but of size 125 mm dia complete all as specified and directed.
Supply and fix in repair CI butterfly valve full open with operating handle of size 50 mm dia including replacement of old nuts & bolts, packings modification of flanges if necessery and all as per specified and directed.Make:Advance/Leader/Castlers/Sant
All as per item No 29 but of size 65 mm dia complete all as specified and directed.
All as per item No 29 but of size 80 mm dia complete all as specified and directed.
All as per item No 29 but of size 100 mm dia complete all as specified and directed.
Taking down corroded GI pipe line and replace with GI tubing 65 mm dia medium grade including welding, connecting and painting two coat of synthetic enamel paint all as specified and directed.
All as per item No 33 but of size 80 mm dia complete all as specified and directed.
All as per item No 33 but of size 100 mm dia complete all as specified and directed.
Supply and fixing in replacement PVC makeup water tank of 500 ltrs capacity ISI marked triple layered of suitable height and size with necessary inlet from the existing water connection point as directed by Engineer in charge at site by using pipe line connections for inlet & out let should be suitable sizes of CPVC pipes for required water discharge and outlet for continuous water flow for the smooth function of system, overflow connection and float valve assembly and a butterfly valve to connect the cooling tower all as specified and directed.
All as per item No 36 but of capacity 1000 ltrs complete all as specified and directed.
Supply and fixing in repairs ball valves ( float valve), high pressure of PTMT with epoxy coated aluminium rod and high density plastic bal screwed for iron pipe and fixed of size 20mm (Minimum weight 20mm - 210 gms) complete all as specified and directed.
Supply and fixing in repairs ball valves ( float valve), high pressure of PTMT with epoxy coated aluminium rod and high density plastic bal screwed for iron pipe and fixed of size 25mm (Minimum weight 25mm - 455 gms) complete all as specified and directed.
Supply and fix in repair dual plate check valve (NRV) of size 50 mm dia including replacement of old nuts & bolts, packings modification of flanges if necessaery and all as per specified and directed.
All as per item No 40 but of size 65 mm dia complete all as specified and directed.
All as per item No 40 but of size 80 mm dia complete all as specified and directed.
All as per item No 40 but of size 100 mm dia complete all as specified and directed.
All as per item No 40 but of size 125 mm dia complete all as specified and directed.
M & L for removal of complete FRP cooling tower including fan CT motor, fills, sprinkler/nozzle, pipes, valves and preparation of damaged surface and apply FRP sheet and suitable chemical solution (min two coat) of required quantity to make it leak proof and complete re-assembling including replacement of old nuts, bolts and washers etc as per site requirement including refixing of all removed items back fitting and painting of entire cooling tower and condensor pipe lines upto condensor shell of existing colour, alignment of fan motor and testing all as specified and as directed upto capacity 100 TR.
All as per item No 45 but for capacity above 100 TR and upto 150 TR complete all as specified and directed.
All as per item No 45 but for capacity above 150 TR and upto 240 TR complete all as specified and directed.
M&L for removing defective Micro Processor control, model no VLRP 4/5/6 Panel board of exisiting chiller unit of AC plant capacity 15 TR to 120 TR , replacing the relay assembly, calibration of Micro processor, return to site, refixing in position, setting all readings and run testing all as specified and as directed by Engineer in charge.Make of unit: Voltas,Bluestar and Carrier
Supply and fix in replacement HEPA Filter at (OT-1,2,3) from inside OT complex at INHS Sanjivani hospital with HEPA chamber box type 0.3 microns, H 13 grade, MOC (Magnesium oxy chloride) Aluminium anodised casing. Media : Water repellent Glass micro fibre media with with mini pleat patches Construction : Pleated type. Initial Pressure drops: 25 mm WG, Air Flow : 1000 CFM, Efficiency 99% down to 0.3 microns, Gasket : Provided on air outlet side, size: 610X610X75 mm (box type)/same size as existing at site Make : Imbec/Aerosol
Supply and fix in replacement of pre filter from inside OT fixed in the laminar return area, supply and fixing of Pre Filters , Flange type, EU4 Grade, 10 micron, MOC:Aluminum casing, Media : Non-woven synthetic with HDPE mesh on air outlet side Aluminium mesh Pleated support. IPD: 4.5mm, Efficiency 90% down to 10 micron, air flow: 1000cfm, Gasket ; Provided Size : 660x 360x50mm ( Flange) Make : Imbec/Aerosol
M & L, Checking of existing condition of air ducts making the arrangement of visualization and the process for disinfection for Indoor air quality of AC ducts including plenum box, supply air, return air ducts with robotic camera, compressed air with flipper, HEPA Negative machine, air compressor, various types of air nozzles all as specified and as directed
M & L Cleaning of Operation Theater with 100 % Fresh Air type AHU cooling coil by using Bio Enzyme coil cleaner, pressure jet pump so as to improve heat transfer and avoid fungus formations appx room sizes 8 mtr x 8 mtrx 4 mtr as specified and dirtected.
M & L Sanitization of ducts by using fogging machine, Bio-cides so as to avoid fungal/Bacterial formation inside the ducts of AHU units/AHU rooms by using with permissable chemicals with suitable equipments complete all as specified and as directed.
Supply and fixing plastic mesh heavy duty, mesh size less than 10 mm X 10 mm for cooling tower with necessary fixing arrangements all as specified and as directed.
M & L for Welding/cutting of MS Pipe/Rail/MS flanges etc at various locations of AC Plants including with all necessary tools and equipements all as specified and directed.
Supply and fixing of cooling tower fan blade upto capacity 30 TR suitable in existing CT fan hub with suitable length (approx 300mm to 450mm) and size with aluminium alloy material with necessary nuts, bolts, and washers complete all as specified and directed.
Supply and fixing of cooling tower fan blade upto capacity 35 TR to 100 TR suitable in existing CT fan hub with suitable length (approx 300mm to 450mm) and size with aluminium alloy material with necessary nuts, bolts, and washers complete all as specified and directed.
Supply and fixing of water flow /pressure differential switch, 5-15 Amp, complete all as specified and directed.
Dismantling old cooling coil from AHU unit of capacity upto 40 TR by disconnecting refrigerant gas/chilled water pipe line and supply and fix new cooling coil of same size and capacity existing at site including connections, all fabrication works and testing and all as specified and as directed.
M&L for dismantling of ceiling suspended concealed FCU 3 TR of Model No MKT3-1200G12, 11 KW, 1200 CFM, Blow through type from the site and refixing after servicing of motors and blowers and replacement of cooling coil as per specifications existing at site complete repairs/replacement of damaged parts puff body portion, drain pan including fabrication and supporters work all as specified and as directed.
Supply and fixing digital thermostat complete all as specified and as directed.
M&L for dismantling of old unserviceable 3 way actuator valve from site and supply and fix 3 way actuator valve with connected operation assembly complete set for controlling chilled water flow to cooling coil of AHU.120-140 sec timer ,24V,50Hz including repairs of chilled water pipe line after arresting the leakage if any including complete wiring for successful opearation of the unit of following sizes complete all as specified and directed. (a) upto 25mm
All as per item No. 62 But for size 32mm to 65mm complete all as specified and directed.
All as per item No. 62 But for size 80mm to 100mm complete all as specified and directed.
M&L for FRP lining two layers coating with suitable chemical solution (min two coat) of required quantity after preparation of damaged surface area in pipe lines/cooling tower to make leak proof and matching to existing colour complete all as specified and as directed.
M&L steel structural fabrication works fabricated from structural steel sections including nuts,cable trays,clamps bolts,washers,welding,bending cold or hot,drilling holes for bolts,in any shape or size as indicated or directed and inclusive of one primary coat, one under coat and one finishing coat of paint complete all as specified and directed.
S&F in replacement of PVC heavy grade pipe of size 80mm with drilled holes for water spray distribution line in cooling tower including complete coonection with hub,sprinklers of existing CT fan shaft with all necessary connected arrangements for the smooth functioning of cooling tower complete all as specified and as directed.
M&L for painting of central AC plant of capacity upto 225TR chiller units Ie including compressors,condensors,pumps and motor frames,electric panel board complete including chiller and condensing water pipe lines ( Appx length 2.5m) with two coats of synthetic enamel spray paint of existing colour after preparation of existing surface of each unit complete all as specified and as directed.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .