Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.4 LAccepted-AOC 42 608A PULLOMPARAMBIL HOUSE MANDAKARA ROAD KOCHI 682 018 | ERNAKULAM | KERALA | 682018 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹47.1 L+₹4,452.25 (0.09%)Rejected-AOC KATTUPADATH H AZHEEKAL PO VYPEEN 682508 | KOCHI | ERNAKULAM | KERALA | 682508 | L2 | Rejected-AOC Rejected | |
| 3 | L3₹52.0 L+₹4.9 L (10.5%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹52.1 L+₹5.1 L (10.7%)Rejected-AOC KURUPPAMPARAMBIL PERUMPADAPPU PALLURURHY P O ERNAKULAM KERALA 682006 | ERNAKULAM | KERALA | 682006 | L4 | Rejected-AOC Rejected |
Tender Value
Refer Docs
EMD Value
₹1.1 L
Closing Date
1 Apr 2023, 6:00 pmClosed
Shri D C Sharma IDSE CWE(NW) KOCHI
CWE(NW) KOCHI
SPECIAL REPAIR TO SERVANT QUARTERS OF HOUSE NO. 13KB, 121KB, 333KB, 501KB AND 532KB AT KATARI BAGH AND SPECIAL REPAIRS TO CONVERSION OF OLD ALUMINIUM WIRING TO COPPER WIRING
2023_MES_583085_1
CWE(NW)/KOCHI/81347
Open Tender
Civil Works
Item Rate
270 days
KOCHI
As per NIT
6 documents required · 6 mandatory
₹1,000
GE(NW) KOCHI
₹1.1 L
Yes
26 Jun 2023
25 Feb 2023
3 Apr 2023
25 Feb 2023
1 Apr 2023
18 Mar 2023
Amount
Taking down cement plastered on Brick/Concrete wall and ceiling including racking out joints, hacking for key, scrubbing down with water complete all as specified and as directed . Note: The quoted rate shall be deemed to be inclusive of disposal of material to outside MD land as directed by Engineer in charge
M& L for rendering 8 mm thick CM 1:4 with approved water proofing compound over backing coat of 12 mm thick in CM 1:6 using liquid WPC fair surfaces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed. Note:- WPC shall be measured and paid seperately.
M & L for 5 mm thick rendering in cement mortar 1:3 on fair faces of of ceiling surfaces finished even and smooth complete all as specified and as directed .
M&L for rendering 10mm thick on brick or concret wall surfaces with cement mortar (1:6) finished even and smooth without using extra cement complete all as specified and as directed .
Demolition of Brick/block or stone masonry in cement mortar or lime mortar complete all as specified and directed . Note:- The rate quoted rate shall be deemed to be inclusive of disposal of material to outside MD land as directed by Engineer in Charge
M& L for Pre-cast cement concrete block masonry with solid blocks, exc. 10 cm in width and setting in mortar 1:6, Type C1, 1:3:6 (using 20mm graded stone aggregate), complete all as specified and as directed.
Demolition of reinforced cement concrete any description any position not otherwise specifically provided for complete all as specified and as directed. Note:- The rate quoted rate shall be deemed to be inclusive of disposal of material to outside MD land as directed by Engineer in Charge
M&L for RCC 1:2:4 type B1 using 20mm graded aggregate for foundations incl rafts,footings, foundation beams, plinth beams, bases for columns etc basement slabs complete all as specified and as directed .
M&L for RCC 1:2:4 type B1 using 20mm graded aggregate for Columns, piers, pillars and struts complete all as specified
M&L for RCC 1:2:4 type B1 using 20mm graded aggregate for beams, cantlivers, lintels etc complete all as specified
M&L for RCC 1:2:4 type B1 using 20mm graded aggregate for roof slab all as specified.
Use and waste of form work to flat rough finished surfaces sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter all as specified
Use and waste of Formwork flat rough finished surfaces to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. all as specified
Use and waste of Formwork square, rectangular, or polygonal rough finished surfaces to sides of pillars, posts, struts, piers, columns and stanchions all as specified
Use and waste formwork flat rough finished surfaces to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick for rough finished surfaces of concrete (Horizontal or sloping) complete all as specified and as directed .
M&L for TMT bars in reinforcement 10mm dia and over including cut to length , bend to required shape , cranking/hooking ends if necessary and binding with 0.9mm dia MS wire annealed or welding so as to secure the bar firmly in position/required shape complete all as specified and as directed.
M&L for TMT bars 5mm dia and over and including 10mm dia in stirrups, spacers and binders etc , cut to length, bent to shape required, including cranking bending spirally for hooping for coloumns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed
M&L for TMT bars in reinforcement 6 to 8mm dia and over including cut to length , bend to required shape , cranking/hooking ends if necessary and binding with 0.9mm dia MS wire annealed or welding so as to secure the bar firmly in position/required shape complete all as specified and as directed .
M&L for Liquid water proofing compound complete all as specified and as directed .
M&L for preparation of new decorated surfaces of ceiling and applying three coat of white wash complete all as specified and as directed .
M&L for preparation of new decorated surfaces of new wall surface and applying three coat of white wash complete all as specified and as directed .
M&L for preparation of old decorated surfaces of walls including cornices (plastered or unplastered) and applying two coat of white wash complete all as specified and as directed .
M&L for writing letters of figures (BLOCK, ROMAN, ITALIAN OR INDIAN) n exc 30cm high all as specified and directed by Engr in Charge. Note : Writing shall be done with thick paint so that they stand out boldly.
M&L preperation of new decorated surfaces of walls (plastered or unplastered) including cornices and applying two coat of cement base paint over a coat of priming with alkaliresistant priming paint complete all as specified and as directed .
M/L preperation of old decorated surfaces of walls (plastered or unplastered) including cornices and applying one coat of cement base paint complete all as specified and as directed .
Taking down chowkats with shutters (without taking off shutters from the frame) exceeding 1.5 Sqm but not exceeding 4 Sqm complete all as specified and as directed .
Taking down chowkats with shutters (without taking off shutters from the frame) not exceeding 1.5 Sqm complete all as specified and as directed .
Cutting holes in brick wall built in cement mortar, depth of embedded exceeding half brick and not exceeding one brick and making goof dismantled portion in cement concrete 1:2:4 type B1 for inserting hold fast complete all as specified and as directed .
Supply and fix mild steel hold fast, clamps plain angle cleats and similar small articles confirming Fe-400 complete all as specified and as directed .
Supply and fix 2nd class hard wood plain, solid, straight chowkat and frames, wrought framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and as directed .
S&F 2nd class hard wood 30mm thick glazed,gauged and skelton window/ventilator shutters open rebated and prepared to receive glass gauze etc(without sash bars) edges of framing plain,chamfered or rounded fitted with cut and mitred beads for securing glass,gauze etc size of members of shutters as specified in SSR part I section 8 clause 8.24(b).
Supply and fix 2nd class hard wood 35mm thick glaze/gauged skeleton door shutters open rebated and panelled to receive glaze/gauge (without sash bars) edges of framing plain chamfered or rounded fitted with cut and mittered beads for securing glass etc sizes of members of shutters and specified in SSR part 1 section clause 8.24(a) complete all as specified and directed..
Supply and Fix 2nd class hard wood 35mm thick factory made Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete complete all as specified and as directed .
Supply and fix aluminium alloy wire cloth 0.45 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with aluminium wire staples complete all as specified and as directed .
All as per item No 34 here-in-before but fixed in repair complete all as specified and as directed .
Hacking out old broken glass (any thickness size, quality or description) from wooden frames glazed with putty or fitted with beads not exceeding 1.50 Sqm complete all as specified and as directed .
S&F Sheet glass ordinary quality 4.00 mm thick and glazing with oil putty / beads in squares not exceeding 0.5 Sqm in each pane complete all as specified and as directed .
Supply and fix 4.00mm thick frosted glass pin head type and glazing with oil putty / beads in squares not exceeding 0.5 Sqm in each pane complete all as specified and as directed .
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with .S. Square tube, suppling & fixing in opening complete all as specified and as directed .
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing.
Supply and fix aluminium anodised barrel tower bolt extruded section of 150 mm long complete all as specified and as directed .
Supply and fix aluminium anodised barrel tower bolt extruded section of 125 mm long complete all as specified and as directed ..
Supply and fix 300mm long aluminium alloy anodised sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and as directed .
Supply and fix butt hinges 100mm size stainless steel complete all as specified and as directed .
Supply and fix butt hinges 75 mm size stainless steel complete all as specified and as directed .
Supply and fix extruded aluminium alloy handles fabricated type anodised 150 mm size complete all as specified and as directed .
All as per item No 46 here-in-before but 100mm size complete all as specified and as directed .
Dismantling of floor hearth or wall tilling tiles including CM bedding (but not backing) and disposing the rubbish off the premises out of MD land complete all as specified and as directed .
Material and labour for non skid coloured ceramic tiles 7 to 8 mm thick square/rectangular area of each tiles exceeding 0.06 Sqm but not exceeding 0.11 Sqm in floor etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the tiles including provision of CM screed 15 mm thick in CM (1:6) complete all as specified and as directed .
M&L in Glazed ceramic tiles in vertical surfaces Glazed ceramic tiles in vertical surface 300x450x 7-8mm thick mm thick as dado's/skirting including provision of backing coat 10 mm thick in CM (1:4) complete all as specified and as directed ..
Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc complete all as specified and as directed . Note:- Rate quoted shall be deemed to be inclusive of disposal of rubbish out of MD land premises
M&L 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, win dow-cills, cooking plat forms and like in cement mortar (1:4) including point ing in white cement (1:2) us ing marble dust with admix ture of pigment to match with shade of granite over 10mm thick screed bed in cement mortar 1:3 complete all as specified and as directed.
Rounding to edges of stone slabs one edge, of any situations complete all as specified and as directed .
Dismantling of MP tiles or similar tiles in roof covering complete all as specified and as directed .
Dismantling timber scantlings 40 Sq cm over in section for unframed work in fillets, rails, posts, rafters, purlins etc, in unframed works complete all as specified and as directed.
S&F for Pre-painted galvalume aluminium zinc coating GI based corrugated tile profile steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as inroof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed .
S&F Roof trusses (framed) confirming to Fe 410W, trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. complete all as specified and as directed .
M&L for Preparation of new steel surfaces and applying two coats of anti corrosive paint over a coat of appropriate primer complete all as specified and as directed .
M&L for rendeing 10 mm thick on concrete/ brick surfaces as in roof in CM 1:3 including WPC as per manufacturer's instrs finished even and smooth complete all as specified and as directed . Note: WPC shall be measured and paid seperately
Supply and fix in repair anodised aluminium alloy curtain rod 25 mm dia with fixing brackets, stops, rollers etc complete all as specified and as directed . Note:- One pair of end brackets of same colour as that of curtain rod on each opening shall be provided .
S & F in repair vitreous china squatting pan “ORISSA PATERN” of size 580 mm x 440 mm, white, with integral foot rest (excluding flushing cistern and flush pipe) including single trap spun casted 60 cm long fix in asian eposy mortar connection to trap and to flushing pipe, anti syphonage pipe etc and making good to floor complete all as specified and as directed .
Supply only PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including MS brackets 10 Ltrs capacity including flush pipe PVC connections etc complete all as specified and as directed .
Supply and fix in repairs vitreous China wash hand basin of size 580 x 450 mm white, flat back with and including waste fittings brass chromium plated 32 mm with long and fly nut screwed shank excluding taps, waste chain and plug and porcelain stopper but including cast iron brackets complete all as specified and as directed .
Supply only pillar taps, brass, with capston heads, fancy type chromium plated, screwed down high pressure with or without lettered 'Hot' or 'cold' with long screwed shanks and flynuts screwed for 15mm bore iron pipe and fixed complete all as specified and directed.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, E85bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and as directed .
S&F in repair 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed .
All as per item No.68 above but for 75 mm bore complete all as specified and as directed .
M&L 110 mm bore PVC (SWR) bends any radius complete all as specified and as directed .
All as per item No. 70 above but for 75 mm bore complete all as specified and as directed .
M&L 75 mm bore PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and as directed .
Supply and fix tubular towel rail 20mm dia brass chromium plated with brackets fixed in repairs 60cm long complete all as specified and as directed .
Supply and fix in repairs SS gratings circular centre part Square body fixed with white cement alround, 100 mm dia with minimum weight 25 gms complete all as specified and as directed .
Supply and fix in repair door stopper of aluminium alloy body and tongue anodised with hard drawn steel spring fixed in repair in floor, 140mm over length of cover plats complete all as specified and as directed .
S&F in repair stainless steel sink with drainage board made out of 1mm thick sheet kitchen or laboratory with plugs, washers including beding lime cement mortar to dwarf wall or including fixing cantilever brackets fixed to wall and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x160mm including waste coupling 40 mm and waste pipe complete all as specified and directed.
M&L for 75mm thick cement concrete type D2, 1:4:8 (40 mm graded aggregate) as in sub base complete all as specified and as directed .
M & L for chequred cement concrete tile 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurry as in floor with grey cement and filling joints with colour pigment over and including 20 mm thick screed bed in cement mortar 1:6 including dismantling of old tiles complete all as specified and as directed .
M&L for 75mm thick cement concrete type C1 (1:3:6) using 20 mm graded stone aggregate as in plinth Protection complete all as specified and as directed .
M&L for ATT Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron complete all as specified and as directed .
M&L for anti termite Treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete all as specified and as directed .
M&L for ATT At points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 litre/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to centre and sealing the same complete all as specified and as directed .
INTERNAL WATER SUPPLY Supply and fix on wall/concealed on wall high pressure CPVC pipes SDR-13.5 & plain CPVC SDR 11 fittings including all necessay fittings, solvents of size 25 mm dia. complete all as specified and directed.
All as per item No 83 here -in-before but of size 20 mm dia complete all as specified and directed.
Taking up or down steel tubing and connections,including cleaning for refixing or removal to store for schedule of credit 25 mm dia any type complete all as specified and directed.
Taking up or down steel tubing and connections,including cleaning for refixing or removal to store for schedule of credit 20 mm dia any type complete all as specified and directed.
Supply and fixing in repair of Bip cock, CP quarter turn with flange , long nose with wall flange cast copper alloy with crutch or butterfly handle screwed for GI/ CPVC pipe of size 15 mm complete all as specified and as directed .
Supply and fix concealed stop cock regular body,Quarter turn with adjustable wall flange chromium plated with CP cup fancy type of size 20mm and taking down old unserviceble one, complete all as specified and as directed.
Supply and fixing of swivel overhead shower (minimum weight 40 grams) of PTMT any colour with shower arm (minimum weight 40 grams) 15 mm size, 195 mm long with bend of 45 degree ,dia 70 mm with flange for fixing with CPVC pipe and taking down old one,complete and all as specified and as directed .
M/L for cutting chasses on walls floor etc not exceeding 10 cm girth and making good the disturbed surface to match with the existing after removing the existing concealed pipe/laying new pipe, complete all as specified and directed .
Material and labour for cement concrete in foundations, filling and mass concrete type 1:3:6(40mm graded aggregate) complete all as specified and directed.
M & L for CPVC Ball Valve of size 25 mm dia suitable for CPVC pipe incl necessary fittings and taking down old unserviceble vall valve complete all specified and directed.
All as per item No. 92 above but of size 20 mm dia complete all as specified and directed..
Supply and fixing in replacement of Rotational mouldede polyethylene water storage tanks (cylinderical vertical with closed top) hoisted & fixed in position of capacity 500 ltrs incl taking out u/s old one. Make : Sintex (ISI)/ Aquatech
S/F float valve synthetic(PVC) of size 25 mm dia high pressure with polythene ball of size 6" dia and flynut including taking down old one complete all as specified and directed.
INTERNAL ELECTRIC SUPPLY Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. Removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed .
Material and labour for point wiring for one light/fan point with 1.5 sqmm PVC insulated (FRLSH) unsheathed copper conductor multistranded 1100 volts grade controlled by one way switch including 1.5 sqmm PVC (FRLSH) insulated unsheathed copper cable multistrand conductor 1100 volts grade for continuity conductor including connected to common earth dolly drawn through and including rigid PVC conduit medium grade ISI marked concealed of suitable size with all accessories and sunken box of 1.0 mm thick and 60 mm depth pressed steel box factory made for mounting of switch, socket and fan regulator with Hylem sheet including chase cutting and making good to the disturbed surface and matching to the existing finishes specifications complete all as specified and as directed .
All as per item No. 97 here in before but for one bell point controlled by one 5 Amp bell push on independent board complete all as specified and directed.
All as per item No. 97 here in before but for one fan point controlled by one switch & regulator complete all as specified and directed.
All as per item No. 97 here in before but for one 3 pin 5A socket point controlled by one switch on independent board
All as per item No. 97 here in before but for one 3 pin 5A socket point controlled by one switch on same board
All as per item No.97 here in before but with 4.0 Sqmm copper conductor including 4.0 Sqmm copper cable as earth wire for one 6pin 16A socket outlet on independent board.
All as per item No 97 above but with 4 Sqmm copper conductor including 4.0 Sqmm copper cable on earth wire for sheet metal enclosure
Supply and fix ceiling rose surface bakelite 65 x 50 mm 3 terminals 240 volt 50 Hz complete all as specified and directed.
S & F bell push flush type 5 Amps single pole complete all as specified and as directed by engr in charge .
S & F electric bell, AC 230 Volt single pole complete all as specified and as directed .
S & F switch piano flush type single pole one way 5 Amp one way complete all as specified and as directed.
S & F , socket outlet 5 Amps, 5 pin, 2 in 1 complete all as specified and directed .
Supply and fixing in LED lights fitting 1x 20 W, 220V, 120 Lumen/watt ,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceilingrose complete.all as specified and directed .Make: Crompton Cat part No. 20W DIJB 12 LT8 20+LT 820 865 2 or any other Make in the list of manufactures
Supply and fixing in LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC, 75 Lumen/watt decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed . Make: Crompton cat part No. CCS 103 10 65 SL DP or any other make in the list of manufactures.
S&F in Sheet metal enclosure for MCB DB, SPN, 8 ways, double door, with 200 amps rated bus bar, having IP-43 protection including taking down old DB complete all as specified and directed .
S&F in Sheet metal enclosure for MCB DB, SPN, 4 ways, double door, with 200 amps rated bus bar, having IP-43 protection including taking down old DB complete all as specified and directed .
Supply and fixing 5-32 amp rating 240V, 10KA 'B' curve miniature circuit breaker (MCB) of two poles and current carrying capacity in the MCB SPN 20 amp complete with connection testing and commissioning complete all as specified and directed .
Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified and directed .
Supply and fixing LED flood light 35W 230V AC outdoor type with thermal management in multiple optics and equipped with IP 66 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed.
M&L for submain wiring with 2 single core 1.5 Sqmm PVC insulated unsheathed multistranded copper conductor cable 1100V grade drawn through and including PVC rigid conduit concealed wiring including necessary PVC conduit specials including chases cutting complete except beam and RCC roof and one run of 1.5Sqmm PVC insulated unsheathed single core 1100V grade multistranded copper conductor cable as earth continuity conductor and connecting with suitable size thimble complete all as specified and directed . Note:- Two run of 1.5Sqmm size PVC cable,one run of 1.5Sqmm size PVC cable as earth wire and one run of PVC conduit shall be measured as one unit length( For Bell point)
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) all as directed and specified .
S & F in repair fan regulator electronic step type 100 W, 250 Volts complete all as specified and as directed.
Supply & Laying LT cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6 Sqmm 2 core complete all as specified and as directed .
Excavation in trenches not exceeding 1.5 mtrs wide and not exceeding 1.5 mtrs in depth for laying of cables /shafts/well/manholes/pier holes including getting out in soft/loose soil complete all as specified and directed.
Returning filling in including spreading, leveling ,and well ramming, in layers not exceeding 25 cm each layer of soil complete all as specified and as directed .
Removing surplus excavated material from site not exceeding 50 mtrs from starting point and depositing where directed at level not exceeding 1.5 mtr above the starting point complete all as specified and as directed .
Riddle sand cushioning for cables 15cm above the cable and 18cm below the cable complete all as specified and as directed . (Note:- punned thickness shall be measured and paid )
Material and labour for well burnt brick laid flat, for cable protection complete all as specified and directed.
M & L for GI tubing light grade 40 mm bore complete with all fittings like bends, sockets, elbows and fixing clamp of suitable size for passing through cables under the floor, along the wall or along the pole complete all as specified and directed.
S & F modular switch 1 way 6 Amps,1 module complete all as specified and directed.
S & F Modular socket 6 Amps and 2/3 pin combined 2 module complete all as specified and directed.
S & F Modular socket 6 A/16 A - 2/3 pin combined 2 module complete all as specified and directed .
S & F Modualr type switch 16 A One way SP complete all as specified and directed .
S & F Modualr type bell push button flush type 5 Amps complete all as specified and directed .
Supply and fixing of multi music bell AC 230 V single pole complete all as specified and directed .
Taking down existing Light fittings of any type and size and removing to store yard complete all as specified and directed .
Supply and fixing box type, both side connections LED tube light fitting ( Batten) with both side connection LED tube rod 20W, 120 Lumen/Watt with all fixing accessories and connections to the existing electrical system. Make Havells Cat Part No. BATTENT 8 UPTO 1x 22W SSWSSBSWH & CRYSTAL 1213T8DSTC20WLED 865 SGLASS, Crompton Cat Part No. LGT8-20-865-2, Jaquar Cat Part No. LTBLGlX020C or equivalent make mentioned in list of makes
Supply and fix LED flat panel with high brightness with glare free recessed 2 feet by 2 feet 36 Watt 4000k 120 Lumen/watt fitting including all connection all as specified and directed. Make Philips Cat Part No. RC380BLED36S-6500G4L60W60PSUOD equivalent make mentioned in list of makes
S & F LED Mirror light fitting 10 watt 120 Lumen/Watt with connected accessories complete all as specified & directed. Make Philips Cat Part No. BN 021 LED10S 6500 PSU GR S1 or equivalent make mentioned in list of makes
Supply and fixing building security light made up of pressure die cast housing with toughened glass and high power LEDs with option of secondary optic with IP 66 protection of 60 Watt not less than 120 Lumen/Watt. Crompton Cat Part No. Crompton Cat Part No. LSTP-60-CDL-M including suitable GI bracket of 25 mm dia and fixing arrangement on walls all as specified and directed including taking down of existing light fitting of any type and make.
S&F LED Suspended Tubelight fitting 33w , 120 Lumen/Watt 4 ft with taper end ,suspension , end plate & transparent cable for mounting connected accessories complete all as specified and directed. Make:Philips Cat Part No SP811P LED33S-6500 PSD W6L120 OD SI or equivalent make mentioned in list of makes
Supply & fix wall mounted fans AC single phase 230/ 240 V of size 450 mm sweep, 1200 rpm complete including taking down old one all as specified Make V3 of Havells/ CG/Usha . Note:- Old wall mounted fans will be deposited in MES store yard
Supply & fix heavy duty exhaust fans AC single phase 230/ 240 V of size 450 mm sweep, 900 rpm complete including taking down old one all as specified . Make Turbo jet SP of Havells or equivalent make mentioned in list of makes Note:- Old exhaust fans will be deposited in MES store yard
Supply & fix Plastic body exhaust fans AC single phase 230/ 240 V of size 250 mm sweep, 900 rpm complete including taking down old one all as specified Make ventil air DX white of Havells or equivalent make mentioned in list of makes
Taking down unserviceable ceiling fan of 1200mm/1400mm sweep, cutting out the existing burnt out fan motor winding, cleaning the motor slots, rewinding the motor with insulated copper winding wire of existing gauge, baking / heating up the motor to achieve the proper insulation resistance and re-hanging / refixing after repair including applying a coat of synthetic enamel paint (Glossy Finish) with spray gun, marking MES No complete all as specified.
Taking down unserviceable exhaust fan of 300mm sweep, cutting out the existing burnt out fan motor winding, cleaning the motor slots, rewinding the motor with insulated copper winding wire of existing gauge, baking / heating up the motor to achieve the proper insulation resistance and re-hanging / refixing after repair including applying a coat of synthetic enamel paint (Glossy Finish) with spray gun, marking MES No complete all as specified.
Taking down unserviceable Wall mounting fan of 450/300mm sweep, cutting out the existing burnt out fan motor winding, cleaning the motor slots, rewinding the motor with insulated copper winding wire of existing gauge, baking / heating up the motor to achieve the proper insulation resistance and re-hanging / refixing after repair including applying a coat of synthetic enamel paint (Glossy Finish) with spray gun, marking MES No complete all as specified.
S&F fan regulator electronic step type, modular type, 120 W, 2 module complete all as specified and as directed.
M&L Earth continuty or main earthing lead fixed to wall on betten or recess or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required 2mm dia galvanised iorn Strip of size 25x4 mm complete all as specified.
S&F Sheet metal enclosures with socket plug top and MCB' single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole 20 A MCB
Taking down old DBs with MCCB/MCBs of any size complete all as specified and directed .
S&F Sheet metal enclosure TPN for DB's when MCCB's to be used 8 way with 200 amps bus bar double door IP 43 complete all as specified and as directed. Make Havells cat No DHDETHCDOW08 or equivalent make mentioned in list of manufactures
S&F Sheet metal enclosure TPN for DB's when MCB's to be used 6 way with 200 amps bus bar double door IP 43 glazed door complete all as specified and as directed. Make Havells cat No DHDETHCDOW06 or equivalent make mentioned in list of manufactures.
S&F Sheet metal enclosure TPN for DB's when MCCB's to be used 4 way with 200 amps bus bar double door IP 43 glazed door complete all as specified and as directed. Make L & T cat No DBTPN004GD or equivalent make mentioned in list of manufactures
S&F SPN sheet metal enclosure for DB 8 ways Double door complete all as specified and directed .
S&F SPN sheet metal enclosure for DB 4 ways Double door complete all as specified and directed .
S&F MCB 'B' Curve 63 Amp Three pole, 415 Volts, all as specified and directed. Make L&T Cat Part No. BB30630B or Legrand Cat Part No. 408620/ Schneider Cat Part No. A9NIP63B or equivalent make mentioned in list of makes
S&F MCB 'B' Curve 6-32 Amp SPN ,240 Volts all as specified and directed. Make L&T Cat Part No. BB20006B to BB20032B or Schneider or equivalent make mentioned in list of makes
S&F MCB 'B' Curve SP 6 To 32 Amp , 240 Volts, all as specified and directed. Make Schneider Cat Part No. A9N1P06B to A9N1P32B, or L&T Cat Part No. BB10060B to BB10320B / Legrand Cat Part No. 408587-408596 or equivalent make mentioned in list of makes
Taking down old sub main wiring of any size complete all as specified and directed .
M/L submain wiring with 2 single core 4 Sqmm PVC insulated unsheathed multistranded copper conductor cable 1100 volt grade drawn throgh and including PVC rigid conduit concealed wiring inculding necessary PVC conduit specials including chases cutting complete exceapt beam and RCC roof and one run of 4 Sqmm PVC insulated unshearthed single core 1100 volts grade multistranded copper conductor cable as earth continuity condutor and connceting with suitable size thimble complete allas specified and as directed. Note: two run of 4 sqmm size PVC cable , one run of 4 Sqmm size PVC cable as earth wire and one run of PVC conduit shall be measured as one unit length
All as per item No 157 but 2 single core 6 Sqmm with 6 Sqmm earth wire complete all as specified and directed . Note: two run of 6 sqmm size PVC cable , one run of 6 Sqmm size PVC cable as earth wire and one run of PVC conduit shall be measured as one unit length
All as per item No 157 but 2 single core 10 Sqmm with 10 Sqmm earth wire complete all as specified and directed . Note: two run of 10 sqmm size PVC cable , one run of 10 Sqmm size PVC cable as earth wire and one run of PVC conduit shall be measured as one unit length
M&L for sub main wiring with 4 runs of 16 Sqmm (FRLSH) PVC insulated unsheathed multistranded copper conductor cable and 1 run of 16 Sqmm (FRLSH) cable as earth continuity wire and including PVC conduit concealed in wall/floor including cutting chesses and making good distrubed surface to match with existing surface . Note -1. 4 runs of 16 Sqmm sub main wire and one run of 16 sq mm for earthing and cassing capping with accesories shall be measured as one unit.
M&L for sub main wiring with 4 runs of 10 Sqmm (FRLSH) PVC insulated unsheathed multistranded copper conductor cable and 1 run of 16 Sqmm (FRLSH) cable as earth continuity wire and including PVC conduit concealed in wall/floor including cutting chesses and making good distrubed surface to match with existing surface . Note -1. 4 runs of 16 Sqmm sub main wire and one run of 16 sq mm for earthing and cassing capping with accesories shall be measured as one unit.
Taking down old earthing complete all as specified and directed .
M&L for earthing complete with galvanised steel earth plate elctrode 60 x 60cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth strip 25 x 4 mm as earthing lead by means of bolts nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No.point 3 connected to earthing test point all as specified or indicated including testing on completion.
M&L point wiring with 1.5 Sqmm PVC insulated unsheathed FRLSH multi stranded single core copper conductor cable in PVC concealed conduit rigid non metallic (ISI marked) fixed concealed on wall/roof except beam,column and RCC roof including chases cutting ,modular white cover plate flush metal box etc.including 1.5 Sqmm PVC insulated copper conductor as earth continuity wire for One light point controlled by one switch complete all as specified and directed .
All as per item No.164 above but for one fan point controlled by one switch and regulator complete all as specified and directed .
All as per item No.164 above but for one 3pin 5 A socket point controlled by one switch on same board complete all as specified and directed .
All as per item No.164 above but for one 3pin 5 A socket point controlled by one switch on independent board complete all as specified and directed .
All as per item No.164 above one bell point controlled by one switch complete all as specified and directed .
All as per item No. 164 above but with 2.5 Sqmm copper conductor including 2.5Sqmm copper cable as earth wire for one 6 pin 16A socket outlet on independent board complete all as specified and directed .
All as per item No. 164 above but with 4 Sqmm copper conductor including 4.0 Sqmm copper cable on earth wire for sheet metal enclosure complete all as specified and directed .
MS BUILDERS
JKM CONSTRUCTIONS
Albert Rebello and Company
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .