Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.1 LAccepted-Finance GOVT ELECTRICAL CONTRACTOR C VILLAGE HAT PO BAJAURA TEHSIL BHUNTAR DISTRICT KULLU HP 175125 | KULLU | HIMACHAL PRADESH | 175125 | L1 | Accepted-Finance L1 Bidder | |
| 2 | L2₹10.4 L+₹29,959.14 (2.97%)Rejected-Finance | L2 | Rejected-Finance L2 Bidder | |
| 3 | Rejected-Technical VILLAGE SHUKARI P O ROPA TEHSIL SAINJ DISTRICT KULLU HP | KULLU | HIMACHAL PRADESH | 172001 | - | Rejected-Technical Non Responsive | |
| 4 | Rejected-Technical | - | Rejected-Technical Non Responsive |
Tender Value
₹10.0 L
EMD Value
₹20,000
Closing Date
18 Apr 2026, 12:00 pmClosed
EE Electrical Division HPPWD Mandi
EE Electrical Division HPPWD Mandi
SH- Providing Switch gear, LED fixture, Armoured cable and E.I. in Attic Floor, therein
2026_PWD_134078_4
No.PW-MED-TA-Tender/2025-26- 8086-99 Dated- 31.03.2026
Open Tender
Electrical Works
Percentage
365 days
Balichowki, Distt- Mandi
As per SBD
13 documents required · 13 mandatory
₹350
₹20,000
2 Jul 2026
12 Apr 2026
20 Apr 2026
13 Apr 2026
18 Apr 2026
13 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required complete in all respect as per entire satisfaction of Engineer- in- Charge . i) Group A . Make:-Hevells / Finolex / RR Cable /KEI /Grandley/SSK/Polycab. | 30 | Each | - | - |
| 2 | Providing and installation of stationary storage type Electric water heater (Geyser) of various sizes with 8 bar pressure rating Five star BEE rating and safety valve installation by means of expansion-bolts with nuts and washers, including embedding of expansion-bolts in the wall, making good the damages, electrical connections, testing etc. as required complete in all respect as per entire satisfaction of Engineer- in- Charge. i) 10 Liter capacity water heater (Cat-A)Make : Gold Medal / Bajaj / Hevells / Orient /Atomberg | 2 | Each | - | - |
| 3 | Providing and installation exhaust fan of following sizes in the existing opening, Double ball bearing type metal frame including making the hole to suit the size of the above fan, making good the damages, connections, testing and commissioning etc. as required as required complete in all respect as per entire satisfaction of the Engineer in charge. i) Exhaust Fan, Light duty, (Domestic) 300 mm sweep Make : Gold Medal / Bajaj / Hevells / Orient /Atomberg | 22 | Each | - | - |
| 4 | Providing and fixing the louvers/shutters complete with frame for exhaust fan light Duly (Domestic) 300 mm Sweep as required complete in all respect as per entire satisfaction of the Engineer in charge. | 22 | Each | - | - |
| 5Supply and Erection of LED Downlighter (recess) Round/square type with polycarbonate body and diffuser on existing surface/recess including carriage, erection, making connections, testing and commissioning complete in all respects . The fitting shall operate on 140–270 V AC supply with 50 Hz frequency, power factor not less than 0.90, luminaire efficacy ≥85 lm/W and CRI ≥80. The colour temperature shall be 6000K ±10% with working temperature 0°C to +45°C. The electronic driver shall be constant current type with THD <15%, surge protection minimum 2.5 kV, efficiency ≥85% and with under/over voltage protection. The fixture shall comply with LM-79 test from UL/NABL lab and LED make shall be CREE/OSRAM/NICHIA/Philips Lumiled or equivalent having minimum 25,000 burning hours life at 70% lumen maintenance as per LM-80 test report, including 2 years guarantee against manufacturing defects as per entire satisfaction of the Engineer in charge.Make:- bajaj,havells, Goldmedal, panasonic, Philips,Wipro, Changi | |||||
| 5.01 | LED Down Light Lumen output 1020 | 10 | Each | - | - |
| 5.02 | LED Down Light Lumen output 2040 | 2 | Each | - | - |
| 6Supply and Erection of LED Downlighter (Surface) Round/square type with polycarbonate body and diffuser on existing surface/recess including carriage, erection, making connections, testing and commissioning complete in all respects . The fitting shall operate on 140–270 V AC supply with 50 Hz frequency, power factor not less than 0.90, luminaire efficacy ≥85 lm/W and CRI ≥80. The colour temperature shall be 6000K ±10% with working temperature 0°C to +45°C. The electronic driver shall be constant current type with THD <15%, surge protection minimum 2.5 kV, efficiency ≥85% and with under/over voltage protection. The fixture shall comply with LM-79 test from UL/NABL lab and LED make shall be CREE/OSRAM/NICHIA/Philips Lumiled or equivalent having minimum 25,000 burning hours life at 70% lumen maintenance as per LM-80 test report, including 2 years guarantee against manufacturing defects as per entire satisfaction of the Engineer in charge.Make:- bajaj,havells, Goldmedal, panasonic, Philips,Wipro, Changi | |||||
| 6.01 | LED Down Light Lumen output 1020 | 52 | Each | - | - |
| 6.02 | LED Down Light Lumen output 2040 | 18 | Each | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.23 MB
BOQ_198327.xls
BOQ • 0.33 MB
SBD_Gadagushani.pdf
Tender Documents • 4.12 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .