Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.8 LAccepted-AOC 54 KANWALI ROAD DEHRADUN 248001 | DEHRADUN | UTTARAKHAND | 248001 | L1 | Accepted-AOC AOC | |
| 2 | L2₹15.7 L+₹15,772 (1.02%)Rejected-Finance | L2 | Rejected-Finance Rejected being | |
| 3 | L3₹15.8 L+₹22,550 (1.45%)Rejected-Finance 44 NEAR DURGA MANDIR TRIPURI TOABA TRIPURI TOWN PATIALA 147004 PB | PATIALA | PUNJAB | 147004 | L3 | Rejected-Finance Rejected being | |
| 4 | L4₹16.0 L+₹46,340 (2.98%)Rejected-Finance H NO 698 SECTOR 10 PANCHKULA HARYANA 134109 | PANCHKULA | PANCHKULA | HARYANA | 134109 | L4 | Rejected-Finance Rejected being | |
| 5 | L5₹16.5 L+₹93,930 (6.05%)Rejected-Finance | L5 | Rejected-Finance Rejected being |
Tender Value
₹25.0 L
EMD Value
₹49,980
Closing Date
1 Oct 2024, 6:00 pmClosed
GE (N) AMBALA CANTT
GE (N) AMBALA CANTT
CA NO GE(N)AMB-37/2024-25 REWIRING OF INTERNAL ELECTRIFICATION INCLUDING FITTING AND FIXTURES IN OFFRS MD ACCN-I AND OTHER AREA OF SECTOR A OF AGE E/M UNDER GE (N) AMBALA CANTT
2024_MES_671175_1
GE(N)/AMB-37/2024-25
Open Tender
Civil Works
Item Rate
180 days
GE (N) AMBALA CANTT
As per tender document
9 documents required · 9 mandatory
₹500
GE (N) AMBALA CANTT
₹49,980
Yes
9 Nov 2024
3 Sept 2024
3 Oct 2024
3 Sept 2024
1 Oct 2024
17 Sept 2024
3 Sept 2024 - 17 Sept 2024
Amount
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete including all fittings and fixtures such as switches, pendant, lamp holder, socket outlet, etc and removing unserviceable materials from site of work and making good disturbed surfaces of walls, floors with cement mortar and white/colour wash to match with existing surfaces etc complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for point wiring with 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade ISI marked with multi stranded copper conductor drawn through and including medium grade, ISI marked, PVC conduit not less than 20 mm dia with accessories, concealed on wall/ceiling surfaces and including provision of 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade, ISI marked with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box or pressed steel terminal boxes modular type of size/modules as required at site with earth dolly (boxes shall be galvanised or painted with two coats of anti corrosive paint over a coat of red oxide primer both internally and externally) including provision of new covered plate over sunken box for housing the modular switches , modular socket outlets,modular fan regulators etc. for one light/fan/exhaust fan/bell point controlled by one way switch, complete all as specified and as directed by Engineer-in-Charge. Note :- a) .All chases will be cut by chase cutter only b) Switch, socket outlet and fan regulators to be measured and paid for separately .
Description all as per serial item No.02 here-in-before but for One 3 pin, 6 Amps, socket outlet controlled by one switch on independent board, complete all as specified and as directed by Engineer-in-Charge.
Description all as per serial item No.02 here-in-before but for One 3 pin 6 Amps socket outlet controlled by one switch on same board, complete all as specified and as directed by Engineer-in-Charge.
Description all as per serial item No.02 here-in-before but for one socket outlet 16 Amp with 2.50 sq mm PVC insulated, unsheathed cable FRLS-H, 1100 volt grade ISI marked with multi stranded copper conductor along with 2.50 sqmm PVC insulated , unsheathed cable green colour FRLS-H, 1100 volt grade, ISI marked with multi stranded copper wire as earth continuity conductor connected to common earth dolly complete all as specified and as directed by the Engineer-in-Charge.
Description all as per srl item No 02 here-in-before but for one socket outlet 16 Amp with 4.00 sq mm PVC insulated, unsheathed cable FRLS-H, 1100 volt grade ISI marked with multi stranded copper conductor along with 4.00 sqmm PVC insulated , unsheathed cable green colour FRLS-H, 1100 volt grade ISI marked with multi stranded copper wire as earth continuity conductor connected to common earth dolly complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing of modular switch 1 module, single pole, one way 6 Amps flush type, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing of modular switch 1 module, single pole, one way 16 Amps flush type, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing of modular bell push 6 Amp, 1 way, 1 module, 230 volts complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing of modular socket outlet 2/3 pin combined, 6 Amp, one way, two module, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing of modular socket outlet 3/3 pin combined, (6pin), 6/16 Amp, one way, two module, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing as in repair electronic Fan regulator modular 100 watt, 1 module, 230 volts , 50 Hz, AC supply suitable for ceiling fan any type/make/sweep complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in repair calling bell ding dong 230 volt, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing ceiling rose surface type 2/3 terminal polycarbonate, isolated body complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing lamp holder, PVC/polycarbonate type with back plate suitable for batten fittings, complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement LED lamp 9 watt threaded/pin end, warm/cool lamp type as per site requirement suitable for fixing on existing batten/angular holders complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in replacement LED lamp 12 watt threaded/pin end, warm/cool lamp type as per site requirement suitable for fixing on existing batten/angular holders complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing LED lamp Invertor technology 9 watt with 4 hour power back up with efficiency more than 100 lumen per watt,Lithium ion battery complete all as specified and as directed by the Engineer-in-Charge. Cat part No.LED INVERTER LIGHT 10 W B22 CW IP of make Halonix or equivalent in make given in Appx 'B'.
Supply and fixing in repair LED batten fitting 10-12 watt, 2 feet, aluminium housing with electronic driver cool/warm type industrial model complete, connecting with copper conductor flexible cable from ceiling rose to connector of the light complete all as specified and as directed by the Engineer-in-Charge. Cat part No. LUMILINE+ BS10WLED865PCSS of make Havells or equivalent in make given in Appx 'B'.
Supply and fixing in repair LED batten fitting 18-20 watt, 4 feet, aluminium housing with electronic driver cool/warm type industrial model complete, connecting with copper conductor flexible cable from ceiling rose to connector of the light complete all as specified and as directed by the Engineer-in-Charge. Cat part No. LUMILINEPLUSNEOBS20WLED830SPCSSIND of make Havells or equivalent in make given in Appx 'B'.
Supply and fixing in repair, indoor decorative LED tube light fitting box type 18/20 watt with electronic driver, opal diffuser, high efficient aluminium housing body suitable for LED tube, high efficient, AC 220-240 volts, 50 Hz including 18/20 Watt LED tube rod luminaries environment friendly, high efficient, T8 with aluminium extrusion heat sink and connecting with copper conductor flexible cable from ceiling rose to connector of the light complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing PVC casing caping of 1 inch size complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in repair, LED surface mounted bulk head luminaries 8-10 watt with min 800 lumen, industrial model, IP 65, aluminium housing, surge protection including driver and LED lamp, etc. complete with all accessories, connecting with copper conductor flexible cable from ceiling rose to connector of the light complete all as specified and as directed by the Engineer-in-Charge. Cat part No. HEXAFT10WLED857SSYMBOPC of make Havells or equivalent in make given in Appx 'B'.
Supply and fixing in repair, 9/12 watt LED light fitting wall mounting fixture (sketch type) including B-22 LED lamp compact and energy efficient epoxy powder coated luminaire and connecting with copper conductor flexible cable from ceiling rose to connector of the light complete including removing unserviceable light fittings complete all as specified and as directed by the Engineer-in-Charge. Cat part No. HLWB-01-B22 of make Halonix or equivalent in make given in Appx 'B'.
Supply and fixing in repair, LED Bldg Security Light Fittings of capacity 20 -25 watt made up of die cast aluminium housing with black epoxy powder coating with cover heat resistance glass safety input voltage range 170 to 270 volts, industrial model with IP-65 protection and other connected accessories including electronic driver and making electrical connection, complete all as specified and as directed by the Engineer-in-Charge. Cat part No.ENDURASUNDOWNSL25WLED765PASYBOTGIHD of make Havells or equivalent in make given in Appx 'B'.
Supply and fixing in repair, service bracket of mild steel pipe 25 mm bore medium grade of length 0.70 mtr fixed to wall with two clamps made of 20 x 3 mm mild steel flat minimum 15cm long, 4 nos 8mm dia bolts with nuts and washer and suitable reducer for connecting fitting to GI pipe as required at site including two coats of synthetic enamel paint over one coat of red oxide primer on mild steel work complete all as specified and as directed by the Engineer-in-Charge.
S & F LED Bollard 8-10 watt, IP-65 , 6500 K luminaire made of pressure die cast aluminium housing and clear glass , 240 volt, 50HZ, AC supply , complete with all accessories including electronic driver, internally pre wired including connecting with three core flexible copper conductor cable from Electric Supply Source to connector of the light as in repair complete all as specified and as directed by the Engineer-in-Charge. Cat part NoBAMBOOBLS8WLED830PSYMTOPC of make Havells or equivalent in make given in Appx 'B'.
S & F LED post top luminaire IP-65 made of pressure die-cast aluminium housing & clear glass 240 volt, 50HZ, AC supply complete with all accessories,suitable and including B22 LED lamp 15 watt, internally pre wired including provision of 3 core PVC flexible copper conductor from electric supply source to connector of the light, including disconnecting and taking down existing light fitting and removing old unserviceable fitting complete all as specified and as directed by the Engr-in-charge. Cat part No. HLPT-04-B22 of make Halonix or equivalent in make given in Appx 'B'.
Supply and fix as in repair modular PVC sheet/cover plate 3 way suitable for fixing switch/socket/fan regulators etc on existing MS boxes of any make as per site requirement including removing unserviceable items, complete all as specified and as directed by the Engr-in-charge.
Supply and fix as in repair modular PVC sheet/ cover plate 4 way suitable for fixing switch/socket/fan regulators etc on existing MS boxes of any make as per site requirement including removing unserviceable items, complete all as specified and as directed by the Engr-in-charge.
Supply and fix as in repair modular PVC sheet / cover plate 6 way suitable for fixing switch/socket/fan regulators etc on existing MS boxes of any make as per site requirement including removing unserviceable items, complete all as specified and as directed by the Engr-in-charge.
Supply and fix as in repair modular PVC sheet / cover plate 8 way suitable for fixing switch/socket/fan regulators etc on existing MS boxes of any make as per site requirement including removing unserviceable items, complete all as specified and as directed by the Engr-in-charge.
Supply and fix as in repair modular PVC sheet / cover plate 12 way suitable for fixing switch/socket/fan regulators etc on existing MS boxes of any make as per site requirement including removing unserviceable items, complete all as specified and as directed by the Engr-in-charge.
Disconnecting electric/water supply connection, taking down carefully geyser of any capacity, deposting to MES store yard for repair and refixing the same after repair at desired location complete all as specifed and directed by Engr-in-Charge.
Supply & replacing inner tank made from 1mm thick stainless steel sheet for geyser of 25 Ltr capacity including taking out old unserviceable inner tank of any description complete all as specified and as directed by the Engr-in-charge.
S & fixing heating element cup or triangle type of 2 KW as required at site for geyser of any make and any descriptions including taking out old unserviceable heating elements complete all as specified and as directed by the Engr-in-charge.
S & F thermostat switch for geyser of any type ISI marked including taking out old unserviceable thermostat switch complete all as specified and as directed by the Engr-in-charge.
S & F geyser inner tank assembly suitable for geyser capacity of 25 Ltr including taking out old unserviceable tank assembly complete all as specified and as directed by the Engr-in-charge.
Supply and fixing in repair, heating element, 2 KW, having inbuilt thermostat as required at site for geyser of any make and descriptions complete, all as specified and as directed by the Engineer-in-Charge.
S&F brass chromium plated non return valve 15mm bore with air lock release arrangement including taking out old unserviceable non return valve, complete all as specified and as directed by the Engr-in-charge.
S & replacing metal clad socket & top as per existing socket and top including taking out old unserviceable metal clad socket top, complete all as specified and as directed by the Engr-in-charge.
S & F in replacement flexible cable PVC insulated and sheathed, 3 core, circular multi stranded copper conductor of 2.5 Sqmm including removing unserviceable cable, complete all as specified and as directed by the Engr-in-charge.
S&F brass connection pipe 450mm long having wire mesh coating over it with brass nuts and washers suitable for connecting geysers inlet and outlet with GI tubings including taking out old unserviceable connections of any description all as specified and as directed by Engr-in-charge.
S&F top plug 15 Amp, 3 pin including taking out old unserviceable plug top complete all as specified and as directed by the Engr-in-charge.
S&F indicating lamp green/red in colour 230 volts as per existing make including removing unserviceable items,complete all as specified and as directed by the Engr-in-charge.
Supply and fix MCB SP, 6-32 Amps, 240 volt,10 KA , 'B' curve as per site requirement including removing old unserviceable MCB complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix MCB SPN 32 Amps, 240 volt,10 KA , 'B' curve as per site requirement including removing old unserviceable MCB complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix MCB SPN, 63 Amps, 240 volt,10 KA , 'C' curve as per site requirement including removing old unserviceable MCB complete all as specified and as directed by the Engineer-in-Charge.
S & F in repair MCB four pole and neutral 415 Volts, 63-100 Amps, 16 KA, 50 Hz thermal adjustable type complete all as specified and directed by the Eng-in-charge.
Supply and fix MCB SP, 40-63 Amps, 240 volt,10 KA , 'B' curve as per site requirement including removing old unserviceable MCB complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing as in repair heavy duty wall mounting fan 400 mm sweep with corrosion resistant PVC body, minimum noise, operation and maintenance free design, totally enclosed, highly efficient, heavy duty motor with pressure die cast aluminium rotor mounted on two ball bearings, aerodynamically contoured blades, rigid frame , 1400 RPM, PVC blades and testing complete all as specified and as directed by Engineer-in-Charge.
Supply and fix sheet metal enclosure Vertical triple pole & neutral(VTPN) IP-54 with MCCB 100 Amp, 16 KA, 415 volts, 4 way with 200 Amp rated bus bar flush /surface mounting double door duly grouted in solid block wall or on wooden board in and including lugs/thimbles duly crimped for connection including making smooth the disturbed surface including removing old unserviceable enclosure complete all as specified and as directed by the Engr-in-charge.
Supply and fix sheet metal enclosure triple pole & neutral(TPN) IP-54 with MCB 63 Amp, 16 KA, 415 volts, 4 way with 200 Amp rated bus bar flush /surface mounting double door duly grouted in solid block wall or on wooden board in and including lugs/thimbles duly crimped for connection including making smooth the disturbed surface including removing old unserviceable enclosure complete all as specified and as directed by the Engr-in-charge.
S&F single pole and neutral enclosure with a two pin and earth plug and socket 20 Amp complete with and including one single pole MCB.20 Amp, 10 KA 'B' curve including removing old unserviceable enclosure complete all as specified and as directed by the Engr-in-charge. Cat part No.811955 of make Indo Asian or equivalent in make given in Appx 'B'.
Supply and fix sheet metal MCB DB SPN 4 way with 200 Amps rated bus bar single pole and neutral with double door IP-54 fixed on wall duly grouted in solid block wall or on wooden board in and including copper lugs/thimbles duly crimped for connection, including making smooth the disturbed surfaces including removing old unserviceable enclosure complete all as specified and as directed by the Engr-in-charge. Cat part No.811824 of make Indo Asian or equivalent in make given in Appx 'B'.
Supply and fix sheet metal MCB DB SPN 8 way with 200 Amps rated bus bar single pole and neutral with double door IP-54 fixed on wall duly grouted in solid block wall or on wooden board in and including copper lugs/thimbles duly crimped for connection, including making smooth the disturbed surfaces including removing old unserviceable enclosure complete all as specified and as directed by the Engr-in-charge. Cat part No.811825 of make Indo Asian or equivalent in make given in Appx 'B'.
Supply and fix sheet metal MCB DB SPN 12 way with 200 Amps rated bus bar single pole and neutral with double door IP-54 fixed on wall duly grouted in solid block wall or on wooden board in and including copper lugs/thimbles duly crimped for connection, including making smooth the disturbed surfaces including removing old unserviceable enclosure complete all as specified and as directed by the Engr-in-charge. Cat part No.811828 of make Indo Asian or equivalent in make given in Appx 'B'.
Supply and fixing as in repair, MCCB, 4 pole, 63 Amp, 415 Volts, 16 KA , fixed type including fixing arrangement, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing as in repair, MCCB, 4 pole, 100 Amp, 415 Volts, 16 KA , fixed type including fixing arrangement, complete all as specified and as directed by the Engineer-in-Charge.
S & laying as in repair sub main wiring with two run of 4 sqmm PVC insulated , unsheathed cable FRLS-H,1100 volts grade ISI marked with multi stranded copper conductor and one run of 4 sqmm PVC insulated , unsheathed cable FRLS-H, 1100 volt grade ISI marked multi stranded copper conductor as earth continuty conductor connected to common earth dolly including concealed on wall/ceiling surfaces in and including PVC conduit medium grade ISI marked of adequate size for housing the wires complete all as specified and as directed by the Engineer-in-Charge. Note: (i) Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. (ii) Three runs of cable and one run of PVC conduit shall be measured and paid as one unit length.
S & laying as in repair sub main wiring with two run of 6 sqmm PVC insulated , unsheathed cable FRLS-H,1100 volts grade ISI marked with multi stranded copper conductor and one run of 6 sqmm PVC insulated , unsheathed cable FRLS-H, 1100 volt grade ISI marked multi stranded copper conductor as earth continuty conductor connected to common earth dolly including concealed on wall/ceiling surfaces in and including PVC conduit medium grade ISI marked of adequate size for housing the wires complete all as specified and as directed by the Engineer-in-Charge. Note: (i) Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. (ii) Three runs of cable and one run of PVC conduit shall be measured and paid as one unit length.
S & laying as in repair sub main wiring with four run of 10 sqmm PVC insulated , unsheathed cable FRLS-H,1100 volts grade ISI marked with multi stranded copper conductor and one run of 10 sqmm PVC insulated , unsheathed cable FRLS-H, 1100 volt grade ISI marked multi stranded copper conductor as earth continuty conductor connected to common earth dolly including concealed on wall/ceiling surfaces in and including PVC conduit medium grade ISI marked of adequate size for housing the wires complete all as specified and as directed by the Engineer-in-Charge. Note: (i) Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. (ii) Four runs of cable and one run of PVC conduit shall be measured and paid as one unit length.
Supply and laying or fixing or passing through pipe 1100 volts grade heavy duty 2 core, 10 sq mm nominal cross section cable with PVC insulated aluminium conductor multistranded served with an inner sheathing of PVC tape and overall PVC sheathed in service connection, including disconnecting and taking down old U/S existing cable complete all as specified and as directed by the Engineer-in-Charge.
Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5mtr below the normal ground level connected to galvanised earth wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron.Earth wire protected by GI pipe 15mm bore(medium grade) and connected to earthing test point as directed and as specified and shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 40 cm x 40cm x 5cm reinforced with 8mm dia TMT bars @ 15cm c/c both ways with one handle for lifting made out of 8mm dia bar, funnel, wire mesh, 20mm dia GI pipe medium grade for watering, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil and testing as in repair complete all as directed by Engineer-in-Charge and earth testing on completion .
Note:- Amount of credit of Rs. 73,238.00 for retrieved materials is mentioned in Schedule of Credit Page No.83 & 84 of tender documents in pdf form which will be deducted offline while acceptance of tender.
Goyal Engineers (BID ID -3108220)
Mohinder Pal and Sons (BID ID -3099364)
bharat contrectors (BID ID -3110112)
S.R. Constructions (BID ID -3103582)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .