Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.1 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER, HENCE ACCEPTED | |
| 2 | L2₹49.7 L+₹2.5 L (5.29%)Rejected-Finance | L2 | Rejected-Finance NOT LOWEST BIDDER | |
| 3 | L3₹49.9 L+₹2.8 L (5.84%)Rejected-Finance | L3 | Rejected-Finance NOT LOWEST BIDDER | |
| 4 | L4₹50.4 L+₹3.2 L (6.86%)Rejected-Finance | L4 | Rejected-Finance NOT LOWEST BIDDER | |
| 5 | L5₹50.7 L+₹3.5 L (7.44%)Rejected-Finance | L5 | Rejected-Finance NOT LOWEST BIDDER |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
4 Feb 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER
DADWARA KOTA RAJASTHAN 324002
SPL REPAIR TO BLDG NO P-355 (02 QTRS), P-4 AND CERTAIN OFFRS MESS AT MIL STN KOTA
2024_MES_685331_2
8897E8
Open Tender
Civil Works
Item Rate
183 days
MIL STN KOTA
AS PER TENDER DETAILS
8 documents required · 8 mandatory
₹500
Yes
GE Kota
₹96,000
Yes
15 Feb 2025
23 Jan 2025
11 Feb 2025
23 Jan 2025
4 Feb 2025
30 Jan 2025
Amount
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises
Demolition of stone slabs and tiles of any description or thickness laid, bedded and pointed in any mortar in floors, aprons etc.complete all as specified and as directed.
Taking down cement plaster on stone/brick/concrete surfaces including racking out joint, hacking for key, scrubbing down with water complete all as specified and as directed.
M&L for joint free non skid ceramic coloured tiles, 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles, laid over and including 15 mm thick screed bed in CM 1:6, complete all as specified and directed.
M&L for joint free non skid matte finish ceramic coloured tiles, 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles, laid over and including 15 mm thick screed bed in CM 1:6, complete all as specified and directed.
M&L for joint free non skid matte finish ceramic coloured tiles, 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm fixed on vertical surfaces as skirting, set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles, laid over and including 10 mm thick rendering in CM 1:4 backing, complete all as specified and directed.
M & L for 20 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like over and including 15 mm thick cement mortar (1:6) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite incl cutting hole of 25mm dia for gas pipe if required complete all as specified and as directed.
M & L for rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and as directed.
Material and labour for plastering 15 mm thick on stone masonry surfaces or other than fair faces of brick work or on one side of lathing (on vertical surfaces) in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and as directed.
Material and labour for plastering 15 mm thick (in two coats of 10 mm and 5 mm thick) on fair faces of brick work or concrete surfaces (on vertical surfaces) mixed with and including water proofing compound as per manufacturer instructions in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified and as directed.
M & L for preparation of newly plastered surface of wall and applying two coats of oil bound distemper complete all as specified and as directed.
M & L for complete removal of existing treatment of wall and applying two coats of oil bound distemper complete all as specified and as directed.
Taking down wooden chowkhats or frames with shutters (without taking off shutters from the frames) area not exceeding 1.50 sqm each complete all as specified and as directed.
Supply and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension (extruded section profile) 48x40 mm (tolerance ± 1 mm), with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete all as specified by the manufacturer and as per directions of Engineer-in-charge & all as per specifications & drawing as applicable to item 08169 given in SSR Part – II (2020).
Supply and fixing factory made uPVC white colour Two track two panels sliding glazed window upto 1.50m height made of (small series) frame 52 x 44 mm & sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area of window upto 1.75 sqm) comprising of uPVCmulti-chambered frame, with inbuilt roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, complete all as specified and directed by Engineer-in-Charge and all as per specifications and drawings as applicable to item 08180 given in SSR Part–II (2020). (Glass or wiremesh shall be paid separately) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.
Supply and fix Aluminium deco grill Cat No DG-104, 10 mm thick ,cut to required size/shape and fixed in position with and including stranded aluminium frame of F section of size 23.04x15.3x1.4mm thick all as per manufacturer instructions complete all as specified and as directed.
Supply & fix toughened (tempered) safety glass as per IS 2553 (Part-1): 2018, flat, tinted 4 mm thick, fixed with steel, aluminium, metal frame work in windows/ doors/ partitions/ ventilators including rubber beading complete all as specified and as directed.
S & F stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and as directed.
S & F factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum comp ressive strength of 58 N/mm2 , modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge and as per specification & drawing as applicable to item 08100A given in SSR Part – II (2020). (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. Make:-Rajshri/Sintex/Accucel/Duraplast
S&F for factory made 30mm thick 100% Solid WPC ( Wood polymer Composite) Laminated Flush Door Shutter of required size comprising of virgin PVC resin of K Value 57-60 ( Suspension Grade ), Calcium Carbonate and natural fibers ( Wood Powders/ rice husk/ wheat husk ) and Non toxic additives, made from Extrusion process WPC foam sheet Single Extruded ( Inner ) with having minimum density not less than 650 kg/cbm, having good screw holding capacity ( Screw Withdrawal strength of 2000 N ( Face ) & 1100 N ( Edge ), Minimum Compissive of 50 N/mm2, Modulus of elasticity 850N/mm2 and resistance of spread of flame of Class A category with Property of being Termite/ Borer Free.Water/ Moisture Proof and Fire Retardant. WPC to be Laminated with PVC foil of minimum 14 microns thick of approved design pasted on both faces of shutter and fixinng stainless Steel butt hinges of required size with necessary full body threaded star headed counter sunk SS Screws. All as per direction of Engineer In-Charge, Material test certificate and authentication should be compulsory provided by the manufacturing company : For WC/Bathroom/Toilet/Kitchen/Balcony Doors. Make:-Rajshri/Sintex/Accucel/Duraplast
S & F brass skeleton 375 mm long tower bolts with cast brass plate and staples and rolled or drawn brass bolt complete all as specified and directed.
S & F brass alloy handle, fabricated type, 150 mm size, nickel chromium plated finish as per service grade number 4 of IS 1068: 1993 complete all as specified and as directed.
S & F 100 mm medium weight mild steel butt hinges made out of cold reduced low carbon steel or hot rolled carbon steel as per IS 1341: 1992 complete all as specified and as directed.
S & F 25 mm dia decorative powder coated aluminium curtain rods with decorative ball type side brackets complete all as specified and as directed.
S & F in renewal of 15 mm wall mixture three in one with complete accessories complete all as specified and directed. Make :- CERA cat part No F1001411/ Jaquar cat part No QQP 7273PM/ Hindware cat part No F 740022 or techno commercially equivalent make specified in PS.
S & F in renewal of 15mm bore mixture valve chromium plated fancy type for wash hand basin centre hole,swan neck fixed to iron pipe with necessary fittings complete all as specified and as directed. Make :- CERA cat part No F1003461/Jaquar cat part No QQP 7167 BPM/ Hindware cat part No F 740009 or techno commercially equivalent makes specified in PS
S & F in renewal 15mm bore wall mounted sink mixture three in one with complete accessories complete all as specified and directed. Make- Cera Cat part no F1017501/ Hindware Cat No F740023/ Jhonson Cat No JT1235A or techno commercially equivalent make as specified in PS.
S & F in renewal frameless bathroom LED touch sensor mirror wall habnging of size 600 x 450 mm incl all necessary fittings complete all as specified and directed.
S & F brass, chromium plated toilet paper holder complete all as specified and as directed.
S & F stainless steel soap dish weight not less than 150 gm each fixed to plugs with chromium plated brass screws complete all as specified and as directed.
S & F in renewal of Bib taps 15mm dia, chromium plated, long body, with CP flange all as per fixed in renewal of complete all as specified and as directed. Make :- CERA cat part No G 1017152 /Jaquar cat pat no VGP-81037/ Hindware cat part No F 740011 or techno commercially equivalent makes specified in PS.
S&F in renewal of floor mounted EWC with integrated vitreous china flushing cistern of 10 ltrs capacity, single unit of size 670 x365 x 735 with S or P trap incl slim soft close seat cover, as per CERA cat Part No S 1013222VS (Charm 6D) / Prayag cat Part No 4375, Johnson Cat part NO G 3907PW0103 or techno commercially equivalent makes specified in PS complete set and making all necessary connections complete all as specified and directed.
S&F in renewal of vitreous china counter wash hand basin white with flat back of size 550x400 x 1600 mm, exclulding chain and plug, taps and porcelain stoper but incl PVC waste pipe of 32 mm bore, suitable size of waste fittings, one pair of 600 mm long cast iron brackets as per Cera cat part No S 2020102 FG, / Johnson cat part No P 7312PW 50505 / Prayag cat part No 4724 or techno commercially equivalent makes specified in PS complelete all as specified and directed.
S & F in renewal of health faucet with 1 meter SS braided connection pipe complete all as specified and as directed. Make :- CERA Model-F 8030105AB (ABS)/ Jaquar ALD-565,/ Johnson cat part no J f8082A or techno commercially equivalent Makes as specified in PS.
"S & F in renewal of towel ring of CP fixed with and including CP brass screws and wooden / plastic cleats (min wt 90 gms) all as for kitchen complete all as specified and as directed. Make :- Cera cat part No 5013115CH /Jaquar cat part No ACN-1121N / Hindware cat part No F 580003 or techno commercially equivalent Makes as specified in PS."
S & F in renewal of towel rail 600mm long of CP fixed with screws and wooden/plastic cleats (Minimum weight 190gms) complete all as specified and as directed. Make :- CERA Cat No.F5013104CH/Jaquar cat part No ACN-1111 SM/ Hindware cat part No F 450024 or techno commercially equivalent makes specified in PS.
"S & F in renewal of shower rose 125/150 mm size brass chromium plated with swivel joints including fixing steel pipe or unions with all necessary fittings complete all as specified and as directed. Make :- CERA cat part No F7020111AB/ Hindware cat part No F 160142/ Johnson cat part No JF 803899 or techno commercially equivalent Makes as specified in PS."
S & F health faucet with jet spray, 1.5 metre long, cast copper alloy, nickel chromium plated finish, 15 mm bore, 100 mm long with 1.5 metre long stainless steel shower hose and mounting device attached to wall complete all as specified and as directed.
M & L for PVC connections 15 mm size with PTMT nuts of length 450 mm complete all as specified and as directed.
S & F in renewal of sinks with drainage board made of stainless steel 1 mm thick sheet kitchen or laboratory with plugs, washers and 40 mm nominal size, copper alloy, nickel chromium plated finish waste fittings with including silicone sealant; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipes overall size 915 mm X 460 mm bowel size 410 mm X 330 mm X 160 mm complete all as specified and as directed.
S & F in repair Kitchen stainless steel plate rack of size 120 cm x 90 cm x 18 cm with partition for small/ large plates fabricated out of 24 gauge stainless steel sheet including necessary fixing / fittings & making good the existing surfaces complete all as specified and as directed.
Taking up or down 15 mm bore of steel tubing and connections, including cleaning for refixing or removal to store or taken on schedule of credit complete all as specified and as directed.
Taking up or down 20 mm bore of steel tubing and connections, including cleaning for refixing or removal to store or taken on schedule of credit complete all as specified and as directed.
Supplying & fixing to walls and ceilings or laid in floors 15 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
Supplying & fixing to walls and ceilings or laid in floors 20 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc. complete all as specified and as directed.
M & L for brick work with fly ash bricks of class designation 7.5 and non-modular size as per IS 12894: 2002, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6 complete all as specified and as directed.
M & L for precast cement concrete louvers and jallies, 35 mm thick (measured solid) in cement concrete M15 (Nominal mix) using 12.5 mm nominal size coarse aggregate including all mouldings but excluding frame and fixed in position using cement mortar (1:6) including taking down old unserviceable jallies complete all as specified and as directed.
Taking out deposited mud, silt, waste etc. form drains or channels width of bed not exceeding 90 cm and removing upto 500 metre and deposited where directed at a level not exceeding 1.5 metre from the starting point complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose/ hard/ dense soil complete all as specified and as directed.
Removing excavated material (soils) not exceeding 50 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
M & L for preparation of newly plastered surface of wall and applying two coats cement base paint over one coat of primer complete all as specified and as directed.
Demolition of cement concrete (unreinforced) of any description and in any position, above or below ground floors, not otherwise specifically provided for complete all as specified and as directed.
Taking down existing treatment of any description such as PCC padding, lime concrete, mud phuska etc. and any numbers of layers upto any thickness from roof including scraping and roughening old by picking, sweeping clean and washing down and removing debris outside MD land complete all as specified and as directed.
M & L for brushing neat cement slurry with 3.0 kg of cement per square meter complete all as specified and as directed.
M & L for cement concrete M15 (Nominal Mix) using 12.5 mm nominal size coarse aggregate in roof kerbs or mud stops,padding, rounded or chamfered on edges complete all as specified and as directed.
Material & labour for rendering 15 mm thick in cement mortar 1:4 over RCC Roof mixed with water proofing compound @ 3% by weight of cement or manufacturer instruction complete all as specified and as directed. (Note;- water proofing compound shall be measured and paid separately as supply only)
M&L for cleaning of roof slab including picking, sweeping clean and washing down with water to remove dust, dirt etc and Supply and fix APP polymeric water proofing membrane, minimum 3mm thick and weighing not less than 3.0 Kg/Sqm, black finish reinforced with non-woven polyester matt, with a thermo fusable finish laid over cold applied bituminous primer conforming to IS 3384 @ of 0.40 Kg/Sqm torching overlaps with a propane or a butane gas torch, with a overlap of 75mm at the sides and 100mm at the ends and sealing including applying a coat of cold emulsion bituminous primer all as per manufacturer’s instructions, complete all as specified and directed. Note: (i) Coved fillets in PCC(1:2:4) type B-0 using 12.5mm graded stone aggregate, of radius 75mm shall be provided at the junction of roof and parapet wall/mumty/chimney/other vertical surfaces and thereafter surface painted with hot paving bitumen of Grade 30/40 confirming to IS-73, [email protected] Kg/Sqm over a coat of cold applied bituminous primer conforming to IS:3384 @ 0.40 Kg/Sqm. (ii) Polymeric membrane shall be taken to a height of 45cm (minimum) and then inserted inside the groove of parapet wall of brick masonry and shall be finished by a membrane flushing. (iii) The waterproofing treatment shall be got carried out by the manufacturer or their authorized applicators. (iv) In case of stone masonry parapet wall etc a groove of size 25mmx25mm (minimum) shall be made in coved fillet at the junction of roof and parapet wall/mumty Chimney/other vertical surfaces and polymeric membrane inserted in groove and sealed with paving bitumen. (v) Cost of above aspects is deemed to be included in quoted rates.
Supply only liquid water proofing compound complete all as specified and directed.
M&L for joint free non skid ceramic coloured tiles, 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles, laid over and including 15 mm thick screed bed in CM 1:6, complete all as specified and directed.
M&L Glazed ceramic coloured tiles on vertical surfaces 350x 250x7 mm/450X350X7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match, laid over and including 10 mm thick rendering in CM 1:4 backing, complete all as specified and directed.
M & L for cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate as in floor 25 mm thick in sub base for laying tiles, pavings, floorings etc. complete all as specified and as directed.
M & L for machine cut Kota stone slab flooring 18 to 20 mm thick over and including cement screed bed of 15 mm thick in cement mortar 1:6, laid and jointed with grey cement slurry, mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
M & L for 18 to 20 mm thick machine cut Kota stone in risers of steps, skirting, dado and pillar laid on and including backing layer of 10 mm thick in cement mortar 1:4, laid and jointed, pointed with grey cement slurry, mixed with pigments to match the sheds including rubbing and polishing complete all as specified and as directed.
M & L for 75 mm thick plain cement concrete M10(Nominal Mix) using 40 mm nominal size graded stone aggregates, laid in alternate panel, finished surface even and fair including filling in position with 85/25 industrial grade bitumen mix filler of proportion 80 kg of hot bitumen, 1 kg of cement and 0.25 cubic metre of coarse sand as in plinth protection complete all as specified and as directed.
Material and labour for plastering 10 mm thick on fair faces of brick work or concrete surfaces on ceilings in cement mortar 1:3 finished even and fair complete all as specified and as directed.
Preparation of newly plastered surfaces on walls and applying three coats of white wash complete all as specified and as directed.
Preparation of old decorated surfaces on ceilings and applying two coats of white wash complete all as specified and as directed.
M & L for complete removal of existing treatment and preparation of surfaces and applying two coats of cement base paint complete all as specified and as directed.
Taking down wooden chowkhats or frames with shutters (without taking off shutters from the frames) area exceeding 1.50 sqm but not exceeding 4.00 sqm each complete all as specified and as directed.
M & L for anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed.
M & L for anodised aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading screws etc. complete all as specified and as directed.
M & L for anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150 mm long (1 no.). hinges type B-21 100 mm long (2 no.) suitable handle (1 no.) complete all as specified and as directed.
S & F double action concealed type floor springs (hydraulically regulated) made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel top cover, governing pivot made of brass, other parts made of mild steel heavy duty complete all as specified and as directed.
S & F in renewal of exposed type hydraulically regulated door closers, universal closer, bottle type (type A), Designation No. 3, suitable for 61 kg to 80 kg mass of doors & 851 mm to 1000 mm width of door, aluminium alloy non porous body and black plate, aluminium alloy piston or pack piston/ pillion, anodized finish not be less than Grade AC 15 of IS 1868 : 1996 with transparent anodic film as per IS 3564: 1995 complete all as specified and as directed.
S & F mortice lock, vertical type, cast brass, 4 levers, vertical type, 75 mm size, finished smooth fixed in position complete all as specified and as directed.
S & F hot rolled medium and high tensile structural steel of grade E 250 quality C conforming to IS 2062: 2011 as in framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and as directed.
M & L for 35 mm thick, timber species of super group and durability class I as per IS 12896: 1990 and first grade as per IS 1003 (Part-1): 2003, factory made, glazed and skeleton shutters, open rebated and prepared to receive glass, wire gauze, etc. (without sash bar), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc., sizes of members of shutters as specified in SSR Part-I section 8 Clause 8.24 (a) complete all as specified and as directed.
S & F flush door shutters, 30 mm thick, solid core of block boards construction, MR grade, commercial type with stiles, rails and lipping of timber as given in Group 2A and Group 2B of Annex B of IS 2202 (Part 1): 1999, both sides face panels of plywood as per IS 710: 2010, internally lipped complete all as specified and as directed.
S & F steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and as directed.
S & F steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded complete all as specified and as directed.
Supply & fix sheet glass, ordinary quality, 3 mm thick and glazed with oil putty or fixed with beads in square not exceeding 0.5 Sqm in each pane complete all as specified and as directed.
S & F hot rolled medium and high tensile structural steel of grade E165 as per IS 15911: 2010 as in framed work such as grills, grating, etc., with ends of bars of shouldered and/or riveted, or forged into spikes, framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework water tanks and similar work complete all as specified and as directed.
M & L for preparation of new or previously untreated wood or wooden surfaces, of any description, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
Preparation of newly or previously untreated steel surface of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed.
Supply and fix solid PVC door frames of size 50 mm x 47 mm made out of 5 mm thick plain colour PVC sheet reinforced with MS square tube all as per specification & drawing complete all as specified and as directed.
S & F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of mild steel tubes for top & bottom rails. Mild steel frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and wood grain printed PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the mild steel frame welded / sealed to the stiles & rails with 5 mm X 15 mm PVC sheet beading and decorative PVC beading of 10 mm X 10 mm (90⁰) used instead of exposed portion of PVC sheet beading and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing complete all as specified and as directed.
S & F aluminium alloy sliding door bolts with hasp, staple and fixing clips of sheets, or extruded sections and fixing bolts and sliding bolts of extruded sections of aluminium alloy, 300 mm long, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed.
S & F extruded aluminium alloy handle, fabricated type, 150 mm size, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed.
S & F aluminium barrel tower bolts with barrel and bolt of extruded sections of aluminium alloys, 200 mm long, dia of bolt 12 mm, anodized finish not be less than Grade AC 10 of IS 1868 : 1996 with transparent anodic film complete all as specified and as directed.
S & F floor door stoppers made out of aluminium alloy pressure die casting body and tongue with hard drawn steel wire spring, overall length of cover plate 150 mm, 4.5 mm thickness of cover plate, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996, suitable for 40 & 45 mm thickness of door shutter, fixed in floor complete all as specified and as directed.
S & F extruded aluminium alloy handle, fabricated type, 100 mm size, anodized to a bright natural, mat finish not be less than Grade AC 10 of IS 1868 : 1996 complete all as specified and as directed.
S & F aluminium barrel tower bolts with barrel and bolt of extruded sections of aluminium alloys, 150 mm long, dia of bolt 12 mm, anodized finish not be less than Grade AC 10 of IS 1868 : 1996 with transparent anodic film complete all as specified and as directed.
S & F in renewal of vitreous china squatting pan, 'Orissa" pattern, size 580 mm X 440 mm white with ‘P’ or ‘S' trap, front or back inlet and integral foot rests, any pattern and including fixing bolt, connector to flush pipe, lime concrete bedding and making connections to flush pipe, connector to branch pipe and anti syphonage pipes etc. including sealing the joints and making leak proof using sealant complete all as specified and as directed.
S & F brass chromium plated shower rose 125 mm size with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and as directed.
S & F in renewal of vitreous china wash down water closet (pedestal pattern), white including thermoplastic seats and covers of grade 2 type, flat with hinging device of bronze or brass with nickel chromium plating, fixing bolt, connector to flush pipe and making connections to flush pipe, connector to branch soil pipe and anti syphonage pipes etc. including sealing the joints and making leak proof using sealant complete all as specified and as directed.
S & F wash basins, vitreous china, white, flat back, size 550 mm X 400 mm with and including cast iron brackets (embedded in wall upto 110 mm depth with and including cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate or fixing on wall with and including rawl plug and screws), 32 mm nominal size, copper alloy, nickel chromium plated finish waste fittings, including painting of fittings and brackets, sealing gap between wall and basin with silicone sealant, cutting and making good the walls wherever required and connecting to supply pipes, including waste pipes, waste fittings etc. with silicone sealant complete all as specified and as directed.
S & F in renewal of PVC low/high level flushing cistern white 10 liters capacity including PVC inlet pipe with brass check nuts low level full both sides along with PVC flush pipe 32 mm dia jointed to WC and handle including brackets fixed in renewal of complete all as specified and as directed. Note:- Rate includes removing existing flushing system of CI or any other quality including brackets.
S & F overhead shower 100 mm dia Round Shape Single Flow (ABS Body Chrome Plated With grey Face Plate) With Rubit Cleaning System as per Jaquar Model No. OHS-1989 or equivalent of hindware including shower arm 20 mm dia & 300 mm long round shape with 90º Bend as per Jaquar Model No. SKU: SHA-CHR-479L300 or equivalent of hindware complete all as specified and as directed.
S & F in renewal of 15 mm nominal size, nonrising spindle type fancy bib taps as per IS 8931: 1993 made of cast brass including Knob, knob components, divertor & components, nickel-chromium plated finish complete all as specified and as directed.
S & F in renewal of 15 mm nominal size, nonrising spindle type fancy stop valves as per IS 8931: 1993 made of cast brass including Knob, knob components, divertor & components, nickel-chromium plated finish complete all as specified and as directed.
S & F 15 mm nominal size, nonrising spindle type fancy pillar taps as per IS 8931: 1993, cast copper alloy body with knob, knob components, divertor & components, nickel-chromium plated finish complete all as specified and as directed.
S & F brass chromium plated tubular towel rail, 20 mm dia, D type, 60 cm long between flanges complete all as specified and as directed.
Dismantling water tanks capacity exceeding 250 litres but not exceeding 500 Litres and removing to store complete all as specified and as directed.
S & F rotational moulded polyethylene tripple layer water tanks (vertical cylindrical with close top) as per IS 12701: 1996 of 500 litres capacity hoisted and fixed in position including provision of 20 mm /15 mm dia medium grade GI pipe for connecting inlet, outlet, over flow and washout pipes complete all as specified and as directed.
S & F ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe of 20 mm size, minimum weight 210 grams complete all as specified and as directed.
Demolition and breaking up existing pipes of internal dia 100 mm, set in cement mortar or any type complete all as specified and as directed.
S & F 110mm dia PVC(SWR) single socketed soil waste pipes in any length with rubber ring joints laid in trenches or in floor complete all as specified and as directed.
S & F PVC (SWR) bends of any radius of 110 mm dia with access door complete all as specified and as directed.
S & F PVC (SWR) vent cowl of 110 mm dia complete all as specified and as directed.
Supply and fix PVC SWR Nahani/ Floor trap plain with grating including jointing with solvent cement, dia of outlet 75 mm, water seal minimum 50 mm complete all as specified and as directed.
M & L for PVC (SWR ) gully trap 125/110 mm with grating or without grating and jointing with solvent cement and fixed in position complete all as specified and as directed including cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
M & L for cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate in lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs, slab staging for water tanks, filling of pressed steel door frame, fixing of hold fasts and the like including weathering, slightly rounded or chamfered angles and throating including necessary formworks complete all as specified and as directed.
M & L for cement concrete in foundation, filling and mass concrete in M7.5(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M35 grade conforming to IS 15658: 2021 made by block making machine with strong vibratory compaction, of approved size, design & shape, cast in rubber mould, glossy finish of approved colour, laid in required colour and pattern over and including 30 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. complete all as specified and as directed.
Demolition of cement concrete(unreinforced) in ground floors and paving not exceeding 15 cm thickness (below or above ground level) complete all as specified and as directed.
Excavating in post holes (or similar holes) each not exceeding 0.5 cum, getting out in soft/ loose soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering and removing surplus soil to a distance not exceeding 50 m and making good surface complete all as specified and as directed.
M & L for cement concrete in foundation, filling and mass concrete in M10(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
Dismantling of wall/ ceiling boards(fibre pulp insulation etc.) or insulations boards /slabs/blankets any thickness including cover fillets of any description including all snap grids and hanging arrangements complete all as specified and as directed.
Providing & Fixing of Armstrong galvanised Vector Micro perforated metal ceiling consisting of 600 mm X 600 mm Vector tiles of galvanized steel in 0.5 mm thickness with micro perforation having hole diameter as 1.5 mm and open area of 10%. The tile shall be powder coated Armstrong Global White colour of 60-80 microns painted to a minimum of 120 gsm (both sides combined) galvanizing to be laid on Armstrong grid systems with 24 mm wide T - section flanges colour white having rotary stitching on the Main Runner, 1200 mm & 600 mm Cross Tees. Back side of the tile will have Soundtex fleece hot pressed to achieve NRC upto 0.7. The tile edges should feature detailing like the Spring Kerf, Access Kerf & the reverse tegular Non Engaging Edge to hide the grid, creating a 6 mm shadow reveal and also provide downward mountability without any tools. The Vector edge tile shall feature security tabs to prevent unauthorized access. The tile shall be laid on Armstrong Prelude 38 with 24 mm wide T - section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 38 mm and a load carrying capacity of 15.0 kgs/ sqm (as per standard installation layout mentioned below) & pull out strength of 100 kgs. The T Sections have a Galvanizing of 90 grams per sqm and need to be installed with Suspension system of Armstrong make.
Dismantling of plain or corrugated steel sheeting, any gauge, thickness including any pattern roof coverings complete all as specified and as directed.
M & L for pre-painted hot-dip aluminium-zinc alloy metallic coated corrugated (profile) steel sheet, any pattern corresponding to IS 15965:2012 of durability class 3, atmospheric classification category C3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in roof covering/ wall cladding fixed with self drilling screws and washers as specified including end and side lap, necessary scaffolding and safety measures at any floor complete all as specified and as directed.
S & F hot rolled medium and high tensile structural steel of grade E 250 quality C conforming to IS 2062: 2011 as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. complete all as specified and as directed.
M & L welded steel wire fabric supplied and fixed complete to wood or steel members weight not exceeding 4.00 kg /sqm complete all as specified and as directed.
S&F 18 mm thick HDWPC (High density wooden plastic composite) kitchen cupboard/door shutter board one side colour/white laminated and other side decorative as in modular kitchen/cabinets fixed with minifix hardware where ever required including edge band 22 mm wide .80 m thick of matching colour on exposed surface of board fixed with polymaster adhesive including trimming edges of edge band to true line of thickness of board by manual trimmer fixed to wall etc complite all as specified and directed. Make:- Pearl wood or equivalent in Rajshri plastiwood/Greenply/Century PLywood.
S & F mild steel continuous hinge, 40 mm nominal size, 1 mm thick, type IV as per IS 3818: 1992, bright finish and fixed to cupboard shutter complete all as specified and as directed.
S & F aluminium alloy hasps and staples, type -1, safety type, size 125 mm, anodized finish not be less than Grade AC 10 of IS 1868 : 1996 including fixing with screws complete all as specified and as directed.
S & F ball catches with 8 mm dia steel ball, and brass body and striking plate including letting in and fixed complete all as specified and as directed.
Material & labour for rendering 20 mm thick in cement mortar 1:4 over RCC Roof mixed with water proofing compound @ 3% by weight of cement or manufacturer instruction finished even and fair complete all as specified and as directed. (Note;- water proofing compound shall be measured and paid separately as supply only)
Supplying & applying fibre reinfoced UV resistant elastomeric liquid applied water prooving & heat reflective coating with acrylic polymers and polyester/glass fibres over a coat of primer as per manufecture's instructions after scrapping and properly cleaning the surface to remove loose particles with wire brushes complete all as per specified and directed . Note: The waterproofing treatment shall be got carried out by the manufacturer or their authorized applicators.
M & L for cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate as in floor 40 mm thick finished even and fair complete all as specified and as directed.
Preparation of newly plastered surfaces on ceilings and applying three coats of white wash complete all as specified and as directed.
Preparation of old decorated surfaces on ceilings and applying one coat of white wash complete all as specified and as directed.
M & L for complete removal of existing treatment of wall and applying two coats of oil bound distemper over one coat of alkali resistant primer complete all as specified and as directed.
M&L for preparation of newly plastered surfaces of wall and applying two coats of exterior emulsion paint over a coat of primer complete all as specified and directed. Note :- (i) All coats including primer to be applied with fully automatic airless spray machine of paint application with a flow speed of minimum 1 ltr per minute having a pressure of 3300 PSI / Manual application Allow 6-8 hrs to dry the surface in subsequent coats of paint (ii) Make should be dulux weather shield max/Nerolac Excel Everlast 12/Asian paint ultima protek / Berger weather coat long life 15 or Techno commercially equivalent makes specified in PS complite all as specified and directed.
Material and labour for complete removal of existing treatment for preparation of old surface of wall and applying two coats of exterior emulsion paint over a coat of primer complete all as specified and directed. Note :- (i) cracks of wall plaster should be filling upto 5 bars of positive hydrostatic pressure on vertical walls without any dilution with forced coverage not more than 3.5 sqm / ltr as per manufacturer's instructions. (ii) All coats including primer to be applied with fully automatic airless spray machine of paint application with a flow speed of minimum 1 ltr per minute having a pressure of 3300 PSI / Manual application Allow 6-8 hrs to dry the surface in subsequent coats of paint. (iii) Make should be dulux weather shield max/Nerolac Excel Everlast 12/Asian paint ultima protek / Berger weather coat long life 15 or Techno commercially equivalent makes specified in PS complite all as specified and directed. (iv) decorated treatment on wall / ceiling / chajja by scrapping with trucare wall sander : L-01/H-01 (having mechanical vacuum mechanism) having RPM not less than 1500, sanding pad of 80 Grit having dia of 7"/9" to make the surface free from dust, loose paint etc. or equivalent makes viz Xpress sanding machine having suction vaccum bag or by manual scrapping tools where mechanical removal is not possible and filling cracks, holes etc
Taking down wooden door shutter area exceeding 1.00 but not exceeding 2.00 sqm each complete all as specified and as directed.
Taking down and refixing in same opening wooden door shutter area exceeding 1.00 but not exceeding 2.00 sqm each including resecuring or easing & adjusting complete all as specified and as directed.
M & L for 35 mm thick Iind class hard wood, factory made, glazed and skeleton shutters, open rebated and prepared to receive glass, wire gauze, etc. (without sash bar), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc., sizes of members of shutters as specified in SSR Part-I section 8 Clause 8.24 (b) complete all as specified and as directed.
S & F flush door shutters, 35 mm thick, solid core of block boards construction, MR grade, commercial type with stiles, rails and lipping of timber as given in Group 2A and Group 2B of Annex B of IS 2202 (Part 1): 1999, both sides face panels of plywood as per IS 710: 2010, internally lipped complete all as specified and as directed.
M & L for powder coated aluminium window and ventilator shutters, side hung type without sash bars, aluminium section (thickness of powder coating not less than 50 micron) weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, powder coated aluminium snap beading, screws, powder coated aluminium fittings such as peg stays 150 mm long (1 no.). hinges type B-21 100 mm long (2 no.) suitable handle (1 no.) complete all as specified and as directed.
S & F brass alloy handle, fabricated type, 125 mm size, nickel chromium plated finish as per service grade number 3 of IS 1068: 1993 complete all as specified and as directed.
S&F 18 mm thick HDWPC (High density wooden plastic composite) board one side colour/white laminated and other side decorative as in shelf and partition of cabinet complete all as specified and directed by Engineer-in-Charge.
S&F in renewal of factory made pressed steel cupboard shutters alongwith frame, frame made of 1.25 mm thick PBI sheet and shutter made of 1.00 mm thick PBI sheet with 6 Nos 3.15 mm thick and 100 mm long steel hinges per shutter, godrej pattern locking arrangement with 12 mm dia vertical rod and lock with duplicate key & chrome finish handle, duly spray painted in factory with two coats of synthetic enamel paint over a coat of red oxide zinc chromate primer, complete with fastener, hold fast etc as required at site, complete all as specified and directed. (Total width including frame shall be measured for payment purpose).
Refixing 20 mm bore of steel tubing and connections in new or old positions (walls, ceilings, floors, etc.) complete all as specified and as directed.
S & F PVC (SWR) bends of any radius of 75 mm dia with access door complete all as specified and as directed.
S & F PVC (SWR) branch piece single (single Y) equal or unequal suitable for 75 mm dia complete all as specified and as directed.
S & F PVC (SWR) branch piece single (single Y) equal or unequal suitable for 110 mm dia complete all as specified and as directed.
S & F PVC (SWR) vent cowl of 75 mm dia complete all as specified and as directed.
M & L for cement concrete M7.5 (Nominal Mix) using 40 mm nominal size graded crushed stone aggregate 100 mm thick in sub base for laying tiles, pavings, floorings etc. complete all as specified and as directed.
Taking down carefully without point wiring by unscrewing from boards/ outlet boxes, fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and regulators, etc. for reuse at site or carrying to the store (To be measured only when found serviceable in all respects complete for reuse)
Taking down main switch/MCB/MCCB/MCB DB/ MCCB DB/ sheet metal enclosure by disconnecting the electric supply including MCB/MCCB/Cut out etc. any type and size complete all as specified and as directed.
Taking down old unserviceable submain wiring 1.5 sqmm or 2.5 sqmm or 4 sqmm or 6 sqmm or 10 sqmm aluminium/copper conductors any number including batten/conduit/ casing capping including removing materials to store for keeping in safe custody or for taking credit and making good disturbed surface to match the existing surface complete all as specified and as directed.
M & L for point wiring for one light or one fan or one exhaust fan controlled by one switch complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including heavy mechanical stresses class and -5 temperature class PVC casing/capping of suitable size as required at site including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed.
M & L for point wiring for one bell/ buzzer point controlled by one push button on the same board with other switches or on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including heavy mechanical stresses class and -5 temperature class PVC casing/capping of suitable size as required at site including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed.
M & L for point wiring for one 3 pin/ 5 pin 5 Amps socket outlet on the same board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including heavy mechanical stresses class and -5 temperature class PVC casing/capping of suitable size as required at site including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed.
M & L for point wiring for one 3 pin/ 5 pin 5 Amps socket outlet on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including heavy mechanical stresses class and -5 temperature class PVC casing/capping of suitable size as required at site including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed.
M & L for point wiring for one 3 pin/ 5 pin 15 Amps socket outlet on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 2.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including heavy mechanical stresses class and -5 temperature class PVC casing/capping of suitable size as required at site including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 2.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed.
S & F switch, 6A, single pole, one way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A complete all as specified and as directed.
S & F switch socket combination with (3 pin and 3 pin) having two earthing pins, combined socket outlets, 6A & 16A, 240 V, AC, 50 Hz with earthing contact, rewirable, pillar type terminal, normal protection, unenclosed, without Shutter, Flush type, Design B and switch, 16 A, single pole, one way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A complete all as specified and as directed.
S & F 3 pin socket outlets, 6A, 240 V, AC, 50 Hz with earthing contact, rewirable, pillar type terminal, normal protection, unenclosed, without Shutter, Flush type, Design B complete all as specified and as directed.
S & F Bayonet plastic lamp holder, 2 A, 250 V, ordinary, backplate, non-switched, unenclosed, without T marking, B22d complete all as specified and as directed.
S & F ceiling roses, 6A, 240 V, terminals for the connection of live, neutral and protective earthing conductors, surface type, intended to support mechanical loads by means of flexible cord, having provision for the connection of switch wiring, screw type terminal, made out of Polyamide or hornbean complete all as specified and as directed.
S & F step type electronic fan regulator, capacitor type, 100 watt, 240 volts, 50 Hz, single phase, flush type on the existing phenolic laminated sheet complete all as specified and as directed.
S & F call bell suitable for single phase, AC, 240 volts complete all as specified and as directed.
S & F bell push, 6A, single pole, one way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A complete all as specified and as directed.
Supply and fix concealed sub main wiring complete with and including two Nos single core PVC insulated, unsheathed flexible conductor FR-LSH cables 6 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through and including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories and fixed on walls and 6 sqmm one No single core copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable for earthing and connected to common earth dolly complete all as specified and as directed. (Note 1- Two runs of 6 sqmm cable, one run of 6 sqmm cable and one run of conduit shall be measured and paid as one unit length. Note 2- Cost of cutting chase and making good shall be measured and paid separately.)
S & F LED tube fitting 4 feet 20 watts including tube with high power LEDs as light source and electronic driver complete all as specified and as directed.
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed.
S & F double door MCB Distribution board of sheet metal enclosure, triple pole and neutral, 4 way with 200 Amps rated bus bar, 415 volt, IP42 protection grade and fixed with MS hold fast and grouted in wall with M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed.Make- Legrand Ekinox3 series/ Schnieder Easy 9 series/ ABB Cat No ISYP021604C0001 or equivalent technocommercially equivalent make as specified in PS.
S & F single door MCB Distribution board of sheet metal enclosure, single pole and neutral, 8 way with 200 Amps rated bus bar, 240 volt, IP42 protection grade and fixed with PVC plug and screws and grouted in wall with M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed. Make- Legrand Ekinox3 series/ Schnieder Easy 9 series/ ABB Cat No ISYP011608C0001 or equivalent technocommercially equivalent make as specified in PS.
S & F miniature circuit breakers (MCB), two pole with one protected pole (SPN), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated current 6 A to 32 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed.
S & F miniature circuit breakers (MCB), single pole (SP), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage single phase, rated frequency 50 Hz, Rated current 6A to 32 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed.
S & F miniature circuit breakers (MCB), four pole with three protected pole (TPN), unenclosed, panel board type, screw type terminals for external copper conductors, C-type instantaneous tripping, rated voltage 415 V three phase, rated frequency 50 Hz, Rated current 100 A, Rated Short circuit capacity 10 kA, any type of fixation, Protection IP 20 complete all as specified and as directed.
S & F in renewal of sheet metal enclosure with socket plug top and MCB single pole and neutral enclosure with two pin & earth plug and socket complete with MCB SP 20 Amps 240 volts complete all as specified and as directed.
S & F exhaust fan, AC, 50 Hz, single phase, 230 V, 300 mm sweep, 4 pole, heavy duty, metal body, 4 Nos blades, Insulation Class A, ISI marked including capacitor to ensure power factor more than 0.9 including louvers and all fixing accessories including making hole for fixing of exhaust fan of suitable size and making good the disturbed surface as per existing complete all as specified and directed.
S & F isolator TPN, 63 A, 415 V complete all as specified and as directed.
S & F ceiling fan, AC, 50 Hz, single phase, 230 V, 1200 mm sweep, minimum air delivery 210 m³ per minute, minimum service value 6 m³ per minute per watt, 3 Nos metal blades protected with corrosion resistance paints, with brushless DC motor having electronic controllers that use sensors, ISI marked including capacitor to ensure power factor more than 0.9, five star rating as per Bureau of Energy Efficiency including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
Taking down geyser of any capacity and type and refixing the same after completion of plastering works including provision of nuts, bolts etc. complete all as specified and as directed.
M & L in renewal of PVC connections 15 mm size with PTMT nuts of length 600 mm complete all as specified and as directed.
Supply and fix in renewal exhaust fan made of sturdy engineering plastic (having excellent impact and abrasion resistance, light weight and resistance to colour change), complete with louvers shutter, voltage 230V, 50 Hz, speed 1200 rpm, 250 mm sweep size, 5 number of blades, air delivery 860 cubic metre per hour, copper winding complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning in renewal of cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 4 core, nominal cross sectional area of main conductor 25 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in any type of soil complete all as specified and as directed.
Supply & spreading in trenches dry river sand cushioning to underground cable in trenches including spreading, levelling, hand punning down complete all as specified and as directed. Note:- Depth of sand cushioning will be measured after punning down and levelling the sand properly.
M & L for laying of bricks locally available sub class 'B' bricks, non-modular sizes as per IS 1077: 1992 for cable protection cover laid flat and dry in trenches over the cable perpendicular to the direction of cable complete all as specified and as directed.
Supplying & laying in trenches 40 mm nominal bore, light grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
M & L in renewal for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 4.0 mm dia galvanised mild steel wire by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c both ways with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 20 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed.
M & L for point wiring for one 3 pin/ 5 pin 15 Amps socket outlet on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 2.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including heavy mechanical stresses class and -5 temperature class PVC casing/capping of suitable size as required at site including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed.
M & L for concealed point wiring for one light or one fan or one exhaust fan controlled by one switch complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be measured and paid separately.)
M & L for concealed point wiring for one 3 pin/ 5 pin 5 Amps socket outlet on the same board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be measured and paid separately.)
M & L for concealed point wiring for one 3 pin/ 5 pin 5 Amps socket outlet on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be measured and paid separately.)
M & L for concealed point wiring for one 3 pin/ 5 pin 5 and 15 Amps socket outlet on independent board but below the switch board of light points in the same vertical plane complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 2.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.)
S & F modular switch, 1 way, 6 A, 1 module 240 Volt complete all as specified and as directed.
S & F modular switch, 1 way, 16 A, 1 module 240 Volt complete all as specified and as directed.
S & F (3 pin and 2 pin) combined modular socket outlets, 6A, 2 modules, 240 V, AC, 50 Hz with earthing contact, rewirable, pillar type terminal, normal protection, unenclosed, without Shutter, Flush type, Design B complete all as specified and as directed.
S & F (3 pin and 3 pin) with common earthing pins, combined modular socket outlets, 6A & 16A, 2 modules, 240 V, AC, 50 Hz with earthing contact, rewirable, pillar type terminal, normal protection, unenclosed, without Shutter, Flush type, Design B complete all as specified and as directed.
S & F modular bell push, 6A, 1 module, single pole, one way, 240 V, AC, 50 Hz, ordinary (IPXO), normal gap construction, unenclosed, flush type, screw type terminals, pattern no. 1, rocker type, design A complete all as specified and as directed.
S & F Modular fan regulator, 120 W, 2 modules complete all as specified and as directed.
S & F buzzer, din dong, suitable for single phase, AC, 240 volts complete all as specified and as directed.
Supply and fix metal flush box 12 module complete all as specified and as directed.
Supply and fix metal flush box 8 module complete all as specified and as directed.
Supply and fix metal flush box 6 module complete all as specified and as directed.
Supply and fix metal flush box 4 module complete all as specified and as directed.
Supply and fix metal flush box 3 module complete all as specified and as directed.
Supply and fix metal flush box 1 or 2 module complete all as specified and as directed.
S & F modular white cover plate with frame, 12 modules complete all as specified and as directed.
S & F modular white cover plate with frame, 8 modules complete all as specified and as directed.
S & F modular white cover plate with frame, 6 modules complete all as specified and as directed.
S & F modular white cover plate with frame, 4 modules complete all as specified and as directed.
S & F modular white cover plate with frame, 3 modules complete all as specified and as directed.
S & F modular white cover plate with frame, 1 module complete all as specified and as directed.
S & F LED tube light fitting 2 feet 10 watts including tube with high power LEDs as light source and electronic driver complete all as specified and as directed.
S & F LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light, CRCA steel sheet housing, CRI greater than 80%, power factor of minimum 0.95, life span of minimum 50000 working hours complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
Supply and fixing of decorative wall mounting lamp, made up of high grade engineering plastic material, gold finish fixture with white glass diffuser with and including 9/10 watt LED lamp with B22/E27 base complete all as specified and directed.
M & L for bracket made out of GI pipe 40 mm dia medium grade, 1.2 metre long bent to shape with MS flat iron clamps made out of 40 mm X 6 mm thick mild steel nuts, bolts including taking down old unserviceable complete all as specified and as directed.
S & F double door MCB Distribution board of sheet metal enclosure, single pole and neutral, 12 way with 200 Amps rated bus bar, 240 volt, IP42 protection grade and fixed with PVC plug and screws and grouted in wall with M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
S & F double door MCB Distribution board of sheet metal enclosure, single pole and neutral, 4 way with 200 Amps rated bus bar, 240 volt, IP42 protection grade and fixed with PVC plug and screws and grouted in wall with M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed.
Supplying, installing, testing & commissioning, Storage Geyser, five star rated, 25 litres Capacity, steel body with stainless steel inner tank material, shock proof, auto cut, on-off indicator, thermoplastic body, corrosion free with safety valve, fusible plug, thermal cut out including fixing by grouting and fastener complete all as specified and as directed.
Supply and fix wall mounted fan of metal body with plastic blades, 400 mm sweep, 1350 rpm, 55 watts, 240 V, 50 Hz, air deliver 65 m³ per minute, three Nos of speed controlling complete all as specified and as directed.
S & F of electric chimney wall mounted with flow of 1200 cum/hr, filterless auto clean chimney, motion sensor with built in oil collector, powder coated, stainless steel, noise level 58dB, 220 volt, 50 Hz with all accessories required for fixing incl hose pipe and testing of approved make complete all as specified and directed.
Taking down ceiling fan 1200/1400 mm sweep / exhaust fans 300mm/ geyser of capacity upto 50 Ltr including disconnection of electric connection a complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning in renewal of cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 4 core, nominal cross sectional area of main conductor 16 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning in renewal of cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 2 core, nominal cross sectional area of main conductor 16 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning in renewal of cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 2 core, nominal cross sectional area of main conductor 10 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.
Ganesh Contruction (BID ID -3231316)
L P Singh and Co. (BID ID -3231026)
S AND A ENGINEERS CONSTRUCTION CO (BID ID -3231377)
TARKESHWAR DASS CONSTRUCTION COMPANY (BID ID -3230972)
Aditya Enterprises (BID ID -3231001)
M/s Prem Associates (BID ID -3231290)
K B Enterprises (BID ID -3230835)
B B BUILDERS (BID ID -3231024)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .