| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.0 CrAccepted-AOC | ₹3.0 Cr | L1 | Accepted-AOC L-1 |
| 2 | L2₹3.1 Cr+₹10.9 L (3.66%)Rejected-Finance | ₹3.1 Cr+₹10.9 L (3.66%) | L2 | Rejected-Finance L2 |
| 3 | L3₹3.3 Cr+₹31.6 L (10.6%)Rejected-Finance | ₹3.3 Cr+₹31.6 L (10.6%) | L3 | Rejected-Finance L3 |
| 4 | L4₹3.5 Cr+₹54.4 L (18.3%)Rejected-Finance 2403 SOUTH SAMAJ STREET NEAR SRI RAM APARTMENT THARPAKHNA RANCHI RANCHI JHARKHAND 834001 | RANCHI | JHARKHAND | 834001 | ₹3.5 Cr+₹54.4 L (18.3%) | L4 | Rejected-Finance L4 |
| 5 | L5₹3.5 Cr+₹54.7 L (18.4%)Rejected-Finance AMIKA MANSILLPARK SASCET DARDEADO JOINED COLLEGE DOORDA RANCHI HOB | ₹3.5 Cr+₹54.7 L (18.4%) | L5 | Rejected-Finance L5 |
| Sl No | Description | Qty | Unit | M/S AMAN ENTERPRISES L5 | RABBANI CONSTURCTION PRIVATE LIMITED L7 | M/s Dhananjay Yadav L2 | Raj Enetrprises L3 | UTSAV UDHYOG L6 | M/S AADYA HOMES L1 | SNG Buildtech Private Limited L4 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Earth work in excavation in foundation trenches in ordinary soil ( vide classification of soil item A) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing roots of trees, and shrubs all complete as per approved design, building specification and direction of E/I. | 925.74 | cum | 150.3 ₹1,39,138.12 | 151.82 ₹1,40,545.24 | 131.7 ₹1,21,919.43 | 139.85 ₹1,29,464.18 | 151.06 ₹1,39,841.68 | 130 ₹1,20,345.68 Lowest | 141.82 ₹1,31,287.88 |
| 2.00 | Extra for earth work in hard soil as per specification and direction of E/I. (vide classification of soil item - B). | 169.83 | cum | 15.35 ₹2,606.92 | 15.51 ₹2,634.09 | 13.45 ₹2,284.24 | 14.28 ₹2,425.2 | 15.43 ₹2,620.51 | 13 ₹2,207.82 Lowest | 15.51 ₹2,634.09 |
| 3.00 | Earth filling in foundation trenches and plinth in layers not exceding 150 mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation trenches within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I. (mode of measurement compacted volume) | 325.68 | cum | 54.73 ₹17,824.36 | 55.28 ₹18,003.48 | 47.96 ₹15,619.52 | 50.92 ₹16,583.52 | 55 ₹17,912.29 | 47 ₹15,306.87 Lowest | 55.28 ₹18,003.48 |
| 4.00 | Providing coarse clean sand in filling in in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume) | 87.95 | cum | 583.61 ₹51,330.25 | 589.51 ₹51,849.17 | 511.4 ₹44,979.16 | 543.04 ₹47,762 | 586.56 ₹51,589.71 | 500 ₹43,976.5 Lowest | 589.51 ₹51,849.17 |
| 5.00 | Clearing grass and removal of rubbish up to a distance of 50 meters outside the periphery of the area | 0.8 | HEC | 19,562.7 ₹15,650.16 | 19,760.3 ₹15,808.24 | 17,142.06 ₹13,713.65 Lowest | 18,202.5 ₹14,562 | 19,661.5 ₹15,729.2 | 19,700 ₹15,760 | 19,760.3 ₹15,808.24 |
| 6.00 | Providing P.C.C. M - 75 with nominal mix of (1:4:8) in foundation with approved quality of stone metal grade III (50 mm to 25 mm size) clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position, vibrating, striking, curing, taxes and royalty all complete as per building specification and direction of E/l. | 204.1 | cum | 3,714.12 ₹7,58,037.04 | 3,751.64 ₹7,65,694.72 | 3,254.55 ₹6,64,240.64 | 4,000 ₹8,16,384 | 3,532 ₹7,20,867.07 | 3,188 ₹6,50,658.05 Lowest | 3,701.64 ₹7,55,489.92 |
| 7.00 | Providing designation 75 B one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/l. | 316.38 | sqm | 327.04 ₹1,03,470.55 | 330.34 ₹1,04,514.62 | 286.57 ₹90,666.45 | 304.3 ₹96,275.96 | 328.69 ₹1,03,992.59 | 280 ₹88,587.8 Lowest | 330.34 ₹1,04,514.62 |
| 8.00 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 Cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 40 mm nominal size) | 1.91 | M3 | 4,458.4 ₹8,502.17 | 4,503.43 ₹8,588.04 | 3,906.73 ₹7,450.13 | 4,148.4 ₹7,911 | 4,480.91 ₹8,545.1 | 3,828 ₹7,300 | 335.28 ₹639.38 Lowest |
| 9.00 | Providing and fixing at or near ground level precast cement concrete in kerbs, edgings etc. as per approved pattern and setting In position with cement mortar 1:3 (1 Cement : 3 coarse sand), including the cost of required centering, shuttering complete. | 20.62 | CUM | 5,195.16 ₹1,07,150.18 | 6,000 ₹1,23,750 | 4,552.33 ₹93,891.81 | 4,833.94 ₹99,700.01 | 5,221.4 ₹1,07,691.38 | 4,460 ₹91,987.5 Lowest | 5,247.64 ₹1,08,232.58 |
| 10.00 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level, 1:1.5:3 (1 cement : 1.5 coarse sand {zone-lll}: 3 graded stone aggregate 20 mm nominal size) | 25.1 | cum | 5,165.82 ₹1,29,667.25 | 5,218 ₹1,30,977.02 | 4,526.62 ₹1,13,622.69 | 4,806.64 ₹1,20,651.47 | 5,191.91 ₹1,30,322.13 | 4,435 ₹1,11,322.94 Lowest | 5,218 ₹1,30,977.02 |
Tender Value
₹3.6 Cr
EMD Value
₹3.6 L
Closing Date
20 Aug 2025, 3:00 pmClosed
E.E., BCD, Building Division, Ramgarha
E.E., BCD, Building Division, Ramgarha
Construction of Environment Awareness Centre, Ramgarh
2025_BCD_103821_1
BCD/EE/RAMGARH/ 10 /2025-26
Open Tender
Civil Works - Buildings
Works
330 days
Ramgarh
Please refer Tender documents.
2 documents required · 2 mandatory
₹10,000
₹3.6 L
16 Oct 2025
8 Aug 2025
21 Aug 2025
8 Aug 2025
20 Aug 2025
8 Aug 2025
Amount
Earth work in excavation in foundation trenches in ordinary soil ( vide classification of soil item A) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing roots of trees, and shrubs all complete as per approved design, building specification and direction of E/I.
Extra for earth work in hard soil as per specification and direction of E/I. (vide classification of soil item - B).
Earth filling in foundation trenches and plinth in layers not exceding 150 mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation trenches within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I. (mode of measurement compacted volume)
Providing coarse clean sand in filling in in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume)
Clearing grass and removal of rubbish up to a distance of 50 meters outside the periphery of the area
Providing P.C.C. M - 75 with nominal mix of (1:4:8) in foundation with approved quality of stone metal grade III (50 mm to 25 mm size) clean coarse sand of F.M. 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position, vibrating, striking, curing, taxes and royalty all complete as per building specification and direction of E/l.
Providing designation 75 B one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/l.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 Cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 40 mm nominal size)
Providing and fixing at or near ground level precast cement concrete in kerbs, edgings etc. as per approved pattern and setting In position with cement mortar 1:3 (1 Cement : 3 coarse sand), including the cost of required centering, shuttering complete.
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level, 1:1.5:3 (1 cement : 1.5 coarse sand {zone-lll}: 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sandizone-Iil} : 3 graded stone aggregate 20 mm nominal size).All works above plinth level upto floor V level
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
Centering and shutteing including struting, propping etc and removal of form for
Foundations, footings, bases for columns, etc for mass concrete
Suspended floors, roof , landings , balconies and access platform
Lintels, beams, plinth beams, girders, bressumers and cantilevers
Columns, Pillars, Piers, abutments, Posts and struts
Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands,copings, bed plates, anchor blocks and the like
Edges of slabs and breaks in floors and walls.
Under 20 cm wide
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using fly ash and cement content as per approved design mix, including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering, shuttering, finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate / retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in - charge. NOTE- (1) Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately.All works upto plinth level
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using fly ash and cement content as per approved design mix, including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering, shuttering, finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate / retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in - charge. NOTE- (1) Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately.All works above plinth level upto floor V level
Add for using extra cement in the items of design mix over and above the specified cement content therein.
Providing Tor steel reinforcement of 8mm dia rods as per approved design and drawing exclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. TMT Fe 500 (only valid for SAIL & TATA STEEL)
Providing Tor steel reinforcement of 10mm,12mm,& 16mm. dia bars as per approved design and drawing exclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I.
Providing Tor steel,reinforcement of12mm,16mm, 20mm, 25mm, 32mm dia bars as per approved design and drawing -do- -do- 20125 mm dia TMT bar Fe 500 (Only valid for SAIL & TATA Steel) JSPL, and Vizag Steel) 30%
Providing designation 75Bwork in C.M. (1:6) in foundation and plinth with approved quality of clean coarse sand of F.m. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials ranking out joints to 15mm depth, curing taxes and royalty all complete as per building specification and direction of E/I.
Providing designation 75A brickwork in CM (1:3) in superstructure with approved quality of clean coarse sand of FM 2 to 2,5 including providing 10mm thick mortar joints , cost of screening, materials, scaffolding, raking out joints to 15mm depth curing, taxes and royalty all complete as building specification and direction of E/I
Providing designation 75 B brick work in C.M.(1 :6) in superstructure with approved quality of clean coarse sand of F.M. 2 to2.5 including providing 10 mm thick mortar joints cost of screening materials , scafolding , raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/l.
Providing designation 100 A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9"x4.5"x3") in C.M. (1:4) in foundation and plinth with approved uality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I.
Providing Designation 100A B/W with Fly Ash Lime Brick (FALB) conforming to IS 12894-1990 (9"x4.5"x3") in cement mortar (1:6) in Superstructure with clean coarse sand of F.M. 2 to 2.5 including 10mm thick mortar joints,cost of screening, raking out joints to 15 mm depth, curing, taxes and royalty all complete as per building specification and direction of E/l.
Providing designation 112mm thick reinforcement designtion 100 A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9"x4.5"x3") in C.M. (1:4) in supertructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including cost of screening materials scaffoliding raking out joints to 15mm depth curing taxesand royalty ( but excluding theb cost of reinforcement) all complete as per building specification and direction of E/I.
Providing average 150 mm thick dry rammed koha beaten to 112 mm. (Compacted with water ) made of well burnt or jhama bricks including ramming properly till compacted thickness is achieved, curing and carriage of water with all leads, making proper slope and blending the top with cement mortar (1:10) all complete as per building specification and direction of E/I.
Providing and laying Double charge virtified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622/ ISO 13006 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @3.3 kg/sqm including grounting the joints with white cement and matching pigments etc. complete Size of Tile 600x600mm
Providing and laying 15 mm - 23 mm thick kotah stone slab flooring of approved size, texture and colour over 19mm thick base of lime morter (1:1:1) (lime putty : surkhi: coarse sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing to granolithic finish with approved quality of carborandum stone including cost of curing, taxes and royalty all complete as per building specification and direction of E/I.(iv) 600 x 600 mm size
Providing and laying 15 mm - 23 mm thick kotah stone tiles in risers of steps, skirting and pillars of approved size, texture and colour laid over 12mm thick cement mortar (1:3) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing to granolithic finish with approved quality of carborandum stone including cost of curing, taxes and royalty all complete as per building specification and direction of E/I.
Supplying, fitting and fixing good quality, well dressed and well seasoned sal wood work in charkha in doors, windows skylights, fanlights and C/W celetial windows openings, including wedge over all clamps complete including application of two coats of wood preservative of approved quality on the surface butting walls and lintels all complete as per building specification and direction of E/I.
Supplying, fitting and fixing 30mm thick solid core type decorative single leaf flush door shutter with both sides decorative veneered with black board core bended with high quality phenol formal dehydes synthetic resin of standard make with Aluminium fittings such as hinges, tower bolts, handle, cleats and sand blocks and taxes all complete as per building specification and direction of E/l.
Water proofrng for Old and New Roof Slab :- Providing and laying water prooflng treatment on roof slab by applying two Component, factory a designed ready to use, acrylic modified flexible material applied with brush, roller or spray waterproofi ng coating as per manufacturer specification-With following steps :-
(a)surface preparation :-Provrding and cleaning of concrete surface to remove dust, oil, grease including removal of existing loose paint / coating, and cement laitance by cleaning with compressed air & water jet including all materials, labour, tools complete. Ponding test to be done after plugging all outlets and to be checked from soffit to identify seepage, leakage. On identification of seepage, cement grouting to be done with non shrink expanding admixture of Sika lndia Pvt.Ltd.
/ MYK Schomberg / Dr Fixit/Fosroc or equrivallent. Providing and reparing of all corners and joints such as those between the parapet wall and the roof slab etc shall be chamfered with '150mm X '150 mm fillet of mortar (Cement: sand - 1:4) admixed with acrylic polymer of Sika/ Fosroc/MYK Schomberg/Dr Fixit or equivalent Before chamfering a prime coat shall be given with the slurry of acrylic polymer Repairing surface irregularities, damaged concretein base slab, dead cracks if any, with an acrylic polymer modified repair mortar including a coat of bonding agent of the same with cement slurry including all material, labour, tools complete.
(b)1st Coat :- Apply 1st coat of two component acrylic modified, ready to use, flexible cementitious material on surface saturated dry roof and inside wall of Parapet wall upto 600 mm by brush or roller. After 1st coat of application ,45 gsm oI Fibre glass cloth to lay when the first layer is still green. 1st coat should be applied @1.50 kg/SQM/coat For the purpose of measurernent tte entire treated surface will be measured."
(c) :2nd Coat:- To apply the 2nd coat of two component acrylic modified,ready to-use, flexible cementitious material right angle to the '1st coat over the glass fibre laid surface. 2nd coat should be applied @0.7 kg/ SQM/coat. For the purpose of measurement the entire treated surface will be measured." Alter three days of drying the 2nd coal , the rain water outles to be plugged and ponding test to be done for 48 hours to identify seepage, leakage from soffit and if found necessary rectification lo be done as per satisfation of E/c.
The Watqrproofing Brand:*Sil<a Topseal 109hi / Fosroc Brushbond RFX/ Dr Fixit Pidiffin 2Kl MYK Aqraiin TG Product Performance - Chemical Base Part A.Acrylic copol;,mer, Part 13 Specially graded cementitious powder -Density 1.6 kg/l (mixed density) at +270C Tensile Strength -2 N/mm2 after 28 Days (with Fibre cloth) (According to ASTM D 2370)Pullout Bond Strenth-2 n/mm2 (concrete failure) (According to ISO.
4624) Slant-Shear Bond Strength -4 N/mm2 (According to FIP 5.15) Elongation at Break -35% without Fibre Cloth and 20% wilh Fibre Cloth (According to ASTM D 2370)
D Protection of treated with pcc :- The treated surface shourd be covered with 25mm/50mm PCC of M-20 grade(1:1.5:3) with proper slope ( 1:120) towards the rain outlets in alternatepanels of 2 mtx2mt keeping 6 mm gap between the panel joint. integral water proofing admixture conforming to lS 2645 @ of 100 ml perbag of of cement to be added in the screed concrete (paid separately for thts ltems
all corners shall be charfered with 150mm X 150 mm fillet. The rain water outlets shall be just leveled with the screed concrete to ensure smooth discharge of water - the peripheral gaps between pvc pipe outlet and concrete surface should be packed properly with rich concrete and the peripheral mouth to be sealed with moisture insensitive epoxy putty of Sika lndia Pvt.Ltd / IVIYK Schomberg / Dr FixiUFosroc .For the purpose of measurement the entire treated surface will be measured."
(e)Groove of PCC surface should be filled with Polysulphide Sealant (Paid Separately) Brand - Sika lndia Pvt Ltd / MYK Schomberg / Dr Fixit/Fosroc
Covering of treated surface wrth PCC :- Providing 50 mm thick Cement Concrete M20 (1:1.5:3) raintaining slope in alternate 2 mIx 2 mt panels with aaproved quality of stone chips of 20 mm to 6 mm size graded and clcaned sand of F M 2 5 io 3 including screening,shuttering,and mixing cerite nt c0ncrete in mixer with admixture of integral water proofing and placing rn position,strikirrg cLrring,t-a]glgnd royality all complete as per buildirrg specifictionJand direction of E/l.Panels that has been left should be casteci nextday.-lhere should be 6 mm gap between Panels.Brand- Sika *Plastocrate plus,MYK proof WP10, Fosroc- Conplast X421ic , Dr Frx,t Prdiproof LWr
Providing and mixing Liquid lntergral water proofing compound in Conctrete or plaster as per rnanufacturer specificatioqand as per cjirection of Eng - in Charge Brand- Sika Plastocrate plus, MYK proof WP 1 0, Fosroc-Cc.rnplast X4211 C, Dr fixit Pidiproof LW+ or Equivalent
Provrding and filling of Groove between 50 mm PCC Panels with Polyshlphide Sealant (Poring Grade)as per drawings and technical specifications and dii-ection of E in Charge (with 1B% GST).Brand:-Sika- Polysulphide, Fosroc-l-hioflex 600 Dr. Fixit Pidiseal PS(42P),MYK Seal PS or Euivallent
Supplying, fitting and fixing M.S. grill gate with M.S. grills made of 20x6mm M.S. flats or 16mm square bars fitted on 25x25x6mm M.S Angle frame including cost of fabrication , providing necessary locking arrangement with haskal and domny duly fixed in P.C.C. (1:2:4) blocks of required size, applying a priming red lead paint over steel work, taxes all complete as per drawing specification and direction of E/l.
Providing 12mm cement plaster (1:3) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per specification and direction of E/I.
Providing 12mm thick cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per specification and direction of E/I.
Providing 6mm cement plaster (1:4) in celling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
Providing 1.5mm cement punning including curing, carriage of water with all leads and lifts as per building specification and direction of E/I.
Providing 12mm thick water proof cement plaster (1:3) with clean coarse sand of FM 1.5 with 5% cico or any other approved water proofing compound including screening, curing, with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I
Providing 19 mm thick water proof cement plaster (1:3) with clean coarse sand of F.M. 1.5 with 5% cico or any other approved water proofing compound including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/l.
Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by rubbing smooth with pumice stone or fine sand paper, applying putty wherever required, scaffolding, washing of floors and taxes all complete as per building specification and direction of E/l.
Providing primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing dust, dirt, scales smokes and grease and cleaning the surface horoughly including cost of scaffolding and taxes all complete as per bullding specification and direction of E/l.
Providing two coats of synthetic enamel paint of approved shade and make over steel surface -do?
CARRAIGE OF MATERIALS
SAND (UPTO 16KM LEAD)
CHIPS (UPTO 22KM LEAD)
BRICKS (UPTO 8KM LEAD)
LOCAL SAND (UPTO 3 KM LEAD)
Providing and fixing brass/C.I. stop cock of approved quality all complete as per specification and direction of E/I.
15 mm dia
Providing and fixing G.M. non return valve Horizontal/Vertical type of approved quality as per specification and direction of E/I.
25 mm dia
32 mm dia
Making holes in walls for laying G.I. pipe and restoring the same after pipe laying as per specification and direction of E/I.
115 mm thick wall
250 mm thick wall
Supplying, fitting and fixing the following items complete with all materials as per specification and direction of E/I.
Mirror (300 x 450mm)
C.P. brass tower rail
C.P. brass soap container medium quality with screw and hinges etc.
Supplying, fitting and fixing viterious white glazed earthen ware I.W.C. of parry Hindustan or any other I.S.S. approved make with 100mm H.C.I. 'p' trap 15 litres C.I. pull and let go flushing cistern of names or other I.S.S. equivalent make, complete with all fittings C.I. or C.C. brackets 32mm alkathene/P.V.C. telescopic flush, pipe about 2M long with one brass coupling and clamps G.I. chain and pull including supplying and fixing a pair or viterous white glazed earthenware footrest to be fixed in floor 15mm C.I. body brass spindle stope cock of weight not less than exposed pipe and cistern with two coats of approved paint over a coat of red oxide primer etc. all complete as per specification and direction of E/I. 580mm long - With 12.5 lit. low level PVC cistern
Supplying, fitting and fixing 40mm highb viterous white glazed earthen E.W.C. with 'P' trap of parry hindustan or any other approved I.S.S. make including supplying and fixing 15 litres C.I. mosquito proof low down flushing cistern of approved make with complete fitting with C.I. handle and R.S. or bracket with telescopic flush pipe with brass coupling and plumbers joints spindle stope cock of approved quality weight not less than 450 grams 15mm PVC alkathene pipe 45cm. long with brass coupling at both ends and white/black plastic soild state seal and lead of commander/cuckoo or other I.S.S. make with hinges or screws etc. painting pipe and cistern etc. with 2 coats of approved paint over a coat of red oxide priming all complete as per specification and direction of E/I. With 'P' trap - 12.5 lit low level PVC Cistern
Supplying, fitting and fixing flat back or angular, lipped front viterous white glazed earthen ware urinal of 'Hindustan "Parry" or any other approved I.S.S. make with 5 liters capacity C.I. automatic flushing cistern of reliance for any other I.S.S. approved make with all fittings with C.I. or R.S., brackets, standard size G.I. flush pipe with fitting clamps, 15mm, C.I. body brass spindle stop cock of approved quality weight not less than 400 grams, 15mm P.V.C./Alkthene pipe 450mm long with brass coupling at both ends and doing plumber joints including painting coat of red oxide cutting wall and floor making good the same etc. all complete as per specification and direction of E/I.(a)Flat back or Standing Cornar
Supplying, fitting and fixing viterous white glazed earthen ware wash hand basin of parry or Hindustan or any other I.S.S. approved make supported on pointed C.I. or R.S. brackets 32m C.I. brass waste 15mm dia C.I. body brass spindle stop cock of approved quality of weight not less than 350grms. 32mm P.V.C. waste pipe 750mm long with brass coupling at one end and making plumber joints etc. all complete as per specification and direction of E/I.
Supplying materials and labours for constructing inspection chamber of designation class 75B bricks size 750mm deep, 600 x 450mm internal dimension having 250mm wall thickness in cement mortar (1:6) including 12mm cement plaster (1:4) with punning on inside and cement plaster (1:6) with 600 x 475mm G.I. Cover with frame (weight not leaa than 36 kg) alongwith earth work in exacavation and 80mm thick P.C.C. (1:3:6) in foundation and refilling all complete as per specification and direction of E/I.
Approved basic rates construction materials for preparation of schedule of rates only, (Material should conform to relevent B.I.S. specification). The rates are inclusive of all taxes, royalty, cess and carraige but exclusive of contractor's profit and overhead charges - Special type of C.P. Bath room fitting for V.I.P. buildings (JAL, Jaguar, Marc or equivalent mark)
Pillar cock
Angular Stopcock /2 way bib cock
Providing and placing on terrace (at all floor levels) polyethylene waterstorage tank, ISI : 12701 marked, with cover and suitable lockingarrangement and making necessary holes for inlet, outlet and overflowpipes but without fittings and the base support for tank.
Wiring for Light point / Fan point / Exhaust Fan point / Call Bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit , with modular switch ,modular plate ,suitable GI box as required a) Group - C
Wiring for twin controlled light point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit , with 2 way modular switch ,modular plate ,suitable GI box etc as required.
Wiring with 2 x 2.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit alongwith 1 No. 2.5 sq.mm FR PVC insulated copper conductor single core cable for loop earthing as required.( For primary 5A Socket , Primary MCB Point and Circuit Wiring)
Wiring with 2 x 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit alongwith 1 No. 1.5 sq.mm FR PVC insulated copper conductor single core cable for loop earthing as required.( For Secondary MCB Points and 5A Secondary Points)
Wiring for light / power plug point with 2 x 4 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC Medium Class conduit alongwith 1 No. 4 sq.mm FR PVC insulated copper conductor single core cable for loop earthing as required.( For 16A Socket)
Wiring for light / power plug point with 2 x 6 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit alongwith 1 No. 6sq.mm FR PVC insulated copper conductor single core cable for loop earthing as required.( For A/C Sockets)
Wiring for DB submain with 4 x 16 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit alongwith 2 No. 16sq.mm FR PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for DB submain with 4 x 10 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit alongwith 2 No. 10sq.mm FR PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for DB submain with 2 x 10 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit alongwith 1 No. 10 sq.mm FR PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for DB submain with 2 x 6 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit alongwith 1 No. 6 sq.mm FR PVC insulated copper conductor single core cable for loop earthing as required.
Supplying and fixing suitable size GI box with modular plate and cover in Front on surface or in recess ,including providing and fixing 3 pin 5 / 6 amps modular socket outlet and 5 / 6 amps modular switch,connection,painting etc.as required.
Supplying and fixing suitable size GI box with modular plate and cover in Front on surface or in recess ,including providing and fixing 6 pin 15 / 16 modular socket outlet and 15 / 16 amps modular switch,connection,painting etc.as required.
Supplying and fixing 20 Amps ,240 Volts , SPN industrial type , Socket outlet, with 2 pole and earth, metal enclosed plug top along with 20 amps , 2Pole, RCCB in sheet steel enclosure , on surface or in recess with chained metalcover for the socket out let and complete with connections, testing and commissioning etc. as required. 20A, 3 pin socket outlet controlled by 20A 2P RCCB
Supplying of following 1100 volt grade XLPE insulated PVC sheathed aluminium / Copper conductor armoured cables as per specification as required.
3.5 core 25sq. mm.
4 core 16sq. mm.
4 core 10 sq. mm.
MV cable laying upto 25 sq.mm. in same trench - Laying of one number additional PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 35 sq.mm. direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc. as require.
MV cable laying upto 35 sq.mm. in pipe - Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 35 sq.mm. in the existing RCC/HUME/STONEWARE/METAL pipe as required.
Earthing with copper . Earth plate 600 mm x 600 mm x 3 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc.( with charcoal or coke and salt).
Supply and laying 25mmX5 MM GI strip at 0.50 meter below ground as strip earth electride including soldering etc as required
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
S.I.T.C of following rating Led flood light
50/60 WATT FLOOD LIGHT
S.I.T.C of following rating reccess/surface mounted LED round/square shape down light luminarie with pressure die cast housing for single phase supply voltage. Luminarie shall be confirmed to IS: 10322 part-5/section-2 or IEC-62722 with all necessary accessories as required.
18/20 W LED light
10W LED Bulkhead fixture
Supply and fixing of step type electronic fan regulator on existing modular plate switch box including connection but excluding modular plate etc as required.
Supply, Installation, Testing and Commissioning of following size fan 3 Blades confirming to IS:374:2019 including wiring the down rods of stranded for 230 V 50 Hz, single phase supply etc. complete as required.1200mm (48") Ceiling Fan
Supply of heavy duty type exhaust fans of following size sweep with gravity louvers shutters including all accessories/installation materials required make HAVELS/USHA.
Installation of exhaust up to 450mm sweep in the existing opening, including making the hole to suit the size of the above fan, making good the damage, connection, testing, commissioning etc. as required
Supplying and fixing of following size PVC conduit alongwith the accessories in surface / recess including painting in case of surface conduit or cutting and making good the same in case of recessed conduit as required as per specification.
20mm dia
25mm dia
32mm dia
Supplying installation, testing and commissioning of surface-recess mounting type three pole and neutral,prewired, sheet steel, MCB distribution board 415 volt, tinned copper busbar, common netrul link, earth bar, din bar for mounting MCB detachable gland /knock out plate,, phosphatized and powder coated and complete with MCBs . RCCBs , Isolator etc as required
TPN DB( Double door)
A. TP&N D.B (Vertical TYPE)
i) 1 No. 63 Amps 4P MCB Isolator + RCCB
iv) 24 Nos. 6-32 Amps SP MCBs as outgoing
A. TP&N D.B (HORIZONTAL TYPE)
i) 1 No. 40 Amps 4P MCB Isolator
ii) 1 No. 40 Amps 2P RCCB -3Nos
iii) 18 Nos. 6-32 Amps SP MCBs as outgoing
Supplying installation, testing and commissioning of surface-recess mounting type Siingle pole and neutral,prewired, sheet steel, MCB distribution board 240 volt, tinned copper busbar, common netrul link, earth bar, din bar for mounting MCB detachable gland /knock out plate,, phosphatized and powder coated and complete with MCBs . RCCBs , Isolator etc as required
SPN DB
SP&N D.B (HORIZONTAL TYPE)
i) 1 No. 40 Amps 2P RCCB -1Nos
ii) 10 Nos. 6-32 Amps SP MCBs as outgoing
SP&N D.B (HORIZONTAL TYPE)
i) 1 No. 25 Amps 2P RCCB -1Nos
ii) 6 Nos. 6-32 Amps SP MCBs as outgoing
Wiring for light point/ fan point / exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit, with modular switch, modular plate, suitable GI box etc as required.
Group C
Wiring for light/ power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit alongwith 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for light/ power plug with 4X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit alongwith 2 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required
2x1.5 sq mm + 1x1.5 sq mm earth wire
2x2.5 sq mm + 1x2.5 sq mm earth wire
2x6 sq mm + 1x6 sq mm earth wire.
Supplying and fixing of following sizes of PVC conduit along with the accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
20mm dia
25mm dia
32mm dia
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 amps one way switch
15/16 amp one way switch
5/6 amp 3 pin socket outlet
5/16 amp 6 pin socket outlet
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.
4/5 Module (78mm x140mm x 50mm)
6 Module (78mmX205mmx50mm)
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
12 Way Double Door
Supplying and fixing 6 Amp to 32 Amp rating 240 volts, 10 KA "C" Curve Miniature Circuit Breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc.,as required.
6 / 32 Amp Single Pole
50/63 Amp DP
Supplying and fixing of following rating double pole ( Single pole & neutral), 240 volts, resudual current circuit breaker (RCCB), having a sensivity current 30 miliampere in the existing MCB DB complete with connections, testing & commissioning etc as required.
Providing and fixing M.V. danger Notice plate of 200mm x 150 mm of made of mild steel, at least 2 mm thick and vitreous enamelded white on both side and with inscription in single red colour in front side as requird
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (with charcoal or coke and salt) as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Supply of XLPE insulated PVC sheathed, heavy duty, armoured electrical cable with aluminium conductor for working voltage upto and including 1100 volts. (conforming to IS-7098. (Part-I).
3.5 core, 35 sq.mm.
2 core, 10 sq.mm.
2 core, 6 sq.mm.
SITC of following rating recess / surface mounted LED round / square shape down light luminarie with pressure die cast housing for single phase supply voltage Luminarie shall be confirm to IS: 10322 part -5 / section -2 or IEC :62722 withh all neccesary accessories as required. Make:- Havells/Philips/Crompton/Wipro / India Bulls.
12W LED Round Down Light (Surface )
18 /20 W LED Round Down Light (Surface)
Bulk Head fitting with 9/10Watt LED.
S.I.T.C of following rating surface mounted LED Tube Lighting Fitting Suitable for 230V 50 Hz, Single Phase Supply etc. complete as required.
10/12 W LED Tube Light
20/22 W LED Tube Light
SITC of 300 mm (12") Exhaust fan (Metal body) suitable for single phase 230 volts, 50 Hz., AC supply complete with motor, louvers/shutters etc. complete as required. Make :- Usha/Crompton / Havells .
Supply of 20mtr. High mast in two section Construction 5355 grade as per BIEN 10 025 Top Dia 150mm, bottom dia 410mm, plate thickness 3mm,2Oside polygon, galvanisation as per BS EN ISO 146L, base plate dia 570mm, base plate thickness 25mm, GI single spike lighting protection, maximum wind speed 47 m/swith 8 nos foundation bolts of PCD 490mm TS 600/ 30mm dia/850 mm long. Luminaries carriage : Material for 50 NB ERW Class B - M.S. Pipe, dia of carriage ring 535mm (ID) with 6 arm, welded,2 sections having carrying capacity upto 12 luminaries. Trailing Cable : 5 core 4sq.mm. PVC flexible copPer conductor Winch/Power Tool : Double drum, SWL 750 kg with 1HP 6 pole single speed integral motor Rope : Grade A13131'6,7 /19 construction, dia 6mm, BLC 2350 x 2 having 2 nos of continues roPe. Aviation obstmction light: twin dome aviation obstruction lights LED type as required. (But excluding Feeder Pillar)
For 20 mtr. High mast: ITC of the high mast and light fixture with the help of suitable tools and plans, wiring of luminaries with all Wiring material like PVC insulate[Pvc sheathed flexible cable of suitlblb copper conductor lugs, MCB and all labour & construction of shallow foundation with M25 grade concrete for the high mast considering safe soil bearing capacity of 10T / mhs sq. for 20 M High mast.
S.I.T.C of floowing rating LED Street lighting luminarie with pressure die cast housing and toughened glass cover (IP 66 protecdon) ln odsttng pole/pipe for supply voltage \WTIY AC, 50H2. Luminarie shall be confirm to IS: 1(E22 part-5/secdon-3 and shall be complete with all neccssary accessories as required.
( LED FLOOD Light 240W)
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources)
Making Plinth protection 50mm thick of cement concrete 1;3;6(1 cement 3 coarse sand 6; graded stone aggregate 20mm nominal size ) over 75mm bad by dry brick ballast 40mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth.
Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern.
Extra for providing & placing in position 2 no 6mm dia ms bar every 3rd corse of half brick masonry
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite of any colour and shade,Area of slab over 0.50 sqm.
Stone tile (polished) work for wall lining over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and cement slurry @ 3.3 kg/sqm including pointing in white cement complete. Granite of any colour and shade
Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth.Granite Stone of approved shade
Providing and laying 1st quality Ceramic glazed wall tiles thickness to be specified by the manufacturer) in walls over 12mm cement mortar (1:3) and jointed with grey cement slurry flush pointed with white cement including rubbing polishing and cost of curing, taxes and royalty all complete as per building specification and direction of E/I.
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigment etc., complete.
Providing and laying 500x500x40 mm thick Turf paver (Turfpave XD) on 150 mm thick sub grade of compacted bed of 20 mm thick nominal size stone aggregate and base course and filling with 150 mm thick jamuna sand, including spreading, well ramming, consolidating and finishing smooth etc. all complete as per direction of Engineer-in-charge
Providing and fixing Glass mossaic tiles on finished plain wall surface of size 20 mm x 20 mm x 4 mm in all colour, design , fixing in customize design as per direction of Engineer-in- Charge. The glass mosaic tiles to be fixed on the wall surface with the help of approved adhesive applied at the rate of 2.5 kg per sqm and grouting of the same. The rate is inclusive of all operation, material and required pattern approved by Engineer-in-Charge:
Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : 11.55.1 Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size).
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design :In 75x75 mm deep chase
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement laster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
Providing & fixing on roof pressed clay tile (Mangalore tile) of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately).
Providing & fixing at all heights, levels and ocations Mill finish Aluminium alloy roofing sheets of alloy IS designation 31500, temper Hx8 conforming to IS 737 and dimensions as per IS code 2676 with characteristics of good formability and corrosion resistance. The profile sheets shall be fixed to truss members in slope or required pitch or curvature with Hex cap headed self drilling/tapping Stainless steel screws M6, 50 mm long with 3 mm EPDM seal washer etc. all inclusive of labour, scaffolding, T&P and sundries etc. complete as per directions of the Engineer-In-Charge. (Cost of truss/frame work shall be paid separately). 0.71 mm, troughed profile with center to center pitch of 200 mm, depth of 32 mm, overall profile width1092 mm, cover width 1000mm.
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Repairs to plaster of thickness 12 mm to 20 mm in patches of area2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge.14.1.2 With cement mortar 1:4 (1cement: 4 coarse sand)
Fixing chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts, embedding hold fasts in cement concrete blocks of size 15 x 10 x 10 cm with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size), painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge.
Door chowkhats
Window chowkhats
Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm.
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)
Providing and fixing glazing in door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5.50 mm thickness
Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. (Only weight of grill to be measured for payment).
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable materialwithin 50 metres lead as per direction of Engineer-in-charge.
Supplying NP2 R.C.C. hume pipe with colour as work site as per direction of E/I. 150mm dia
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
75 mm diameter
110 mm diameter
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
Single tee without door - 75x75x75 mm
Single tee without door - 110x110x110 mm
75 mm bend
110 mm bend
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall
25 mm nominal outer dia Pipes
32 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.
15 mm nominal outer dia Pipes
20 mm nominal outer dia Pipes
Supplying and stacking of good earth at site including royalty and carriage up to 1 km (earth measured in stacks will be reduced by 20% for payment).
Supplying and stacking at site dump manure from approved source, including carriage up to 1.0 km (manure measured in stacks will be reduced by 8% for payment)
Screened through sieve of IS designation 20 mm
Screened through sieve of IS designation 16 mm
Screened through sieve of IS designation 4.75 mm
Supplying and stacking of well decayed cow dung manure at site including royalty and carriage up to 1.0 km (cow dung manure measured in stacks will reduced by 8% for Payment)
Fine dressing of the ground
Mixing earth and sludge or manure in the required proportion specified or directed by the Engineer-in-charge
Spreading of sludge, dump manure and / or good earth in required thickness as per direction of Engineer-in-charge (cost of sludge, dump manure and / or good earth to be paid separately).
Uprooting rank vegetation and weeds by digging the area to a depth of 60 cm, removing all weeds and other growth with roots by forking repeatedly, breaking clods, rough dressing, flooding with water, uprooting fresh growths after 10 to 15 days and then fine dressing for planting new grass, including disposal of all rubbish with all leads and lifts
Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately)
Holes 1.2 m diameter and 1.2 m deep
Holes 90 cm diameter and 90 cm deep
Holes 60 cm diameter and 60 cm deep
Holes 45 cm diameter and 45 cm deep
Complete maintenance of the entire garden features having as per yard stick in the garden area i.e. lawn trees, shrubs, herbs, edge, flower beds, foliages, creepers etc. including hoeing, weeding, pruning, replacement of plants, gap filling, watering, mowing of lawn, grass cutting by lawn mover and brush cutter, removal of garden waste, applying insecticide, pesticide & fertilizers (whenever required) top dressing of lawn with good earth and manure and maintenance of other garden related works as directed by office-in-charge (Cost of Good Earth, Manure, Fertilizer, Insecticide, Pesticide will be provided by the Department & lawn mover and brush cutter with fuel and other T & P material/articles shall be provided by the contractor.) and as per direction of officer in charge.
Plumeria alba
Phoenix palm
Buddha belly bamboo
Hibiscus rosa-sinensis
Raphis excelsa
Tecoma gaudichaudi
TMC dwarf
Alternanthera red
Chlorophytum comosum
Jatropha
Sprenger's asparagus
Syngonium podophyllum
Tradescantia pallida
Cynodon dactylon
Wiring for group controlled ( Looped ) light/ceiling fan/exhaust fan/call bell point ( With out independent switch etc.) with 2x1.5 sq.mm PVC insulated stranded copper conductor cable alongwith 1 No. 1.5 sq.mm PVC insulated copper conductor cable for earthing in surface/recessed steel conduit as required. (Point shall be controlled / looped From existing point).a) Group - C
Supplying and making end termination of following sizes with brass compression gland including providing and crimping solderless plugs/ferrules of sizes PVC insulated PVC sheathed aluminum conductor armoured cable 1.1 KV grade.
3.1/2 core 25sq. mm.
4core 16sq. mm.
4 core 10sq. mm.
Cable Trays
Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required.( Powder coated shall be of Siemens Grey Colour- RAL 7032)
100mm width X 50mm depth X 1.6 mm thickness
Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17 .5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required.
100mm width X 50mm depth X 1.6 mm thickness
Constructing masonry Chamber 60x45x50 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for water meter complete with C.I. double flap surface box 400x200x200 mm (inside) with locking arrangement and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) , i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand:10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :With common burnt clay F.P.S.(non modular) bricks of class designation 7.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
Upto 35 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.
Upto 35 sq. mm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
2 x 6 sq. mm (19mm)
2 X 10 sq. mm (22mm)
3½ X 35 sq. mm (32mm)
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
120 mm dia (OD-120 mm & ID-103 mm nominal)
NON-SCHEDULE ITEMS Supply and Installation of Precast Concrete Reinforced Square Cement Flower Pots Material - Cement Shape (When viewed from Top) Square Artistic /Decorative work on Pots Yes Pot Length (mm) 18 inch Pot Width (mm) 18 inch Pot Height (mm) 18.5 inch
Supply and Installation of Precast Concrete Reinforced Bench M-30 Grade concrete mix in accordance with IS : 10269/Latest in gray cement by using vibro - compaction technique and with reinforcement as detailed in Govng. specn. ach seating plank ( bottom ) of bench bolted with leg by help of 12 mm dia. X 65 mm length galvanized steel countersunk bolts with EVA washer – Backrest planks fitted with half threaded carriage bolts and nuts of size 165 mm X 8 mm dia with EVA & steel washer Seat / plank length ± 3 mm = 1500MM Seat height ± 3 mm = 450 MM Seat width ± 3 mm = 440 MM
Providing Design, Detailed Engineering, Supply, Fabrication, Erection, Installation and placing in position of Architectural Membrane Primary MS Steel Structure Work. Using Min 210 MPa Yield Strength Mild Steel built up tubular trusses (Plates, CHS/ RHS/ SHS ERW M.S. tube as per Indian Standards and as per approved specifications Make ISI Marked with MTC Certificate.) including cutting, hoisting fixing in position. Such as Structure are welded and bolted including special shaped washers etc. complete. Hot Finished welded type tubes in Complete and direction of Engineer-In-Charge. MS ERW CHS Pipes as per specification under "IS 1239 (Part-1, 2004), YST 210"; SHS/RHS Pipes as per specification under "IS 4923 (2009), YST 210 MPa" and MS Plate as per specification under "IS 2062, YST 210 MPa". Steel Qty. as per Final Design & Drawing Approve. Note : - Approximate Steel Consumption 3kg/ sqft. Make APOLLO/JINDAL/BHUSHAN/TATA/SAIL/ISI Mark & Equivalent Providing and Applying the complete structure to be Two Coat of Enamel Paint over one coat of Red Oxide primer in required DFT of (dense film thickness) for each coat in total DFT of 60 microns. The work is to be executed as per technical specification and direction of Engineer-In-Charge.(Make: - ASIAN/ MRF/ BERGER/ NEROLAC/ JOTUN & Equivalent) Providing, fabricating, assembling and erection of TENSILE Membrane Fabric structure with TENSILE fabric having a minimum weight of 900g/sqm ,Tensile strength 4300/4200N/5cm ,tear strength 500/500N as per particular specification with a 10 years warranty etc. over steel frames with all fittings and fixtures such as Galvanized MS Membrane /End Plate, Shackles, Rigging Screws, Turnbuckles, swedge, fork, kedar rods & galvanized MS strands/cables with stainless steel end terminals complete by a specialized sub-contractor. Rate includes cost of fabric , shop drawings, patterning, forming, cutting, fabrication, hot weld stitch of fabric, , assembling and installation with GI cables, hardware ,Aluminum flat, EPDM gasket and required accessories wherever required complete including, tools and plants, etc. Required for all operations in all respect complete as per drawing, design, specifications and as directed by Engineer-in-charge. NOTE: fabric area to be measured. WARRANTY ON FABRIC 10 YEARS ON PRO-RATA BASIS AS REQUIRED Providing & Supplying of GI Cable with MS End Terminals & MS Nut & washer, Diameter as per Design, Type of cable is 6x19 strands of required length of Grade1570 steel core as per specification under "IS 2266 (2002), with MS end terminals at both ends of required length as per approved drawings as Under Membrane Cables complete in all respect as per direction Of Engineer-In-Charge.
Supply and Installation of Metal External Branding Signage Boards, Size 2.5 x 4 feet
Specifications Neck and Throat Diameter 600 millimeter Construction of Material Steel Vanes (Blades) 38 vanes,SS 0.7mm thick Technical Parameter Rivets Pop Rivets Bottom Ring Diameter 620mm, + 5 mm tolerance Rotation Twin seales intergrated bearing housing consisting of 2 nos Deep grooved ball bearings 6002-2Z permanently lubricated and sealed FRP base plate 1.5 -2mm thick 1 meter wide(approx) and 1.0 mtr long matching roof sheet profile Inner Arms and Rotating Ring Supports Aluminium Extrusion - 12mm x 3mm thick Outer Arms and Throat Brackets Aluminium strip - 4mm thick Height 389 millimeter Installation hardwares Zinc plated Mild steel Nut and Bolts Turbine Diameter and Centre Width (+/- 5mm) 680 millimeter Neck and Throat Diameter 600 millimeter Additional Bearing Protection Five Level Shield Against Dust and Fumes Center Shaft Stainless Steel Construction of Material Steel Top Plate MOC Aluminium, 1.2mm thick Base Ring MOC Aluminium, 1.2mm thick Variable Angle Elbow Aluminium elbow 0.71mm thick capable of countering roof slope upto 15 degrees Vanes (Blades) 38 vanes,SS 0.7mm thick Generic Additional Parameter Five level shield against dust and funes
Supply and Installation of LED SOLAR STREET LIGHT 75Watt Peak.Battery capacity-≥ 12.8 V (nominal), 30 Ah at STC (1 day autonomy).Type of LED (Light source)20 Watt White LED type.Ingress protection-IP65 or better.Nominal bore size of tube -40 mm / 3.2 mm.Height of pole (in m) - 6.Battery box-Outside the luminaire enclosure in a vented, acid proof and corrosion resistant, hot dip galvanized metallic box (IP65 or better) with anti-theft locking arrangement for outdoor use.Type of PV Module-Only indigenous modules of IEC Tested used. Crystalline high power/efficiency cells used in the solar photovoltaic module.Power output of PV Module-≥ 75 Wp at 16.4 ±0.2 Volt at STC.PV Module Efficiency-≥ 14%.The open circuit voltage of the PV modules under STC (in volts)- 21.Type of Battery-Lithium Ferro Phosphate battery (LiFePo4). Operating from dusk to dawn first four hour full brightness, rest of the time at lower level, with motion sensor.Battery capacity-≥ 12.8 V (nominal), 30 Ah at STC (1 day autonomy).Cycle/ Current-Battery cycle life 2000 cycle at 80 % discharge.Type of led-20 Watt White LED type .LED chip Efficacy (Lumen/watt)-≥135.Luminaire System Efficacy - Lumen output - (Lumen/watt)-≥120. The color temperature of white LEDs used in the system-5500 degree K – 6500 degree K.The temperature of heat sink-≤ 20 degree centigrade above ambient temperature during operation.CRI-> 70 %.Lighting quality-Free from glare, flickering and UV.Wattage-Power consumption of the LED Luminaire / Lighting unit ≤ 30W (including LED and Driver power loss)
.Ingress protection-IP65 or better.Provision of Fuses-Fuses provided to protect against short circuit conditions. Protection-Full protection against open circuit, accidental short circuit and for reverse polarity provided.The self consumption of the charge controller-≤ 20 mA at rated voltage and rated current.Total electronics efficiency-≥ 90 %.Provision on frame structure-Frame structure have provision that the module can be oriented at the suitable tilt angle.Conformity of the specification for Steel tube for street light pole-as per IS:1161:2014 latest.Hot dip galvanized condition the zinc coating on the tubes-as per IS:4736 latestNominal bore size of tube / Thickness of tube-40 mm / 3.2 mm.Battery box-Outside the luminaire enclosure in a vented, acid proof and corrosion resistant, hot dip galvanized metallic box (IP65 or better) with anti-theft locking arrangement for outdoor use. All Work as per E/I.
Supply and Installation of SEASAW Jungle Rumble Play Zone.Design slides, serpentine Slides and covered slides material-Premium quality FRP (fibre reinforce plastic).Roofs -Premium quality FRP (fibre reinforce plastic).Bridges floor-Premium quality FRP (fibre reinforce plastic).Thickness of slides-3 mm.Thickness of roof-3 mm.Thickness of bridge floor-3 mm.Material for stairs, bridge railing, slides supports-25 mm (B class conforming to IS 1239 latest) PU coated with the layer of thickness of 60 microns.Material for supporting stands-25 mm (B class conforming to IS 1239 latest) PU coated with the layer of thickness of 60 microns.Design-As per representative image - uploaded at QR/Spcn-Product Structure-G.I pipe Stairs – open and closed FRP slider – FRP bridges with pipe railing – huts type FRP roof supported by G.I pipes.Dimension ± 10 mm-Length - 13500 mm X Width - 6500 mm X Height - 3250 mm.FRP sheets finish -G.P resin of 3 mm to 4 mm thickness applied above the surface of gel coat which is dully mixed with U.V stabilized pigment to provide resistance to ultra violet light degradation.GI pipe finish-PU paint over two coat of epoxy primer.All complete work as per E/I.
Supply and Installation of SWING Jungle Rumble Play Zone.Design slides, serpentine Slides and covered slides material-Premium quality FRP (fibre reinforce plastic).Roofs-Premium quality FRP (fibre reinforce plastic).Bridges floor -Premium quality FRP (fibre reinforce plastic)-Thickness of slides-3 mm.Thickness of roof-3 mm.Thickness of bridge floor-3 mm.Material for stairs, bridge railing, slides supports.25 mm (B class conforming to IS 1239 latest) PU coated with the layer of thickness of 60 microns.Material for supporting stands.25 mm (B class conforming to IS 1239 latest) PU coated with the layer of thickness of 60 microns.Design -As per representative image - uploaded at QR/Spcn.Product Structure -G.I pipe Stairs – open and closed FRP slider – FRP bridges with pipe railing – huts type FRP roof supported by G.I pipesDimension ± 10 mm-Length - 13500 mm X Width - 6500 mm X Height - 3250 mm.FRP sheets finish -G.P resin of 3 mm to 4 mm thickness applied above the surface of gel coat which is dully mixed with U.V stabilized pigment to provide resistance to ultra violet light degradation.GI pipe finish-PU paint over two coat of epoxy primer.All complete work as per E/I.
Supply and Installation of KID REVOLVING Jungle Rumble Play Zone.Design slides, serpentine Slides and covered slides material-Premium quality FRP (fibre reinforce plastic).Roofs -Premium quality FRP (fibre reinforce plastic).Bridges floor-Premium quality FRP (fibre reinforce plastic).Thickness of slides-3 mm.Thickness of roof -3 mm.Thickness of bridge floor-3 mm.Material for stairs, bridge railing, slides supports-25 mm (B class conforming to IS 1239 latest) PU coated with the layer of thickness of 60 microns.Material for supporting stands-25 mm (B class conforming to IS 1239 latest) PU coated with the layer of thickness of 60 microns.Design-As per representative image - uploaded at QR/Spcn.Product Structure-G.I pipe Stairs – open and closed FRP slider – FRP bridges with pipe railing – huts type FRP roof supported by G.I pipes.Dimension ± 10 mm -Length - 13500 mm X Width - 6500 mm X Height - 3250 mm.Area for play zone -48 feet X 20 feet.FRP sheets finish -G.P resin of 3 mm to 4 mm thickness applied above the surface of gel coat which is dully mixed with U.V stabilized pigment to provide resistance to ultra violet light degradation.GI pipe finish -PU paint over two coat of epoxy primer.All complete work as per E/I.
Supply and Installation of Slide Ladder (Preschool Kit) Virgin Polycarbonate and Multi curve configuration.Slide ladder made up of virgin grade polyethylene plastic-Virgin Polycarbonate.Bolts quality (to provide greater stability to slide)-To provide as per approved advance sample.Overall length of the product (when assembled)-2415mm.Overall width of the product (when assembled)-965mm (Stare supporting base) and 432 mm (Sliding part).Overall height -1143 mm.Length of sliding part-1829 mm.Length of the stair panel-1 270 mm.Step rise of each stair-445 mm long.Minimum overall plastic weight of product-16 Kg.All complete work as per E/I.
Design, fabrication, assembling, wiring & supply, installation, testing & commissioning of MV Panels fabricated out of 2mm thick for structural members (Load bearing members) and 1.6mm thick for door and covers (Non load bearing members) CRCA painted sheet steel in cubicle formation with reinforcement of suitable size angle iron, channels, T irons, flats wherever necessary for large meter boards. Cable gland plates shall be provided at top and bottom both and windows for meter reading, locking arrangement (pad-lock & seal) with wiring upto KWH meter & meter to MCB shall be done by using adequately rated flexible single core copper wire. The boards shall be treated with all anticorrosive process before painting as per standards with final approved shade of powder coated as approved, 2 nos. earthing terminals shall be provided for all panels. The boards shall be suitable for 415 V, 3 phase, 4 wire, 50 Hz supply system. Boards shall be fabricated in length, height, depth etc to match with site conditions.
An approval shall be taken for each panel before manufacturing. Galvanised hardwares with zinc passivation shall be used in fabrication of boards.
Note: The following provisions shall be required to be made in the switchboard detailed below
The Switchboard shall have provision for entry of all PVCA cables/bus duct from the top/bottom as required.
All live accessible parts shall be shrouded and all equipment shall be finger touch proof. The busbar insulation shall be with heat shrinkable sleeves. SMC/DMC shrouds and busbar supports shall be used.
Suitable tinned copper extension links for incoming/outgoing cables shall be provided wherever required
Positive isolation of all breakers.
All fault level breaking capacity indicates shall be IC.S value at 415 volts (ICS = ICU = ICW = 100%).
Space Heater/ light/air filter shall be provided for each vertical compartment
Padlocking facility shall be provided on all outgoing feeders.
All ACB’s shall have all standard accessories such as CT’s, Arc Chute, Safety Shutters etc.
All inter Panel wiring from PLC to DG / Transformer / Bus Couplers as required.
Link and drops from ACB/MCCB shall be designed for full rated current of ACB/MCCB ratings at same current density as of Main Bus Bar
2 nos. GI earth strip throughout the panel.
MAIN LT CUM DG CHANGE OVER PANEL(50 kA)
ELECTRICITY BOARD INCOMER#1
1 Nos. 200 Amps TPN Moulded Case Circuit Breaker (Icu = Ics) with built in Microprocessor based release unit for short circuit , over current and earth Fault
3 Nos. Cast resin CTs of ratio 200 / 5 Amps CL:1 ( For Metering) , 5P20( For protection) , 15 VA.
R-Y-B indication Lamp and Breaker ON-OFF Indication Lamp
Energy Analyser having 30 Days Memory
200A FP AC#3 duty Contactor with ON-OFF indicatio lamp and Contacor ON-OFF pish Button
FUTURE DG INCOMER#2
1 Nos. 200 Amps TPN Moulded Case Circuit Breaker (Icu = Ics) with built in Microprocessor based release unit for short circuit , over current and earth Fault
3 Nos. Cast resin CTs of ratio 250 / 5 Amps CL:1 ( For Metering) , 5P20( For protection) , 15 VA.
R-Y-B indication Lamp and Breaker ON-OFF Indication Lamp
Over Voltage relay (59) And Under Voltage relay (27) with time delay
Energy Analyser having 30 Days Memory
Digital Frequency Meter
200A FP AC#3 duty Contactor with ON-OFF indicatio lamp and Contacor ON-OFF pish Button
Auxiliary contacts required for necessary interlocking of contactor with breaker.
8 Window Annunciation with push Buttons as required
Bus Bar
250A, TPN Al. Bus Bar of suitable length having Current density 1Amp/sq.mm & having high conductivity electrical grade suitable to withstand symmetrical fault level of 16 kA. Neutral busbar shall be of 100% capacity.
Outgoings
3 Nos. 63 Amps TPN Moulded Case Circuit Breaker (Icu = Ics) with built in Thermal Magnetic based release unit for short circuit and over current
3 No. 63A TPN MCB ( Type C)
5 No. 40A TPN MCB ( Type C)
4 No. 40A DP MCB ( Type C)
CAPACITOR PANEL(in Built)
3 Set of 100 /5A for , CL-1.0, 10VA measuring CTs for Metering
1 Set of phase indicating lamps with MCB.
6 step APFCR relay microprocessor based to sense and monitor the system power factor and provide impulses for operation of 6 sequential capacitors circuits
Power factor meter ( digital )
Bus bars
100A, TPN Al. Bus Bar of suitable length having Current density 1Amp/sq.mm & having high conductivity electrical grade suitable to withstand symmetrical fault level of 10 kA. Neutral busbar shall be of 100% capacity.
Outgoings
Main DB with capacitors as described Above
BOLLARD LIGHTING
Supply and installation of 2 kVA UPS with Battary ( Single Phase input and Single Phase output)
EXTERNAL LIGHTING PANEL (OUTDOOR TYPE)
INCOMING
1 No 100 Amp FP Moulded Case Circuit Breaker (25 KA) with 100 Amp 4 Pole Contactor & Timer.
1 Set of phase indicating lamps.
1 Set of ON/OFF indicating lamps with SP MCB.
BUS BARS
200 Amp FP aluminium busbar with coloured heat shrinkable sleeve.
OUTGOING
10 Nos. 25 Amp DP MCB (10 KA)
03 Nos. 63 Amp FP MCB (10 KA)
03 Nos. 63 Amp DP MCB (10 KA)
Panel described as above
Add 18 % GST
Add 1% Labour Cess
M/s Dhananjay Yadav (BID ID -673737)
Raj Enetrprises (BID ID -673757)
SNG Buildtech Private Limited (BID ID -673422)
M/S AMAN ENTERPRISES (BID ID -673679)
UTSAV UDHYOG (BID ID -673572)
RABBANI CONSTURCTION PRIVATE LIMITED (BID ID -673701)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .