Loading…
Loading…
Tender Value
₹2.4 Cr
EMD Value
₹2.7 L
Closing Date
31 Mar 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
GENERAL
15 conditions · 3 needing a document upload
The tenderer must have minimum average annual contractual turnover of 'V/N or V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheet duly certified by the Chartered Accountant/Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The Tenderer should have valid "Electrical License(LT)" issued by Electrical Licensing Board of any state. The license should have been issued on a date prior to the date of tender opening. NOTE: Non submission of valid "Electrical contract License" by the bidder shall result in summarily rejection of his/their bid.
25 conditions · 12 needing a document upload
The tenderer shall clearly specify whether the tender is submitted on his own (Proprietary Firm) or on behalf of a Partnership Firm / company / Joint Venture (JV) / Registered Society / Registered Trust / Hindu Undivided Family (HUF) / Limited Liability Partnership (LLP) etc. The tenderer(s) shall enclose the attested copies of the constitution of their concern, and copy of PAN Card along with their tender. Tender Documents in such cases are to be signed by such persons as may be legally competent to sign them on behalf of the firm, company, association, trust or society, as the case may be. In case of Partnership firm / Joint Venture (JV) / Hindu Undivided Family(HUF) / Limited Liability Partnership(LLP)or Partners of Partnership firm/LLP/etc., the firm should submit the valid Power of Attorney, Partnership Deed/Article of Association/Memorandum of Association, Board of Resolution, Certificate of Incorporation along with the tender. If the firm is sole proprietor firm, the bidder should submit the supporting document of sole proprietorship firm.
tenderer should quote his offer along with GST and other taxes
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
For all the tenders having advertised cost of Rs 10 lakh or above, the contractor shall have the option to take payment from Railways through a letter of credit (LC) arrangement. The tenderer shall affirm having read over and agreed to the terms and conditions of the LC option. ivThe above option of taking payment through LC arrangement, once exercised by tenderer at the time of bidding, shall be final and no change shall be permitted, thereafter, during execution of contract. (The Tenderer should be submit his/their opinion for taking payment through letter of credit (LC) arrangement).
The Bid Security shall be rounded off to the nearest 100. This Bid Security shall be applicable for all modes of tendering. Any firm recognized by Department of Industrial Policy and Promotion (DIPP) as 'Startups' shall be exempted from payment of Bid Security detailed above. Labour Cooperative Societies shall submit only 50% of above Bid Security detailed above. Subject to exemptions provided above document, the tender must be accompanied by a Bid Security as mentioned, failing which the tender shall be summarily rejected.
The tenderer shall submit along with the tender document, documents in support of his/their claim to fulfill the eligibility criteria as mentioned in the tender document. Each page of the copy of documents/certificates in support of credentials, submitted by the tenderer, shall be self-attested/digitally signed by the tenderer or authorized representative of the tendering firm. Self-attestation shall include signature, stamp and date (on each page). Only those documents which are declared explicitly by the tenderer as "documents supporting the claim of qualifying the laid down eligibility criteria", will be considered for evaluating his/their tender.
A certificate may be uploaded along with the offer that the Tenderer(s) has/have gone through all the conditions of contract and rates, specifications, etc. embodied in Indian Railway Standard General Condition of Contract-2022 with correction Slips up to the date of closing of the tender.
1.The Railway reserves the right to verify all statements, information and documents submitted by the bidder in his tender offer, and the bidder shall, when so required by the Railway, make available all such information, evidence and documents as may be necessary for such verification. Any such verification or lack of such verification, by the Railway shall not relieve the bidder of its obligations or liabilities hereunder nor will it affect any rights of the Railway there under. 2.a) In case of any information submitted by tenderer is found to be false forged or incorrect at any time during process for evaluation of tenders, it shall lead to forfeiture of the tender Bid Security besides banning of business for a period of upto five years. (b) In case of any information submitted by tenderer is found to be false forged or incorrect after the award of contract, the contract shall be terminated. Bid Security, Performance Guarantee and Security Deposit available with the railway shall be forfeited. In addition, other dues of the contractor, if any, under this contract shall be forfeited and agency shall be banned for doing business for a period of upto five years.
FAMILARISATION: Tenderer should visit the site of the above works and have familiarized him self/them selves of the working conditions therein in all respects and in particular the following: 1. Topography of the area, 2. Conditions at the site of work, 3. Availability of local labour, both skilled and un skilled and the prevailing labour rate, 4. Availability of Water and Electricity, 5. The existing roads and access to the site of work, 6. Availability of space for putting labour camps, offices, stores, go down, engineering yard etc. NOTE: The FAMILARISATION certificate shall be submitted by the tenderer as per format attached at Annexures.
The tenderer shall clearly specify whether the tender is submitted on his own (Proprietary Firm) or on behalf of a Partnership Firm / company / Joint Venture (JV) / Registered Society / Registered Trust / Hindu Undivided Family (HUF) / Limited Liability Partnership (LLP) etc. The tenderer(s) shall enclose the attested copies of the constitution of their concern, and copy of PAN Card along with their tender. Tender Documents in such cases are to be signed by such persons as may be legally competent to sign them on behalf of the firm, company, association, trust or society, as the case may be. In case of Partnership firm / Joint Venture (JV) / Hindu Undivided Family(HUF) / Limited Liability Partnership(LLP)or Partners of Partnership firm/LLP/etc., the firm should submit the valid Power of Attorney, Partnership Deed/Article of Association/Memorandum of Association, Board of Resolution, Certificate of Incorporation along with the tender. If the firm is sole proprietor firm, the bidder should submit the supporting document of sole proprietorship firm.
The tenderer should go through all the eligibility conditions (like Special Technical Criteria, Standard Technical Criteria, Standard Financial criterial etc.) as mentioned in the document and submit relevant documents and fill the enclosed formats/annexures in support of the condition. All the documents should be in legible format.
1)Upgradation / replacement of dilapidated panels, location boxes, damaged UG Cabling, improvement of shed lighting and associated works in ELS/VSKP.2)Upgradation / replacement of dilapidated panels, location boxes, damaged UG Cabling, improvement of shed lighting and associated works in DLS & NCC/VSKP.
VSKP-ELECTG-25-26-WC-47
VSKP-ELECTG-25-26-WC-47
Open
Works - General
240 Days
Visakhapatnam, Andhra Pradesh
₹0
₹2.7 L
31 Mar 2026
3 Mar 2026
17 Mar 2026
138 items across 2 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 67,49,829.93 | ||
| — | 200.00 | — | — | ||
| Erection, testing and commissioning of Railway supplied LED flood light luminaire with supply & fixing of GI Clamps, hardware & fasteners with connection from nearest Junction Box to make the light fitting functional but except point wiring for illumination of cover shed etc. | — | — | — | 44,292 | |
| — | 220.00 | — | — | ||
| "Fabrication, supply, laying and fixing of S.S perforated cable tray of size 300 mm x 100 mm x 1.5mm thick (12"" x 4"") with cover, SS 202 thickness grade, 16 guage. The sample should be got approved by Sr.DEE. The cable trays should be fixed on the roof, under COP, wall, with suitable clamps, bolts & nuts etc., firmly and rigidly. " | — | — | — | 4,41,625.8 | |
| — | 50.00 | — | — | ||
| Erection, testing and commissioning of Railway supplied LED street light luminaire in SST/GRP pole/GI Ooctagonal pole/bldg/structure. | — | — | — | 10,004.5 | |
| — | 50.00 | — | — | ||
| Supply, erection and commissioning of 5 Meters length GI octagonal pole with all accessories with necessary RCC foundation etc. as per explanatory notes. | — | — | — | 6,28,625.5 | |
| — | 2.00 | — | — | ||
| Design, fabrication, Supply, erection, testing and commissioning of LT Indoor panel board (Double door type, floor/plinth mounted, IP:55 minimum) i.e. Incoming side consisting of 1x630A, 4P ACB, 50KA MDO type (Icu=Ics=50KA), microprocessor release with LCD display, short circuit, over current, earth fault relays, for incoming 1 set of LED type indication lamp (RYB), 1No. 3Ph Digital Voltmeter 0-500V, 1No. 3Ph Digital Ammeter 0-800A, 4Nos. MCBs-6A, 1No. 3phase 4wire Smart Multifunction meter with 630/5A CTs, 800A capacity EC grade copper bus-bar and Outgoing side consisting of 630A capacity EC grade copper bus-bar with 2x400A MCCB 4P (Icu=Ics=36KA) with multifunction meter with 400/5A CTs, 8Nos. MCBs-6A; 4x250A MCCB 4P (Icu=Ics=36KA) with multifunction meter with 250/5A CTs, 12Nos. MCBs-6A; 2x200A MCB 4P (Icu=Ics=36KA) with multifunction meter with 200/5A CTs, 8Nos. MCBs-6A. The panel board shall be fabricated with 2mm thick CRCA sheet steel powder coated with siemens grey, FRP coated etc. as per detailed specification. All MCCBs shall be thermal magentic release provided with spreader and rotary handle. Cu-Al bimetallic strips are to be provided where ever required for connecting aluminium cables. Switchgear Make: Legrand, ABB, Siemens, C&S and L&T. | — | — | — | 11,95,055.14 | |
| — | 2.00 | — | — | ||
| Design, fabrication, Supply, erection, testing and commissioning of LT Indoor panel board (Double door type, floor/plinth mounted, IP:55 minimum) i.e. Incoming side consisting of 1x400A MCCB 4P (Icu=Ics=36KA), 1set of LED type indication lamp (RYB), 3Ph Digital Voltmeter 0- 500V, 3Ph Digital Ammeter 0-500A, 4Nos. MCB-6A with multifunction meter with 400/5A CTs, 630A capacity EC grade copper bus-bar and Outgoing side consisting of 300A capacity EC grade copper bus-bar with 2x250A MCCB 4P (Icu=Ics=25KA), 4x100A MCCB 4P (Icu=Ics=25KA) with 1No. of 63A 4-Pole AC-1 Duty Power Contactor with Digital Time Switch with Astronomical Function & 6A MCBs. All MCCBs shall be thermal magentic release provided with spreader and rotary handle. The panel board shall be fabricated with 2mm thick CRCA sheet steel powder coated with siemens grey, FRP coated etc. as per detailed specification. The panel board shall have required provisions for future installation of 2x100A MCCBs on outgoing side. Cu-Al bimetallic strips are to be provided where ever required for connecting aluminium cables. Switchgear Make: Legrand, ABB, Siemens, C&S and L&T. | — | — | — | 4,64,528.36 | |
| — | 20.00 | — | — | ||
| Design, fabrication, Supply, erection, testing and commissioning of LT Indoor Location Box (Double door type, floor/plinth mounted, IP:55 minimum) i.e. Incoming side consisting of 1x100A MCCB 4P (Icu=Ics=25KA), 1set of LED type indication lamp (RYB), 3Ph Digital Voltmeter 0-500V, 3Ph Digital Ammeter 0-200A, 4Nos. MCB-6A with with multifunction meter with 100/5A CTs, 160A capacity EC grade copper bus-bar and Outgoing side consisting of 2x63A FP MCB with 2x63A Industrial Plug Socket 3Ph+N+E with Plug, 3x32A FP MCB, 2x16A SP MCB. MCCB shall be thermal magentic release provided with spreader and rotary handle. All MCBs shall be 10KA, C-curve. The panel board shall be fabricated with 2mm thick CRCA sheet steel powder coated with siemens grey, FRP coated etc. as per detailed specification. The panel board shall have required provisions for future installation of 2x32A FP MCB on outgoing side. The wiring for MCBs shall be done with suitable size FRLS Copper flexible wire. Switchgear Make: Legrand, ABB, Siemens, C&S and L&T. | — | — | — | 10,79,107 | |
| — | 12.00 | — | — | ||
| Concrete for foundation and plinth in any kind of soil or on concrete floor with M-20 grade concrete for erection of panel boards etc. | — | — | — | 88,000.8 | |
| — | 50.00 | — | — | ||
| Supply, erection, testing and commissioning of All-in-one Solar Steet Light System 25W LED, IP:65 or better, Power output of PV module: >/=75Wp, LiFeP04 Battery capacity >/= 12.8V (nominal), 30 Ah, provided with 2 LED indicators for chaning in progress, deep discharge condition, 7m height pole, nominal bore size/thickness: 65mm/4.5mm, battery box: battery included in the luminaire enclosure and corrosion resistant, with solar PV modules with efficacy >/=75Wp at 16.4+/-0.2 V at STC, necessary control electronics, interconnecting wires/cables, module mounting structures etc. to operate from dusk to dawn etc. as per other conditions in specification similar to model No. Havells 7. Price also include cost of concrete foundation, erection of lighting sytem with grouting bolt etc. for commissioning of the entire system. | — | — | — | 11,18,400 | |
| — | 4.00 | — | — | ||
| Supply & erection of two pole RCBO with two overcurrent protected poles, 240V, C- curve, 30mA with enclosure of Make: Schneider, L&T, Legrand for water purifier. | — | — | — | 12,151.8 | |
| — | 2.00 | — | — | ||
| Supply, fixing, connecting & commissioning of 8-Way TPN DB (8+24 Modules), IP:43, IK:09 with acrylic door similar to Legrand Model No. 507682 with 4x32A FP MCB, 2x25A DP MCB, 2x16A DP MCB complete with wiring etc. All the MCBs shall be 10KA, C-curve. Make: Legrand, ABB, Siemens, C&S and L&T. Price also covers supply of required hardware for erection of DB at location specified by Engineer-in-charge. | — | — | — | 33,780 | |
| — | 1600.00 | — | — | ||
| Single Cable Laying Along the road/Track | — | — | — | 5,91,600 | |
| — | 100.00 | — | — | ||
| Single Cable Laying Across the road/track | — | — | — | 63,179 | |
| — | 1000.00 | — | — | ||
| Laying of Cable in open air | — | — | — | 31,110 | |
| — | 100.00 | — | — | ||
| Laying of cabling by HDD Trench less | — | — | — | 2,94,381 | |
| — | 50.00 | — | — | ||
| Cable Laying Through HDPE Pipe. | — | — | — | 1,436 | |
| — | 600.00 | — | — | ||
| Laying of Railway supplied UG Cable of different size: Along the Road double Cable | — | — | — | 2,46,252 | |
| — | 100.00 | — | — | ||
| Laying of Railway supplied UG Cable of different size: Across the Road/Track double cable | — | — | — | 1,04,581 | |
| — | 20.00 | — | — | ||
| Earthing arrangement | — | — | — | 67,822.2 | |
| — | 50.00 | — | — | ||
| Supply & erection of cable route marker | — | — | — | 4,511.5 | |
| — | 6.00 | — | — | ||
| Supply & erection of outdoor type MS/FRP loop in loop out box made of 1.6mm thick MS sheet/FRP of size 200X150X100mm & 4way stud connector with provision of door in front side with locking arrangement. | — | — | — | 9,067.68 | |
| — | 100.00 | — | — | ||
| Supply and erection of GI flat 50X6mm/25X6mm flat for connection to earth | — | — | — | 6,120 | |
| — | 50.00 | — | — | ||
| Laying of cable along the concrete floor/black top road by cutting floor/black top road without G.I pipe/HDPE Pipe | — | — | — | 4,025 | |
| — | 50.00 | — | — | ||
| Supply & erection of 40 mm Diameter PN-6, PE-80 HDPE Pipe conforming to IS- 4984:2016 and Clamps including cutting and making good the walls etc. | — | — | — | 10,299.5 | |
| — | 100.00 | — | — | ||
| Supply & laying of 6/8/12 SWG GI steel wire | — | — | — | 6,462 | |
| — | 150.00 | — | — | ||
| Supply and fixing of PVC RJ box/ square junction box on wall/roof/truss. | — | — | — | 6,919.5 | |
| — | 100.00 | — | — | ||
| Modular light/fan/ex fan/call bell point wiring (without supply and laying of pipe) with (2x1.5+1x1) Sq.mm FRLSH PVC insulated flexible copper conductor 1100V grade. | — | — | — | 44,512 | |
| — | 5.00 | — | — | ||
| Modular wiring on board 6A 5-pin plug point with (2x2.5+1x1) Sq.mm FRLSH flexible copper conductor 1100V grade. | — | — | — | 2,581.3 | |
| — | 5.00 | — | — | ||
| Concealed/surface wiring (without supply and laying of pipe) for separate plug point 6A 5-pin 250V modular type with (2x2.5+1x1) Sq.mm FRLSH flexible copper conductor 1100V grade. | — | — | — | 5,001.45 | |
| — | 50.00 | — | — | ||
| Concealed/surface wiring (without supply and laying of pipe) for separate plug point 6A+16A 250V modular type with (2x4+1x1.5) Sq.mm FRLSH flexible copper conductor 1100V grade. | — | — | — | 77,578 | |
| — | 50.00 | — | — | ||
| Concealed/surface wiring with (2x6+1x2.5sqmm) FRLSH copper wire 1100 volt grade (without supply and laying of pipe) on truss/roof/wall. | — | — | — | 8,864 | |
| — | 50.00 | — | — | ||
| Concealed/surface wiring with (2x4+1x1.5sqmm) FRLSH copper wire 1100 volt grade(without supply and laying of pipe) on truss/roof/wall. | — | — | — | 5,695.5 | |
| — | 50.00 | — | — | ||
| Concealed/surface wiring with (2x2.5+1x1.0sqmm) FRLSH copper wire 1100 volt grade (without supply and laying of pipe) on truss/roof/wall. | — | — | — | 3,834 | |
| — | 200.00 | — | — | ||
| Supply & laying of PVC rigid Conduit pipe 25mm outer dia (Heavy) on truss with proper saddles/GI clamps. | — | — | — | 14,004 | |
| — | 200.00 | — | — | ||
| Supply & laying of PVC rigid Conduit pipe 32mm outer dia (Heavy) on truss with proper saddles/GI clamps. | — | — | — | 20,450 | |
| — | 20.00 | — | — | ||
| Dismantling of existing Panel Boards / Feeder Pillars / Location Boxes | — | — | — | 3,972.4 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Scopeofwork.pdf
ATTACHMENT
AnnexuresPrescribedforms.pdf
ATTACHMENT
GeneralConditionsofContract2022.pdf GCC of 2022
ATTACHMENT
InstructionstoTenderer.pdf
ATTACHMENT
MAKESANDSPECIFICATIONS.pdf
ATTACHMENT
NIT.pdf
ATTACHMENT
Specialconditions.pdf
ATTACHMENT
TenderFormSheets.pdf
ATTACHMENT
GeneralConditionsofContract2022.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .