| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.9 LAccepted-AOC 0001D ATM HOUSE AIR FORCE NEENA THAPA GORAKHPUR UTTAR PRADESH 273008 UDYAM UP 32 0054752 | GORAKHPUR | UTTAR PRADESH | 273008 | ₹13.9 L Quoted ₹14.4 L | L1 | Accepted-AOC LOWEST QUOTED BIDDER |
| 2 | L2₹18.4 L+₹4.0 L (27.5%)Rejected-Finance | ₹18.4 L+₹4.0 L (27.5%) | L2 | Rejected-Finance NOT THE LOWEST QUOTED BIDDER |
| 3 | L3₹20.5 L+₹6.1 L (42.2%)Rejected-Finance | ₹20.5 L+₹6.1 L (42.2%) | L3 | Rejected-Finance NOT THE LOWEST QUOTED BIDDER |
| Sl No | Description | Qty | Unit | om sai enterprises L1 | M/s.Santosh Kotarki L2 | M/S Bhagyawanticonstruction L3 |
|---|---|---|---|---|---|---|
| 1.00 | Taking up or down MS ERW steel tubing of 150 mm dia with fittings complete including cutting the pipe complete all as specified and as directed.
Note : Excavation, removal and RFR will be measured and paid seprately under the respective items. | 48 | RM | 60 ₹2,880 Lowest | 80 ₹3,840 | 140 ₹6,720 |
| 2.00 | Supply and fix MS ERW pipe line suitable for existing fire fighting system of dia 150 mm bore , bearing ISI Mark , along with the fittings in trenches complete all as specified and as directed.
Make : Jindal /Tata / BST / Advance Steel Tubes | 36 | RM | 1,000 ₹36,000 Lowest | 1,000 ₹36,000 Lowest | 1,000 ₹36,000 Lowest |
| 3.00 | Supply and fix MS ERW pipe line suitable for existing fire fighting system of dia 200 mm bore , bearing ISI Marke , along with the fittings in trenches complete all as specified and as directed.
Make : Jindal /Tata / BST / Advance Steel Tubes | 6 | RM | 1,500 ₹9,000 Lowest | 2,500 ₹15,000 | 1,800 ₹10,800 |
| 4.00 | Supply and fix MS ERW pipe line suitable for existing fire fighting system of dia 300mm bore , bearing ISI Marke , along with the fittings in trenches complete all as specified and as directed.
Make : Jindal /Tata / BST / Advance Steel Tubes | 6 | RM | 1,800 ₹10,800 Lowest | 3,500 ₹21,000 | 1,900 ₹11,400 |
| 5.00 | M&L applying one coat of synthetic enamel painting of postal red colour on iron / steel surface of any description over 10cm in width or girth, not other wise described including preparation of old painted surface for free from dust and deposits all as specified and directed and directed.
Make- Asian / Nerolac / Berger. | 150 | Sqm | 80 ₹12,000 Lowest | 100 ₹15,000 | 100 ₹15,000 |
| 6.00 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5m in depth for and taking out / for laying underground pipes extra and getting out in soft / loose soil, complete all as specified and as directed. | 20 | Cum | 300 ₹6,000 | 320 ₹6,400 | 180 ₹3,600 Lowest |
| 7.00 | Returning filling, incl spreading, levelling, watering & well ramming in layers n.exc 25 cm in soft/loose soil, complete all as specified and as directed. | 16 | Cum | 120 ₹1,920 | 100 ₹1,600 | 80 ₹1,280 Lowest |
| 8.00 | Removing excavated soil to a distance not exc 50 m & depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and as directed. | 4 | Cum | 150 ₹600 | 300 ₹1,200 | 100 ₹400 Lowest |
| 9.00 | M&L for inspection of fire alarm control panels and its associated systems located at different places in technical area by a qualified technician and rectifying the faults complete all as specified and as directed. The inspection and fault rectification includes :-
(a) Open and check the control panels for any visible damage,dirt or any obstructions.
(b) Review of any unacknowlwdged events.
(c) Check the entire system power supply.
(d) Check the backup batteries for any signs of corrosion, leakage or swelling.
(e) Check the wiring/communication faults between the FACP and a device/zone.
(f) Check the damaged/dirty detectors.
(g) Check the software/programming/configuration errors.
(h) Trace and isolate the fault.
(j) Replace the components if required.
(k) Reset the entire system.
Note :-
(i) Batteries, Analogue Addressable flame detector, Analogue Addressable Multi Sensor (Smoke -Heat), Addressable manual call point and Addressable electronic sounder cum strobe will be measured and paid under respective item of schedule.
(ii) If any software/programme update is required, the same will be done without any additional cost. | 10 | Each panel | 4,000 ₹40,000 Lowest | 6,500 ₹65,000 | 4,000 ₹40,000 Lowest |
| 10.00 | Disconnection and removing the unservicable ,Supply and fixing of Fire alarm control panel inteligent, addressable, microprocessor based single loop panel with 1 loop card,each loop capable of handling 99 detectors and 99 devices per loop on a loading on 75%maximum loading with suitable battery backup for 72 Hours in normalcondition and 3 hours during alarm condition and shall be expandable 4 loop capacity.The panel shall also have networking capacity via RS 485/RS 232 or TCP IP Card.The panel which shall be having speech processor for sending out recordered information .complying with BS EN 54 ,or UL,FM,LPCB complete all as specified and directed. This panel act as Slave panelsat various location inside technical area complete all as specified and as directed.
Make: Honeywell / Siemens / Hochiki / Notifier / Ceasefire / Morley | 1 | Each | 1,60,000 ₹1,60,000 Lowest | 2,60,000 ₹2,60,000 | 1,60,000 ₹1,60,000 Lowest |
Tender Value
₹22 L
EMD Value
₹44,000
Closing Date
14 Aug 2025, 6:00 pmClosed
CWE (AF) Secunderabad
CWE (AF) Secunderabad
MAINT AND REPAIRS TO FIRE FIGHTING SYSTEM AND FIRE ALARM AND CONTROL SYSTEM INCL REPAIR TO FIRE HYDRANTS, HOSE REELS INCL CONNECTED INFRA AT AFS BIDAR
2025_MES_721044_1
85656/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) Bidar
As per NIT
9 documents required · 9 mandatory
₹500
GE (AF) Bidar
₹44,000
Yes
28 Aug 2025
17 Jul 2025
16 Aug 2025
17 Jul 2025
14 Aug 2025
31 Jul 2025
17 Jul 2025 - 29 Jul 2025
Amount
Taking up or down MS ERW steel tubing of 150 mm dia with fittings complete including cutting the pipe complete all as specified and as directed. Note : Excavation, removal and RFR will be measured and paid seprately under the respective items.
Supply and fix MS ERW pipe line suitable for existing fire fighting system of dia 150 mm bore , bearing ISI Mark , along with the fittings in trenches complete all as specified and as directed. Make : Jindal /Tata / BST / Advance Steel Tubes
Supply and fix MS ERW pipe line suitable for existing fire fighting system of dia 200 mm bore , bearing ISI Marke , along with the fittings in trenches complete all as specified and as directed. Make : Jindal /Tata / BST / Advance Steel Tubes
Supply and fix MS ERW pipe line suitable for existing fire fighting system of dia 300mm bore , bearing ISI Marke , along with the fittings in trenches complete all as specified and as directed. Make : Jindal /Tata / BST / Advance Steel Tubes
M&L applying one coat of synthetic enamel painting of postal red colour on iron / steel surface of any description over 10cm in width or girth, not other wise described including preparation of old painted surface for free from dust and deposits all as specified and directed and directed. Make- Asian / Nerolac / Berger.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5m in depth for and taking out / for laying underground pipes extra and getting out in soft / loose soil, complete all as specified and as directed.
Returning filling, incl spreading, levelling, watering & well ramming in layers n.exc 25 cm in soft/loose soil, complete all as specified and as directed.
Removing excavated soil to a distance not exc 50 m & depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and as directed.
M&L for inspection of fire alarm control panels and its associated systems located at different places in technical area by a qualified technician and rectifying the faults complete all as specified and as directed. The inspection and fault rectification includes :- (a) Open and check the control panels for any visible damage,dirt or any obstructions. (b) Review of any unacknowlwdged events. (c) Check the entire system power supply. (d) Check the backup batteries for any signs of corrosion, leakage or swelling. (e) Check the wiring/communication faults between the FACP and a device/zone. (f) Check the damaged/dirty detectors. (g) Check the software/programming/configuration errors. (h) Trace and isolate the fault. (j) Replace the components if required. (k) Reset the entire system. Note :- (i) Batteries, Analogue Addressable flame detector, Analogue Addressable Multi Sensor (Smoke -Heat), Addressable manual call point and Addressable electronic sounder cum strobe will be measured and paid under respective item of schedule. (ii) If any software/programme update is required, the same will be done without any additional cost.
Disconnection and removing the unservicable ,Supply and fixing of Fire alarm control panel inteligent, addressable, microprocessor based single loop panel with 1 loop card,each loop capable of handling 99 detectors and 99 devices per loop on a loading on 75%maximum loading with suitable battery backup for 72 Hours in normalcondition and 3 hours during alarm condition and shall be expandable 4 loop capacity.The panel shall also have networking capacity via RS 485/RS 232 or TCP IP Card.The panel which shall be having speech processor for sending out recordered information .complying with BS EN 54 ,or UL,FM,LPCB complete all as specified and directed. This panel act as Slave panelsat various location inside technical area complete all as specified and as directed. Make: Honeywell / Siemens / Hochiki / Notifier / Ceasefire / Morley
Disconnection and removing the unservicable copper cable and supply, laying & testing PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 1.5 sq mm, 2 core, 1100 Volts grade.with required accessories complete all as specified and as directed. Make: Finolex / Polycab / Havells
Disconnection and removing the unservicable analogue Addressable flame detector and Supply, Installation, Testing & Commissioning of Analogue Addressable flame detector with UV/IR detection. LPCB approved,FM,CE complaince,complete all as specified and as directed.. Make : Honeywell / Siemens / Hochiki / Notifier / Ceasefire / Morley / AGNI
Disconnection and removing the unservicable Addressable manual call point and Supply and fixing of Addressable manual call point resettable type including transparent safety cover with back box complete all as specified and directed. Make : Notifier
Disconnection and removing the unservicable Addressable electronic sounder cum strobe and Supply and fixing of Addressable electronic sounder cum strobe with back box,32 tone selction, EN 54 complete all as specified and as directed. Make: Notifier
Disconnection and removing the unservicable Siren and Supply, Installation, testing & commissioning of Siren 2.0 KM Range Single Honeywell stage complete all as specified and as directed. Make : Khaitan
Disconnection of duracell Lithium CR 123A batteries from the Sensor and Supply 3 Volt lithium battery complete all as specified and as directed. Make : DURACELL
Disconnection and removing the pipe line connections connected to the Diesel Engine of Capacity 125 KW /167 HP (at Parachute Building), Type 4R 1040, Make :- KOEL unit carefully for finding out the defects and Servicing/ repairing the same and including Replacement of unserviceable Fuel Filters, Air filters, Oil filters, Fan belt, Hose Pipe sets, Engine Oil, Coolant, Bearings complete and refixing the same in its original position couple with the pumpset and connecting the pipe line testing and commisioning complete all as specified and as directed. Note : All the misc items and Fuel Filters, Air filters, Oil filters, Fan belt, Hose Pipe sets, Engine Oil, Coolant, Bearings not covered under the scope of work but required for satisfactory completion of job is deemed to be included in the unit rate.
All as per Item No 18 here-in-above but of capacity 58 KW/79 HP (at New ATC Building) complete all as specified and as directed.
All as per Item No 18 here-in-above but of capacity 44.2KW/60 HP (at Air Field FF Pump house) complete all as specified and as directed.
Disconnection and removing the Fire Fighting Pumps of Capacity 167 to 170 HP, Head 90 Mtr, Discharge 4590 LPM connected to the Diesel Engine of Capacity 125 KW /167 HP (at Parachute Building) alongwith connections and overhauling the same complete including reneuwal of worn out bearings, metalling & Polishing the shaft, Coupling Unit, Oil Seal, Gland, Impeller Sleeves, Impeller lock nuts, complete and re-fixing the pump in its original postion after completion of repairs and overhauling connecting the pipelines testing and commisioning complete all as specified and as directed. Note : (1) All the misc items not covered under the scope of work but required for satisfactory completion of job is deemed to be included in the unit rate.
All as per Item No 21 here-in-above but of capacity 50 to 60 HP (at Air Field FF Pump house) complete all as specified and as directed.
All as per Item No 21 here-in-above but of capacity 79 HP (at New ATC Bldg) complete all as specified and as directed.
Disconnection and removing the Fire Fighting Jockey Pumpset of Capacity 10 to 15 HP, 440V connected to the Fire Fighting system (at Parachute Building, Air Field FF Pump house & New ATC Bldg) alongwith connections and overhauling the same complete including reneuwal of worn out bearings, metalling & Polishing the shaft, Coupling Unit, Oil Seal, Gland, Impeller Sleeves, Impeller lock nuts complete and re-fixing the pump in its original postion after completion of repairs and overhauling connecting the pipelines testing and commisioning complete all as specified and as directed :- Note : All the misc items not covered under the scope of work but required for satisfactory completion of job is deemed to be included in the unit rate.
S&F in replacement of pressure switch of suitable calibration for automatic operation of the system complete with all accessories complete all as specified and as directed. Make: Danfoss / Indfoss
Disconnection and taking down unserviceable double headed yard hydrant valve 63mm and replacing the unserviceable End Cap, Lugs Grip and Rubber Washer, checknut and Polishing the hydrant carefully and refixing the same after repairs in its original position complete all as specified and as directed. Make :- Getec / Newage / Padmini
All as per Item No 26 here-in-above but Single headed yard hydrant valve 63mm dia complete all as specified and as directed.
Disconnection and taking down unserviceable double headed yard hydrant valve 63mm and S&F New Double headed yard hydrant valve 63mm instantatenous with operating wheels, end caps and securing chains ISI Marked complete alongwith necessary fixing materials requried for completion of job complete all as specified and as directed. Make :- Getec / Newage / Padmini
All as per Item No 28 here-in-above but Single headed yard hydrant valve 63mm dia complete all as specified and as directed.
Taking down unserviceable hose reel drum alongwith hose including S&F new hose reel drum with 19mm dia 36.0 Mtr long re-inforced rubberised fabric hose including 6.35mm dia nozzle with a ball valve swing type, recessed as per sample complete, hose (BIS mark) conforming to IS : 636, type II and complying to IS : 903 as replacement at requirement basis of fire fighting area complete all as specified and as directed. Make :- Getec/Newage/Padmini
Taking down unserviceable corroded/broken Hose Box and S&F new Hose Box made of 18 gauge MS Sheet 800 x 600 x 250mm with double door with 4mm thick glass and door frame made of 16 gauge MS Sheet painted with fire red oxide and brilliant white inside the box complete all as specified and as directed. Make :- Getec/Newage/Padmini
M&L for plain cement concrete for foundation of fire hose box 15 cm over lap on all side, filling and mass concrete Type B1, 1:2:4 mix using 20 mm graded aggregate complete all specified and directed. Note :- Quoted rate deemed to include the cost of excavation and earth work etc.
M&L for rendering 15mm thick on fair faces of brick work or concrete surface in CM 1:4 surface finished even and fair complete all as specified and as directed.
Disconnection and removing unserviceable sprinklers from any height of the building carefully and S&F New Sprinkler universal type, quick/ early response type as per IS : 15105/TAC guidelines, 68 degree temperature rating complete in Hangers and other technical buildings complete all as specified and as directed. Make :- 7 Star/Tyco/Getech
Disconnection and removing the AFPP Oscillating type system Foam Monitor of capacity not less than 1800 LPM and servicing/repairing of the Foam Monitoring unit complete including renewal of unserviceable Parts, check nuts, monitoring system, cover, proposing devicer by specialist and dual jet and re-fixing the same in its original position complete all as specified and as directed. Make :- Getec/Newage/Padmini
Disconnection and removing the unserviceable AFPP Oscillating type Foam Monitor system S&F New AFPP Oscillating type foam monitor system unit of capacity not less than 1800 LPM complete all as specified and as directed. Make :- Getec/Newage/Padmini
Disconnection and removing the AFPP Oscillating type system Water Monitor of capacity not less than 1800 LPM and servicing/repairing of the Water Monitoring unit complete including reneuval of unserviceable Parts, check nuts, monitoring system and cover and re-fixing the same in its original position complete all as specified and as directed. Make :- Getec/Newage/Padmini
Disconnection and removing the unserviceable AFPP Oscillating type Water Monitor system S&F New AFPP Oscillating type Water monitor system unit of capacity not less than 1800 LPM complete all as specified and as directed. Make :- Getec/Newage/Padmini
Disconnection and removing the unservicable Sluice Valve 80mm dia and S & F Sluice Valve 80mm dia, IS-14846, PN 1.6 brass/stainless steel spindle with hand wheel head, screwed both ends for GI Pipe 80 mm dia complete all as specified and as directed. Make: Kirlosker/Upadhyaya/RMCO/Kartar
All as per item No 39 here-in-above but of capacity 100mm dia sluice valve complete all as specified and as directed.
All as per item No 39 here-in-above but of capacity 150mm dia sluice valve complete all as specified and as directed.
Disconnection and removing the unservicable Non Return Valve 150mm dia and S & F Non Return Valve 150mm dia, both end flanged including provn of new gasket and nuts, bolts and washers and fixed complete all as specified and directed. Make: Kirlosker/Upadhyaya/RMCO/Kartar
Disconnection and removing the unservicable CI Foot Valve and S & F CI Foot valve 100mm dia with all fittings including flanges, leather washer, fasteners for fitting such as necessary size nut bolt and washer, rubber packings / joining materials complete including taking down the old unsv one complete all as specified and as directed. Make: Kirlosker/Upadhyaya/RMCO/Kartar
All as per item No 43 here-in-above but of capacity 150 mm dia CI Foot valve complete all as specified and as directed.
All as per item No 43 here-in-above but of capacity 200 mm dia CI foot valve complete all as specified and as directed.
Disconnection and removing the unservicable CI Butterfly Valve 80mm dia and S&F CI Butterfly Valve 80mm dia, (Wafer Type) PN 1.6 Brass / Stainless steel spindle with hand wheel head, screwed both ends, ISI Marked complete all as specified and directed. Make: Kirlosker / Upadhyaya / RMCO / Kartar / Audco
All as per item No 46 here-in-above but of capacity 100mm dia complete all as specified and directed.
All as per item No 46 here-in-above but of capacity 150mm dia complete all as specified and directed.
All as per item No 46 here-in-above but of capacity 200mm dia complete all as specified and directed.
Disconnection and removing the U/S gate valve 50 mm dia and S & F Gun metal globe or gate valve 50 mm dia with iron wheel head, screwed both ends for GI Pipe complete all as specified and as directed.
Disconnection and removing the unservicable power contactor carefully from Panel board and S&F new power contactor 160 Amp Capacity , 440 V comprising of all accessories type MNX-110 complete all as specified and as directed. Make : GE / Seimens / L&T.
Disconnection and removing the unservicable power contactor carefully from Panel board and S&F new 3 pole power contactor series CK75CA311 of capacity 185Amp, 440V comprising of all accessories complete all as specified and as directed. Make : GE / Seimens / L&T.
Disconnection and removing the unservicable power contactor carefully from Panel board and S&F new 3 pole power contactor series CL12A311M of capacity 160Amp, 440V comprising of all accessories complete all as specified and as directed. Make : GE /Seimens/L&T.
Disconnection and removing the unservicable power contactor carefully from Panel board and S&F new power contactor 25 to 32 Amp Capacity , 440 V comprising of all accessories complete all as specified and as directed. Make : GE / Seimens / L&T.
Disconnection and removing the unserviceable MCCB 63 Amps capacity and supply and fix MCCB 3 pole 16 KA 63 Amps 440 volts MCCB along with fixing arrangements complete all as specified and as directed. Make : L&T or its equivalent in Legrand / ABB
Disconnection and removing the unserviceable MCCB 200 Amps capacity and supply and fix MCCB 3 pole 36 KA 200 Amps 440 volts MCCB along with fixing arrangements complete all as specified and as directed. Make : L&T or its equivalent in Legrand / ABB
Disconnection and removing the unserviceable pressure guage and S&F Pressure gauge 8"dial 0-21 kgs rating ISI Marked complete all as specified and as directed.
Disconnection and removing the unserviceable pressure guage and S&F Pressure gauge 4"dial 0-21 kgs rating ISI Marked complete all as specified and as directed.
Disconnection,Supply and fixing in existing LT panel on load switch fuse unit 200 A 4 pole AC,415 Volt with HRC Fuses without enclosure complete all as specified and as directed . Make :GE/Havells/L&T
Disconnection,Supply and fixing in existing LT panel on load switch fuse unit 400 A 4 pole AC,415 Volt with HRC Fuses without enclosure complete all as specified and as directed. Make :GE / Havells / L&T
Taking down radiators by unscrewing carefully nut bolts, and transporting to workshop for cleaning washing of blocked water cooling pipe and repair and soldeing/ welding if any including necessery hard ware material like rubber bush and taking back to site. Fixing in original portion of the Diesel engine set for capacities of 125 KW to 44.2 KW complete all as specified and as directed. Make :- Kirloskar
Supply and fixing oil pressure guage as per existing sample & capacity including removing old oil pressure gauge complete all as specified and as directed. Make: Yankey / Pricol
Supply & fixing temprature gauge oil/water in the diesel engine including taking down old temp guage complete all as specified and as directed. Make :- Yankey / Pricol
M/s.Santosh Kotarki (BID ID -3387690)
M/S Bhagyawanticonstruction (BID ID -3393393)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .