Superintending Engineer
Superintending Engineer, P H Circle, Thrissur
KIIFB WSS to Chazhur,Thaniam and Anthikad Panchayath Construction 12 MLD WTP,250mm DI RWPM ,Renovation of well cum pumphouse,RW and CW Pumpset,250KVA 11KV 433V Transformer,SCADA,12LL OHSR,5.5LL sump cum PH,Pressure Filter,Road restoration works etc.
2019_KWA_311619_1
07/SE/PHC/TSR/2019-20
Open Tender
Civil Works - Water Works
540 days
Chazhur-Anthikkad
Please refer Tender documents.
8 documents required · 8 mandatory
₹16,800
online
₹5 L
Yes
P H Circle, Thrissur
17 Mar 2020
22 Oct 2019
11 Nov 2019
22 Oct 2019
7 Nov 2019
22 Oct 2019
25 Oct 2019
Amount
Package I – Construction and commissioning of 12 MLD WTP at Chazhur, Supplying, laying, testing and commissioning 250mm DI RWPM – 1100m, Renovation of well cum pumphouse (2 Nos), Supply, erection, testing and commissioning of RW and CW pumpset, 250 KVA, 11 KV/433V transformer, road resoration works .SCADA automation , Construction of 12LL OHSR, 5.5 LL capacity sump, pressure filter-2nos
Raw water pumping main - supplying 250mm dia.DI K9 Pipe conforming to IS 8329/2000 - 1122m, 200mm dia DI K9 pipe - 11m, 250mm dia D/F DI Pipe-6m, 250mm CI non return valve confirming to IS 5312 part 1 1984, PN 1.0 - 1 no., 200 mm CI double flanged sluice valve with hand wheel, PN 1.6 - 3 nos., 250mm CI double flanged sluice valve with hand wheel, PN 1.6 - 2 nos, 80mm kinetic air valve with flanges type DS2 conforming to IS 14845/2000- 3 nos, 80mm CI double flanged sluice valve with cap, PN 1.0- 3 nos, 80mm GI pipewith fittings - 3m. including all specials like valves, reducers, tail pieces, bends, tees, DI/MJ collar, etc. complete required for the satisfactory completion of the work as per the direction of Departmental Officers in Charge and scope of work and conveying, laying, cutting (using cutters), welding, grinding, jointing (push on/flanged joints), testing, commissioning the pumping main (DI pipe/valves and specials) according to the alignment, dismantling RR/concrete structures, other hurdles if any on the alignment and reconstructing the same after construction as per direction of the departmental officers in charge, including excavating trenches in all kinds of soil and refilling the trenches after laying with consolidating each layer, cutting the bituminous / concrete roads with cutting machine for pipe lines including all pipes/specials, fencing, bailing out water, labour for cutting DI pipe steel saw, providing push on joints for DI Pipes including testing of joints and cost of rubber gaskets, Providing lead caulked joints for pipes and specials including testing of joints, providing flanged joints and testing, testing DI pipes with potable water to requiresd test pressure, fabricating MS pipe, specials,mechanical joint with flanged tail pieces/flanged bend of suitable size with MS plate of 10mm thick, welding, grinding, providing wrapping coat using coal tar on outside of MS pipe of 10mm thickness, conveying and fixing GI Pipes complete with GI fittings including trenching and refilling etc, providing anchor blocks/guide blocks wherever necessary (required no.) using cement concrete mix 1:2:4,Construction of valve chambers-9nos of suitable size including earth work excavation in all kinds of soil, providing and laying in position cement concrete upto plinth level in CC 1:3:6, providing and laying in position RCC upto plinth level in CC 1:1.5:3 for cover slab, providing and laying in position RCC upto plinth level in CC 1:2:4 for base slab,side wall, and anchor blocks etc., centering, shuttering, strutting, propping, removal of form etc for bottom slab, side slab, cover slab etc. complete. including cost of reinforcement bars of TMT grade Fe-500D or more for RCC works, Plastering 12mm thick the side walls with cement mortar 1:3 etc. complete required for the completion of the work as per the direction of departmental officers in charge and scope of work.
Design, construction, testing and commissioning of 12MLD capacity Water Treatment Plant with SCADA automation,12LL OHSR and 5.5LL sump (Sump cum Pump House cum Filter House of 12MLD WTP) - Construction of 12 MLD conventional type WTP at existing WTP compound in Chazhur Panchayath . The work includes design, construction and commissioning of SCADA operated 12.00 MLD WTP (Details of automation shall be given in the scope of work) with all associated structures like Aerator, Flash mixer, Clarifloculator, rapid sand gravity filter with filter house, wash water tank, chemical house, Chlorine room with Chlorinator and 2 Nos of chlorine tonners,clear water sump, clear water pump house cum panel board room ,compressor room with compressors, supplying and erection of all mechanical and electrical equipments ,supply and installation of Electromagnetic flowmeter, supply and erection of satinless steel metal box for housing the transmitter and battery of Eelctromagnetic flow meter etc. complete in all respect. The WTP should have a well-equipped lab with all necessary lab equipments. The necessary safety equipments and hoisting system for chemicals and lightening arrester, ladders to wash water tank and sump should be supplied as part of the work. All internal electrical and plumbing work is also part and parcel of the work. Common RCC wash water pit of minimum size 3.60 x 3.60x 1.15 m has to be constructed in the WTP compound and the drainage water from the slurry pit should be disposed to the nearby drainage facility. The site should be levelled and easy access to all the major components of the WTP should be ensured by building internal access road either by concrete or by paving tiles for a length of 75m. The work includes construction of compound wall around WTP for 120 m and construction of drain for 210 metre as per direction of departmental officers. The maximum head loss in the plant should be limited as per CPHEEO manual. The existing 350 mm DI K9 pumping main has to be connected to the aerator as per scope of work and direction of departmental officers in charge and Design, construction, testing and commissioning of 12 Lakhs litre capacity OHSR including supplying of 250mm DI K 9 D/F pipe-112m, 300mm DI K 9 D/F pipe-9m, 400mm DI K 9 D/F pipe-32m, 150mm DI K 9 pipe- 36m, 250mm DI K 7 pipe- 80m, 250mm DI K 9 pipe-20m,300mm DI K 9 pipe-15m,400mm DI K 9 pipe-50m,400mm DI K 7 pipe-75m, D/F sluice valves with hand wheel PN 1.6 of size 150mm- 1no, 250mm sluice vale with hand wheel PN 1.6- 7nos ,300mm sluice vale with hand wheel PN 1.6-1no, 400mm sluice vale with hand wheel PN 1.6- 2nos, 300mm Non return valve - 1No and specials like valves, reducers, tail pieces, bends, tees, wall casting pipes, DI/MJ collar, etc complete for the satisfactory completion of work as per departmental officers in charge and scope of work including providing pile foundation as per the soil condition with all charges of boring,testing,demolishing,etc. complete as per scope of work,providing and laying RCC of mix M30/richer mixes, providing and laying RCC of mix 1:2:4,centering, shuttering, strutting, propping, removal of form etc, 12mm plastering finished with a floating coat of mix 1:3 with water proofing compound, finishing walls with two or more coats of water proofing cement paint of required shade/texture including priming coat interior/exterior, steel reinforcement of TMT grade Fe-500D or more including straightening,cutting,bending,placing in position and binding etc, providing steel work welded in built up sctions/framed work for ladders and handrails, providing vent hole with PVC vent cowl with all materials, supplying and fixing manholes of required size, filling water for testing, lettering with black japan paint, joining (push on/flanged joints), supplying and fixing electro magnetic flow meter of size 300mm- 2nos confirming to protection level IP-68 for flow sensers and IP-67 for transmitting tested and calibrated at FCRI,Palakkad and test certificate should be produced with minimum 24Hrs battery back up capacity, supply and erection of stainless steel metal box for housing the transmitter and battery, excavating trenches in all kinds of soil,fencing, labour for cutting, testing with potable water to the required test pressure, supplying and fixing mechanical water level indicator-1no, providing and fixing lightning protection system-1no, fabricating and fixing MS mechanical joint with flanged tail pieces using MS plate of required thickness etc,Construction of valve chambers- 14nos of suitable size including earth work excavation in all kinds of soil, providing and laying in position cement concrete upto plinth level in CC 1:3:6, providing and laying in position RCC upto plinth level in CC 1:1.5:3 for cover slab, providing and laying in position RCC upto plinth level in CC 1:2:4 base slab, side wall etc., centering, shuttering, strutting, propping, removal of form etc for bottom slab, side slab, cover slab etc. complete. including cost of reinforcement bars of TMT grade Fe-500D or more for RCC works, Plastering 12mm thick the side walls with cement mortar 1:3 complete for the satisfactory completion of the work and maintaining for a period, as per the directions of Departmental officers in charge and scope of work.
Supply, erection, testing, commissioning of pressure filter at Chazhur WTP and interconnection works with Pumping mains and delivery to sump and back wash water to existing scour pipe and Demolishing of Existing Aerator and Clarifilter(2nos) - Supply, erection, testing, commissioning of pressure filter of dia-2200mm. Height- 1500mm using MS plate Dishes, shell of thickness 10mm with suitable MS pipes and Butterfly valves for the filter of capacity 1 MLD/day in 20 Hrs using graded pebbles,coarse & fine sand filter medias, anti-corrossive & red oxide paint protection inside & outside respectively with maximum working pressure -10kg/cm2, minimum working pressure - 1.5kg/cm2 at WTP site at the time of construction period of WTP for providing water supply including interconnection with pumping mains and delivery to sump and back wash water to existing scour pipe using 250mm DI K 9 pipe-50m,200mm DI K 9 pipe- 12m,100mm DI K 9 D/F pipe- 2m, 250mm CI double flanged sluic valve- 5nos,200mm CI double flanged sluice valve- 1No including all specials like valves, reducers, tail pieces, bends, tees, DI/MJ collar, wall casting pipe etc. complete required for the completion of the work as per direction of Departmental Officer in Charge and scope of work by conveying, laying, jointing, testing, commissioning of the interconnection with the pumping main (DI pipe/valves and specials) according to the alignment, including excavating trenches in all kinds of soil, ordinary rock, fabricating MS flanges/pipes using MS plate of suitable thickness, cutting (using cutters),welding,grinding, joining (push-on/flanged joints), interconnecting the pressure filter with existing pumping main inlet and outlet with all cost of materials etc. complete required for the completion of the work as per the direction of the departmental officers in charge and scope of work. Demolishing of existing aeretor cum filter unit- 2Nos at Chazhur WTP site including demolishing, dismantling and disposal of RCC work mechanicaly/manually, CI/GI pipes, valves and excavation,refilling trenches after taking out the pipes, disposal of unserviceable demolished material including loading,transporting,unloading beyond 50m lead and filling available earth excluding rock by consolidating in layers not exceeding 20cm, clearing the site, felling trees at existing WTP & OHSR compound for the completion of the work as per the direction of the departmental officers in charge and scope of work.
Renovation of existing intake well cum pump houses at Illickal and Kolothumkadavu Renovation of existing two intake well cum pumphouses including demolishing, dismantling and disposing R.C.C work, repairing the existing plasters of thickness 12mm to 20mm in CM 1:4, finishing wall with water proofing cement paint of required shade, providing, fixing and removing double scaffolding system (cup lock type) including all charges, providing and laying machine batched machine mixed design mix M-25 grade cement concrete for hand rail post, ramp etc, providing and laying RCC 1:1.5:3 for cover slab etc, centering, shuttering, strutting etc. and removal of form for RCC works, steel reinforcement of grade Fe 500D or more for R.C.C work including straightening,cutting,bending,placing in position etc complete, 12mm cement plaster finished with floating coat of cement of mix 1:4,plastering the top of roof slab 12mm thick with CM 1:3, randum rubble masonry with hard stone using cm 1:6 including levelling up with cement concrete 1:6:12 wherever necessary, providing and fixing glazed shutters for windows,ventilator etc complete, providing and fixing hand rail with GI pipes and applying priming coat, steel work incuding welding for providing gratings in existing spigot / bell mouth of the intake well leading pipe, for ladders etc complete, engaging drivers with all required equipments for fixing gratings, providing and fixing MS doors, painting with aluminium paint, acrylic emulsion paint, priming coat with primer etc complete wherever necessary as per the direction of departmental officer in charge, providing and laying vitrified floor tiles of size 500 X 500 mm in CC 1:4/1:3 including grouting the joins with white cements and matching pigments, cement concrete flooring in 1:2:4 and finishing the same etc.,construction of toilet, soakpit,drainage,water supply connection,yard lighting etc. at the intake well site complete complete as per the direction of the departmental officers in charge and scope of work.
Design,supply,erection, testing and commissioning of VT Raw water motor pumpset- 2Nos at Illikkal and Kolothumkadavu existing Intake well cum Pump Houses Supply, erection, testing and commissioning of VT Raw water motor pump set having a discharge of 100 lps against an approximate total head of 50m- 2nos (1 as standbye) at Illikkal and VT Raw water motor pump set having a discharge of 51 lps against an approximate total head of 35m - 2nos (1 as standbye) at kolothumkadavu , with required length of suction pipe, starter, panel board, cabling works, earthing, capacitors, valves, suction, delivery connections and all necessary accessories including power allocation charges, requied RCC works for providing anchor block in bend portion, foundation block etc including formwork,watering, curing etc, with additional warranty of 1year complete as per direction of departmental officers in charge and scope of works.
Design,supply,erection and commissioning of clear water centrifugal motor & pumpsets for Chazhur Zone and Thanniyam and Anthikkad Zone at Sump of WTP Supply, erection, testing and commissioning of clear water centrifugal motor pump set having a discharge of 48.61 lps against an approximate total head of 30m - 2nos (1 as standbye) for Chazhur zone and clear water centrifugal motor pump set having a discharge of 90.28 lps against an approximate total head of 38m - 2nos (1 as standbye) for Thanniyam and Anthikkad zone , with required length of suction pipe, starter, panel board, cabling works, earthing, capacitors, valves, suction, delivery connections and all necessary accessories including power allocation charges, requied RCC works for providing anchor block in bend portion, foundation block etc including formwork,watering, curing etc, with additional warranty of 1year complete as per direction of departmental officers in charge and scope of works.
Transformer and connected works at Chazhur WTP and Electrification works at Kolothumkadavu and Illikkal Pump Houses Supply, erection,testing and commissioning of 1No 250KVA/11KV/433V outdoor copper wound oil filled transformer with all accessories including four pole structure, transformer plinth of size 1.5x1.5x2.2m, spreading river sand & hard granite, fencing transformer yard, fixing gate, other miscellaneous works what so ever for the satisfactory completion of work and including the power allocation charges to be paid to KSEB etc. complete as per the direction of departmental officers and NIT vol II. Electrification works at two Pump houses with obtaining statutory approval from Electrical Inspectorate including preparation of drawings, obtaining approval for the drawings , arranging inspection of the installations and obtaining safety certificate etc. after completion of the work with power allocation charges to be paid to KSEB as CD and other charges etc. complete as per the direction of the departmental officers in charge and scope of work.
Road Restoration - Road restoration work after pipe line work from existing Intake well at Kolothumkadavu to WTP at Chazhur- 1013m including earthwork escavation work, Granular Sub Base - 0.50m, Wet Mix Macadam - 0.50m, Prime coat with bitumen imulsion, OGPC work, providing and laying seal coat sealing the voids in bituminous surface laid to the specified levels, grade and cross fall using as per the technical specification clause 510,case III:type C,Bitumen (S-65) etc complete as per the direction of Departmental officers in charge and scope of work. (The work includes earthwork escavation for road work in soil with hydraulic escator of 0.9 cum bucket capacity, cutting and loading to tippers, trimming bottom and side slope, construction of granular sub base by providing graded materials, mixing in a mechanical mix plat at OMC, carriage, spreading in uniform layers on prepared surface, compacting with vibratory power roller to achive the desired desity etc complete, providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechanical mix plant, carraige, laying, compacting of mixed materials etc complete, providing and applying primer coat with bitumen emmulsion (SS) on prepared surface of granular base including clearing of road surface and spraying primer etc complete, supplying and stacking 12mm hard blue granate broken stone in standard heaps, supplying and stacking 6mm hard blue granate broken stone in standard heaps, providing, laying and rolling of open graded premix carpet of 20 mm thickness with 0.27 cum of 12mm aggregate premixed with 12.96Kg of bitumen per 10sqm using penetration grade bitumen to required line, grade and level on a previously prepared base, after priming the existng surface with 5Kg of bitumen (VG 30) 10Sqm including mixing in a suitable plant, laying and rolling with a 3 wheel static roller of 80 - 100 KN capacity, finished to required level and grades, followed by a seal coat of 0.09 cum of 6mm aggregates premixed with 8.64Kg of bitumen per 10sqm as per the PWD specifications and direction of Departmental officers in charge and scope of work.)
Miscellanous works
Installation of Fire Hydrant in WTP - 1 no Installation of the fire hydrant by Supplying 100mm GI pipe 3m, 100mm CI D/F sluice valve with cap PN 1.6- 1No, 100mm CI hydrant valve with SS specials including all accessories with ISI mark-1no, pillar hydrant unit-1no, 100mm barrel nipple-1no, 100mm CID joint-1no, GI pipes-1m, DI/GI various specials with conveying, fixing, cutting, jointing, testing, commissioning according to the alignment, including excavating trenches in all kinds of soil, fencing, close timbering, bailing out water, brick work with common burnt clay machine moulded perforated bricks, providing and laying in position cement conrete of mix 1:3:6 for PCC, providing and laying R.C.C. of mix 1:2:4 for anchor blocks, centering, shuttering, strutting etc. and removal of form work for RCC works, steel reinforcement of grade Fe 500D or more for R.C.C work including straightening,cutting,bending,placing in position etc,12mm cement plaster finished with floating coat of cement of mix 1:4, complete,including dry stone masonry for protection chamber at the mouth of lead pipes including all cost of labour and materials, taking connection from existing 450mm DI CWGM line with newly laid 100mm GI pipe using all the materials such as MS saddle, adapter etc.without causing any damages to the existing utilities, labour charges for installation of fire hydrant syastem, welding charges, fixing charges of hydrant valve/pillar hydrant unit/barrel nipple etc.complete required for the completion of the work as per specification, direction of departmental officers in charge andscope of work. Providing Inauguration stone-2nos and sign boards and documentation required size, shape and specification etc. as per the direction of departmental officers in charge and scope of work
Chicago Constructions International Pvt Ltd
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid